• Title/Summary/Keyword: 전달용 표준

Search Result 60, Processing Time 0.032 seconds

Quantitative Determination of $UO2^{2+}$ with Modified $[Ru(v-bpy)_3]^{2+}$ Polymer Film Electrode (수식된 $[Ru(v-bpy)_3]^{2+}$ 고분자 피막전극을 이용한 U(VI)의 정량)

  • Cha, Seong-Keuck
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.1
    • /
    • pp.17-23
    • /
    • 2000
  • Electrodes of the polycationic film with electropolymerized $[Ru(v-bpy)_3]^{2+}$ having about 1:1 ratio of $PF6^-/ClO_4^-$as the doped counter ions, were modified with xylenol orange and diethylditbiocarbamate by ion exchange which had stability constant as 38.6 and 17.5 respectively. These electrodes were employed in the quantitative multiple determination of U(W) in solution. The working electrode of electrochemical cell for the analytical signal was Pt/p-$[Ru(v-bpy)_3]^{2+}$, ligand, U(VI) with Ag/AgCl reference elecrode. In the stripping voltammetry. electrode process was electron transfer controlled one and calibration curves at the ranges of $1.0{\times}10^{-3}{\sim}1.0{\times}10^{-7}$ M had excellent relationship as 0.99 and relative standard deviation as 5${\sim}$8%.

  • PDF

Ethernet Port를 이용한 차량 진단 모니터링 시스템의 설계

  • Shin, Ju-Young;Jang, Jong-wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.98-101
    • /
    • 2009
  • Recently, there is use of the vehicle network for vehicle diagnostic method and Increased use of the vehicle protocol such as (CAN(Controller Area Network), MOST, LIN, FlexRay), Distributed control and data about the vehicle are being sought methods for real-time observation and monitoring and trend tends to have gone into this. In this case of automotive diagnostic module in today, there is Primarily to use DLC(Data Link Connector)Connector called self-check terminal. Generally, vehicle Diagnoses to use DLC Connector such as OBD2(On Board Diagnostics) Through Diagnostic Module(scanner). But there limit diagnostic as engine and powertrain part, and not consider user's perspective In this paper, By designing Vehicle diagnostic monitoring system using Ethernet Port, transmit and Receives CAN protocol vehicle data, and implement Easily monitoring system that provide and Diagnoses to provide vehicle's state and information to use PC.

  • PDF

Implementation of A Vibration Notification System to Support Driving for Drivers with Cognitive Delay Impairment

  • Gyu-Seok Lee;Tae-Sung Kim;Myeong-Chul Park
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.4
    • /
    • pp.115-123
    • /
    • 2024
  • In this paper, we propose a vibration notification system that combines navigation information and wearable bands to ensure safe driving for the transportation vulnerable. This system transmits navigation driving information to a linked application, converts it into a vibration signal, and provides notifications through a wearable band. Existing navigation systems focus on providing route guidance and location information, so the driver's concentration is dispersed, and safety and convenience are deteriorated, especially for those with mobility impairments, due to standard vision and delayed recognition of stimuli, resulting in an increasingly high traffic accident rate. To solve this problem, navigation driving information is converted into vibration signals through a linked application, and vibration notifications for events, left turns, right turns, and speeding are provided through a wearable band to ensure driver safety and convenience. In the future, we will use cameras and vehicle sensors to increase awareness of safety inside and outside the vehicle by adding a function that provides notifications with vibration and LED when the vehicle approaches or recognizes an object, and we will continue to conduct research to build a safer driving environment. plan.

A Study on the e-Document Development of Parcel Service for Reliable Delivery (택배 물류 안전 배송을 위한 전자문서 개발 연구)

  • Ahn, Kyeong Rim;Park, Chan Kwon
    • The Journal of Society for e-Business Studies
    • /
    • v.21 no.2
    • /
    • pp.47-59
    • /
    • 2016
  • Parcel service is to deliver goods from one place to the designated destination requested according to user request. Parcel operations such as sorting, distributing, etc. or the managed information are heterogeneous by the companies. Additionally, it is impossible to support interoperability between companies with unformatted data of manual processing. Most parcel package boxes attached to paper typed waybill is attached is delivered to consignee. So, security problems such as personal information leaking are occurred, or extra processing time and logistics costs are needed due to wrong or the damaged information. Business environment of parcel service is rapidly changed as introducing unmanned delivery or the advanced technology such as Internet of Things. User want to know the accurate status or steps from parcel service request to delivery. To provide these requirements, the unified and integrated waybill information for reliable transportation of parcel service is needed. This information will provide to pickup or delivery carrier, warehouse or terminal, and parcel service user per pickup, transport, and delivery stage of parcel delivery service. Therefore, this paper defines the simplified and unified information model for parcel service waybill by analyzing information systems used for logistics unit processes that is occurred to parcel service, and manual work processes, and developing the relevant information of work flows occurred between business processes or transactions with the collected or processed information by from parcel service's stages. It is possible to share these standard model between business entities, and replacing paper typed waybill will improve national life safety as preventing security threats by paper typed waybill. As a result, it will promote the public interest from the stakeholder's perspective.

