• Title/Summary/Keyword: 전력공급장치

Search Result 659, Processing Time 0.027 seconds

A Burn-in Test System with Dynamic Bone Allocation (동적 존 할당이 가능한 번인 시험 시스템)

  • Oh, Sam-Kweon;Shin, Joong-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.75-80
    • /
    • 2009
  • Bum-in test is one for eliminating semiconductor devices that are subject to early failures and other operational problems; it is usually carried out on the devices by imposing severe test conditions such as elevated voltages, temperatures, and time. In order for such a test to be performed, each burn-in board having devices to be tested, needs to be inserted into a corresponding slot. A set of such slots is called a zone. The slots comprising a zone can only have the burn-in boards with the devices of the same type. In order to test many different types of semiconductor devices, it is desirable to build a burn-in test system to have as many zones as possible. A zone controller controlling a zone, is a device that performs a burn-in test and collects test results. In case of existing systems, each zone controller takes care of a zone that consists of a fixed number of slots. Since a zone controller is, in most cases, embedded into a workstation that controls the overall testing process, adding new zone controllers is restricted by the spaces for them. As a way to solve or alleviate these problems, a dynamic zone system in which the number of slots in a zone can be dynamically allocated, is presented. This system maximizes the efficiency of system utilization, by altering the number of slots and hence minimizing the idle slots of a zone. In addition, all the test operations being performed must be aborted for maintenance in existing systems. In dynamic zone systems, however, a separate and independent maintenance is allowed for each slot, as long as the main power supply system has no problem.

Effects of Steam and Temperature on CO2 Capture Using A Dry Regenerable Sorbent in a Bubbling Fluidized Bed (기포 유동층 반응기에서 건식 재생 흡수제를 이용한 이산화탄소 회수에 미치는 스팀 및 온도의 영향)

  • Seo, Yongwon;Moon, Young Sub;Jo, Sung-Ho;Ryu, Chong Kul;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.537-541
    • /
    • 2005
  • A bubbling fluidized bed reactor was used to study $CO_2$ capture from flue gas using a sodium-based dry regenerable sorbent, sorbA which was manufactured by Korea Electric Power Research Institute. A dry sorbent, sorbA, consists of $Na_2CO_3$ for absorption and supporters for mechanical strength. $CO_2$ capture was effective in the lower temperature range of $50-70^{\circ}C$, while regeneration occurred in the range of $120-300^{\circ}C$. To increase initial $CO_2$ removal, some amount of steam was absorbed in the sorbents before injecting simulated flue gas. It was possible to remove most $CO_2$ for 1-2 minutes at $50^{\circ}C$ and residence time of 2 seconds with steam pretreatment. Little or no reduction in initial reaction rate and capture capacity was observed in multicycle tests. The carbonated and regenerated sorbent samples were analyzed by NMR to confirm the extent of reaction. The results obtained in this study can be used as basic data for the scale-up design and operation of the $CO_2$ capture process with two fluidized bed reactors.

A Study on Energy Efficiency Improvement of LDC Recycling Load Tester (LDC 재생형 부하 시험기의 효율 개선에 관한 연구)

  • Lee, Choon-il;Hong, Yeon-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.86-92
    • /
    • 2016
  • A high-capacity battery installed in a hybrid vehicle or electric vehicle is used to power, or as a power supply for, electric sub-assemblies. In order to use a high-capacity battery as a power supply for electric sub-assemblies, such as an electronic control unit or for lighting, radio, and navigation, there is a need for a DC converter that changes a high voltage of 240-400V to a low voltage of 12-14V, which is done with a low-voltage DC-DC converter (LDC). An LDC undergoes long-term aging so as to reduce latent defects in the production process. With regard to the usual aging method, an LDC is a DC-DC converter. So, a DC power supply is connected and used as input, and a programmable DC electronic load is the output. For stable operation, a product having a larger capacity by 10% (compared to an LDC) is used, and has a structure where electric power is dissipated into 100% heat. So, there is a problem with volume, based on the use of two pieces of equipment to test the LDC, and another problem based on the generation of heat in the programmable DC electronic load. Hence, this paper suggests a load test method as a way of recycling, where a significant portion of the electricity dissipated as heat in a load tester is returned as input. The method realizes savings of 80% or more in the electricity dissipated as heat through improvement in the efficiency of the recycling load tester.

