• Title/Summary/Keyword: 전기 삼투 유동

Search Result 25, Processing Time 0.021 seconds

Electrohydrodynamic Flow around a Circular-Cylindrical Rod Submerged in a Dielectric Liquid (비전도성 액체에서의 실린더 막대 주변에 생기는 전기동역학적 유체흐름)

  • Park, Hyun-Jin;Ryu, Jae-Chun;Kang, Kwan-Hyoung
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.51-54
    • /
    • 2007
  • The induced-charge electroosmosis (ICEO) is a kind of electroosmotic flow which is generated by the electrical charge induced by an externally-applied electric field. That kind of electrokinetic phenomenon provides a nonmechanical technique to handle microscale flows and particles. In this work, we report that the ICEO-like flow is observed around two kinds of circular-cylindrical rod submerged in a dielectric liquid. The conductivity of the solution is varied by adding a surfactant. The flow field is visualized by the PIV method, and average flow speed shows a remarkable dependence on electrical input frequency. Interestingly, the characteristics of the flow are quite different from the conventional ICEO with respect to the flow direction and the locations of center of vortices.

  • PDF

Simple Fabrication of Micromixer Based on Non-Equilibrium Electrokinetics in Micro/Nano Hybrid Fluidic System (단순공정으로 제작된 마이크로/나노 하이브리드 채널의 불균형 동전기성을 이용한 미세혼합기 연구)

  • Yu, Samuel;Kim, Sun-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.385-390
    • /
    • 2011
  • In this study, we developed a micromixer based on the non-equilibrium electrokinetics at the junction of a microchannel and nanochannel. Two fluid streams were mixed by an electro-osmotic flow and a vortex flow created as a result of the non-equilibrium electrokinetics at the junction of the microchannel and nanochannel. Initially, the microchannel was fabricated using Polydimethylsiloxane (PDMS) by the general soft lithography process and the nanochannel was created at a specific position on the microchannel by applying a high voltage. To evaluate the mixing performance of the micromixer, fluorescent distribution was analyzed by using the fluorescent dye, Rhodamine B. About 90% mixing was achieved with this novel micromixer, and this micromixer can be used in microsystems for biochemical sample analysis.

Electrokinetics Evaluation of Poly(styrene-ethylene-butylene-styrene) Based Anion Exchange Membrane (Poly(styrene-ethylene-butylene-styrene)계 고분자 음이온교환막 계면동전위 특성평가)

  • Son, Tae Yang;Yun, Jun Seong;Han, Song I;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.27 no.5
    • /
    • pp.399-405
    • /
    • 2017
  • The zeta potential, called an electrokinetic potential, refers to the potential difference caused by electrodynamic phenomenon, which is a value obtained by quantifying the surface charge property. The zeta potential has been actively studied for membrane fouling, confirmation of modification and substituent confirmation through surface charge analysis. The methods of measurement for zeta potential were developed on the basis of electrophoresis, electrosmosis and streaming potential. Among them, it was known that the streaming potential method was suitable for the flat sheet membrane. So, in this study, aminated poly(styrene-ethylene-butylene-styrene) membranes were prepared by introducing ammonium groups and the streaming potentials of the prepared membranes were measured by using an electrokinetic potential analyzer (SurPASS) and the results were analyzed.

A STUDY ON CHARACTERISTICS OF Ac ELECTRO-OSMOTIC FLOWS IN THE MICROCHANNEL WITH COPLANAR ELECTRODES (마이크로 채널 내 동일 평면 전극에 교류인가로 인한 유동특성 연구)

  • Heo, H.S.;Kang, S.M.;Suh, Y.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.163-166
    • /
    • 2006
  • This paper presents numerical results of fluid flows and mixing in a microfluidic device for AC electroosmotic flow (AC-EOF) with coplanar electrodes on top and bottom walls. Differently from previous EOF a channel which attached a couple of coplanar electrodes can be utilized to mix a target liquid with a reagent. In this study we propose a method of controlling fluid flows and mixing enhancement. To obtain the flow and mixing characteristics, numerical computations are performed by using a commercial code, CFX10. It was found that the flow near the coplanar electrodes is of 3-D complex flows and vortices between the other electrodes, and as a consequence the AC-electroosmotic flow on the electrodes plays an important role in mixing the liquid.

  • PDF

A Continuous Electrical Cell Lysis Chip using a DC Bias Voltage for Cell Disruption and Electroosmotic Flow (한 쌍의 전극으로 전기 삼투 유동과 세포 분쇄 기능을 동시에 구현한 연속적인 세포 분쇄기)

  • Lee, Dong-Woo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.10
    • /
    • pp.831-835
    • /
    • 2008
  • We present a continuous electrical cell lysis chip, using a DC bias voltage to generate the focused high electric field for cell lysis as well as the electroosmotic flow for cell transport. The previous cell lysis chips apply an AC voltage between micro-gap electrodes for cell lysis and use pumps or valves for cell transport. The present DC chip generates high electrical field by reducing the width of the channel between a DC electrode pair, while the previous AC chips reducing the gap between an AC electrode pair. The present chip performs continuous cell pumping without using additional flow source, while the previous chips need additional pumps or valves for the discontinuous cell loading and unloading in the lysis chambers. The experimental study features an orifice whose width and length is 20 times narrower and 175 times shorter than the width and length of a microchannel. With an operational voltage of 50 V, the present chip generates high electric field strength of 1.2 kV/cm at the orifice to disrupt cells with 100% lysis rate of Red Blood Cells and low electric field strength of 60 V/cm at the microchannel to generate an electroosmotic flow of $30{\mu}m/s{\pm}9{\mu}m/s$. In conclusion, the present chip is capable of continuous self-pumping cell lysis at a low voltage; thus, it is suitable for a sample pretreatment component of a micro total analysis system or lab-on-a-chip.