The review provides updated concepts regard to the anatomy of the anterior cruciate ligament (ACL) footprints. The concept of anatomical ACL reconstruction, in which the graft is placed in the native ACL insertion area, has been introduced. However, there is still no consensus on the anatomical positioning of the femoral and tibial tunnel. In this study, authors review and update the literature regarding the tunnel position for anatomical ACL reconstruction.
Purpose: To evaluate the 2 to 4-year follow-up results after arthroscopic anterior cruciate ligament (ACL) reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position. Materials and Methods: Eighty-six ACL reconstructions could be evaluated. Evaluations included 2000 International Knee Documentation Committee (IKDC) subjective knee score, Lachman test, Pivot-shift test, KT-1000 arthrometer measurement, 2000 IKDC knee examination and second-look arthroscopy. Results: Seventy-five patients (87.2%) had over 80 in 2000 IKDC subjective knee score. Eighty-three patients (96.5%) had 1+firm end or negative Lachmann test. Seventy-eight patients (90.7%) had a negative Pivot-shift test. Eighty-three patients (96.5%) had less than 5 mm difference by KT-1000 arthrometer. Eighty patients (93.0%) were normal or nearly normal by 2000 IKDC knee examination. Second-look arthroscopy was done in fifteen cases. Nine cases showed good synovialization, four cases showed partial synovialization, two cases showed poor synovialization and graft failure was noted in one case. Conclusion: ACL reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position resulted in a good outcome in terms of rotatory stability as well as antero-posterior stability.
Catadioptric mirrors are widely used in automatic surveillance system. The major drawback of catadioptric mirror is its unequal image resolution. Equidistance catadioptric mirrir can be the solution to this problem. The exact axial alignment and the exact mount of mirror are the sources that can be avoided but the focal length variation is inevitable. In this paper, the effects of focal length variation on the computation of depth and height of object' point are explained and the effective and simple focal length finding algorithm is presented. First two object's points are selected, and the counterparts on the other stereo image are to be found using MSE criterion. Using four pixel distance from the image center, the assumed focal length is calculated. If the obtained focal length is different from the exact focal length, 24mm, the focal length value is modified by the proposed method. The method is very simple and gives the comparable results with the earlier sophisticated method.
Sohn, Hong Moon;Lee, Gwang Chul;Kim, Dong Hwi;Park, Sang Soo
Journal of the Korean Arthroscopy Society
/
v.16
no.2
/
pp.147-152
/
2012
Purpose: The purpose of this study was to compare the preoperative magnetic resonance image (MRI) findings with postoperative arthroscopic findings on meniscus injury with anterior cruciate ligament (ACL) rupture. Materials and Methods: We reviewed MRI images and arthroscopic findings of 225 patients treated by ACL reconstruction due to rupture, from February 2001 to November 2010. There were 154 cases of meniscus tear in arthroscopic findings. We examined the sensitivity for detecting meniscal tears varied with the presence of a rupture of the ACL, with the location of the tear within the meniscus, and among configurations of meniscal tears. Results: In the presence of a rupture of the ACL, the sensitivity of MRI was 0.88 for medial meniscal tears and 0.69 for lateral meniscal tears. And sensitivity of MRI was lowest in posterior horn and peripheral portion tears in lateral meniscus injury accompanying ACL rupture, sensitivity was low in anterior horn and flap shape tears in medial meniscus injury accompanying ACL rupture. Conclusion: In Meniscus injury with ACL rupture, a special attention shoulder given to the posterior horn and peripheral portion injury in lateral meniscus during arthroscopic surgery due to difficulty in detecting on MRI.
최근 전방십자인대 손상의 치료에 남아있는 인대 다발이 이식건의 생물학적 치유를 도우며 고유 수용감각(proprioception) 기능을 유지할 뿐만 아니라 슬관절의 전방 전위 억제의 생역학적 기능을 가지는 것으로 연구되고 있다. 이러한 이론을 바탕으로 남아있는 전방십자인대를 보존하는 노력들은 다양하게 시도되고 있다. 전방십자인대 손상의 자연 경과는 아직도 논란이 되고 있으나 선택적인 환자에 있어서 보존적 치료는 비교적 좋은 결과를 얻을 수 있으므로 불필요한 재건술을 줄일 수 있다. 최근 시도되고 있는 선택적 다발 재건술 및 남아있는 다발을 보존하는 전방십자인대 재건 수술 수기들은 다양한 방법으로 시도되고 있으며 남아있는 다발을 보존하는 장점이 있으나 협소한 적응증을 가진다. 저자들의 남아있는 다발을 보존하는 전방십자인대 재건술은 자가 슬괵건을 이용한 단일다발 재건술을 시행하면서 잔존하는 이완된 다발에 봉합사를 통과시킨 후 봉합사를 추가적인 터널 없이 bioabsorbable cross pin (RIGIDfix system, Mitek, Johnson & Johnson, USA) 구멍을 통하여 당기고 고정하는 방법이다. 전방십자인대 재건술시 남아있는 다발을 보존하는 방법은 이식건의 생물학적 치유을 촉진하고 또한 경골 부착부에 남아있는 기계수용체를 보존하므로 기능적 회복에 도움이 될 것으로 기대된다. 저자들의 방법은 비교적 광범위한 적응증을 가지며 적은 합병증으로 남아있는 다발을 효과적으로 보존할 수 있는 술식으로 전방십자인대 수술시 좋은 치료 선택의 하나로 사료된다.
