• Title/Summary/Keyword: 전기IT

Search Result 23,855, Processing Time 0.061 seconds

Electrical Insulating Characteristics of Mixing Epoxy Resin (혼합 에폭시 수지의 전기 절연특성)

  • 홍경진;정우성;이은학;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.95-97
    • /
    • 1990
  • This study investigated electrical characteristic of solids and liquid epoxy resins by measuring dielectric breakdown and dielectric loss when epoxy resins were exposed to a mixing cure. It was found that mixing epoxy resins were superior to dielectric breakdown and hardness and has shorter curing time compare with those of pure liquid epoxy resins.

Electrical Characteristics Evaluation of Transmission Line Arresters (송전선로용 피뢰기의 전기적 특성 평가)

  • Kim, Seok-Sou;Heo, Jong-Cheol;Mun, In-Wook;Oh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1498-1499
    • /
    • 2006
  • It has been reported that more than 50% of breakdown in transmission line for 154kV and above is due to lightning stroke. The flashover failure due to lightning stroke causes outage, voltage drop and instantaneous outage, Therefore line arrestors have been used in transmission line for protection from lightning stroke. In this paper, we describes electrical characteristics and performance test of line arrestor for transmission line.

  • PDF

Comprehensive Countermeasure for Safety of School Electric Installation (학교 전기설비의 안전을 위한 방안)

  • Jeon, Jun-Man;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.65-66
    • /
    • 2006
  • The speciality of education installation has to be applied to the design construction, inspection of school in the installation. But. it was applied general electric installation standards in korea. Therefore, the electric shock accidents and fire was more frequently occurred in the school than in other building. So, this paper, is proposed the comprehensive countermeasure for safety of school electric installation

  • PDF

Development of Intelligent Power Management System for Electric Energy Saving (전기에너지 절약을 위한 지능형 전원관리시스템 개발)

  • Lee, J.P.;Lim, J.Y.;Lee, I.S.;Ji, P.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.85-86
    • /
    • 2006
  • 최근 정부에서는 고효율 기기 개발과 ESCO 사업 등을 통해 낭비되고 있는 에너지를 절감하기 위해 노력하고 있고, 산업 패러다임 변화에 따른 전력 IT 기술 중요성이 상승하고 있어 디지털 멀티미디어 기술과 융합된 지능형 전원 관리시스템 개발이 필요한 실정이다. 따라서 본 연구에서는 리모콘 및 인체감지에 의한 스위치 및 콘센트의 개별/동시 제어기법을 이용한 지능형 전원 관리 시스템 개발하고 특성실험을 통해 우수성을 입증하였다.

  • PDF

Grope for Safety and Future Directions of School Electricity Facility (학교전기설비의 안전과 미래지향(未來指向) 모색(模索))

  • Jeon, Jun-Man;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.999-1001
    • /
    • 2005
  • School electricity facility is different to general electricity facility because use of immature students. But it was design, construct, manage of general electricity facility law realistically In this study, investigate the recent electrical accident data of school and the present status of electricity facility in Chonan. And grope for future directions of school electricity facility.

  • PDF

Implementation of NH800 Cross-Assembler Using ASxxxx Tool (ASxxxx Tool을 이용한 NH800 Cross-Assembler 구현)

  • Kim, Min Seong;Na, Yeoul;Kim, Seon Wook
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.194-197
    • /
    • 2011
  • 스마트 기기의 급격한 발전, 의료분야와 IT 기술의 융합, 소비자들의 높아지는 요구로 인해 8 비트 이하 마이크로 컨트롤러의 활용도가 높아질 전망이다. 이 논문에서는 EISC구조의 8 비트 마이크로 컨트롤러인 NH800의 ISA를 소개하고, 마이크로 컨트롤러를 위한 오픈소스 컴파일러인 SDCC에서 사용하는 ASxxxx Tool을 이용한 NH800 어셈블러 포팅을 제시한다.

