• Title/Summary/Keyword: 전력연구원

Search Result 973, Processing Time 0.026 seconds

Assessing greenhouse gas footprint and emission pathways in Daecheong Reservoir (대청댐 저수지의 온실가스 발자국 및 배출 경로 평가)

  • Min, Kyeong Seo;Chung, Se Woong;Kim, Sung Jin;Kim, Dong Kyun
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.10
    • /
    • pp.785-799
    • /
    • 2022
  • The aim of this study was to characterize the emission pathways and the footprint of greenhouse gases (GHG) in Daecheong Reservoir using the G-res Tool, and to evaluate the GHG emission intensity (EI) compared to other energy sources. In addition, the change in GHG emissions was assessed in response to the total phosphorus (TP) concentration. The GHG flux in post-impoundment was found to be 262 gCO2eq/m2/yr, of which CO2 and CH4 were 45.7% and 54.2%, respectively. Diffusion of CO2 contributed the most, followed by diffusion, degassing, and bubbling of CH4. The net GHG flux increased to 510 gCO2eq/m2/yr because the forest (as CO2 sink) was lost after dam construction. The EI of Daecheong Reservoir was 86.8 gCO2eq/kWh, which is 3.7 times higher than the global EI of hydroelectric power, due to its low power density. However, it was remarkable to highlight the value to be 9.5 times less than that of coal, a fossil fuel. We also found that a decrease in TP concentration in the reservoir leads to a decrease in GHG emissions. The results can be used to improve understanding of the GHG emission characteristics and to reduce uncertainty of the national GHG inventory of dam reservoirs.

A Study on Hay Preparation Technology for Italian Ryegrass Using Stationary Far-Infrared Dryer (정치식 원적외선 건조기를 이용한 이탈리안 라이그라스 건초 조제 기술 연구)

  • Jong Geun Kim;Young Sang Yu;Yan Fen Li;Li Li Wang;Hyun Rae Kim
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.42 no.4
    • /
    • pp.258-263
    • /
    • 2022
  • This experiment was conducted to confirm the possibility of manufacturing artificial Italian ryegrass hay using far-infrared rays in Korea. The machine used in this experiment was a far-infrared ray dryer capable of adjusting temperature, airflow, and far-infrared radiation, and was conducted on Italian ryegrass harvested in May. Conditions for drying were performed by selecting a total of nine conditions, and each condition was set to emission rate of 42 to 45%, and the internal temperature was set to 65℃. The speed of the air flow in the machine was 40-60 m/s, and the overall drying time was 30 minutes for 42% radiation, 25 minutes for 43% radiation, and 20 minutes for 45% radiation. The final dry matter content according to each drying condition was 88.5% on average, and the dry matter content suitable for hay was shown in the all treatment. Looking at the power consumption according to the drying conditions, the lowest was found in the treatment that dried for 20 minutes at 45% radiation. In the drying rate, there was no difference in drying conditions 1 to 5, but a significantly low tendency was shown in conditions 6 to 7. In terms of feed value, CP and IVDMD were higher than raw materials in most drying conditions, and ADF and NDF contents were low, and tended to be high in drying conditions 4, 7, and 8. Through the above results, it was judged that drying conditions 7 and 8 were the most advantageous when considering drying speed, power consumption, and quality.

Economic Evaluations of CO2 Capture Process from Power Plant Flue Gas Using Dry Sorbents (건식 흡수제를 이용한 발전소배가스의 CO2 회수공정 경제성분석)

  • Shin, Byung Chul;Kwak, Hyun;Lee, Kwang Min
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.646-653
    • /
    • 2012
  • We studied the economic evaluations on Korea Institute of Energy Research (KIER)'s $CO_2$ capture process using dry sorbents, and compared the results with those of comparable technologies. Capital and operating costs of the $CO_2$ capture system for 500 MW coal fired power plant were estimated to determine the economic feasibility. LCOE (Levelized Cost of Energy) and $CO_2$ capture cost appeared 32.46$/MWh and 28.15$/ton$CO_2$, respectively. The internal rate of return (IRR), the net present values (NPV), and the payback period (PBP), were calculated by assuming several variables. As the result of calculation, IRR of KIER's $CO_2$ capture system was 15%, NPV was calculated 6,631,000$, and PBP was 5.93 years at $50/t$CO_2$ of CER price. Consequently, this process can compete with other comparative processes using dry sorbents.