Preparation of Electrocatalysts and Comparison of Electrode Interface Reaction for Hybrid Type Na-air Battery (Hybrid type Na-air battery를 위한 촉매들의 제조 및 전극 계면 반응 성능 비교)

  • Kim, Kyoungho
    • Journal of Adhesion and Interface
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • The importance of high capacity energy storage devices has recently emerged for stable power supply through renewable energy generation. From this point of view, the Na-air battery (NAB), which is a next-generation secondary battery, is receiving huge attention because it can realize a high capacity through abundant and inexpensive raw materials. In this study, activated carbon-based catalysts for hybrid type Na-air batteries were prepared and their characteristics were compared and analysed. In particular, from the viewpoint of resource recycling, activated carbon (Orange-C) was prepared using discarded orange peel, and performance was compared with Vulcan carbon, which is widely used. In addition, a Pt/C catalyst (homemade-Pt/C, HM-Pt/C) was synthesized using a modified polyol method to check whether the prepared activated carbon can be used as a supported catalyst, and a commercial Pt/C catalyst (Commercial Pt/C) and electrochemical performance were compared. The prepared Orange-C exhibited a typical H3 type BET isotherm, which is evidence that micropore and mesopore exist. In addition, in the case of HM-Pt/C, it was confirmed through TEM analysis that Pt particles were evenly distributed on the activated carbon supported catalyst. In particular, the HM-Pt/C-based NAB showed the smallest voltage gap (0.224V) and good voltage efficiency (92.34%) in the 1st galvanostatic charge-discharge test. In addition, the cycle performance test conducted for 20 cycles showed the most stable performance.

Development of a Finger Tactile Stimulator Based on E-Prime Software (E-Prime에 기반한 손가락 촉각 자극기의 개발)

  • Kim, Hyung-Sik;Min, Yoon-Ki;Kim, Bo-Seong;Min, Byung-Chan;Yang, Jae-Woong;Lee, Su-Jeong;Choi, Mi-Hyun;Yi, Jeong-Han;Tack, Gye-Rae;Lee, Bong-Soo;Jun, Jae-Hoon;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.703-710
    • /
    • 2010
  • In this study, a tactile stimulator was developed to resolve some problems from the previous version of the system such as system configuration, inappropriate stimulation control and additional problems. The developed tactile stimulator consists of control unit, drive unit and vibrator unit. The control unit was controlled by E-Prime software to generate appropriate vibration pulses. The drive unit supplies enough energy to the vibrator to generate effective stimulation pulses. The vibrator unit consists of small coin type vibrator and velcro, and was made to be attached at the hand easily. The developed tactile stimulator was designed by small-size, light-weight, low-power, simple-fabrication, max 35 channels and little delay time from instruction signal of E-Prime software to vibrator. The duration and magnitude of stimulation was controlled by 10 grades and the problems concerning stimulation control were compensated by wideband frequency ranges. Additionally, the electrical safety was ensured by low voltage operation. Vibrator was made to be attached on finger as well as on any part of the subject. Since this tactile stimulator is developed based on E-Prime software which is widely used in cognitive science, it is believed that this stimulator be suitable for the wide application of cognitive science study.

  • PDF

Study of CO2 Carbonation-Regeneration Characteristics of Potassium-Based Dry Sorbents According to Water Vapor Contents of Inlet Gas and Regeneration Temperature in the Cycle Experiments of Bubbling Fluidized-Bed Reactor (회분식 기포유동층 반응기에서 K-계열 건식흡수제의 주입수분농도 및 재생반응온도에 따른 CO2 흡수-재생 반응특성 연구)

  • Park, Keun-Woo;Park, Yeong Seong;Park, Young Cheol;Jo, Sung-Ho;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.349-354
    • /
    • 2009
  • In this study, a bubbling fluidized-bed reactor was used to study $CO_2$ capture from flue gas using a potassium-based dry sorbent. A dry sorbent, manufactured by the Korea Electric Power Research Institute, consists of 35% of $K_2CO_3$ for $CO_2$ absorption and 65% of supporters for mechanical strength. $H_2O$, a reactant of the carbonation reaction, was supplied in the reactor as a form of saturated water vapor at a given temperature. The experiment of the regeneration reaction was performed by raising up to a given temperature using $N_2$ as a fluidization gas. It was indicated that sorption capacity and regenerability of dry sorbents showed high-efficiency at $1.97\;mol\;H_2O/mol\;CO_2$ and $400^{\circ}C$, respectively. The regenerated sorbent samples were analyzed by TGA to confirm the extent of the reaction. When the regeneration temperature was $150^{\circ}C$, the regenerability of dry sorbents was about 60%, which was capable of applying those sorbents to a two-interconnected fluidized-bed reactor system with continuous solid circulation. The results obtained in this study can be used as basic data for designing and operating a large scale $CO_2$ capture process with two fluidized-bed reactors.