Electrochemical Characteristics of the MFCs using the Ceramic Membrane as a Separator (세라믹막을 이용한 미생물연료전지의 전기화학적 특성 연구)

  • Lim, Ji-Young;Park, Dae-Seok;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5728-5735
    • /
    • 2015
  • This study attempts to verify the applicability of ceramic membrane as a separator by comparing the power generation characteristics in single-chamber MFCs using ceramic membranes to those in the MFCs using nafion membrane. The generated power in MFCs by using acetate as a substrate was more stable than that by using formate, propionate and butyrate, respectively. It was shown that the generated power by using formate substrate in MFCs was unstable and a little higher than that by using acetate, and the power generated by using propionate and butyrate were lower than that by using acetate. In order to find out the Pt catalyst effect, it was compared the power generated in MFCs using Pt-coated carbon cloth as electrode to that power using normal carbon cloth. The power generated in MFCs using Pt-coated carbon cloth as electrode was 1.2 times higher than that using normal carbon cloth. The Pt-coated carbon cloth was about 5 times more expensive than normal carbon cloth. It is suggested that both power generation efficiency and cost together should be considered in selecting electrodes of MFCs. It was found that the ceramic membrane was superior to nafion membrane by comparing to the power generation characteristics obtained. It was shown that average voltage values were $523.67mV{\pm}49.41mV$ by using synthetic wastewater, in MFCs of ceramic membrane as a separator. While average voltage values were $424.09mV{\pm}79.95mV$ by using synthetic wastewater, in MFCs of nafion membrane as a separator. The organic removal efficiency, 41.7% by using ceramic membrane was a little bit higher than 40.8% by using nafion membrane. This research implies ceramic membrane can be a valid alternative to nafion membrane as a separator when considering the power generation and the efficiency of organics removal.

The Design Conditions of Single Phase SRM Pole-Arcs for Blower Drives (송풍기 구동용 단상 SRM의 극호 설계 조건)

  • Lee, Jong-Han;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.125-127
    • /
    • 2003
  • The single phase switched reluctance motor(SRM) is more simpler and robust in the structure than poly phase SRM. It has the merits that it reduces the switching elements and the energy density per volume is very high. Recently, it has been researched and developed in various types and starting method due to the technique of power electronics and the computer added design. The single phase SRM is tried to apply to many industrial appliance field to substitutethe the induction motor by the single phase SRM. On the previous studies, we decided the design parameters of the single phase SRM for the blower driver to adapt the design method of the conventional machine and the poly phase SRM. In this studies, it is proposed the conditions to decide the optimal pole arcs because the stator and rotor pole arcs is very important in the characteristics of the single phase SRM. For this reason, it is analysed the characteristics of current on/off angle vs. pole arc, pole arcs vs. average torque.

  • PDF

A Development of CRU for KODAS (한국형 배전자동화용 수용가 단말제어장치 개발)

  • Kim, Jong-Soo;Kye, Moon-Ho;Oh, Sang-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.419-421
    • /
    • 1994
  • A CRU (Customer Remote Unit) for KODAS(Korea Distribution Automatic System) is presented in the paper. This equipment works as a terminal unit for the Load Control and the AMR(Automatic Meter Reading). It is composed of control, drive, input, display, and communication parts. A CRU calculates and memorizes the active power, time-of-use, and demand by the pulse from watthour meter for AMR. It also transfers the data to Center Control System. It can measure current, voltage, and power factor by adding the simple circuit. For load control, It receives the necessary informations such as the load control periods, modes, and time intervals. It controls the load until the stopping commad comes. The system reliability has been proved using a prototype.

  • PDF

Practical Analysys to enhance the Reliability of Power IT Systems during summer peak (하계피크 대비 전력IT 신뢰도 향상방안에 관한 실증분석)

  • Sa, Gwan-Joo;Kim, Chul-Sik;Lee, Soung-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.6-8
    • /
    • 2007
  • EMS, MOS, CBP시스템을 포괄하는 전력 IT시스템의 하절기 전력수요 피크대비 전력IT 신뢰도 향상방안에 대한 결과를 분석하였다. 먼저 신뢰도 향상을 위한 하절기 대비 운영계획을 수립하고 운영계획에 따라 정책과 운영 그리고 장애에 따른 유지보수를 시행하여 전력IT 종합신뢰도를 99.74%를 달성하였다. 향후에는 미흡한 점을 보완하여 2008년 하절기에는 운영기술을 향상시키고 기술축적을 통하여 전력계통운영 선진화 및 공정하고 투명한 전력거래시스템 운영에 만전을 기하고자 한다.

  • PDF