• Title/Summary/Keyword: 전달 관로

Search Result 570, Processing Time 0.034 seconds

Remote Field Energy Flow Path at Nonmagnetic Coaxial Tubes (비자성체 이중관의 원격장 에너지 전달 경로)

  • Yi, Jae-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.526-531
    • /
    • 2001
  • The flow of remote field eddy current energy is studied at nonmagnetic coaxial tubes by using both experiments and finite element calculations based on commercial software package. The results showed that remote field eddy current energy at coaxial tubes flow along over the outer surface of external tube, not through the gap between internal and external tubes. This means that the through wall transmission characteristic of remote field eddy current testing (RFECT) is still valid at tube in tube configurations and the RFECT could be potential nondestructive technique for crack detection, spacer location and gap sizing at the coaxial CANDU fuel channel tubes.

  • PDF

Single Frequency Analysis of Flexural Vibration of Thin Plate by Using the Ray Tracing Method (레이추적기법을 이용한 평판 횡진동의 단일주파수 해석)

  • Chae Ki-Sang;Ih Jeong-Guon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.267-270
    • /
    • 2000
  • 강제가진을 받는 진동장은 직접장과 반사장으로 이루어진다. 직접장은 무한구조요소가 점입력을 받을 때의 해와 같으며, 반사장은 직접장에 의해 발생되는 1차 반사파 및 추가로 발생하는 무수한 반사파들의 합으로 나타낼 수 있다. 본 논문에서는 점가진을 받는 유한한 평판의 단일 주파수 해석을 수행하기 위한 레이추적기법을 연구하였다. 이를 위해, 직접장은 고주파수 가정을 이용하여 원형전달파로 근사화하고. 이 원헝전달파를 다수의 파동관 (wave tube)으로 이산화하였다. 균일한 경계조건과 무시할 만큼의 미약한 굴절효과를 가정하고 경계에서의 정반사 (specular reflection)만을 고려하여, 경계에서의 입사파동관. 전달 및 반사파동관의 기하학적 관계를 제안하였다. 이들 파동관이 평판 내부를 진행하면서 관측점에 미치는 영향들을 합성하여 비교적 정확한 강제진동응답을 얻을 수 있음을 단일 평판의 예제를 통하여 확인할 수 있었다 그러나, 연성된 평판의 경우에는 다소 부정확한 결과를 얻었다.

  • PDF

Heat Transfer and Friction Characteristics of Louver Fin and Tube Heat Exchangers under Wet Conditions (루버핀-관 열교환기의 습조건에서의 열전달 및 마찰특성에 대한 실험 연구)

  • Kwon, Young Chul;Chang, Keun Sun
    • Applied Chemistry for Engineering
    • /
    • v.19 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • An experimental study was conducted to investigate the effect of a tube row, a fin pitch and an inlet humidity on air-side heat and mass transfer performance of louvered fin-tube heat exchangers under wet conditions. Experimental conditions were varied by three fin pitches, two rows, two inlet relative humidities. Experimental results showed that the heat transfer performance decreased and the friction increased with the decrease of fin pitch, for 2 row heat exchanger. The effect of fin pitch on heat transfer performance was negligible with 3 row heat exchanger. The changes in relative humidity was not affected heat transfer and friction. However, the mass transfer performance was slightly decreased with the increase of relative humidity and with the decrease of fin pitch. The mass transfer performance of the louvered fin-tube heat exchanger decreased with the decrease of the fin pitch and was different according to the number of tube row.

Assessment of the MELCOR 1.8.6 condensation heat transfer model under the presence of noncondensable gases (중대사고 해석코드 MELCOR 1.8.6의 비응축성기체 존재 시 응축열전달 모델 평가)

  • Yoo, Ji Min;Lee, Dong Hun;Yun, Byong Jo;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.1-20
    • /
    • 2016
  • A condensation heat transfer model is very important for the safety analysis of nuclear power plants. Especially, condensation under the presence of noncondensable gases (NCGs) is an important issue in nuclear safety because the presence of even a small quantity of NCGs in the vapor largely reduces the condensation rate. In this study, the condensation heat transfer model of the severe accident analysis code MELCOR 1.8.6 has been assessed using a set of condensation experiments performed under the thermal-hydraulic conditions similar to those inside a containment during design-basis accidents or severe accidents. Experiment conditions are categorized into 4 types according to the shape of the condensation surface: vertical flat plates, outer surface of vertical pipes, inner surface of vertical pipes, the inner surface of horizontal pipes. The results of the calculations show that the MELCOR code generally under-predicts the condensation heat transfer except the condensation on inner surface of vertical pipes.

