• Title/Summary/Keyword: 전단강성

Search Result 693, Processing Time 0.03 seconds

Shear Stiffness of Shear connections in Full-Depth Precast Concrete Deck Bridge (프리캐스트 바닥판 교량 전단연결부의 전단강성)

  • Shim, Chang Su;Chung, Chul Hun;Kim, Chul Young;Chang, Sung Pil
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.4 s.37
    • /
    • pp.749-758
    • /
    • 1998
  • The evaluation of shear stiffness of shear connection in composite bridges with CIP concrete deck is analysed. Shear stiffness of shear connection in full-depth precast concrete deck bridges is obtained from experiments. 3-dimensional finite element analyses of push-out specimen are carried out to investigate the effects of characteristics of filling material strength in shear connection on shear stiffness and local stress distribution. The load-slip relations obtained from the analyses are compared with those of experiments. The equation of initial shear stiffness of shear connection in precast concrete deck bridge is proposed. Linear analyses are performed to evaluate the effects of the shank diameter of shear connector and the strength of mortar on the characteristics of deterioration and failure load obtained by the failure criterions of each material. The failure loads are estimated and compared with test results.

  • PDF

Relationship between shear behavior characteristics and mechanical parameters of fractures (절리면에서의 전단거동 특성과 역학적 파라미터들 간의 상관성)

  • 이종욱;이찬구;황신일;장천중;최원학
    • The Journal of Engineering Geology
    • /
    • v.3 no.1
    • /
    • pp.1-20
    • /
    • 1993
  • In this study, laboratory direct shear tests on 37 core specimens of gneiss were performed to examine the characteristics of shear behavior on fractures by using a portable direct shear box. The multi-stage shear testing method was used and normal stress applied to specimens ranges from 5.60 to $25.67kg/\textrm{cm}^2$. On the basis of test results, the empirical equations for the shear strength on fractures were suggested. The methanical parameters that can influence the shear behavior were derived and compared between each parameter. The values of shear stiffness have a trend showing rapid increase with the increase of normal stress and joint roughness coeffident, and the average value of secant shear stiffness for all specimens is about $110.68kg/\textrm{cm}^3$ under the range of normal stress applied in this test In addition, the relationship between the length of specimen and shear stiffness is inversely correlated due to the size effect. Therefore, even the specimens with the same joint roughness coeffident show the trend of decreasing shear stiffness in case of the specimens being the longer length.

  • PDF

Development of Direct Shear Apparatus with Different Loading Conditions for Rock Joints and Its Application Tests (하중조건별 시험이 가능한 암석 절리편 전단시험의 개발 및 적용시험)

  • 천병식;김대영
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.6
    • /
    • pp.161-172
    • /
    • 2000
  • 자연암석절리 및 인공 절리에 대하여 일정수직응력제어, 일정 수직하중제어 그리고 무한 강성제어가 가능한 암석 절리면 전단기 시험기를 개발하였다. 이 시험기는 전단변위에 의한 첩촉면적의 변화량을 계산하여 하중변화량을 조절하여 일정수직응력상태를 유지한다. 수직하중에 따른 시험기 강성에 의한 변화향이 제어 프로그램 내에서 제어되어 순수한 시편의 변위량을 출력하도록 하였다. 전단하중에 따른 시험기 강성에 의한 변위량은 상, 하부 전단상자의 상대변위 측정으로 최소화하였다. 전단거동 중의 자유도는 전당방향에 대하여 수평이도, 연직이동, 피칭, 롤링이 가능하도록 하였다. 자연절리면을 모사한 석고시편에 대하여 일정 수직응력 제어, 일정수직하중제어 그리고 무한 강성제어 조건으로 시험하여 제어상태 검증 및 비교를 하였다. 또한 경사각이 16.7˚와 22.6˚인 톱니형 시편에 대하여 시험한 결과 경사각 16.7˚와 22.6˚는 JRC로 10과 15를 나타내었으며, 첨두팽창각이 첨두전단강도에서 발생되며, Barton의 모델과 잘 일치함을 보였다.

