• Title/Summary/Keyword: 전산화 단층촬영방법

Search Result 368, Processing Time 0.037 seconds

Comparative Study of 2 mm Video-thoracoscopic Examination and High-resolution Computed Tomography for Spontaneous Pneumothoarx Patients (자연기흉에서 고해상 전산화단층촬영술과 2 mm 비디오 흉강경검사의 비교 연구)

  • Lee, Song-Am;Chee, Hyun-Keun;Hwang, Jae-Joon;Cho, Seong-Joon;Lee, Sung-Ho;Kim, Kwang-Taik
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.362-368
    • /
    • 2007
  • Background: Spontaneous pneumothorax patients with blebs or bullae are considered to be good candidates for operation, and various objective diagnostic modalities have been performed for detection of blebs and bullae. This study was performed to compare the efficacy of thoracoscopic examination with using a minimally invasive 2 mm thoracoscope with high-resolution computed tomography (HRCT) for treating primary spontaneous pneumothorax. Material and Method: From June 2001 to March 2002, 34 patients with spontaneous pneumothorax undewent study with 2 mm video-thoracoscopic examination and HRCT. We regarded a blob larger than 5 mm in diameter as significant. Standard thoracoscopic wedge resection was performed in 18 patients with significant blob via a 2 mm video-thoracoscopic examination. 1 patient incurred bleeding, and the remaining 15 patients were treated with pleural drainage. Result: Multiple or single blob lesions were detected by 2 mm video-thoracoscope in 52.9% (18/34) of the patients with primary pneumothorax. For a total of 19 patients who were operated on, the diagnostic accuracy of the 2 mm video-thoracoscopic examination for bullae and blob was 94.7% (18/19), which was superior to that of HRCT (73.7%, 14/19). At a mean follow-up of $30{\pm}3$ months, no recurrence occurred in both the operative group and the non-operative group. Conclusion: 2 mm video-thoracoscopic examination under local anesthesia has higher diagnostic accuracy than HRCT, and it is a useful alternative for determining the operative indications for spontaneous pneumothorax.

The Role of Chest CT Scans in the Management of Empyema (농흉에서 전산화 단층촬영의 의의)

  • Heo, Jeong-Suk;Kwun, Oh-Yong;Sohn, Jeong-Ho;Choi, Won-Il;Hwang, Jae-Seok;Han, Seung-Beom;Jeon, Young-June;Kim, Jung-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.397-404
    • /
    • 1994
  • Background: To decide the optimal antibiotics and application of chest tube, examination of pleural fluid is fundamental in the management of empyema. Some criteria for drainage of pleural fluid have been recommended but some controversies have been suggested. Recently, newer radiologic methods including ultrasound and computed tomography scanning, have been applied to the diagnosis and management of pleural effusions. We undertook a retrospective analysis of 30 patients with pleural effusion who had CT scans of the chest in order to apply the criteria of Light et al retrospectively to patients with loculation and to correlate the radiologic appearance of pleural effusions with pleural fluid chemistry. Method: We analyzed the records of 30 out of 147 patients with pleural effusion undergoing chest CT scans. Results: 1) Six of the pleural fluid cultures yielded gram negative organisms and three anaerobic bacterias and one Staphylococcus aureus and one non-hemolytic Streptococci. No organism was cultured in ninteen cases(63.0%). 2) The reasons for taking chest CT scans were to rule out malignancy or parenchymal lung disease(46.7%), poor response to antibiotics(40.0%), hard to aspirate pleural fluid(10.0%) and to decide the site for chest tube insertion(3.3%). 3) There was no significant correlations between ATS stages and loculation but there was a tendency to loculate in stage III. 4) There was a significant inverse relationship between the level of pH and loculation(p<0.05) but there appeared to be no relationship between pleural fluid, LDH, glucose, protein, loculation and pleural thickening. 5) In 12 out of 30, therapeutic measures were changed according to the chest CT scan findings. Conclusion: We were unable to identify any correlations between the plerual fluid chemistry, ATS stages and loculations except pH, and we suggest that tube thoracotomy should be individualized according to the clinical judgement and serial observation. All patients with empyema do not need a chest CT scan but a CT scan can provide determination of loculation, guiding and assessing therapy which should decrease morbidity and hospital stay.

