Application of Numerical Model for the Effective Design of Large Scale Fire Calorimeter (화재발열량계의 효율적 설계를 위한 수치해석 모델의 적용)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.28-33
    • /
    • 2010
  • The present study develops a numerical model based on the computational fluid dynamics technique to analyse the thermal flow characteristics of large scale fire calorimeter and examine the characteristics of primary parameters affecting on the uncertainty of heat release rate measurement. ANSYS CFX version 12.1 which is a commercial CFD package is used to solve the governing equations of the thermal flow field and the eddy dissipation combustion model and P-1 radiation model are applied to simulate the fire driven flow. The numerical results shows that the horizontal duct system with $90^{\circ}$ bend duct was shown relatively high deviated asymmetric flow profiles at the sampling location and the deviation of the velocity field was higher than that of the temperature and species quantities. The present study shows that the computational model can be applicable to optimize the design process and operating condition of the large scale fire calorimeter based on the understanding of the detail flow field.

Numerical Simulation of Flow and Thermal Performance in the Municapal Solid Waste Incinerator (도시폐기물 소각로내 열유동 해석을 위한 수치해석적 연구)

  • 박병수;이진욱;이정한;허일상
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1997.10a
    • /
    • pp.93-98
    • /
    • 1997
  • 도시폐기물의 효율적인 소각 처리를 위해서 폐기물 처리량 50 ton/day의 화격자 소각로를 대상으로 화학반응을 고려하여 연소실 내부의 열유동 현상을 전산모사하였다. 수치해석 프로그램으로 상용코드인 PHOENICS를 사용하여 3차원 모사를 하여 실험으로 파악할 수 없는 연소실 내부의 유동 및 폐기물과 산화제와의 반응을 계산하였다. 건조부, 주연소부, 후연소부에 1차연소용공기, 연료의 분포 및 폐기물의 발열량이 노내 열유동 현상에 미치는 영향을 조사하였다. 1차연소용 공기의 분포에 따라 노내 유동장의 형태에 변화가 있었으며, 벽면에서의 복사열전달을 고려한 경우 2차연소실과 출구근처에서 온도분포가 파일롯트 플랜트 실험결과와 잘 일치하는 r서으로 나타났다.

  • PDF

A Study on the Prediction of HLW Temperature from Natural Ventilation Quantity using CFD (전산유체학을 이용한 고준위 방사성 폐기물 처분장의 자연환기량에 의한 온도예측)

  • Roh, Jang-Hoon;Yu, Yeong-Seok;Jang, Seung-Hyun;Park, Seon-Oh;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.22 no.6
    • /
    • pp.429-437
    • /
    • 2012
  • This study predicted temperature in the disposal tunnels using computational fluid dynamics based on natural ventilation quantity that comes from high altitude and temperature differences that are the characteristics of high level waste repository. The result of the previous study that evaluated quantitatively natural ventilation quantity using a hydrostatic method and CFD shows that significant natural ventilation quantity is generated. From the result, this study performed the prediction of temperature in disposal tunnels by natural ventilation quantity by the caloric values of the wastes, at both deep geological repository and surface repository. The result of analysis shows that deep geological repository is effective for thermal control in the disposal tunnels due to heat transfer to rock and the generation of sufficient natural ventilation quantity, while surface repository was detrimental to thermal control, because surface repository was strongly affected by external temperature, and could not generate sufficient natural ventilation quantity. Moreover, this study found that in the case of deep geological repository with a depth of 200 m, the heatof about $10^{\circ}C$ was transferred to the depth of 500 m. Thus, it is considered that if the high level waste repository scheduled to be built in the country is designed placing an emphasis on thermal control, deep geological repository rather than surface repository is more appropriate.

Unsteady Combustion Phenomena in Scramjet Combustor (스크램제트 연소기의 비정상 연소현상)

  • Choi Jeong-Yeol
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.364-367
    • /
    • 2005
  • A series of computational simulations have been carried out for non-reacting and reacting flows in channel-type and divergent scramjet combustor configurations with and without a cavity. Transverse injection of hydrogen is considered with the injection pressure varying from 0.5 to 1.5 MPa. The detailed resolution of the oscillatory flow and flame dynamics are captured at sufficient scale to identify the underlying physical mechanisms, and the role of combustor configuration, cavity and amount of heat addition could be understood.