  • PDF

Shear Tests Under Constant Normal Stiffness for Granite-concrete Interface (화강암 절단면과 콘크리트 부착면에 대한 일정강성도 전단시험)

  • 조천환;이명환;유한규
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.1
    • /
    • pp.5-12
    • /
    • 2004
  • The purpose of this paper is to make an understanding of fundamental mechanism of shear behaviour between rock and concrete interfaces in the pile socketed into granite. The interface of pile socketed in rock can be modeled in laboratory tests by resolving the axi-symmetric pile situation into the two dimensional situation under CNS(constant normal stiffness) direct shear condition. In this paper, the granite core samples were used to simulate the interface condition of piles socketed in granite in our country. The samples were prepared in the laboratory to simulate field condition, roughness(angle and height), stress boundary condition, and then tested by CNS direct shear tests. This paper describes shearing behaviour of socket piles into domestic granite through the analysis of CNS test results. It was found out that the peak shear strength increases with the angle of asperity and CNS value, and also the dilation increases with the angle of asperity but decreases with the CNS value.

Development of Tomographic SASW Method to Evaluate Two-Dimensional Variability of Shear Stiffness (지반 및 구조물의 이차원적 전단강성 평가를 위한 토모그래픽 SASW 기법의 개발)

  • 조성호
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.2
    • /
    • pp.29-42
    • /
    • 1999
  • The SASW (Spectral-Analysis-of-Surface-Waves) method, which evaluates the stiffness structure of the subsurface and structures nonintrusively and nondestructively, has been successfully used in the civil engineering applications. However, the SASW method assumes that the subsurface or structures consist of horizontal multi-layers, so that the method has some difficulty in continuously evaluating the integrity of a tunnel lining and a pavement system. This difficulty prevents the SASW method from being used to generate a tomographic image of stiffness for the subsurface or structures. Recently, the GPR technique which has the advantage of continuously evaluating integrity of the subsurface and structures has been popular. This advantage of GPR technique initiated the efforts to make the SASW method, which is superior to GPR and other nondestructive testing methods due to its capability of evaluating stiffness and modulus, be able to do continuous evaluation of stiffness structure, and the efforts finally lead to the development of \ulcornerTomographic SASW Technique.\ulcorner Tomographic SASW technique is a variation of the SASW method, and can generate a tomographic image of stiffness structure along the measurement line. The tomographic SASW technique was applied to the investigation of lateral variability of a sand box placed by the raining method for the purpose of verifying its effectiveness. Tomographic SASW measurements on the sand box revealed that the investigated sand box has different shear stiffness along the measurement line, which gave a clue of how to make a better raining device.

  • PDF

Measurement of Shear Contact Characteristics on Mechanical Joints (기계 조인트의 전단 컨택 특성 측정)

  • Lee, Chul-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.8
    • /
    • pp.849-855
    • /
    • 2008
  • An experimental method based on contact resonance is developed to extract the contact parameters of mechanical joints under various clamped conditions. Mechanical joint parameters of shear contact stiffness and damping were extracted for different physical joint parameters such as surface finish of the mating surfaces, the presence of lubrication, the effect of the clamping pressure, and shear load. It was found that the shear contact stiffness values decreased with increasing clamping load and increased with increasing shear loading. Contact damping ratio values were almost constant with clamping load, but decreased with increasing shear load. Moreover, rough surfaces exhibited the highest shear stiffness and contact damping compared to smooth surfaces.