Development of High-Sensitivity and Entry-Level Radiation Measuring Sensor Module (고감도 보급형 방사선 측정센서 모듈 개발)

  • Oh, Seung-Jin;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.510-514
    • /
    • 2022
  • In this paper, we propose the development of high-sensitivity low-end radiation measuring sensor module. The proposed measurement sensor module is a scintillator + photomultiplier(SiPM) sensor optimization structure design, amplification and filter and control circuit design for sensor driver, control circuit design including short-distance communication, sensor mechanism design and manufacturing, and GUI development applied to prototypes consists of, etc. The scintillator + photomultiplier(SiPM) sensor optimization structure design is designed by checking the characteristics of the scintillator and the photomultiplier (SiPM) for the sensor structure design. Amplification, filter and control circuit design for sensor driver is designed to process fine scintillation signal generated by radiation with a scintillator using SiPM. Control circuit design including short-distance communication is designed to enable data transmission through MCU design to support short-range wireless communication function and wired communication support. The sensor mechanism design and manufacture is designed so that the glare generated by wrapping a reflective paper (mirroring) on the outside of the plastic scintillator is reflected to increase the efficiency in order to transmit the fine scintillation signal generated from the plastic scintillator to the photomultiplier(SiPM). The GUI development applied to the prototype expresses the date and time at the top according to each screen and allows the measurement unit and time, seconds, alarm level, communication status, battery capacity, etc. to be expressed. In order to evaluate the performance of the proposed system, the results of experiments conducted by an authorized testing institute showed that the radiation dose measurement range was 30 𝜇Sv/h ~ 10 mSv/h, so the results are the same as the highest level among products sold commercially at domestic and foreign. In addition, it was confirmed that the measurement uncertainty of ±7.4% was measured, and normal operation was performed under the international standard ±15%.

Effect of the Particle Size and Unburned Carbon Content on the Separation Efficiency of Fly ash in the Countercurrent Column Flotation (向流컬럼浮選機에서 石炭灰의 크기 및 未燃炭素 含量이 分離特性에 미치는 영향)

  • 이정은;이재근
    • Resources Recycling
    • /
    • v.9 no.6
    • /
    • pp.36-44
    • /
    • 2000
  • Fly ash was composed of the unburned carbon and mineral particles. The former was able to attach on the bubbles, while the latter was not. Therefore, it was possible to separate the unburned carbon and the mineral from fly ash using the froth flotation process. This study was carried out to evaluate the separation efficiency as a function of the ny ash particle properties in the column flotation. Separation efficiency was analyzed for various size fraction of -38 fm,38~125 fm and 1125 W, and for various fly ash samples containing 7, 11, and 20 wt% unburned carbon. For the size fractions of -38 fm containing 7 wt% unburned carbon, separation efficiency was 86ft, whereas separation efficiency was found to be 74% for the size fraction of +125$\mu\textrm{m}$ containing 20 wt% unburned carbon. The results indicated that separation efficiency increased with the decrease in the particle size and the unburned carbon content of the fly ash.

  • PDF

A Study on The Security Vulnerability Analysis of Open an Automatic Demand Response System (개방형 자동 수요 반응 시스템 보안 취약성 분석에 관한 연구)

  • Chae, Hyeon-Ho;Lee, June-Kyoung;Lee, Kyoung-Hak
    • Journal of Digital Convergence
    • /
    • v.14 no.5
    • /
    • pp.333-339
    • /
    • 2016
  • Technology to optimize and utilize the use and supply of the electric power between consumer and supplier has been on the rise among the smart grid power market network in electric power demand management based on the Internet. Open Automated Demand Response system protocol, which can deliver Demand Response needed in electric power demand management to electricity supplier, system supplier and even the user is openADR 2.0b. This paper used the most credible, cosmopolitanly proliferated EPRI open source and analysed the variety of security vulnerability that developed VEN and VTN system may have. Using the simulator for attacking openADR protocol, the VEN/VTN system that has been implemented as EPRI open source was conducted to attack in a variety of ways. As a result of the analysis, we were able to get the results that the VEN/VTN system has security vulnerabilities to the parameter tampering attacks and service flow falsification attack. In conclusion, if you want to implement the openADR2.0b protocol system in the open or two-way communication environment smart grid network, considering a variety of security vulnerability should be sure to seek security technology and services.