  • PDF

CFD Analysis for the Design of the Gas Tubine Combustor Using Medium-Btu Alternative Gas Fuel (중 발열량 대체연료 가스터빈 연소기의 설계를 위한 전산역학적 해석)

  • Seo, Je-Young;Lee, Chan
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.73-78
    • /
    • 2002
  • 대부분의 산업용 가스터빈은 고발열량의 액체 및 가스연료를 사용하도록 설계되었다. 그러나 이러한 고발열량 에너지원인 석유나 천연가스등은 자원의 고갈, 가격문제 및 환경문제 등으로 인해 점차적으로 사용량이 줄어들 전망이다. 그러므로, 최근 들어 석유 및 천연가스를 대체할 수 있는 대체연료에 대한 맡은 연구가 이루어지고 있으며, 그 중에서도 중발열량 또는 저발열량 연료인 석탄가스 및 중잔사유 가스의 활용성에 대한 연구가 활발히 진행되고있다.(중략)

  • PDF

Cooling CFD Analysis of a Car Batter Pack with Circular Cells (원통형 셀을 이용한 자동차용 배터리팩 냉각해석)

  • Shin, Hyun Jang;Lee, Joo Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.10
    • /
    • pp.693-698
    • /
    • 2017
  • The 18650 battery cell is known to be reliable and cost effective, but it has a design limitation and low electric capacity compared to pouch-type cells. Because its economy is superior, an 18650-cell-type battery pack is chosen. A reliable temperature is very important in automobile battery packs. Therefore, in this study, the temperature stability of the battery pack is predicted using CFD simulation. Following 3C discharge tests, the results for the heat generation of the battery cell are compared to the simulation results. Based on these results, a natural convection condition, forced convection condition, direct cell-cooling condition, cooling condition on the upper and lower surfaces of the battery pack, and cooling condition using air channels are all simulated. The results indicate that the efficiency and the performance of the air-channel-type cooling system is good.

Experimental and Numerical Study of Thermal Properties about various forms of Micro-heater (다양한 형상을 갖는 마이크로 히터의 열특성에 관한 실험 및 전산해석적 연구)

  • Kim, Jin-Woo;Kim, Jae-Choon;Lee, Jun-Yub;Chung, Jin-Taek
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1957-1962
    • /
    • 2008
  • As a field of MEMS, micro-heater fabricated by Au is being introduced and developed in recent years. Previous studies about thermal properties of various forms of micro-heater were not sufficient. In this work, numerical and experimental analysis of the heat generation and the temperature distribution of micro-heater packages for 8 different geometric cases were studied. We fabricated a micro-heater package with silicon wafer, on which Cr/Au layer was laminated before 8 geometric forms of micro-heater were patterned. In each cases, temperature distribution was measured with IR thermal camera. According to the experimental results, which show a good agreement with the results analyzed by CFD, it was found that at 0.5W, the temperature of micro-heater chip which contained $20000{\mu}m$-long, serpentine shaped micro-heater was elevated to a relatively high temperature of $78^{\circ}C$ Consequently, we proposed a geometry of micro-heater which has effective thermal characteristics.

  • PDF

A Numerical Study for Effective Operation of MSW Incinerator for Waste of High Heating Value by the Addition of Moisture Air (함습공기를 이용한 고발열량 도시폐기물 소각로의 효율적 운전을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Shin, Na-Ra;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.115-123
    • /
    • 2013
  • Stoker type incinerator is one of the most popular one used as municipal solid waste (MSW) incineration because, in general, it is quite suitable for large capacity and need no preprocessing facility. Nowadays, however, since the combustible portion of incoming MSW increases together with the decrease of the moisture content due to prohibition of directly burying food waste in landfill, the heating value of waste is remarkably increasing in comparison with the early stage of incinerator installation. Consequently, the increased heating value in incinerator operation causes a number of serious problems such as reduction of waste amount to be burned due to the boiler heat capacity together with the significant NO generation in high temperature environment. Therefore, in this study, a series of numerical simulation have been made as parameters of waste amount and the fraction of moisture in air stream in order to investigate optimal operating condition for the resolution of the problems associated with the high heating value of waste mentioned above. In specific, a detailed turbulent reaction flow field calculation with NO model was made for the full scale incinerator of D city. To this end, the injection method of moisturized air as oxidizer was intensively reviewed by the addition of moisture water amount from 10% and 20%. The calculation result, in general, showed that the reduction of maximum flame temperature appears consistently due to the combined effects of the increased specific heat of combustion air and vaporization heat by the addition of water moisture. As a consequence, the generation of NOx concentration was substantially reduced. Further, for the case of 20% moisture amount stream, the afterburner region is quite appropriate in temperature range for the operation of SNCR. This suggests the SNCR facility can be considered for reoperation. which is not in service at all due to the increased heating value of MSW.

