• Title/Summary/Keyword: 전력감시

Search Result 638, Processing Time 0.031 seconds

A Study on the Development of the Single Station Fixed Temperature Detector of Low Power Consumption for Residential Fire Prevention (주택화재 예방을 위한 저소비 전력형 단독경보형 정온식감지기 개발에 관한 연구)

  • Park, Se-Hwa;Cho, Jae-Cheol
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.61-68
    • /
    • 2010
  • In this paper, a research and development result for the implementation of single station fixed temperature detector for residential fire prevention is described. The detector was developed for the certification in Japanese market because of very low domestic market situation. It is in the situation that there is no other regulation especially for residential detectors in Korea, Japanese case has been reviewed. Investigation of domestic legal circumstances and a comparative study for the test standard owned by KFI (Korea Institute of Fire Industry & Technology) and JFEII (Japan Fire Equipment Inspection Institute) respectively are also indicated. The detector alarms with a buzzer and an indicating LED. In the implementation ultra low power MCU(Micro Controller Unit) is applied to control the sleeping state and the monitoring state properly with low current consumption. To sense the temperature fast response thermistor is adopted in the design of fixed temperature residential detector. Automatic test function and alarm stop function are also considered in the design. The major factors which influence to current consumption are explained for the purpose of design reference. Main electronics circuit parts related to it's characteristics of the detector are described. It is explained that the measured current and experimental result of the battery discharge can be met over 10 years operation.

Effect Analysis of Classical Line TI-21 type Audio Frequency Track Circuit from KTX Sancheon Return Current Harmonics (KTX산천 귀선전류고조파가 일반선 TI-21형 AF궤도회로에 미치는 영향분석)

  • Choi, Jae Sik;Kim, Hie Sik;Park, Ju Hun;Kim, Bun Gon
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.1
    • /
    • pp.38-45
    • /
    • 2016
  • The power transformation system of High Speed rolling stocks like KTX-Sancheon has shown excellent control capacities in the areas of riding comfortability, switching efficiency, safety and energy consumption due to technical developments in power-electronics, high speed & large scale integrated semiconductors and microprocessors. However, harmonics from IGBT, a high speed switching device used in the Convertor & Invertor equipment of rolling stocks have given rise to various problems in transformer substations, signaling systems, data transmission systems and facility monitoring systems. Especially, TI21 non-insulated track circuits have malfunctioned due to the influence of returning current harmonics which were generated at around of integer times of the number of power transformation equipment in the frequency domain. This paper, measures and analyzes various schemes to analyze the traveling path of the returning current harmonics generated due to the relationship between the rolling stocks and track circuits on site. Ultimately, theseschemes will be used to design high speed rolling stocks, AF track circuits and a common grounding network.

A Study on Energy Savings of a DC-based Variable Speed Power Generation System (직류기반 가변속 발전 시스템을 이용한 에너지 절감에 관한 연구)

  • Kido Park;Gilltae Roh;Kyunghwa Kim;Changjae Moon;Jongsu Kim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.666-671
    • /
    • 2023
  • As international environmental regulations on ship emissions are gradually strengthened, interest in electric propulsion and hybrid propulsion ships is increasing, and various solutions are being developed and applied to these ships, especially stabilization of the power system and system efficiency. The direct current distribution system is being applied as a way to increase the power. In addition, verification and testing of safety and performance of marine DC distribution systems is required. As a result of establishing a DC distribution test bed, verifying the performance of the DC distribution (variable speed power generation) system, and analyzing fuel consumption, this study applied a variable speed power generation system that is applied to DC power distribution for ships, and converted the power output from the generator into a rectifier. A system was developed to convert direct current power to connect to the system and monitor and control these devices. Through tests using this DC distribution system, the maximum voltage was 751.5V and the minimum voltage was 731.4V, and the voltage fluctuation rate was 2.7%, confirming that the voltage is stably supplied within 3%, and a variable speed power generation system was installed according to load fluctuations. When applied, it was confirmed through testing that fuel consumption could be reduced by more than 20% depending on the section compared to the existing constant speed power generation system.

Data Acquisition System Applying TMO for GIS Preventive Diagnostic System (GIS 예방진단시스템을 위한 TMO 응용 데이터 수집 시스템)