Experimental Study on the Strength of Underground Conduit (통신용 지하매설관의 강도 특성에 관한 연구)

  • Baik Song-Hoon;fang Wang-Kyu;Chung Sung-Tak
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.230-233
    • /
    • 2004
  • 현재 KT의 관로포설 공법은 관 상부 토피 1m를 확보한 상태에서 차량하중이 작용한다는 가정하에서 제정된 것이며, 토피 1m를 확보하지 못하는 구간에는 별도의 보강공법을 적용하고 있다. 그러나 현재 관로공사의 대부분을 차지하는 도로유관공사는 도로 조성이 종료되는 시점에는 토피 1m를 확보하지만, 도로조성 공사기간 중에는 별도의 보강공사 없이 토피 60cm 내외에서 공사 차량의 하중이 관로에 그대로 전달되고 있어 관로의 찌그러짐 현상이 발생하고 있다. 본 논문은 이와 같은 조건에서도 고품질의 관로를 확보하기 위하여 현행 FC관로 뿐만 아니라 지하매설관으로 사용되는 각종 재질의 관에 대한 특성을 검토하였으며 매설관 변형실험을 통하여 도로유관공사에 적합한 관로재질을 제시하였다.

  • PDF

An Experimental Study on Heat Transfer in the Furan Foundry Sand Fluidized Bed (Furan Foundry Sand 유동층에서 열 전달 특성에 관한 연구)

  • Park, Jong-Suen;Baek, Ko-Kil;Kim, Uen-Young;Jeon, Sung-Taek;Lee, Duck- Bong
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.105-117
    • /
    • 1995
  • Heat transfer coefficients on a single spiral coil tube in the furan foundry sand fluidized bed have been investigated. Heat transfer coefficients(ho) to an immersed single spiral coil tube were measured in the bed. The bed diameter was 0.21 m. The following quantities were varied: (l)bed temperature, (2)mean particle diameter, (3) fluidization rate, (4)the ratio of heated coil tube pitch to diameter(p/Do), and (5)the ratio of heated coil tube pitch to mean particle diameter(p/dp). In addition, the experimental values of maximum Nusselts number were compared with the values of maximum Nusselts number predicted by the existing correlations. The values of heat transfer coefficient increase with the increase in bed temperature and fluidization rate, but decrease with increase in particle diameter. An empirical formulus of maximum Nusselts number which is applicable in the furan foundry sand fluidization bed is as follows: $$Nu_{max}=1.01\;Re^{0.48}Prg^{0.4}(p/dp)^{0.28}(p/Do)^{0.05}$$.

  • PDF

생쥐 정소에서 C-terminal Src kinase (Csk) 발현과 Src kinase 활성의 조절

  • 계명찬;최진국;안현수;김영수
    • Proceedings of the Korean Society of Developmental Biology Conference
    • /
    • 2003.10a
    • /
    • pp.66-66
    • /
    • 2003
  • Protein tyrosine kinases는 표적단백질의 tyrosine 잔기를 인산화하는 효소로서 다양한 종류의 성장인자, peptide 호르몬, cytokine 수용체 하위의 세포 내 신호전달에 관여한다. Non-receptor tyrosine kinase의 일종인 c-Src는 세포막에서 발생한 ligand-receptor 상호작용 하위의 신호전달에서 중요한 역할을 하며 C-terminal Src kinase (Csk)는 Src kinase의 C-terminal tyrosine 잔기를 인산화시켜 Src kinase의 활성을 저해한다. 이러한 Src-Csk loop를 통한 세포 내 신호전달과정은 세포의 증식과 분화, 사멸 조절에 중요한 기능을 갖지만 정소의 발생과 분화 과정에서 Src-Csk loop의 발현 및 정자형성 과정에서의 기능은 밝혀지지 않았다. 본 연구에서는 생쥐 정소에서 출생 후 성적 성숙과정에서 Csk의 발현과 Src kinase 활성의 변동을 조사하였다. Csk mRNA 발현은 생 후 2주령 이하의 미성숙 정소에서 다량으로 발현되었고 사춘기 정소 이후에는 오히려 감소하였다. Csk 단백질의 발현 양상은 mRNA 발현양상과 일치하였다. c-Src kinase 활성은 생 후 2주에 급격히 증가하고 이 후 4주령에서 감소하다가 성체 (8주령)에서 다시 증가하여 가장 높았다. 성체 조직의 Csk 단백질 현존량이 미성숙 개체보다 적은 반면 Src kinase 활성은 가장 높아 Csk 발현의 감소는 Src kinase 활성을 증가하는 것으로 사료된다. 면역조직화학방법으로 정소 조직 내 Csk의 발현양상을 조사한 결과 Leydig cell, Sertoli cell, germ cell 등 도처에서 발현되었으며 Sertoli cell 에서의 발현은 세정관 상피의 구성에 따른 차이가 확인되었다. 성체의 세정관 내에서는 감수분열 이후의 정세포(spermatid)를 감싸고 있는 Sertoli cell의 강소측에서 강한 Csk 활성이 검출되어 생식세포의 분화과정 동안 세정관 상피의 조직재구성에 관여하는 것으로 사료된다. Leydig cell에서의 발현은 생후 1주령까지는 미미하였으나 이후 2주령 이후에는 다량으로 발현함이 확인되어 adult type Leydig cell에서 진행되는 steroidogenesis와의 관련성을 추측할 수 있다. 미성숙 정소로부터 분리한 Sertoli cell-enriched culture에 200 nM testosterone을 처리하였을 때 Csk mRNA의 발현의 증가를 확인할 수 있었으므로 androgen에 의한 Sertoli cell의 분화과정에 Csk가 관여하고 있음을 알 수 있다. 결론적으로 성적 성숙에 따른 생쥐 정소 내 Src-Csk loop의 발현과 Src kinase 활성의 변동은 정소 내 간충조직, 세정관 상피의 증식 및 기능적 분화 과정을 매개하는 생리적 활성분자 수용체 하위의 신호전달 과정에 Src-Csk loop에 의한 조절가능성을 확인할 수 있었다.

