• Title/Summary/Keyword: 전류효율

Search Result 1,844, Processing Time 0.036 seconds

Development of Public Washing Machine Monitoring System Using Electric Current (전류를 이용한 공용 세탁기 모니터링 시스템 개발)

  • Kong, Ji-Woo;Lee, Deok-Gyu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.11a
    • /
    • pp.339-342
    • /
    • 2020
  • 본 논문에서는 공용 세탁기의 작동 현황을 사용자에게 전달하여 불필요한 시간을 줄이는 시스템을 제안하고 있다. 제안하는 시스템은 아두이노와 전류 측정 센서를 연결하여 전류를 측정하고, 측정한 전류량을 이용하여 세탁기가 작동 중인지 판단하고, 사용자의 애플리케이션으로 사용 현황을 전달해준다. 사용자의 관점에서 효율성과 편리성을 중점에 두고 연구를 진행하였다.

Fabrication of deflector integrated laser diodes and light deflection (광 편향기 집적 레이저 다이오드의 제작 및 광의 편향)

  • 김강호;권오기;김종회;김현수;심은덕;오광룡;김석원
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.2
    • /
    • pp.171-176
    • /
    • 2004
  • A light deflector integrated laser diode(LD) was fabricated and the characteristics of LD and ourput beam deflection as a function of deflector injection current were measured. To integrate the deflector with LD, a passive waveguide was integrated with the LD and a triangular-type light deflector was fabricated on the upper clad of the passive waveguide section. Light deflection from the fabricated light deflector is controlled by the effective refractive index variation induced by carrier injection. To characterize the effect of the deflector injection current, threshold current, slope efficiency, and output beam spectrum were measured as a function of deflector injection current. From these measured data, the increment in the threshold current and the decrement of the slope efficiency were observed. However, the output beam spectrum was not affected by the deflector. The Beam Propagation Method(BPM) was used to simulate the proposed device and the light deflection was measured by the far-field pattern of the output beam as a function of the deflector injection current. In the fabricated deflector integrated LD, the deflection angle of 1.9$^{\circ}$ at the injection current of 15 ㎃ was obtained.

A Study on the Separation of Electrolyte from Amino Acid Solution through Electrodialysis (전기투석법을 이용한 아미노산으로부터 전해질 분리정제에 관한 연구)

  • 김석곤;한정우;김한성;전경용;조영일
    • Membrane Journal
    • /
    • v.4 no.3
    • /
    • pp.163-170
    • /
    • 1994
  • The separation of inorganic salt from amino acid solution using was performed electrodialysis. In order to review the availability of electrodialysis using isoelectric point of amino acid as a bio-separation technique, electrodialysis stacks were designed using ion exchange membrane. Separation of NaCl from amino acid solution was performed in the condition similar to amino acid fermentation process. To obtain otimum conditions of separation, leakage of amino acid depending of pH and limiting current density were measured. On the basis of optimum condition, removal of NaCl and leakage of amino acid were investigated quantitatively in batch and continuous process, and current efficiencies were also obtained. As a result of batch experiment for 11 hours each amino acid solution, removal efficiencies of NaCl were in the ranges of 96.1~96.2%. Amino acid leakage rate of glycine, methionine, alanine were 2.5, 1.7, 2.0% respectively. Current efficiencies were in the ranges of 44.5~44.6%. As a result of continuous experiment in various flow rate of each amino acid solution, it took 120 ~ 150 min to reach to steady state. Removal efficiency of NaCl was increased as the flow rate was decreased, but current efficiency was decreased. At the steady states, there were no leakage of amino acid.