A Study on the Volcanic Ash Damage Sector Selection based on the Analysis of Overseas Cases and Domestic Spatial Information (해외 사례 분석과 국내 공간정보 분석을 통한 화산재 피해 분야 선정)

  • Han, Hyeon-gyeong;Baek, Won-kyung;Jung, Hyung-sup;Kim, Miri;Lee, Moungjin
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.5_1
    • /
    • pp.751-761
    • /
    • 2019
  • Mt. Baekdu, Mt. Aso, Mt. Sakurajima, Mt. Kikai and etc are distributed around the Korean Peninsula. Recently signs of eruption of Mt. Baekdu are increasing, raising concerns over possible damage to volcanic ash from seasonal winds during the winter eruption. Therefore, detailed procedures for investigation and countermeasures for volcanic ash spread and damage are required. But the standards for the warning and alarm signal of volcanic ash presented by Korea Ministry of Government Legislation are vague, with "when damage is expected" and "when serious damage is expected". In this study, to analyze the damage threshold and to apply the cases of overseas damage to the country, a survey was conducted on the establishment of domestic spatial information by public institutions with public confidence. As a result of the investigation of damage from volcanic ash overseas, the details of the damage cases were different depending on the type of life or income sources of each country. Therefore, instead of applying the volcanic ash damage cases abroad in Korea, spatial information analysis was performed to reflect domestic social and natural characteristics. In addition, we selected the areas to be considered in the event of volcanic ash damage in Korea. Finally, domestic volcanic ash damages should be classified as health, residential, road, railroad, aviation, power, water, agriculture, livestock, forest, and soil. When establishing the volcanic ash alarm optimized for Korea in the future, overseas volcanic ash damage cases and domestic spatial information construction in this study will be helpful in policy establishment.

Economical Analysis of the PV-linked Residential ESS using HOMER in Korea (HOMER를 이용한 PV 연계 가정용 ESS의 경제성 분석)

  • Eum, Ji-Young;Kim, Yong-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.36-42
    • /
    • 2019
  • Europe and North America are paying attention to residential ESS(Energy Storage System) that can manage energy efficiently. The ESS is a system that stores and manages the electric power by charging and discharging the battery. The ESS is generally used in conjunction with photovoltaic systems. The ESS supplies the load of the power generation time and stores the remaining PV power to supply the load at the non-power generation time. However, due to the high price of residential ESS, low electric rates and increasing block rates, there is no market of residential ESS in Korea. This paper reviews the price condition and the capacity for applying PV and residential ESS to household of apartments using HOMER in Korea.

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

Evaluation of Technical Production Efficiency and Business Structure of Domestic Combined Heat and Power (CHP) Operators: Panel Stochastic Frontier Model Analysis for 16 Collective Energy Operators (국내 열병합발전사업의 기술적 생산효율성 추정 및 사업구조 평가: 16개 집단에너지사업자에 대한 패널 확률프론티어모형(SFA) 분석)

  • Lim, Hyungwoo;Kim, Jaehyeok;Shin, Donghyun
    • Environmental and Resource Economics Review
    • /
    • v.30 no.4
    • /
    • pp.557-579
    • /
    • 2021
  • Collective energy is an intermediate stage in energy conversion and has a great influence on the power structure as a distributed power source. However, the problem of the collective energy business has recently emerged due to the worsening profitability of some collective energy operators. This study measured the technical efficiency of major operators through the estimation of the production efficiency of Korean collective energy operators, and based on this, we looked at ways to improve the profit structure of operators. After collecting detailed data from 16 collective energy operators between 2016 and 2019, the production efficiency of operators was estimated using the panel stochastic frontier model. As a result of the estimation, combined steam power operators showed the highest production efficiency and reverse CHP operators showed the lowest efficiency. Furthermore, as a result of examining the factors influencing profitability, it was confirmed that production efficiency has a positive effect on overall profitability. However, businesses with a high proportion of heat production, such as small district electricity operators, profitability was lower. This phenomenon is due to the structural limitations of the current heat sales market. Hence, the adjustment of the heat sales unit price is necessary to improve profitability of collective energy operators.