The complication caused by a bioabsorbable interference screw is rare after anterior cruciate ligament reconstruction. We report a case of delayed inflammatory reaction at the tibial tunnel and femoral tunnel where the graft tendon had been fixed with a bioabsorbable interference screw ($Bioscrew^{(R)}$) for anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft.
The Journal of The Korea Institute of Intelligent Transport Systems
/
v.10
no.4
/
pp.36-43
/
2011
The forward collision of vehicles in high speed can cause a chain collisions and high fatality rate. Most of the forward collisions are caused by insufficient braking distance due to detection time of driver and safe distance. Also, accumulated detection time of driver is cause of chain collisions after the forward collision. The FVCWS prevents the forward collision by maintaining the safety distance inter-vehicle and reducing detection time of driver. However the FVCWS can cause chain collisions because the system that interacts only forward vehicle has accumulated detection time of driver. In this paper, we analyze forward and chain collisions of normal vehicles and FVCWS vehicles on static traveling scenario. And then, we analyze and compare V2V based FVCWS with them after explaining the system. The V2V FVCWS reduces detection time of driver alike FVCWS as well as remove accumulated detection time of driver by broadcasting emergence message to backward vehicles at the same time. Therefore, the system decrease possibility of forward and chain collisions. All backward normal vehicles and 3~4 backward FVCWS vehicles have possibility of forward and chain collisions in result of analysis. However V2V FVCWS vehicles almost do not chain collisions in the result.
Purpose: In anterior cruciate ligament (ACL) reconstruction, preservation of the remnant original tissue might promote graft healing and be helpful in proprioception. But this procedure is difficult and causes the notch impingement. So we introduce a surgical technique that makes a transtibial femoral tunnel at 10 or 2 o'clock position with preservation of remnant tissue. Surgical approach: We tried to preserve the remnant tissue and synovium as much as possible, especially those of tibial attachment and extending to the posterior cruciate ligament (PCL), so as to have some tension and to prevent notch impingement. We set the tibial drill guide at 40~45 degrees and the intra-articular guide tip was 1 mm anterior and medial to the conventional site. The starting point of tibial guide pin was proximal to the pes anserinus and anterior to the medial collateral ligament. When the reamer approached the cortical bone of the tibial articular surface, the reamer must be advanced very carefully to minimize injury to the remnant tissue. The tibial and femoral tunnel at 10 or 2 o'clock position were made with the reamer, the diameter of which was same with that of the graft. Conclusion: We report a remnant preserving technique in ACL reconstruction that makes a transtibial femoral tunnel at 10 or 2 o'clock position
Catadioptric mirrors are widely used in automatic surveillance system. The major drawback of catadioptric mirror is its unequal image resolution. Equidistance catadioptric mirror can be the solution to this problem. Even double panoramic structure can generate stereo images with single camera system. So two images obtained from double panoramic equidistance catadioptric mirror can be used in finding the depth and height values of object's points. But compared to the single catadioptric mirror. the image size of double panoramic system is relatively small. This leads to the severe accuracy problem in estimation. The exact axial alignment and the exact mount of mirror are the sources that can be avoided but the focal length variation is inevitable. In this paper, the effects of focal length variation on the computation of depth and height of object' point are explained and the effective focal length finding algorithm, using the assumption that the object's viewing angles are almost same in stereo images, is presented.
Kim, Kwang-Yeom;Kim, Sung-Kwon;Kim, Chang-Yong;Kim, Kwang-Sik
Tunnel and Underground Space
/
v.19
no.6
/
pp.479-489
/
2009
Appropriate investigation of ground condition near excavation face in tunnelling is an inevitable process for safe and economical construction. In this study mechanical parameters from drilling process for blasting were investigated for the purpose of predicting the ground condition, especially rock mass strength, ahead of tunnel face. Rock mass strength is one of the most important factors for classification of rock mass and making a decision of support type in underground construction. Several rock specimens which are considered homogeneous and having different strength values respectively were tested by hydraulic drill machines generally used. As a result, penetration rate is fairly related with rock mass strength among drilling parameters. It is also found that penetration rate increases along with the higher impact pressure even under same rock strength condition. It is finally suggested that new prediction method for rock mass strength using percussive pressure and penetration rate during drilling work can be utilized well in construction site.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.