Performance Improvement of Dielectric Barrier Plasma Reactor for Advanced Oxidation Process (고급산화공정용 유전체 장벽 플라즈마 반응기의 성능 개선)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.459-466
    • /
    • 2012
  • In order to improved treatment performance of dielectric barrier discharge (DBD) plasma, plasm + UV process and gas-liquid mixing method has been investigated. This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical). The basic DBD plasma reactor of this study consisted of a plasma reactor (consist of quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode), air and power supply system. Improvement of plasma reactor was done by the combined basic plasma reactor with the UV process, adapt of gas-liquid mixer. The effect of UV power of plasma + UV process (0~10 W), gas-liquid mixing existence and type of mixer, air flow rate (1~6 L/min), range of diffuser pore size (16~$160{\mu}m$), water circulation rate (2.8~9.4 L/min) and UV power of improved plasma + UV process (0~10 W) were evaluated. The experimental results showed that RNO degradation of optimum plasma + UV process was 7.36% higher than that of the basic plasma reactor. It was observed that the RNO decomposition of gas-liquid mixing method was higher than that of the plasma + UV process. Performance for RNO degradation with gas-liquid mixing method lie in: gas-liquid mixing type > pump type > basic reactor. RNO degradation of improved reactor which is adapted gas-liquid mixer of diffuser type showed increase of 17.42% removal efficiency. The optimum air flow rate, range of diffuser pore size and water circulation rate for the RNO degradation at improved reactor system were 4 L/min, 40~$100{\mu}m$ and 6.9 L/min, respectively. Synergistic effect of gas-liquid mixing plasma + UV process was found to be insignificant.

Legal Review of Product Liability of a Defective Aircraft (군용항공기와 결합방지를 위한 개선방안 및 법적 책임관계 연구)

  • Cho, Young-Ki;Chung, Wook
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.20 no.2
    • /
    • pp.59-158
    • /
    • 2005
  • When a military aircraft suffers damages due to the defects in its design, manufacturing or notification, all of which are generally understood as products liability defects, the obvious compensation is sought as it would in other consumer good case. However, there exist clear yet unappreciated difference between general consumer goods and military aircraft, as far as products liability law is concerned - some sort of recovery should be obtained even when there exist only defects, not damages, to the aircraft because of the implication of defective parts is much grave than what can be expected in a consumer goods case. While certain anticipatory measures do exist in manual or at negotiation stages for the safety of military aircraft, such measures are ineffective, if not ambiguous, in recovery effort in the post-accident stage In another word, the standardized military procurement contract manuals and boilerplate forms do not appreciate the unique and dangerous military nature of military aircraft. There are many unique legal issues which can arise when trying to prevent defective aircraft or parts, or to recover compensations for accident due to such defects. At two-level, the government should establish legal system (or countermeasures if you'd like) for purchasing safer military aircraft. First, one should be able to work with legal ground and policy that allows selecting and purchasing safer goods - the purpose of such contract is not litigious, but rather in acquiring what are most reliable. Second, in case the defects do arise and lead to damages, solid legal principles and instructions should be established for effectively pursuing appropriate company, (usually a aerospace industry giant with much experience) for products liability - the purpose of such pursuit is inevitable for a public official, since he or she is no private business man with much flexibilities, even to the point of waiving such compensatory right for future business purposes. This article tries to identify problems in methods of procuring military aircraft or parts - after reviewing on how the military can improve on legal and policy grounds for procuring what will be the focus of future military strength, it will offer some of the ways to effectively handling and resolving a liability issues.

  • PDF

Study on Hydrogen Production and CO Oxidation Reaction using Plasma Reforming System with PEMFC (고분자 전해질 연료전지용 플라즈마 개질 시스템에서 수소 생산 및 CO 산화반응에 관한 연구)

  • Hong, Suck Joo;Lim, Mun Sup;Chun, Young Nam
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.656-662
    • /
    • 2007
  • Fuel reformer using plasma and shift reactor for CO oxidation were designed and manufactured as $H_2$ supply device to operate a polymer electrolyte membrane fuel cell (PEMFC). $H_2$ selectivity was increased by non-thermal plasma reformer using GlidArc discharge with Ni catalyst simultaneously. Shift reactor was consisted of steam generator, low temperature shifter, high temperature shifter and preferential oxidation reactor. Parametric screening studies of fuel reformer were conducted, in which there were the variations of the catalyst temperature, gas component ratio, total gas ratio and input power. and parametric screening studies of shift reactor were conducted, in which there were the variations of the air flow rate, stema flow rate and temperature. When the $O_2/C$ ratio was 0.64, total gas flow rate was 14.2 l/min, catalytic reactor temperature was $672^{\circ}C$ and input power 1.1 kJ/L, the production of $H_2$ was maximized 41.1%. And $CH_4$ conversion rate, $H_2$ yield and reformer energy density were 88.7%, 54% and 35.2% respectively. When the $O_2/C$ ratio was 0.3 in the PrOx reactor, steam flow ratio was 2.8 in the HTS, and temperature were 475, 314, 260, $235^{\circ}C$ in the HTS, LTS, PrOx, the conversion of CO was optimized conditions of shift reactor using simulated reformate gas. Preheat time of the reactor using plasma was 30 min, component of reformed gas from shift reactor were $H_2$ 38%, CO<10 ppm, $N_2$ 36%, $CO_2$ 21% and $CH_4$ 4%.