• Title/Summary/Keyword: 전류변조

Search Result 275, Processing Time 0.034 seconds

Simultaneous modulation of digital/SCM signal using a single LD for broadcasting in PON based optical access network (PON 기반 광가입자망에서 방송 신호 전송을 위한 단일 LD을 이용한 디지털/SCM 신호 동시 변조기술)

  • Kim Tae-Young;Kim Kyung-Hyun;Han Sang-Kook
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.5 s.347
    • /
    • pp.1-6
    • /
    • 2006
  • By comparing video-overlay method where digital and SCM signal are modulated in different optical source, we experimentally investigated the performance of simultaneous modulation of data and broadcasting signals using a single LD for broadcasting in PON based optical access network. The experimental results show that by increasing the minimum value of injected current for LD modulation above about 1.5 times of threshold current of LD, data and broadcasting signals can modulate without mutual interference. We also proposed and demonstrated the scheme of optical transmitter optimized for simultaneous modulation of data and broadcasting signals where anode and cathode of LD are separately used as signal interface for data and broadcasting signals, respectively.

Algorithm of Improving Sensorless Control Characteristics of PM Synchronous Motor in Over Modulation (과변조 영역에서의 영구자석동기전동기의 센서리스 제어특성 개선 알고리즘)

  • Lee, Han Sol;Choi, Hae Jun;Cho, Kwan Yuhl;Kim, Hag Wone
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.281-282
    • /
    • 2016
  • 영구자석 동기전동기의 회전자 위치검출센서를 사용하지 않는 센서리스 제어를 위해서는 모터에 인가되는 전압과 전류를 정확하게 알아야 한다. 일반적으로 영구자석동기전동기 모델기반의 회전자 위치검출 관측기에 사용되는 전압은 전류제어기의 출력인 전압지령 값을 사용한다. 그러나 전압지령 값은 인버터에 사용되는 데드타임의 영향으로 인해 실제 모터에 인가되는 전압과 차이를 갖는다. 특히 고속운전 시 과변조 구간에서의 전압지령 값은 실제 모터에 인가되는 전압과 큰 오차를 갖게 된다. 데드타임에 의한 전압 오차는 회전자 위치검출 오차에 미치는 영향이 비교적 작게 나타나지만, 과변조 구간에서의 전압 오차는 회전자 위치검출 오차를 매우 크게 만들어 센서리스 제어를 불가능하게 만들 수 있다. 본 논문에서는 추가적인 전압검출회로를 사용하여 모터에 인가되는 3상 전압을 검출하여 회전자 위치검출 관측기에 적용함으로써 과변조 구간까지 센서리스 제어 범위를 확장하는 방법을 시뮬레이션을 통하여 타당성을 검증하였다.

  • PDF

Measurement of Brillouin Gain Spectrum of Optical Fiber Using Direct Optical Frequency Modulation of Laser Diode (레이저 다이오드의 직접 광주파수 변조를 이용한 광섬유의 브릴루앙 이득 스펙트럼 측정)

  • Seo, Min-Sung;Yun, Seung-Chul;Park, Hee-Gap
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.143-148
    • /
    • 2006
  • A new method of measuring the Brillouin gain spectrum of optical fiber is proposed and demonstrated. Unlike existing methods, both the pump light and the counter-propagating probe light are generated from a single laser diode whose optical frequency is directly modulated by injection current modulation. The frequency difference between the pump and the probe is scanned continuously through optical frequency chirp occurring when the injection current is modulated with a square wave. The measured Brillouin gain spectrum of telecom single-mode fiber agrees well with that shown in other literature.

Investigation on Frequency Spectral Characteristics in Switching Frequency Modulation Control (스위칭주파수 변조제어의 주파수 스펙트럼 특성 고찰)

  • 박석하;김양모
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.221-228
    • /
    • 2000
  • 본 논문에서는 전기·전자 장비의 활용이 확대되면서 더욱 더 관심이 고조되고 있는 전자파장해에 대하여 논하고자 한다. 기존 PWM 직류전원장치에서는 회로 소자 및 배치에 따른 기생소자와 갑작스런 전압/전류의 변화에 의해 전자파장해를 발생시킨다. 본 논문에서는 PWM 직류전원장치에서 발생하는 전자파장해의 특성을 고찰하고, 출력전압 조절에 큰 영향을 주지 않는 범위내에서 PWM 제어가 가능하면서 두 개의 고정된 스위칭주파수로 연속적으로 변조하는 Bi-FM 변조제어방식과 랜덤하게 변화하는 스위칭주파수 변조제어방식을 이용하여 전도잡음을 저감시킬 수 있는 변조방식을 논할 것이다. 또한 이들 변조 방식의 주파수 스펙트럼 특성을 비교·분석하여 설명하고, 제어기를 분석·설계하여 실험을 통하여 스위칭주파수와 그 고조파 주파수들의 측대역으로 전도잡음이 분산되고 전도잡음의 피크치가 감소됨을 확인하고자 한다.

  • PDF

Fabrication of High Speed Modulation Doped SMQW-PBH-DFB-LD (변조 도핑된 SMQW-PBH-DFB-LD의 고속변조 특성)

  • 장동훈;이중기;조호성;박경형;김정수;박철순;김흥만;편광의
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.228-232
    • /
    • 1995
  • We have made modulation doped SMQW-PBH-DFB-LD for high speed optical communications. The waveguide and barrier layers were doped by Zn with the concentration of $1.2 \times 10^{18}cm^{-1}$. Mean threshold current and slope efficiency were 24.88 mA (minimum 16 mA) and 0.197 mW/mA (maximum 0.275 mW/mA) respectively. Linewidth enhancement factor ($\alpha$) of MD-SMQW-PBH-DFB-LD was reduced than that of SMQW-PBH-DFB-LD. Linewidth enhancement factor of 1.8 owes to the large gain coefficient of modulation doped active layer. The resonance frequency was linearly increased with the square root of optical power. The resonance frequency in small signal modulation was measured as 8 GHz and -3 dB modulation bandwidth was 10 GHzat $46mA(I_{th}+30mA)$..