Regenerating Condition Optimization of NGCC Combined Carbon Capture Process Simultaneously Considering Absorption and Regeneration Rates (흡수율과 재생율을 동시 고려한 천연가스복합발전 공정 연계 이산화탄소 포집 공정의 재생 조건 최적화)

  • Jeong Hun Choi;Young-Hwan Chu
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.368-377
    • /
    • 2023
  • Natural Gas Combined Cycle(NGCC) recently receives lots of attention as an attractive form of power plants by virtue of its low carbon emission compared with coal-fired power plant. Nevertheless, it also needs carbon capture process since it is difficult to completely suppress carbon emission even for the NGCC. A simulation study has been performed to optimize operating condition of a carbon capture process using MEA considering low partial pressure of carbon dioxide in NGCC emission gas. For accurate optimization, overall process model including both NGCC and the carbon capture process has been built with a simulation software. Then, optimization in which various performance indices such as carbon dioxide absorption rate, solvent regeneration rate and power loss in the NGCC are simultaneously reflected has been done. Especially, it is noticeable that this study focuses on not only the amount of energy consumption but also the absorption and regeneration performance of carbon capture process. The best result considering all the performance indices has been achieved when the reboiler temperature is 120 ℃ and the reason has been analyzed.

Analysis of Internal Temperature Change according to the Application of Thermal Insulation Paint and Heat Pump in Broilers (육계사의 차열 페인트 및 히트펌프 적용에 따른 내부 기온 변화 분석)

  • Jun-Seop Mun;Rack-Woo Kim;Seung-Hun Lee;Sang Min Lee;Sang Kyu Choi
    • Journal of Bio-Environment Control
    • /
    • v.32 no.3
    • /
    • pp.197-204
    • /
    • 2023
  • Heat stress causes a decrease in immunity and disease occurrence in livestock, increasing mortality and impairing productivity. In particular, chickens are very vulnerable to high temperatures compared to other livestock species because their entire body is covered with feathers and sweat glands are not developed. Currently, air conditioning systems are essential in broiler houses to prevent high-air temperature damage to broilers, but conventional cooling facilities are greatly affected by the external environment, so there are limits to their use. In this study, to propose a cooling method, thermal insulation paint and a heat pump were apply in the broiler houses to evaluate the temperature reduction effect. The heat pump experiment was to analyze the cooling effect according to the change in ventilation rate and propose an appropriate. As a result of the experiment, the heat-insulating paint reduced the temperature of the broiler houses by maximum 1-2℃, and in the broiler houses where the heat pump was operated, the temperature decrease was the largest when the ventilation rate was the lowest. When the air temperature in the house is similar to or lower than the outside air temperature, it is considered to be most effective to use a heat pump while maintaining only the minimum ventilation rate.

Study on Sn-Ag-Fe Transient Liquid Phase Bonding for Application to Electric Vehicles Power Modules (전기자동차용 파워모듈 적용을 위한 Sn-Ag-Fe TLP (Transient Liquid Phase) 접합에 관한 연구)

  • Byungwoo Kim;Hyeri Go;Gyeongyeong Cheon;Yong-Ho Ko;Yoonchul Sohn
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.4
    • /
    • pp.61-68
    • /
    • 2023
  • In this study, Sn-3.5Ag-15.0Fe composite solder was manufactured and applied to TLP bonding to change the entire joint into a Sn-Fe IMC(intermetallic compound), thereby applying it as a high-temperature solder. The FeSn2 IMC formed during the bonding process has a high melting point of 513℃, so it can be stably applied to power modules for power semiconductors where the temperature rises up to 280℃ during use. As a result of applying ENIG surface treatment to both the chip and substrate, a multi-layer IMC structure of Ni3Sn4/FeSn2/Ni3Sn4 was formed at the joint. During the shear test, the fracture path showed that cracks developed at the Ni3Sn4/FeSn2 interface and then propagated into FeSn2. After 2hours of the TLP joining process, a shear strength of over 30 MPa was obtained, and in particular, there was no decrease in strength at all even in a shear test at 200℃. The results of this study can be expected to lead to materials and processes that can be applied to power modules for electric vehicles, which are being actively researched recently.