Fabrication of Multiple-Frequency Exposure System for In Vitro Experiment (세포 실험용 다중 주파수 동시 노출 장치 제작)

  • Kim, Tae-Hong;Seo, Min-Gyeong;Mun, Ji-Yeon;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.213-219
    • /
    • 2012
  • Recently, we are simultaneously exposed by various electromagnetic sources due to an increase of mobile communication services. However, EMF(Electric, Magnetic and Electromagnetic Field) study has been performed mainly about only single frequency. The objective of this paper is to develop an multiple-frequency exposure system for in vitro experiment. The exposure unit for in vitro experiments was designed by radial transmission line type to get broadband characteristics to generate signals of CDMA at 836.5 MHz and WCDMA at 1950 MHz frequency simultaneously. The modulated signals were delivered to the conical antenna through amplifier, digital attenuator and RF combiner. SAR values were obtained by the averaged values of 3 measured values at 9 points in petri dish using the fiber optic temperature probe. The measured return loss was under -15 dB. For 1 W input power, the mean value and standard deviation of SAR were $0.105{\pm}0.019$ for the CDMA frequency and $0.262{\pm}0.055$ for the WCDMA frequency.

Development of Portable Multi-function Sensor (Mini CPT Cone + VWC Sensor) to Improve the Efficiency of Slope Inspection (비탈면 점검 효율화를 위한 휴대형 복합센서 개발)

  • Kim, Jong-Woo;Jho, Youn-Beom
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.49-57
    • /
    • 2022
  • In order to efficiently analysis the stability of a slope, measuring the shear strength of soil is needed. The Standard Penetration Test (SPT) is not appropriate for a slope inspection due to cost and weights. One of the ways to effectively measure the N-value is the Dynamic Cone Penetration Test (DCPT). This study was performed to develop a minimized multi-function sensors that can easily estimate CPT values and Volumetric Water Content. N value with multi-fuction sensor DCPT showed -2.5 ~ +3.9% error compared with the SPT N value (reference value) in the field tests. Also, the developed multi-fuction sensor system was tested the correlation between the CPT test and the portable tester with indoor test. The test result showed 0.85 R2 value in soil, 0.83 in weathered soil, and 0.98 in mixed soil. As a result of the field test, the multi-function sensor shows the excellent field applicability of the proposed sensor system. After further research, it is expected that the portable multi-function sensor will be useful for general slope inspection.

Deriving Key Risk Sub-Clauses which the Engineer of FIDIC Red Book Shall Agree or Determine according to Sub-Clause 3.7 -based on FIDIC Conditions of Contract for Construction, Second Edition 2017- (FIDIC Red Book의 Engineer가 합의 또는 결정해야할 핵심 리스크 세부조항 도출 -FIDIC Red Book 2017년 개정판 기준으로-)

  • Jei, Jae Yong;Hong, Seong Yeoll;Seo, Sung Chul;Park, Hyung Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.239-247
    • /
    • 2023
  • The FIDIC Red Book is an international standard contract condition in which the Employer designs and the Contractor performs the construction. The Engineer of FIDIC Red Book shall agree or determine any matter or Claim in accordance with Sub-Clause 3.7 neutrally, not as an agent of the Employer. This study aimed to derive Key Risk Sub-Clauses out of 49 Sub-Clauses that the Engineer of FIDIC Red Book recently revised in 18 years shall agree or determine according to Sub-Clause 3.7 using the Delphi method. A panel of 35 experts with more than 10 years of experience and expertise in international construction contracts was formed, and through total three Delphi surveys, errors and biases were prevented in the judgment process to improve reliability. As for the research method, 49 Sub-Clauses that engineers shall agree on or determine according to Sub-Clause 3.7 of the FIDIC Red Book were investigated through the analysis of contract conditions. In order to evaluate the probability and impact of contractual risk for each 49 Sub-Clause, the Delphi survey conducted repeatedly a closed-type survey three times on a Likert 10-point scale. The results of the first Delphi survey were delivered during the second survey, and the results of the second survey were delivered to the third survey, which was re-evaluated in the direction of increasing the consensus of experts' opinions. The reliability of the Delphi 3rd survey results was verified with the COV value of the coefficient of variation. The PI Risk Matrix was applied to the average value of risk probability and impact of each of the 49 Sub-Clauses and finally, 9 Key Risk Sub-Clauses that fell within the extreme risk range were derived.