  • PDF

Process Characteristics and Applications of High Density Plasma Assisted Sputtering System (HiPASS)

  • Yang, Won-Gyun;Kim, Gi-Taek;Lee, Seung-Hun;Kim, Do-Geun;Kim, Jong-Guk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.95-95
    • /
    • 2013
  • 박막 공정 기술은 반도체 및 디스플레이뿐만 아니라 대부분의 전자소자에 적용되는 매우 중요한 기술이다. 그 중, 마그네트론 스퍼터링 공정은 플라즈마를 이용하여 금속 및 세라믹 등의 벌크 물질을 박막으로 증착 가능한 가장 널리 사용되는 방법 중의 하나이다. 하지만, Fe, Co, Ni 같은 강자성체 재료는 공정이 불가능하며, 스퍼터링 타겟 효율이 40% 이하이고, 제한적인 방전압력 범위 및 전류 상승에 의한 높은 전압 인가 제한이 있다는 단점이 있다. 본 연구에서 사용된 고밀도 플라즈마 소스를 적용한 고효율 스퍼터링 시스템은 할로우 음극을 이용한 원거리에서 고밀도 플라즈마를 생성하여 전자석 코일을 통해 자석이 없는 음극으로 이온을 수송시켜 스퍼터링을 일으킨다. 따라서 강자성체 재료의 스퍼터링이 가능하며, 90% 이상의 타겟 사용 효율 구현 및 기존 마그네트론 스퍼터링 대비 고속 증착이 가능하다. 또한, $10^{-4}$ Torr 압력영역에서 방전 및 스퍼터링이 가능하다. 타겟 이온 전류를 타겟 인가 전압과 관계없이 0~4 A까지, 타겟 이온 전류와 상관없이 타겟 인가 전압을 70~1,000 V 이상까지 독립적으로 제어가능하다. 또한 TiN과 같은 질소 반응성 공정에서 반응성 가스인 질소를 40%까지 넣어도 타겟에 수송되는 이온의 양에 영향이 없다. 할로우 음극 방전 전류 40 A에서 발생된 플라즈마의 이온에너지 분포는 55 eV에서 가우시안 분포를 보였으며, 플라즈마 포텐셜인 sheath drop은 74 V 였다. OES를 통한 광학적 진단 결과, 전자석에 의한 이온빔 초점에 따라 플라즈마 이온화율을 1.8배까지 증가시킬 수 있으며, 할로우 음극 방전 전류가 60~100 A로 증가하면서 플라즈마 이온화율을 6배까지 증가 가능하다. 또한, 타겟 이온 전류와 관계없이 타겟 인가 전압을 300~800 V로 증가시킴에 따라 Ar 이온 밀도의 경우 1.4배 증가, Ti 이온 밀도의 경우 2.2배 증가시킬 수 있었으며, TiN의 경우 증착 속도도 16~44 nm/min으로 제어가 가능하다.

  • PDF

A Triple-Mode DC-DC Buck Converter with DPSS Function (DPSS 기능을 갖는 3중 모드 DC-DC Buck 변환기)

  • Yu, Seong-Mok;Hang, In-Ho;Park, Jong-Tae;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.411-414
    • /
    • 2011
  • This paper describes a tripple-mode DC-DC buck converter with DPSS Fucntion. The DC-DC buck converter operate in PWM(Pulse Width Modulation) mode at moderate to heavy loads(80mA~500mA), in PFM(Pulse Frequency Modulation)at light loads(1mA~80mA), and in LDO(Low Drop Out) mode at the sleep mode(<1mA). In PFM mode DPSS(Dynamic Partial Shutdown Strategy) is also employed to increase the efficiency at light loads. The triple-mode converter can thus achieve high efficiencies over wide load current range. The proposed DC-DC converter is designed in a CMOS 0.18um technology. It has a maximum power efficiency of 97.02% and maximum output current of 500mA. The input and output voltages are 3.3V and 2.5V, respectively. The chip size is $1465um{\times}895um$ including pads.

  • PDF

A Study on Wastewater Treatment by Electrochemical Treatment with Various Electrode Interval (전극 간격에 따른 전기화학적 처리를 통한 폐수처리에 관한 연구)

  • Song, Ju Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.417-423
    • /
    • 2019
  • A new wastewater treatment system was developed to remove nitrate nitrogen and phosphorus in synthetic wastewater through electrochemical treatment. Higher removal efficiencies of nitrate nitrogen were obtained as the current density increased. Higher nitrate removal efficiencies were obtained when the switching interval was 1 min. The total phosphorus removal rate according to the current density was found to be over 90% without being greatly affected by the change in current density and interval, and the total removal rate increased with increasing switching time (1 min interval). On the other hand, COD was not treated by electrochemical treatment, but rather increased as the electrode eluted. Also, the consumption rate of the electrode was smaller as the switching interval was shorter. Finally, removal efficiencies of 98.1% of nitrate and 90% of phosphorus were obtained through electrochemical treatment (current density $50mA/cm^2$, switching interval 1 min, flow rate 540 mL/min).