  • Kim, Tae-Wan;Kim, Yun-Gwan;Jang, Cheon-Hyeon
    • The KIPS Transactions:PartA
    • /
    • v.16A no.6
    • /
    • pp.481-488
    • /
    • 2009
  • GIS is used to isolate large power electrical equipment using SF6 gas. While GIS has simple structure, it has few break down, relatively high reliability. But it is hard to check up faults for reason of pressure. Faults of GIS should have a ripple effect on community and be hard to recovery. Consequently, GIS imports a preventive diagnostic system to find internal faults in advance. It is most important that reliability on the GIS preventive diagnostic system, because it estimates abnormality of system by analysis result of collected data. But, exist system which used central data management is low efficiency, and hard to guarantee timeliness and accuracy of data. To guarantee timeliness and accuracy, the GIS preventive diagnostic system needs accordingly to use a real-time middleware. So, in this paper, to improve reliability of the GIS preventive diagnostic system, we use a middleware based on TMO for guaranteeing timeliness of real-time distributed computing. And we propose an improved GIS preventive diagnostic system applying data acquisition, monitoring and control methods based on the TMO model. The presented system uses the Communication Control Unit(CCU) for distributed data handling which is supported by TMO. CCU can improve performance of the GIS preventive diagnostic system by guaranteeing timeliness of data handling process and increasing reliability of data through the TMO middleware. And, it has designed to take full charge of overload on a data acquisition task had been processed in an exist server. So, it could reduce overload of the server and apply distribution environment from now. Therefore, the proposed system can improve performance and reliability of the GIS preventive diagnostic system and contribute to stable operation of GIS.

Implementation and Economic Evaluation of Movable Power Supply Device for Electric Vehicle (EV용 이동형 전원공급장치의 구현 및 경제성 평가에 관한 연구)

  • Choi, Sung-Moon;Han, Byeong-Gill;Lee, Hu-Dong;Kim, Mi-Young;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.77-86
    • /
    • 2020
  • Power quality problems caused by feeder voltage drop and extension construction cost problems can occur with the increasing utilization rates of the existing fixed-type EV (electric vehicle) charger. Moreover, EV users might not be able to access the EV charger due to a lack of EV charging facilities. Therefore, this paper proposes an MPSD (movable power supply device) for EVs to overcome user inconvenience caused by the insufficient number of chargers and extension cost issues. The proposed MPSD was mainly composed of a PV (photovoltaic) system, ESS (energy storage system), EV charging system, and monitoring and control system. Furthermore, there are three operation modes available to enhance the flexibility of the MPSD application, depending on the situation. This paper also presents an economical evaluation modeling using the present worth method to consider the cost and benefit elements. The simulation results based on proposed modeling showed that MPSD is more economical than the existing EV charger. Moreover, its profit can be increased significantly depending on the distance to the installation point.

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Song, Yoon-Ho;Kim, Yoo-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.15-24
    • /
    • 2007
  • Two kinds of temperature monitoring technology have been introduced in this study, which can measure coincidently temperatures at many points along a single length of cable. One is to use a thermal sensor cable comprizing of addressable thermal sensors. The other is to use an optic fiber sensor with Distributed Temperature Sensing (DTS) system. The differences between two technologies can be summarized as follows: A thermal sensor cable has a concept of "point sensing" that can measure temperature only at a predefined position. The accuracy and resolution of temperature measurement are up to the capability of the individual thermal sensor. On the other hand, an optic fiber sensor has a concept of "distributed sensing" because temperature is measured practically at all points along the fiber optic cable by analysing the intensity of Raman back-scattering when a laser pulse travels along the fiber. Thus, the temperature resolution depends on the measuring distance, measuring time and spatial resolution. The purpose of this study is to investigate the applicability of two different temperature monitoring techniques in technical and economical sense. To this end, diverse experiments with two techniques were performed and two techniques are applied under the same condition. Considering the results, the thermal sensor cable will be well applicable to the assessment of groundwater flow, geothermal distribution and grouting efficiency within about loom distance, and the optic fiber sensor will be suitable for long distance such as pipe line inspection, tunnel fire detection and power line monitoring etc.

Analysis and implications of North Korea's new strategic drones 'Satbyol-4', 'Satbyol-9' (북한의 신형 전략 무인기 '샛별-4형', '샛별-9형' 분석과 시사점)

  • Kang-Il Seo;Jong-Hoon Kim;Man-Hee Won;Dong-Min Lee;Jae-Hyung Bae;Sang-Hyuk Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.167-172
    • /
    • 2024
  • In major wars of the 21st century, drones are expanding beyond surveillance and reconnaissance to include land and air as well as sea and underwater for purposes such as precision strikes, suicide attacks, and cognitive warfare. These drones will perform multi-domain operations, and to this end, they will continue to develop by improving the level of autonomy and strengthening scalability based on the High-Low Mix concept. Recently, drones have been used as a major means in major wars around the world, and there seems to be a good chance that they will evolve into game changers in the future. North Korea has also been making significant efforts to operate reconnaissance and attack drones for a long time. North Korea has recently continued to engage in provocations using drones, and its capabilities are gradually becoming more sophisticated. In addition, with the recent emergence of new strategic Drones, wartime and peacetime threats such as North Korea's use of these to secure surveillance, reconnaissance and early warning capabilities against South Korea and new types of provocations are expected to be strengthened. Through this study, we hope to provide implications by analyzing the capabilities of North Korea's strategic Drones, predicting their operation patterns, and conducting active follow-up research on the establishment of a comprehensive strategy, such as our military's drone deployment and counter-drone system solutions.

