• Title/Summary/Keyword: 전산모사 알고리즘

Search Result 27, Processing Time 0.025 seconds

Modeling and Simulation of Heat Transfer inside the Packaging Box for Vaccine Shipping (백신 수송용 포장재 내부에서 열 전달의 모델링 및 시뮬레이션)

  • Duong, Dao Van;Choi, Ho-Suk;Lee, Sung-Chan;Bae, Yoon-Sung
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.604-609
    • /
    • 2008
  • This study is about the modeling and simulation of heat transfer in the box for packaging and shipping of vaccines. Comparison of the simulation results with experimental data revealed that a one-dimensional model (a spherical model of using a radius equivalent to the rectangular geometry of box) showed good agreement with experimental data during cooling process but did not successfully simulate heating process. It is considered that a rigorous boundary condition is not properly applied for outer surface of the box. However, we could successfully develop a basic algorithm for simulating heat transfer through multi-slabs combined with different materials including phase change material.

DESIGN OF COMPACT PARTICLE DETECTOR SYSTEM USING FPGA FOR SPACE PARTICLE ENVIRONMENT MEASUREMENT (FPGA를 이용한 우주 입자환경 관측용 초소형 입자검출기 시스템 설계)

  • Ryu, K.;Oh, D.S.;Kim, S.J.;Kim, H.J.;Lee, J.J.;Shin, G.H.;Ko, D.H.;Min, K.W.;Hwang, J.A.
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.2
    • /
    • pp.155-166
    • /
    • 2007
  • We have designed a high resolution proton and electron telescope for the detection of high energy particles, which constitute a major part of the space environment. The flux of the particles, in the satellite orbits, can vary abruptly according to the position and solar activities. In this study, a conceptual design of the detector, for adapting these variations with a high energy resolution, was made and the performance was estimated. In addition, a parallel processing algorithm was devised and embodied using FPGA for the high speed data processing, capable of detecting high flux without losing energy resolution, on board a satellite.

Numerical Investigation, Calibration Method of the Interaction between Ieodo Ocean Research Station and Ocean Current (수치해석을 이용한 이어도 기지 구조물이 해수 유동에 미치는 영향 분석과 해류 관측 평가 및 보정방안 연구)

  • Hong, Woo-Ram;Shim, Jae-Seol;Min, In-Ki;Kim, Chong-Am
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.5
    • /
    • pp.476-483
    • /
    • 2007
  • One of the main function of Ieodo Ocean Research Station is to service the information about the weather and fishing grounds condition which are collected through calibrating convection flow and ocean current around the station. However, due to the influence of the station's structure below sea level, it is difficult to obtain the exact flow data. Therefore, it is required to research on the effect of the structure and the method to evaluate and revise the observed data. In this paper, as a basic study, it deals with the algorithm that simulate the interaction between ocean current and the station structure, followed by discussions about the way to applicate the algorithm. Through 3-dimensional computational fluid dynamics analyses (using Navier-Stokes equations with K-turbulence model), the influence of the station and submerged rocks are quantitatively evaluated, and we would suggest methods how to obtain accurate flow information from the measured rough data.

Application of Fourier Optics to Defect Inspection of Display Substrates (푸리에 광학의 디스플레이 기판 결함 검출에의 활용)

  • Jung, Young Jin;Lee, Kwang
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • A method for inspecting defects in display substrates utilizing Fourier optics is proposed in this paper. A cost-effective inspection system can be realized with the proposed method, because it does not require a high-magnification microscope. Also, the proposed method can avoid tight tolerance for variations in displacement between substrate and camera, which is stems from shallow depth of field of the high-magnification microscope. In addition, possible damage caused by collisions between substrate and the inspection equipment can be avoided. The decision algorithm can be simpler than for a conventional inspection system, because spatial shift of periodic substrate patterns does not affect the intensity distribution of the diffracted light, by the Fourier transform property. The proposed method is explained with numerical studies, and experiments are carried out to check its feasibility for color-filter substrates of a liquid-crystal display.

