• Title/Summary/Keyword: 전단형 댐퍼

Search Result 26, Processing Time 0.028 seconds

Applicability of the Hysteretic Steel Dampers to the Shear-wall Dominant Apartment Buildings (벽식구조 아파트건물의 강재이력형 댐퍼 적용성 평가)

  • Chun, Young-Soo;Park, Ji-Young
    • Land and Housing Review
    • /
    • v.3 no.4
    • /
    • pp.407-413
    • /
    • 2012
  • In this study, the possibility of applying the damping devices to shear-wall dominant apartment buildings(SDA) was examined. In order to achieve research objectives, ASCE/SEI 7-10 design procedure for structures with damping systems applied to four representative apartment buildings which are under design or previously designed with the shear-wall dominant system, and the performances of damping devices were investigated. It is shown that in order to secure the seismic performance of SDA by using dampers, the stiffness of the dampers should be very large because of the effects of shear walls with the high elastic stiffness. But since this large stiffness is highly difficult to implement in reality, prudent decisions have to be made in designing the SDA with damping system and friction dampers with the high initial stiffness are more effective than hysteretic steel dampers.

Structural Behavior of Joints between the Hysteretic Steel Damper Connector and RC Wall Depending on Connection Details (강재판형 이력댐퍼 연결부재와 RC벽체의 접합상세에 따른 구조거동)

  • Kang, In-Seok;Hur, Moo-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.737-744
    • /
    • 2012
  • Hysteretic steel damper has been applied mainly to steel buildings. However, the usage in RC buildings is rapidly increasing recently. In order to apply the steel hysteretic damper in RC buildings, supporting elements of the damper should have sufficient strength and stiffness suitable for transferring damper forces to beams and walls. But due to the inevitable damage in reinforced concrete elements due to cracking, identification of the load transfer mechanism from damper to supporting element and hysteretic characteristics of the supporting element are extremely important in evaluating the damper behavior. Experiments were carried out on connection details between RC walls and supporting elements of the steel plate typed damper such as EaSy damper. The test results showed that fracture patterns of all specimens were almost identical except in the crack number and pattern associated with shear loading condition. Among the specimens, HD-3 shoed a well distributed cracks patterns along with good performance with respect to energy dissipation capacity, stiffness deterioration, and strength degradation.

Design of Direct-Shear Mode MR Damper (전단 모드형 자성유체댐퍼의 설계)

  • Kim, Hae-Lan;Lee, Young-Shin;Lee, Eun-Yup;Lee, Gyu-Seop;Oh, Boo-Jin
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.626-631
    • /
    • 2007
  • MR(Magneto-rheological) fluid is smart material that can be changed viscosity by controlling the magnetic field. MR damper with MR fluid can control damping force. It can be used extensively many engineering structures for reducing the effect of dynamic external disturbances. There are three kinds of MR dampers, such as valve mode, direct-shear mode and squeeze mode. In this study, design process of direct-shear mode MR damper with the MR fluid gap was developed. The parameters that used in the direct-shear mode MR damper Informed from the experiment of valve mode MR damper of Lord company. Magnetic analysis with finite element method was performed to find the optimal annular gap.

  • PDF

Vibration Control of Flexible Structures Using ER Dampers (ER 댐퍼를 이용한 유연구조물의 진동제어)

  • 최승복;이재홍
    • Journal of KSNVE
    • /
    • v.8 no.2
    • /
    • pp.313-323
    • /
    • 1998
  • This paper addresses a sliding mode control of vibration in a flexible structure using ER(electro-rheological) dampers. A clamped-clamped flexible structure system supported by two short columns is considered. Three ER dampers to be operated in shear mode are designed on the basis of Bingham model of the arabic gum-based ER fluid, and attached to the flexible beam structure. After deriving the governing equation of motion and associated boundary conditions, a sliding mode controller is formulated to effectively suppress the vibration of the beam structure caused by sinusoidal and random excitations. In the formulation of the controller, parameter variations such as natural frequency deviation are treated to take into account the robustness of control system. The effectiveness of the proposed control system is confirmed by both simulation and experimental results.

  • PDF

Real-time Vibration Control of Bridges by MR damper and Lyapunov Control Algorithm (MR댐퍼 및 Lyapunov제어알고리즘을 이용한 교량 구조물의 실시간 진동제어)

  • Heo, Gwang-Hee;Jeon, Joon-Ryong;Park, Seung-Bum;Oh, Sung-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.55-61
    • /
    • 2010
  • This paper is concerned with an experimental research to random vibration control caused by external loads specially in bridges which tend to be structurally flexible. Experimenting on a reduced structure modelled on Seohae Grand Bridge, we inflicted a reduced form of El-centro wave on the model structure to a proper proportion. On the center of its middle span, we placed a shear type MR damper which was to control its vibration and also acquire its structural responses such as displacement and acceleration at the same site. The experiments concerning controlling vibration were performed according to a variety of theories including un-control, passive on/off control, and Lyapunov stability theory. Its control performance was evaluated in terms of the peak absolute displacements, the peak absolute accelerations and the total power required to control the bridge which differ from each different experiment method. Among all the methods applied in this paper, case of Lyapunov control method turned out to be the most effective to reduces of displacement and acceleration. Also, this method could to decrease consuming of external power for vibration control. Finally, it was noteworthy that Lyapunov control method was specially effective in the vibration control employing a semi-active damper such MR damper.