  • PDF

개발도상국(開發途上國)에 있어서 기업(企業)의 정보수요(情報需要)

  • 테니스 J. 그로간
    • Journal of Information Management
    • /
    • v.6 no.6
    • /
    • pp.151-155
    • /
    • 1973
  • 기업체(企業體)의 정보수요(情報需要)를 충족(充足)시킨다고 하는 것은 어느 국가(國家)에서나 대단히 어려운 문제(問題)이다. 새로운 발견(發見)의 적용발명(適用發明) 및 기술전달(技術傳達)은 단순(單純)한 문제(問題)가 아니며, 과학기술정보(科學技術情報)의 협동적(協同的)인 전달(傳達)도 또한 복잡(複雜)한 문제(問題)이다. 이유(理由)는 여러 가지이다. 즉 기업(企業)이라고 하는 것은 광범위(廣範圍)하고 복합적(複合的)이며 비교적(比較的) 비조직적(非組織的)이다. 기업(企業)의 임무(任務)는 생산(生産)이며 정보(情報)에 대한 기업(企業)의 인식(認識)은 퍽 낮기 때문이다. 기업체(企業體)에 정보(情報)를 제공(提供)하는 다양(多樣)한 외적(外的)인 서어비스는 대개 제공(提供)된 자료(資料)를 평가(評價)하지도 못하고 때로는 기업체(企業體)의 신임(信任)도 얻지 못하고 있다. 개발도상국(開發途上國)에 관(關)한 한(限) 기업(企業)의 성장(성장)에 대해 과학기술정보(과학기술정보)가 담당한 정확(정확)한 역할(역할)에 관(관)해서는 아직 불확실(不確實)하다. 정확(正確)한 정보수요(情報需要)를 정(定)하기에는 너무 많은 문제(問題)들이 있다. 즉 정보(情報)의 수요(需要)는 매우 복합적(複合的)인 과정(過程)임을 인정(認定)하여야 한다. 앞으로 개발도상국(開發途上國)들은 기술협력계획(技術協力計劃)에 의거(依據)하여 과거(過去)보다도 더 정보전달(情報傳達)에 역점(力點)을 두어야 하리라 생각한다.

  • PDF

Force Control of a Pneumatic Driving System With a Long Transmission Line (전달관로를 고려한 공기압 구동장치의 힘 제어에 관한 연구)

  • Jang, J.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.3
    • /
    • pp.8-13
    • /
    • 2011
  • In the present study, a robust controller has been designed to control force for a pneumatic driving system considering the effect of a transmission line. Transfer characteristics of pneumatic transmission line should be changed according to the velocity of the air going through the transmission line. The designed controller is composed of two parts. The one is a feedback controller, which is composed of a stabilizing filter, a compensating filter of modelling error and a nominal model of the force control system, to compensate the influence of transmission line and improve the feedback characteristics of the control system, and, the other is a feedforward controller to achieve the control performance. Control results with the designed controller show that the robustness and performance of the control system are improved compared to the control results with a fixed gain controller.

A Study on the Modeling of a Position Control System with a Pneumatic Cylinder Considering Transfer Characteristics of a Transmission Line (전달 관로의 전달특성을 고려한 공기압 실린더 구동장치의 모델링에 관한 연구)

  • Kang B.S.;Jang J.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.1 no.2
    • /
    • pp.20-25
    • /
    • 2004
  • In this study, a position control characteristics of pneumatic cylinder with transmission line is analyzed. Dynamic characteristics of transmission line using compressible fluid is changed by the flowing stiles of the fluid the diameter and the length of the line. But, the effect of the change of dynamic characteristics of transmission line by the flowing states on the position control characteristics can be neglected because of the friction force of the pneumatic cylinder. So, We assume that the position control characteristics is affected by the diameter and length of the transmission line. The experimental results according to the change of parameter of the transmission line show that the relation between the parameter of the transmission line and the position control characteristics of pneumatic cylinder driving system with the transmission line.

  • PDF