  • PDF

3-D Conformal Radiotherapy for CNS Using CT Simulation (입체조준장치를 이용한 중추신경계의 방사선 입체조형치료 계획)

  • 추성실;조광환;이창걸
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.90-98
    • /
    • 2003
  • Purpose : A new virtual simulation technique for craniospinal irradiation (CSI) that uses a CT-simulator was developed to improve the accuracy of field and shielding placement as well as patient positioning. Materials and Methods : A CT simulator (CT-SIM) and a 3-D conformal radiation treatment planning system (3D-CRT) were used to develop CSI. The head and neck were immobilized with a thermoplastic mask while the rest of the body was immobilized with a Vac-Loc. A volumetric image was then obtained with the CT simulator. In order to improve the reproducibility of the setup, datum lines and points were marked on the head and body. Virtual fluoroscopy was performed with the removal of visual obstacles, such as the treatment table or immobilization devices. After virtual simulation, the treatment isocenters of each field were marked on the body and on the immobilization devices at the conventional simulation room. Each treatment fields was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR) and digitally composited radiography (DCR) images from virtual simulation. Port verification films from the first treatment were also compared with the DRR/DCR images for geometric verification. Results : We successfully performed virtual simulations on 11 CSI patients by CT-SIM. It took less than 20 minutes to affix the immobilization devices and to obtain the volumetric images of the entire body. In the absence of the patient, virtual simulation of all fields took 20 min. The DRRs were in agreement with simulation films to within 5 mm. This not only reducee inconveniences to the patients, but also eliminated position-shift variables attendant during the long conventional simulation process. In addition, by obtaining CT volumetric image, critical organs, such as the eyes and the spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. Differences between the DRRs and the portal films were less than 3 m in the vertebral contour. Conclusion : Our analysis showed that CT simulation of craniospinal fields was accurate. In addition, CT simulation reduced the duration of the patient's immobility. During the planning process. This technique can improve accuracy in field placement and shielding by using three-dimensional CT-aided localization of critical and target structures. Overall, it has improved staff efficiency and resource utilization by standard protocol for craniospinal irradiation.

  • PDF

Treatment of Osteoid Osteoma with Radio-frequency - A case report - (유골 골종의 경피적 고주파 파괴술 - 1례 보고-)

  • Seo, Jai-Gon;Kim, Jee-Hyoung;Ahn, Choong-Mo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.1
    • /
    • pp.35-40
    • /
    • 2000
  • We report the radio-frequency ablation technique applied on an osteoid osteoma under CT guide and review other new methods of treatment for the osteoid osteoma. An 18-year-old boy with an osteoid osteoma at the left proximal tibia, which was visible at plain film and MRI. He was treated by the percutaneous radio-frequency ablation technique under CT guide after a needle biopsy. He is free from any symptom and able to do daily activities. So, we proposed that the percutaneous radio-frequency ablation technique under CT guide is the effective and safe treatment method for an osteoid osteoma.

  • PDF

LIPOMA OF THE PAROTID GLAND (이하선에 발생한 지방종)

  • Kim, Joon-Bae;Bae, Jung-Soo;Jang, Dong-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.4
    • /
    • pp.473-476
    • /
    • 1994
  • This is a case report on the lipoma of the parotid gland. Lipomas are common soft tissue neoplasms found only rarely in the region of the parotid gland, and therefore often not considered in the initial differential diagnosis of a mass presenting in this region. Clinically they can be confused with other being lesions and there was no reliable methods to make a preoperative diagnosis of the lipoma until 1980's; however, CT allows a specific diagnosis to be made in virtually all case. We experienced that CT imaging permit the preoperative diagnosis of the lipoma, so could remove it preserving the parotid gland.