Clinical Risk Evaluation Using Dose Verification Program of Brachytherapy for Cervical Cancer (자궁경부암 근접치료 시 선량 검증 프로그램을 통한 임상적 위험성 평가)

  • Dong‑Jin, Kang;Young‑Joo, Shin;Jin-Kyu, Kang;Jae‑Yong, Jung;Woo-jin, Lee;Tae-Seong, Baek;Boram, Lee
    • Journal of radiological science and technology
    • /
    • v.45 no.6
    • /
    • pp.553-560
    • /
    • 2022
  • The purpose of this study is to evaluate the clinical risk according to the applicator heterogeneity, mislocation, and tissue heterogeneity correction through a dose verification program during brachytherapy of cervical cancer. We performed image processing with MATLAB on images acquired with CT simulator. The source was modeled and stochiometric calibration and Monte-Carlo algorithm were applied based on dwell time and location to calculate the dose, and the secondary cancer risk was evaluated in the dose verification program. The result calculated by correcting for applicator and tissue heterogeneity showed a maximum dose of about 25% higher. In the bladder, the difference in excess absolute risk according to the heterogeneity correction was not significant. In the rectum, the difference in excess absolute risk was lower than that calculated by correcting applicator and tissue heterogeneity compared to the water-based calculation. In the femur, the water-based calculation result was the lowest, and the result calculated by correcting the applicator and tissue heterogeneity was 10% higher. A maximum of 14% dose difference occurred when the applicator mislocation was 20 mm in the Z-axis. In a future study, it is expected that a system that can independently verify the treatment plan can be developed by automating the interface between the treatment planning system and the dose verification program.

Evaluation of Clinical Risk according to Multi-Leaf Collimator Positioning Error in Spinal Radiosurgery (척추 방사선수술 시 다엽콜리메이터 위치 오차의 임상적 위험성 평가)

  • Dong‑Jin Kang;Geon Oh;Young‑Joo Shin;Jin-Kyu Kang;Jae-Yong Jung;Boram Lee
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.527-533
    • /
    • 2023
  • The purpose of this study is to evaluate the clinical risk of spinal radiosurgery by calculating the dose difference due to dose calculation algorithm and multi-leaf collimator positioning error. The images acquired by the CT simulator were recalculated by correcting the multi-leaf collimator position in the dose verification program created using MATLAB and applying stoichiometric calibration and Monte Carlo algorithm. With multi-leaf collimator positioning error, the clinical target volume (CTV) showed a dose difference of up to 13% in the dose delivered to the 95% volume, while the gross tumor volume (GTV) showed a dose difference of 9%. The average dose delivered to the total volume showed dose variation from -8.9% to 9% and -10.1% to 10.2% for GTV and CTV, respectively. The maximum dose delivered to the total volume of the spinal cord showed a dose difference from -14.2% to 19.6%, and the dose delivered to the 0.35 ㎤ volume showed a dose difference from -15.5% to 19.4%. In future research, automating the linkage between treatment planning systems and dose verification programs would be useful for spinal radiosurgery.

Study on Thermal Behavior and Design Method for Coil-type PHC Energy Pile (코일형 PHC 에너지파일의 열적 거동 및 설계법에 관한 연구)

  • Park, Sangwoo;Sohn, Jeong-Rak;Park, Yong-Boo;Ryu, Hyung-Kyou;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.8
    • /
    • pp.37-51
    • /
    • 2013
  • An energy pile encases heat exchange pipes to exchange thermal energy with the surrounding ground formation by circulating working fluid through the pipes. An energy pile has many advantages in terms of economic feasibility and constructability over conventional Ground Heat Exchangers (GHEXs). In this paper, a coil-type PHC energy pile was constructed in a test bed and its thermal performance was experimentally and numerically evaluated to make a preliminary design. An in-situ thermal response test (TRT) was performed on the coil-type PHC energy pile and its results were compared with the solid cylinder source model presented by Man et al. (2010). In addition, a CFD numerical analysis using FLUNET was carried out to back-analyze the thermal conductivity of the ground formation from the Ttype PHC energy RT result. To study effects of a coil pitch of the coil-type heat exchange pipe, a thermal interference between the heat exchange pipes in PHC energy piles was parametrically studied by performing the CFD numerical analysis, then the effect of the coil pitch on thermal performance and efficiency of heat exchange were evaluated. Finally, an equivalent heat exchange efficiency factor for the coil-type PHC energy pile in comparison with a common multiple U-type PHC energy pile was obtained to facilitate a preliminary design method for the coil-type PHC energy pile by adopting the PILESIM2 program.