Model and Method for Post-Failure Analysis of Composite Structure (복합재 구조물의 초기파손후의 거동묘사를 위한 모델과 해석방법)

  • 김용완;황창선
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.3
    • /
    • pp.506-513
    • /
    • 1992
  • 본 연구에서는 복합재 구조물에 대하여 유한요소해석법에 현상학적 모델인 전 단지연해석을 도입하여 강성저하와 모재파손을 예측하고 변형률을 매개변수로 한 Wei- bull 함수를 섬유파손해석에 도입하여 초기파손후의 거동을 묘사하고자 한다. 그리 고 면내전단하중이 작용하는 경우에 대해 전단지연해석을 수행할 수 있도록 모델링을 확장했다. 모재균열의 존재로 인한 단층의 강성변화는 실험으로 측정이 불가능하므 로 유한요소해석을 수행하여 비교하였다. 이 모델로부터 전단강성의 저하를 평가하 는 방법을 사용하였으며, 모재파손의 밀도 예측도 평균변형률 개념으로 전단효과를 고 려할 수 있도록 수정하였다. 그리고 초기파손후의 거동을 점진적으로 해석하기 위해 비선형 유한요소프그램을 작성하고, 상기의 모델을 도입하여 초기파손후의 거동을 보 다 정확히 묘사할 수 있는 방법을 제시하고 예로서 평시편에 대해 해석하고 실험치 및 타방법의 결과와 비교하였다.

액체금속로용 축소규모 면진베어링 특성시험고찰 및 적용예

  • Yoo, Bong;Lee, Jae-Han;Koo, Kyung-Hoe
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.520-525
    • /
    • 1997
  • 액체금속로의 안전성과 경제성을 향상시키는데 중요한 요소로 부각된 면진설계기술을 개발하기 위하여 고감쇠 면진베어링의 축소모델을 제작하고, 성능확인을 위한 다양한 시험을 실시하였다. 면진베어링의 성능을 나타내는 전단강성, 감쇠특성, 항복하중특성값, 전단변형능력 등에 대한 시험결과 전단강성은 목표값에 비하여 작았지만 감쇠값과 전단변형은 목표값에 근접하였다. 이를 이용한 면진 원자로건물의 지진응답을 분석한 결과 면진베어링은 건물의 지진응답 가속도를 대폭 줄여주는 것으로 나타났다.

  • PDF

Anisotropic Shear Strength of Artificially Fractured Rock Joints Under Low Normal Stress (낮은 수직응력 하에서 인공 절리면의 전단 이방성에 관한 연구)

  • 곽정열;이상은;임한욱
    • Tunnel and Underground Space
    • /
    • v.13 no.3
    • /
    • pp.169-179
    • /
    • 2003
  • Anisotropic shear strength of rock joints is studied based on the artificially fractured specimens using experimental and analytical methods. Series of direct shear tests are performed to obtain the strength, stiffness and friction angle of joints under various low normal stresses and shearing directions. The results of shear strength and stiffness show anisotropic value according to shearing direction under low normal stress specially less than 2.45 MPa. But, the effect of joint roughness on strength decreases with increasing normal stress. To estimate more effectively the peak shear strength under low normal stress, the modified Barton's equation is suggested.

Effect of Shear Wall Stiffness on Optimal Location of Core and Offset Outrigger Considering Floor Diaphragm (바닥 격막을 고려한 코어 및 오프셋 아웃리거 구조의 최적위치에 대한 전단벽 강성의 영향)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.37-47
    • /
    • 2019
  • The study purposed to investigate the optimal location of core and offset outrigger system considering floor diaphragm. To accomplish this aim, a structure design of 70 stories building was performed by using MIDAS-Gen. And the leading factors of the analysis research were the slab stiffness, the stiffness of shear wall and the outrigger position in plan. Based on the analysis results, we analyzed and studied the influences of the shear wall stiffness and the slab stiffness on optimal location of core and offset outrigger considering floor diaphragm. The results of the analysis study indicated whether the slab stiffness, the stiffness of shear wall and the outrigger position in plan had an any impact on optimal location in outrigger system of tall building. Also the paper results can give help in getting the structural engineering materials for looking for the optimal position of outrigger system in the high-rise building.