• Title/Summary/Keyword: 전력선 통신 모뎀

Search Result 49, Processing Time 0.024 seconds

Development of Low Power PLC Modem for Monitoring of Power Consumption and Breaking of Abnormal Power (전력감시 및 이상전력 차단 기능을 갖는 저전력 전력선통신 모뎀 개발)

  • Yoon, Jae-Shik;Wee, Jung-Chul;Park, Chung-Ha;Song, Yong-Jae;Kim, Jae-Heon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2281-2285
    • /
    • 2009
  • Powerline communication is the data signal which is modulated by carrier frequency through the installed powerline at in-home or office is transmitted and received signals are separated into data signal with using band-pass filter which cent-frequency is carrier frequency. The home gateway, an equipment which works as an gateway for ubiquitous home network, relays all functions of a home network. The home gateway must always be connected in order to provide seamless services. However it gives unfavorable power consumption. Therefore the needs for working in maximum power saving mode while there is no data traffic and for invoking to the normal function when it is necessary. So, in this paper we survey the development of low power PLC modem monitoring of power consumption and breaking abnormal power in the home Network.

A Study on Implementation of Powerline Carrier Modem using 5-ary Frequency Shift Keying Method (5-ary 주파수 천이 키잉 방식을 이용한 전력선 캐리어 모뎀 구현에 관한 연구)

  • Park, Sung-Wook;Park, Jong-Wook
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.39-44
    • /
    • 2005
  • In this paper, we use the 5-ary frequency shift keying method for robust powerline communication. To transmit the data by the 3-ary carrires among 5-ary carrirers and three carriers are 115kHz, 120kHz and 125kHz. Each time of three carrires is 0.33ms and total transmitting time duration from zero crossing point has 1ms. We use the dummy carriers which are 50kHz and 350kHz for monitoring the powerline channel state, dummy signal duration is received during 1ms. Experimentation result is shown that the implemented PLC transceiver has better than chirp transceiver at the capacitive load testing in spite of low transmission power.

Realization of the Transmitter of Communication Modem for Control Systems using Power-Distribution Circuit (전력선 버스를 이용한 제어 시스템의 통신모뎀 송신기 구현에 관한 연구)

  • Chung, Chang-Kyung;Park, Young-Chull;Sohn, Dong-Sup
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.3
    • /
    • pp.330-335
    • /
    • 1999
  • Recently, there a lot of activities on the researches that implement many kinds of control system using power lines. To implement that, it is desirable to use hybrid PSK model because it takes advantage of PSK and DPSK which has a low-bit-error rate. In this parer, we implement the transmitter of this model. Because the power line is not designed for the data communication, we separated the signal generator circuit and the signal loading circuit so that minimized noises from outside. Also, to make it easy on the experiments, most of process are performed by software. As a result, transmitting a high frequency signal on the power line made no effects on the electrical devices.

  • PDF

Realization of the Receiver of Communication Modem for Control Systems using Power-Distribution Circui (전력선 버스를 이용한 제어 시스템의 통신모뎀 수신기 구현에 관한 연구)

  • Chung, Chang-Kyung;Park, Young-Chull;Kang, Jeong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.3
    • /
    • pp.336-341
    • /
    • 1999
  • Up today, nationally published research results on the methods used in HA modems have studied and shown the major methods; the ASK method and the DS/SS method. In this paper, we applied the DPSK reception method on the PSK method so that solved the acquisition and tracking problem of the signal synchronization which is the defect of PSK. Also, it has been designed to fit in the CISRP and CENELEC specification so that make sure of no effects on other part of the system.

  • PDF

Design of Coupling and Rectifying Circuit for Monitoring of Transmitting Power of Maritime VHF Modem (해상 VHF 모뎀의 송신전력 모니터링을 위한 결합기 및 정류회로 설계)

  • Kim, Seung-Geun;Sung, So-Young;Lim, Young-Kon;Park, Dong-Kook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2642-2648
    • /
    • 2010
  • The design of coupling and rectifying circuits for the maritime VHF digital modem is investigated in this paper. To monitor the transmitting power of the modem, a directional coupler which is used to extract a small fraction of the transmitter signal power, and a rectifying circuit which make DC voltage proportional to the coupled rf power are designed and fabricated. The parallel-coupled line coupler with directivity of above 25 dB at 160 MHz bands is designed and it is shown that the output voltage of the rectifying circuit is linearly changing from 0.85 V to 1.6 V when the transmitting power of the modem is varying from 1 W to 25 W. The proposed coupler and rectifying circuits are expected to be suitable for maritime VHF digital modem.