A Development of Monitoring and Control System for Improved the Voltage Stability in the Power System (전력계통의 전압안정도향상을 위한 감시제어시스템 개발)

  • Lee, Hyun-Chul;Jeoung, Ki-Suk;Park, Ji-Ho;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.437-443
    • /
    • 2013
  • This paper was developed a monitoring and control system to use reactive power control algorithm. This algorithm could be improved voltage stability in power system. This method was controlled the voltage for stability improvement, effective usage of reactive power, and the increase of the power quality. PMS(Power Management System) has been calculate voltage sensitivity, and control reactive power compensation device. The voltage control was used to the FACTS, MSC/MSR(Mechanically Switched Capacitors/Reactors), and tap of transformer in power system. The reactive power devices in power system were control by voltage sensitivity ranking of each bus. Also, to secure momentary reactive power, it had been controlled as the rest of reactive power in the each bus. In here, reactive power has been MSC/MSR. The simulation result, First control was voltage control as fast response control of FACTS. Second control was voltage control through the necessary reactive power calculation as slow response control of MSR/MSR. Third control was secured momentary reactive reserve power. This control was method by cooperative control between FACTS and MSR/MSC. Therefore, the proposed algorithm was had been secured the suitable reactive reserve power in power system.

유도 결합 플라즈마 스퍼터 승화법을 이용한 Cr 박막 증착 및 특성 분석

  • Choe, Ji-Seong;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.243-243
    • /
    • 2012
  • 화석연료를 대체할 새로운 청정 에너지원의 요구가 높아지고 있는 현 시점에서 고효율, 무공해, 무소음 등의 장점으로 인해 친환경적 에너지원으로 연료전지의 수요가 증가하고 있다. 연료전지 분리판으로 고밀도 흑연을 종래에 가공하여 제작하였는데, 가공이 어렵고, 비용이 크게 들며, 대량생산이 어렵다는 등의 문제로 스테인리스강을 위주로 한 금속 분리판 개발이 이루어지고 있다. 본 연구에서는, 낮은 가격, 고속 증착, 우수한 가공성, 높은 기계적 강도 및 전기전도도, 화학적 안정성 및 내식성을 충족시키기 위하여 스테인리스 강박(0.1 mm이하)에 보호막으로 CrN을 선택하였다. 저가격화를 위하여 새로운 증착원인 스퍼터-승화형 소스의 가능성을 유도 결합 플라즈마에 Cr 봉을 직류 바이어스 함으로써 시도하였다. 10 mTorr의 Ar 유도 결합 플라즈마를 2.4 MHz, 400 W로 유지하면서 직류 바이어스 전력을 120 W (615 V, 0.19 A) 인가하였을 때 10분 동안의 증발양이 0.35 gr으로 측정이 되어 그 가능성을 확인할 수 있었다. 또한 OES(Optical emission spectrometer)를 이용하여 RPS로 방전시킨 고밀도 ICP를 측정한 결과 842.4 nm, 811.4 nm, 772.3 nm 등의 파장에서 높은 intensity를 갖는 peak을 찾을 수 있었고, 이 peak 들은 Ar 중성의 peak임을 확인할 수 있었다. ICP+DC bias로 Cr rod를 가열하는 공정에서의 plasma를 OES로 측정한 결과 Ar 중성의 peak은 감소하고, 520.5 nm, 425.5 nm, 357.7 nm 등의 파장에서 높은 intensity를 갖는 peak을 찾을 수 있었으며, 이 peak들은 Cr 중성의 peak임을 확인할 수 있었다. OES 측정 data를 토대로 공정 중의 rod type Cr target의 교체 주기를 예측할 수 있고 공정 중 실시간 감시가 가능할 것으로 기대된다.

  • PDF

SDN based Discrimination Mechanism for Control Command of Industrial Control System (SDN 기반 산업제어시스템 제어명령 판별 메커니즘)

  • Cho, Minjeong;Seok, Byoungjin;Kim, Yeog;Lee, Changhoon
    • Journal of Digital Contents Society
    • /
    • v.19 no.6
    • /
    • pp.1185-1195
    • /
    • 2018
  • Industrial Control System (ICS) is a system that carry out monitoring and controls of industrial control process and is applied in infrastructure such as water, power, and gas. Recently, cyber attacks such as Brutal Kangaroo, Emotional Simian, and Stuxnet 3.0 have been continuously increasing in ICS, and these security risks cause damage of human life and massive financial losses. Attacks on the control layer among the attack methods for ICS can malfunction devices of the field device layer by manipulating control commands. Therefore, in this paper, we propose a mechanism that apply the SDN between the control layer and the field device layer in the industrial control system and to determine whether the control command is legitimate or not and we show simulation results on a simply composed control system.