  • PDF

A Method for Sinogram Interpolation for Reducing X-ray Dose (CT의 선량 감소를 위한 sinogram 보간 기법)

  • Kim, Jae-Min;Lee, Ki-Seung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.7C
    • /
    • pp.601-609
    • /
    • 2012
  • In this paper, a limited-view CT image reconstruction method was studied to reduce the scan times and the X-ray dose for the patients. To reduce streak artifacts which is caused by insufficient number of views, we introduce a sinogram interpolation method based on image matching. Image matching is achieved using the characteristics of the neighboring views including intensity, gradient and distance between the pixels. Interpolation is performed using the image matching results.. A numerical phantom and Al-acryl phantom were used for evaluating the effectiveness of the proposed interpolation method. The results showed that streak artifacts were reduced in the reconstructed images while the details of the images were preserved. Moreover, maximum 5% improvements in terms of PSNR were observed.

Technical Review of Target Volume Delineation on the Posterior Fossa Tumor : An Optimal Head and Neck Position (후두와 종양의 방사선치료 시 표적용적의 결정을 위한 적절한 치료자세 연구)

  • Yoon Sang Min;Lee Sang-wook;Ahn Seung Do;Kim Jong Hoon;YE Byong Yong;Ra Young Shin;Kim Tae Hyung;Choi Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.94-99
    • /
    • 2003
  • Purpose : To explore a 3D conformal radiotherapy technique for a posterior fossa boost, and the potential advantages of a prone position for such radiotherapy. Materials and Methods :A CT simulator and 3D conformal radiotherapy Planning system was used for the posterior fossa boost treatment on a 13-year-old medulloblastoma patient. He was placed In the prone position and Immobilized with an aquaplast mask and immobilization mold. CT scans were obtained of the brain from the top of the skull to the lower neck, with IV contrast enhancement. The target volume and normal structures were delineated on each slice, with treatment planning peformed using non-coplanar conformal beams. Results : The CT scans, and treatment In the prone position, were peformed successfully. In the prone position, the definition of the target volume was made easier due to the well enhanced tentorium, In audition, the posterior fossa was located anteriorly, and with the greater choice of beam arrangements, more accurate treatment planning was possible as the primary beams were not obstructed by the treatment table. Conclusion : .A posterior fossa boost, in the prone position, Is feasible in cooperating patients, but further evaluation is needed to define the optimal and most comfortable treatment positions.

CT Measurement of Diameter and Dimension of the Trachea in Normal Korean Adults (흥부 전산화단층촬영을 이용한 한국성인의 기관내경과 단면적의 측정)

  • Han, Jae-Youl;Kim, Kwang-Ho;Lee, Gun;Kim, Hyung-Jin;Cho, Soon-Koo;Sun, Kyung
    • Journal of Chest Surgery
    • /
    • v.34 no.7
    • /
    • pp.534-538
    • /
    • 2001
  • Background: Knowledge of size and morphology of the normal trachea is important for airway management and tracheal reconstruction. Conventional radiography is a simple method used to measure the tracheal diameter, but it is not accurate because of the artifacts related to image magnification and overlapping by the shoulder. The purpose of this study was to provide the normal values of the tracheal size and anatomy in Korean adults using Computerized Topography. Material and Method: There were 43 men and 34 women included in this study. They were divided into three age groups(group 1, 20-39 years ; group 2, 40-59 yeas , groups 3, $\geq$60 years). The anteroposterior and transverse diameters and cross - sectional areas of the trachea were measured at the level of the thoracic inlet(Level 1) and the aortic arch(Level 2). These values obtained at each level were compared between age groups and sexes. Result: In 43 men, the anteroposterior / transverse diameters(mean SD in millimeters) of the trachea at levels 1 and 2 were 19.95$\pm$2.99 / 17.72$\pm$2.13 and 19.77$\pm$2.57 / 18.02$\pm$2.19, respectively. In 34 women, those values at levels 1 and 2 were 15.56$\pm$2.12 / 14.18$\pm$2.07 and 15.35$\pm$1.82 / 15.00$\pm$1.60, respectively. At both levels, the anteroposterior and transverse diameters were significantly greater in men than in women (p<0.05). The cross-sectional area of the trachea at levels 1 and 2 were 279.14$\pm$61.37 / 281.93$\pm$63.97 $\textrm{mm}^2$ in men and 173.29$\pm$35.81 / 181.88$\pm$34.74 in women, respectively. They also showed significantly greater values in men than in women(P<0.05). There was no significant difference in diameters and cross-sectional areas of the trachea between age groups. Conclusion: There are significant differences in the internal diameter and cross- sectional area of the trachea between men and women in normal Korean adults, while the age difference was insignificant. We believed CT is a relatively accurate and safe way to measure the internal diameter and cross-sectional areas of the trachea.