  • PDF

반절연 InP를 이용한 초고속 DFB 레이저 다이오드의 제작 및 특성 연구

  • 주홍로;김형문;김정수;오대곤;박종대;김홍만;편광의
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1995.06a
    • /
    • pp.11-17
    • /
    • 1995
  • 반절연 InP를 전류 차단층으로 사용하는 초고속 변조 Distributed Feedback (DFB) 레이저의 다이오드를 제작 하였다. Grating이 형성된 InP 기판에 유기금속 증착법 (MOVPE)을 사용하여 다중 양자 우물 구조 성장 시켜 메사구조를 연성 한후, 전류 차단층으로 반절연 InP를 성장 하였다. 제작된 레이저 다이오드는 평균 문턱전류 10 mA, 기울기효율 14%이며, 30mA 구동 전류에서 10GHz 이상의 3dB 대역폭 특성을 보였다.

  • PDF

Single Sensor Current Control of a Three-Phase Voltage-Source PWM Converter Using Predictive State Observer (예측 상태 관측기를 이용한 3상 전압 원 PWM 컨버터의 단일 센서 전류 제어)

  • 이우철;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.249-256
    • /
    • 1999
  • 본 논문에서는 DC link단에 단일 전류 센서를 사용한 3상 전압 원 PWM 컨버터의 제어방법에 대해서 제안하고, DC link 전류로부터 3상 전류를 재 구축하는 PWM 변조 전략을 제시한다. 단일 전류 센서를 사용하여 3상 전류를 재 구축시 문제점은 2개의 유효 벡터중 1개 또는 2개의 유효벡터가 아주 짧은 시간 동안 인가 되었을 때로 이 경우에는 3상 전류를 적절히 재 구축할 수 없게 된다. 이런 경우에는 예측 전류 제어기를 사용하여 모든 동작 조건에서 믿을만한 3상 전류를 재 구축한다. 또한 디지털 제어로 인한 지연에 대한 보상도 제시된다. 본 논문에서는 3상 PWM 컨버터 제어시 예측 상태 관측기를 사용한 단일 센서 전류 제어가 논의되며 실험 결과로 입증된다.

  • PDF

Analysis of Effect of Capacitor Voltage Fluctuation Suppression Controller on Natural Arm Capacitor Voltage Balancing of a Direct Modulated MMC (직접 변조 방식 MMC의 전압 맥동 제어기가 암 캐패시터 전압 자연 밸런싱에 미치는 영향 분석)

  • Jung, Jae-Jung;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.385-386
    • /
    • 2016
  • 직접 변조 방식(direct modulation)을 사용한 Modular Multilevel Converter(MMC)의 6개의 암 캐패시터 전압의 자연균형화(Natural Balancing) 현상은 여러 연구 및 실험에서 관측되고 있다. 또한, 이러한 현상의 원리뿐만 아니라, 시스템 파라미터와 밸런싱 동특성사이의 관계가 수학적인 분석을 통하여 검증되었다. 직접 변조 방식은 간접 변조 방식(indirect modulation)과 달리, 입/출력 AC 및 DC 측 제어기 외에 암 캐패시터 전압 밸런싱을 위한 순환전류 제어기가 존재하지 않지만, 캐패시터 맥동 저감을 위해 일반적으로 캐패시터 2 고조파 맥동 제어기를 필요로 한다. 본 논문에서는 이러한 직접 변조방식을 사용한 MMC의 2고조파 전압 맥동 제어기가 암 캐패시터 전압 자연 밸런싱에 미치는 영향을 고찰하고 분석한다. 또한, 2 고조파 전압 맥동 제어기의 유무에 따른 전압 자연 밸런싱의 동특성에 대한 비교를 400MW MMC full-scale 시뮬레이션을 통해 살펴보도록 한다.

  • PDF

Power Spectrum of 2 Phase Random Centered Distribution Modulation Scheme with Multi Zero Vector (멀티 영벡터를 갖는 2상 랜덤 중앙 분포 변조기법의 파워 스펙트럼)

  • Oh S. Y.;Kim J. G.;Lim Y. C.;Yang H. Y.;Jung Y. G.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.21-30
    • /
    • 2003
  • 본 연구에서는 변조지수 M이 큰 영역에서는 고조파 스펙트럼의 광대역화 효과가 저하되는 2상 랜덤 중앙 정렬 변조기법 (Random Centered Distribution PWM : RCD)기법의 문제점을 해결하고자 멀티 영벡터 2상 RCD (Multi Zero Vector RCD : MZRCD) 변조기법을 제안하였다. 제안된 2상 MZRCD기법은 변조지수 M=0.7을 기준으로 하여 M이 0.7보다 큰 영역에서는 영벡터를 V(111)로 선택하고, 0.7보다 작은 영역에서는 V(000)을 선택한다. 제안된 방법을 유도모터 구동시스템에 적용해 본 결과, M이 0.7이상인 영역에서도 모터의 전압/전류 및 소음 스펙트럼의 광대역화 특성이 종전의 방법에 비하여 우수함을 확인할 수 있었다.

  • PDF