Performance Estimation of Semi-active Real-time Feedback Vibration Control System (준능동형 실시간 Feedback 진동제어시스템의 성능평가)

  • Heo, Gwang Hee;Jeon, Joon Ryong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.85-94
    • /
    • 2011
  • This paper is concerned to constitute a semi-active realtime feedback vibration control system and evaluate it through experiments in order to control in realtime the vibration externally generated, specially on the bridges which is structurally flexible. For the experiment of vibration control, we built a model bridge structure of Seohae Grand Bridge in a 1/200 reduced form and inflicted El-centro wave on the model structure also in a reduced force considering the lab condition. The externally excited vibration was to be controled by placing a shear type MR damper vertically on the center of bridge span, and the response (displacement and acceleration) of structure was to be acquired by placing LVDT and Accelerometer at the same time. As for the experiment concerning controlling vibration, a realtime feedback vibration control experiments were performed under each different condition largely such as un-control, passive on/off control, Lyapunov stability theory control, and Clipped-optimal control. Its control performance under different condition was quantitatively evaluated in terms of the peak absolute displacements, the peak absolute accelerations and the power required for control on the center of span. The results of experiments proved that the Lyapunov control and clipped-iptimal control were effective to decrease the displacement and acceleration of the structure, and also to decrease the power consumption to a great extent. Finally, the semi-active realtime feedback vibration control system constituted in this research was proven to be an effective way to control and manage the vibration generated on bridge structure.

The Development of Real-time Feedback Vibration Control System Using Wireless Sensor Networks (무선 센서 네트워크를 이용한 실시간 Feedback 진동제어 시스템 개발)

  • Heo, Gwang Hee;Kim, Chung Gil;Ahn, Ui Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.60-66
    • /
    • 2012
  • This paper aims to constitute a feedback vibration control system using wireless sensor networks and experiment it on a model structure to verify its effectiveness. For the purpose, we set up a feedback vibration control system composed of a wireless input/output(I/O) sensor node based on bluetooth, a home-made shear type MR damper, a shaker which generates a constant size of sine wave, and a simple beam model structure. The vibration control experiment was performed by shaking the 1/4 point of beam with a shaker. At the moment of shaking, we controled the vibration with MR damper which was placed vertically on the center of beam. Simultaneously, by acquiring acceleration response at the 2/4 point of beam, we evaluated the effectiveness of control capability. The control command was set to send a voltage signal to MR damper when the acceleration response, acquired from the wireless I/O sensor node placed at the center of beam, was more than a certain amount. Although the realtime feedback vibration control system constituted in this paper is effective only within a limited command system, it has been proven that the system was able to effectively decrease the vibration of structure by generating a control command aimed for realtime purpose. The system also showed a possibility to be used as a structural response control system adapting a variety of semi-active control algorithm.

A Study on the Seismic Performance Improvement of Mid and Low-Rise RC Grid Structures Using Steel Slab Hysteretic Damper (강재 슬래브 이력형 댐퍼(SSHD)를 이용한 중·저층 RC 격자 구조물의 내진성능 향상에 관한 연구)

  • Kim, Dong Baek;Lee, In Duk;Choi, Jung Ho
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.418-426
    • /
    • 2019
  • Purpose: After analyzing the seismic capability of low-rise RC grid structures with insufficient seismic performance, the purpose of the project is to install steel slab hysteretic dampers (SSHD) to improve the seismic performance of beams and columns, and to suggest measures to minimize damage to the structure and human damage when an earthquake occurs. Method: The evaluation of the seismic performance of a structure is reviewed based on the assumption that the seismic performance is identified for the grid-type subway systems that are not designed to be seismic resistant and the installation of an SSHD system, a method that minimizes construction period, if insufficient, is required. Result: After the application and reinforce of structure with SSHD, and the results of eigenvalue analysis are as follows. The natural periodicity of longitudinal direction was 0.55s and that of vertical direction was 0.58s. Conclusion: As results of cyclic load test of structure with SSHD, the shear rigidity of damper is 101%, the energy dissipation rate is 108% and, plastic rotation angle of all column and beam is satisfied for $I_o$ level and therefore it is judged that the reinforce effect is sufficient.

Experimental Study on Physical Characteristics of MR Fluid along Temperature Conditions (온도조건에 따른 MR 유체의 물리 특성에 대한 실험 연구)

  • Lee, Seok-Hyun;Son, June;Baek, Dae-Sung;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1247-1252
    • /
    • 2014
  • In the present study, sedimentation and shear stress of MR fluid are investigated to physical characteristics of MR fluid along temperature conditions. MR fluid is a suspension of micrometer-sized magnetic particles in a base liquid. Therefore, dispersion of MR fluid is important in the case of the design and optimization of the system using MR fluid. Due to sedimentation characteristics of MR fluid by magnetic particles, the sedimentation and shear stress of commercial MR fluid are investigated at $25^{\circ}C$ and $80^{\circ}C$ temperatures by using a forced convection oven and a viscometer. From experimental results, the sedimentation and shear stress are more affected by the temperatures of $80^{\circ}C$ than $25^{\circ}C$ and the mixing time of 5min than 10min. Shear stress by the applied current increases the shape of a quadratic equation and are lower 6-18% at $80^{\circ}C$ than $25^{\circ}C$.