  • PDF

The Effect of Lung Volume on the Size and Volume of Pulmonary Subsolid Nodules on CT: Intraindividual Comparison between Total Lung Capacity and Tidal Volume (전산화단층촬영에서 폐 반고형결절의 크기와 용적에 호흡이 미치는 영향: 개인 내 전폐용량과 일호흡량 간 비교)

  • Hyunji Lee;Chansik An;Seok Jong Ryu
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1534-1544
    • /
    • 2021
  • Purpose To examine the effect of lung volume on the size and volume of pulmonary subsolid nodules (SSNs) measured on CT. Materials and Methods A total of 42 SSNs from 31 patients were included. CT examination was first performed at total lung capacity (TLC), and a section containing the nodule was additionally scanned at tidal volume (TV). The diameter and volume of each SSN, as well as the cross-sectional lung area containing the nodule, were measured. The significance of the changes in measurements between TLC and TV within the same individuals was evaluated. Results The lung area and the diameter and volume of SSNs decreased significantly at TV by 12.7 cm2, 0.5 mm, and 46.4 mm3 on average, respectively (p < 0.001), compared to those at TLC. Changes in lung area between TV and TLC were positively correlated with the change in SSN diameter (p = 0.027) and volume (p = 0.014). However, after correction (by considering the change in lung area), the changes in SSN diameter (p = 0.124) and volume (p = 0.062) were not significantly different. Conclusion SSN size and volume can be significantly affected by lung volume during CT scans of the same individuals.

Geometric Assessment of Scapular Thickness by Computed Tomography (견갑골 두께의 전산화 단층 촬영을 이용한 기하학적 모델)

  • Yoo, Jeong Hyun;Chung, Soo Tai;Park, Sang Jun;Chang, Jun Hee;Paik, Doo Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.73-78
    • /
    • 2012
  • Purpose: Understanding exactly detailed anatomy and morphology of scapula is very important for further surgical procedures. This study was intended to provide accurate anatomic and morphologic information of scapula by exactly measuring scapular thickness using computed tomography and reconstructing its geometric model. Materials and Methods: Eight average lengths and two angles of 102 scapular structures obtained from 51 cadavers were generally measured by computed tomography. Also, to measure the scapular thickness, sagittal planes of each scapula were divided almost equally and the thicknesses of each sagittal plane was measured by computed tomography. After measuring every thickness, average results were calculated and the gender difference was compared by Student t-test. Results: Average results of the thickness of glenoid fossa, lateral border, medial border, and the middle 1/3 portion of the scapular body were 22.4 mm, 13.83 mm, 4.44 mm and 2.06 mm, respectively. Also, male scapulars were found to be significantly thicker than female. Based on these measured thicknesses, we reconstructed the 3-dimensional geometric model of scapula. Conclusion: From these results, glenoid fossa and lateral border were the thickest part of scapula, while the middle 1/3 portion of the scapular was the thinnest.