Implementation of Lamp Monitoring System(LMS) for Ship Based on PLM (PLM 통신기반 선박용 LMS 구현)

  • Lim, Hyun-Jung;Yang, Hyun-Suk;Kim, Kun-Woo;Baek, Young-Jin;Kim, Yoon-Sik;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.182-189
    • /
    • 2007
  • This paper describes the implementation of control and monitoring system of ship's lamps at local area using power line communication method, power line modem(PLM). We design modem, microprocessor interface for electric power control by frequency control and analog to digital signal conversion, lamp device. PLM communication is very economical using existing electric power line unlike RS-232, RS-485 communications. We verify and confirm by experimental work that control and monitor lamp system for ship by an PLM communication.

Development of Dimming control system for 400W Metal Halide Lamp by Electronic Ballast and Power Line Modem (전력선모뎀 및 조광제어 안정기를 이용한 400W Metal Halide Lamp의 조광제어 시스템 개발)

  • Park, Chong-Yeon;Choi, Wang-Seop
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.193-198
    • /
    • 2009
  • In this paper, we developed remote dimming control system of electronic ballast for 400W metal halide lamp. This ballast could limit ignition current and soft start-up technique by the inverter with LCsCp resonance tank. The dimming circuit can dim from 400W to 200W by varying of the inverter switching frequency. The PLM consists of coupling circuit, BPF(Band-Pass Filter), FSK(Frequency Shift Keying) Modem and ${\mu}$-controller(Micro Controller). By coupling electronic ballast with PLM, the system that able to dimming the lamp through PLM is demonstrated by experimental results.

  • PDF

Implementation of 40kbps Narrowband Powerline Communication Modem using Chirp Spread Spectrum Method (Chirp 대역확산방식을 이용한 40kbps급 협대역 전력선 통신 모뎀 구현)

  • Lee Won-Tae;Woo Dae-Ho;Yu Young-Gyu;Lee Young-Chul
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.2
    • /
    • pp.116-123
    • /
    • 2005
  • Chirp spread spectrum method using both time and frequency component is fit to time varying channel such as powerline channel. The used chirp symbol based on the CEBus standard is the unit symbol which sweeps from 100kHz to 380kHz over a 25㎲. To evaluate the performance of between Chirp-SS and DSSS, we measured the bit error rate under Gaussian channel. Simulation result is shown that Chirp-SS has a about 3[dB] gain of SNR than DSSS. To verify the performance of implemented modem, it is made up the powerline channel environment. After adding several noises to it, we examined the receiving status of modem. The implemented modem is able to receive the signal over the powerline channel with having several noises and capacitive loads.

Design of A Current-mode Bandpass Filter in Receiver for High speed PLC Modem (고속 전력선통신 모뎀용 수신단측 전류모드 대역통과 필터 설계)

  • Bang, Jun-Ho;Lee, Woo-Choun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4745-4750
    • /
    • 2012
  • In this paper a $6^{th}$ 1MHz~30MHz bandpass filter for Power line communication(PLC) modem receiver is designed using current mode synthesis method which is good to design the low-voltage and low-power filter. The designed bandpass filter is composed of cascade connecting between $3^{rd}$ Butterworth highpass filter and $3^{rd}$ Chebychev lowpass filter. As a core circuit in the current-mode filter, a current-mode integrator is designed with new architecture which can improve gain and unity gain frequency of the integrator. The gain and the unity gain frequency of the designed integrator is each 32.2dB and 247MHz. And the cutoff frequency of the designed $6^{th}$ bandpass filter can be controlled to 50MHz from 200KHz according to controlling voltage and the power consumption is 2.85mW with supply voltage, 1.8V. The designed bandpass filter was verified using a $0.18{\mu}m$ CMOS parameter.