고속파 전자가열을 시도한 KSTAR 토카막 원형 플라즈마에서의 ICRF 고주파 부하 저항

  • Wang, Seon-Jeong;Kim, Seon-Ho;Gwak, Jong-Gu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.297-297
    • /
    • 2010
  • KSTAR 토카막의 두번째 실험 캠페인 동안 고속파 전자가열 (FWEH)을 위한 ICRF 고주파입사 실험을 실시하였다. 토로이달 자기장은 2 T, 플라즈마 전류는 200-300 kA, 주반경은 1.8 m, 부반경은 0.5 m의 원형 플라즈마가 가열 대상이 되었으며, 네개의 ICRF 안테나 전류띠 가운데 중심부의 두개의 전류띠를 최대 300 kW로 구동하기 위한 운전 주파수는 44.2 MHz가 선택 되었다. 이 주파수는 플라즈마의 모든 영역에서 이온 사이클로트론 공명을 일으키지 않으므로 플라즈마에 흡수되는 대부분의 출력은 전자에게 전달될 것으로 기대되었다. 낮은 고주파-플라즈마 결합으로 인하여 전송선의 최대 고주파 전압이 허용치를 초과하기 때문에 비교적 낮은 최대 출력만이 허용 되었으나, ECE에 의해 관측된 전자의 온도는 국지적으로 최대 150 % 까지 증가하는 것을 확인 할 수 있었다. 낮은 고주파-플라즈마 결합의 첫번째 원인은 FWEH의 효율이 이온을 가열할 때 보다 상대적으로 낮기 때문이다. 플라즈마 내에 이온 사이클로트론 공명층이 형성되면 높은 효율로 고주파를 입사 할 수 있다는 것은 잘 알려진 사실이다. 또다른 원인은 D 형상의 플라즈마에 맞도록 만들어진 안테나와, 원형 플라즈마간의 부조화로 인하여 고속파 차단층이 (Fast Wave Cutt-off Layer) 평균적으로 넓게 형성되기 때문이다. 플라즈마 외곽에 반드시 존재하는 낮은 플라즈마 밀도의 고속파 차단층 내부에서, 중심부로 향하는 고주파의 진폭은 지수함수로 감쇠하므로 가능하면 플라즈마 밀도를 높여 차단층 자체의 폭을 줄이거나, 안테나 전류띠를 플라즈마에 바짝 접근시켜야만 한다. 고주파 진단 장치로는 송출기의 출력과 반사파 측정 장치, 공명루프의 전압 측정 장치가 있는데, 이것들을 이용하여 안테나에 전달되는 출력 및 고주파-플라즈마 결합 효율을 나타내는 플라즈마에 대한 고주파 부하 저항을 구할 수 있다. 측정 결과, 부하 저항의 최소값은 진공시 또는 ICRF만의 방전시의 값 0.25 Ohm 보다 큰 0.5 Ohm을 나타냈으며, 최대값은 플라즈마의 상태에 따라 1 Ohm에서 2 Ohm 사이에서 매우 빠르게 요동하는 것을 확인했다. Mm 파 반사계의 측정에 의하면 플라즈마 언저리의 위치가 약 3 cm 정도의 크기로 요동하는 것으로 나타났는데, 부하 저항과 언저리 위치의 파형이 정확하게 일치하지 않지만 유사한 경향성을 가진 것으로 보인다. 따라서 플라즈마 언저리 위치의 제어를 통하여 가열 효율을 높게 유지할 수 있음을 알 수 있다. 본 발표에서는 실험의 소개와 함께 부하 저항의 관점에서 가열 효율을 높일 방안을 토론하도록 한다.