Numerical Analysis of Urea Injection Conditions in the Selective Non-Catalytic Reduction(SNCR) Process (SNCR 공정에서 요소수 분무 조건에 관한 수치 해석)

  • Jung, Yu-Jin;Jeong, Moon-Heon;Park, Ki-Woo;Hong, Sung-Gil;Jung, Jong-Hyeon;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.356-359
    • /
    • 2012
  • SNCR 기술은 SCR에 비해 탈질 효율은 떨어지지만 촉매없이 고온 배출가스에 NH3 또는 요소수를 직접 분사하여 질소와 물로 환원시키는 방법이므로 초기 투자비 및 운영비가 적어 최근 국내 대다수의 소각장, 산업용 보일러 등에 널리 적용되고 있다. 단, SNCR 기술은 급격한 온도 강하나 접근의 불용이성, 불균일한 혼합, 액적의 증발시간 지연, 불균일한 운전 조건 등의 영향을 크게 받으며, 특히 반응 온도가 가장 중요한 변수로서 최적 반응 온도 영역대가 약 800~$1,000^{\circ}C$라는 점에서 이상적인 반응 온도 조건을 찾아서 환원제를 분무하는 것이 매우 중요하다. 이에 본 연구에서는 열유동 전산해석을 통해 스토커식 소각로의 폐기물 성상별 화염 온도 분포를 예측하고 적정 반응 온도 영역을 확인하여 요소수 주입 고도를 선정, 폐기물 성상별 분무 조건을 확립하고자 수치 해석적 연구를 수행하였다. 폐기물 성상(고질/중질/저질 폐기물)별로 화염 온도를 예측한 결과, 최적 반응 온도 영역대가 약 800~$1,000^{\circ}C$, 폐기물 성상의 심한 변화 때문에 소각로의 효율적인 연소 조건 제어에 어려움 등을 고려하여 약 700~$1,000^{\circ}C$ 온도 영역대를 환원제 분무 온도로 선정하였다. 폐기물별로 발열량에 따른 화염 온도가 모두 다르기 때문에 환원제 분무 위치를 3지점으로 선정하여 각 지점별로 분무 운전 조건을 확립하였다.

  • PDF

Study on The Thermochemical Degradation Features of Empty Fruit Bunch on The Function of Pyrolysis Temperature (반응온도에 따른 팜 부산물(empty fruit bunch)의 열화학적 분해 특성에 관한 연구)

  • Lee, Jae Hoon;Moon, Jae Gwan;Choi, In-Gyu;Choi, Joon Weon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.350-359
    • /
    • 2016
  • We performed fast pyrolysis of empty fruit bunch (EFB) in the range of temperature from $400{\sim}550^{\circ}C$ and 1.3 s of residence time. The effect of temperature on the yields and physicochemical properties of pyrolytic products were also studied. Elemental and component analysis of EFB showed that the large amount of potassium (ca. 8400 ppm) presents in the feedstock. Thermogravimetric analysis suggested that the potassium in the feedstock catalyzed degradation of cellulose. The yield of bio-oil increased with increasing temperature in the range of temperature from $400{\sim}500^{\circ}C$, while that of gas and biochar decreased and showed monotonous change each with increasing temperature. When the EFB was pyrolyzed at $550^{\circ}C$, the yield of bio-oil and char decreased while that of gas increased. Water content of the bio-oils obtained at different temperatures was 20~30% and their total acid number were less than 100 mg KOH/g oil. Viscosity of the bio-oils was 11 cSt (centistoke), and heating value varied from 15 to 17 MJ/kg. Using GC/MS analysis, 27 chemical compounds which were classified into two groups (cellulose-derived and lignin-derived) were identified. Remarkably the concentration of phenol was approximately 25% based on entire chemical compounds.