  • PDF

The Modeling of Overcurrent Relay with Reclosing using EMTP (EMTP를 이용한 재폐로부 과전류계전기 모델링)

  • Lim, Kyung-Sub;Seong, No-Kyu;Yeo, Sang-Min;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.209_210
    • /
    • 2009
  • 계전기는 1930년대에 처음 개발되어 지금까지 수많은 발전을 거치며 전력계통의 과도현상을 효과적으로 차단해왔다. 이러한 계전기의 종류에는 많은 종류가 있으며 본 논문에서는 배전선로 보호에 주로 쓰이는 재폐로부 과전류계전기에 대한 연구를 수행하였다. 배전계통에 사용하는 과전류계전기는 이상전류가 발생할 경우 순시특성과 한시 특성을 이용하여 계통을 차단하지만 고장검출시간은 비교적 짧은 편이다. 이런 현상은 짧은 시간 안에 발생하는 이상전류에 대해서도 계통을 정전상태로 만들기 때문에 효율적이지 못하다. 따라서 이러한 문제점을 해결하고자 재폐로부 과전류계전기가 개발되어 재폐로의 특징을 이용해 좀 더 긴 고장검출 시간을 확보하여 계통의 불필요한 정전을 방지하고 있다. 본 연구에서는 재폐로부 과전류계전기를 EMTP를 이용하여 모델링하고 계전기 동작을 검증하였으며 또한 EMTP를 이용하여 모델링된 배전계통에 적용시켜 모의결과를 분석하였다.

  • PDF

A Study on the Simulation method for the common-mode voltage and current in the voltage fed PWM inverter system (PWM 인버터로 구동된 유도전동기의 누설전류 억제에 관한 연구(I))

  • 전진휘;이재호;이상훈;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.246-253
    • /
    • 2000
  • 전동기의 제어기법과 제어기 등의 발달로 유도전동기는 산업용으로 널리 보급되고 있으며, 유도전동기를 고효율로 제어하기 위하여 PWM 인버터가 널리 사용되고 있다. 그리고 IGBT와 같은 고속 스위칭 소자의 발달로 인해 전압형 PWM 인버터의 스위칭 주파수가 증가가 가능하게 됐으며, 그로 인해 매우 우수한 동작 특성을 가지게 되었다. 그러나 고속 스위칭은 전압과 전류의 급격한 변화로 인해 매 스위칭마다 발생하는 고주파 성분의 커먼 모드전압과 전류를 발생하게 되고 이들은 베어링 전류와 축전압, 전도 및 방사 EMI, 기기의 절연수명 단축, 등의 악영향을 유발한다. 본 연구에서는 이러한 커먼 모드 전압과 전류에 대한 시스템 레벨 해석이 가능한 시뮬레이션 기법에 대해 실제 측정과 시뮬레이션을 통해 검정하였다. 이를 통해서 커먼 모드 전압과 전류가 PWM 인버터 시스템의 각 부에 미치는 영향을 쉽게 확인 할 수 있으며, 커먼 모드 전압과 전류의 저감을 위해 추가될 수 있는 부가적인 보조회로의 영향에 대해서도 제시된 시뮬레이션 기법을 통해 확인 할 수 있다.

  • PDF

Current Ripple Analysis of 3-phase Interleaved Bidirectional DC-DC Converter In Case of DC Link Voltage Variation (DC 링크 전압이 가변하는 경우의 3상 인터리브드 양방향 DC-DC컨버터의 전류리플 해석)

  • Sun, Daun;Jung, Jae-Hun;Nho, Eui-Cheol;Kim, Heung-Geun;Chun, Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.189-190
    • /
    • 2015
  • 본 논문은 계통연계형 인버터의 DC-Link단 전압 변동에 따른 3상 인터리브드 양방향 DC-DC 컨버터의 배터리 전류 리플 분석에 관한 것이다. 배터리 전류 리플 저감을 위하여 인터리브드 방식을 사용하였으나 전압 변동에 따라 전류 리플이 변하므로 전류 리플을 최소화 하는 방법을 찾고자 한다. 전 부하구간에서 전류 임계모드로 동작시켜 시스템의 효율을 높였으며, 배터리 전압과 DC-Link단 전압 변동에 따라 주파수와 듀티를 가변시켜 출력전력을 제어하였다. 시뮬레이션을 통하여 전류 리플 해석 결과를 보였다.

  • PDF