• Title/Summary/Keyword: 전기 비저항 탐사

Search Result 523, Processing Time 0.03 seconds

A Study on the Resistivity Structure in Central Myanmar Basin using DC Resistivity and Magnetotellurics (전기비저항 탐사와 자기지전류 탐사 자료를 이용한 미얀마 중앙분지 전기비저항 구조 연구)

  • Noh, Myounggun;Lee, Heuisoon;Ahn, Taegyu;Jang, Seonghyung;Hwang, InGul;Lee, Donghoon;Hwang, Seho
    • Geophysics and Geophysical Exploration
    • /
    • v.22 no.2
    • /
    • pp.62-71
    • /
    • 2019
  • We conducted DC resistivity and MT survey to obtain the resistivity structure of the central Myanmar basin. We tried to analyze the underground structure through the resistivity variation of Myanmar by performing representative geophysical survey methods because researches on the electrical resistivity structure are insufficient in Myanmar. The electrical resistivity is expected to be low considering the marine sedimentary rocks composed of shale and sandstone in this area. The DC resistivity and MT survey were carried out using SmartRho of Geolux Co., Ltd. and MTU-5A of Phoenix geophysics Ltd., respectively, to visualize the electrical resistivity structure of study area. DC resistivity and MT survey showed an electrical resistivity less than dozens of ohm-m within the depth of 100 m. In particular, MT survey data were almost similar to TM and TE modes in the frequency range above 1 Hz. The two-dimensional inversion of MT data showed a subsurface structure with low resistivity below 150 ohm-m divided into east-west direction. We confirmed that the inversions of DC resisitivity and MT data along an overlapped survey line represented similar results. In the future, considering the high electrical conductivity, it would be effective to perform DC resistivity and MT survey simultaneously to study the electrical resistivity structure of the central Myanmar basin.

충적층하부 대규모 파쇄대의 파악을 위한 물리탐사

  • 황학수;문창규;박윤성;염병우
    • Proceedings of the KSEG Conference
    • /
    • 2002.04a
    • /
    • pp.285-290
    • /
    • 2002
  • 조사지역은 전라남도 함평군 함평읍으로부터 남쪽으로 엄다면 화양리, 학야리, 성천리 일대에 발달한 충적층으로서. 이 지역에는 남서-북동방향으로 광주단층이 통과하고 있는 것으로 추정된다. 충적층 하부에 발달한 단층을 포함한 대규모 파쇄대 파악에는 지표지질조사로서 한계가 있다. 따라서 이 연구에서는 물리탐사방법을 적용하여 충적층 하부의 대규모 파쇄대의 방향과 연장성을 파악하고자 하였으며, 사용된 물리탐사법은 전기비저항 2차원탐사, 전자탐사 그리고 자력탐사이다. 전기비저항 탐사결과 충적층 내에서 남북방향의 연장성을 갖는 전기비저항 이상대가 파악되었으나, 자력탐사와 전자탐사의 측정자료에는 이 이상대에대한 반응을 관찰할 수 없었다. 이는 전자탐사의 경우, 가탐심도가 매우 작은 EM31을 사용하였고, 또한 자력탐사는 주변 지질매체 간의 대자율 차이가 없는 것에 기인한 것으로 판단된다. 따라서 향후 지하심부의 탐사를 위해 전자탐사법중 TEM 탐사를 실시할 계획이며, 또한 낮은 전기비저항 이상대의 연장성을 정확히 파악하기 위하여 기 측정된 전기비저항 탐사 측선 사이를 탐사할 예정이다.

  • PDF

3D Effect of Embankment Dam Geometry to Resistivity Data (3차원 댐구조가 전기비저항 자료에 미치는 영향)

  • Cho, In-Ky;Lee, Keun-Soo;Kang, Hye-Jin
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.4
    • /
    • pp.397-406
    • /
    • 2010
  • Resistivity method is a practical and effective geophysical technique to detect leakage zones in embankment dams. Generally, resistivity survey conducted along the crest assumes that the embankment dam has a 2D structure. However, the 3D topography of the embankment distorts significantly resistivity data measured on anywhere of the dam. This study evaluates the influence from 3D effects created by specific dam geometry and effects of water level fluctuations through the 3D finite element modeling technique. Also, a comparison between different locations of survey line are carried out, and topographic correction technique is developed for the resistivity data obtained along the embankment dam. Furthermore, using synthetic resistivity data for an embankment dam model with leakage zone, detectability of leakage zones is estimated through 2.5D inversion.

Application of Electrical Resistivity Tomography Using Single Well in Seawater Intrusion Areas (해수침투지역에서 단일 시추공을 이용한 전기비저항 토모그래피 탐사의 적용성)

  • Song, Sung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.369-376
    • /
    • 2007
  • Electrical resistivity tomography was carried out at seawater intrusion monitoring wells located at watershed in coastal areas. It is difficult to identify the characteristics of resistivity near monitoring well in case of using high signalto-noise ratio array due to the high conductivity condition in coastal aquifer although electrical resistivity survey is well adopted to delineate hydrogeological characteristics with the distribution of electrical resistivity. To improve the quality of electrical resistivity survey for two sites with seawater intrusion monitoring wells, inversion with the results of holeto-surface electrical resistivity tomography using single well was executed. The results of inversion for aquifer near wells were verified with the results of drilling log with the informations of fracture, electrical conductivity logging and normal resistivity logging. The inversion for aquifer near one of two wells was also performed at low and high tide with the same electrodes, respectively. From the inversion result, it is possible to obtain the resistivity images with high resolution and to identify the characteristics of aquifer related to seawater intrusion with tidal fluctuation. From this study, it was demonstrated that the hole-to-surface electrical resistivity tomography method accompanied with drilling log, electrical conductivity logging and normal resistivity logging would be useful to delineate the hydrogeological structures near monitoring wells in coastal areas.

Negative Apparent Resistivity in Resistivity Method (전기비저항탐사에서 음의 겉보기 비저항)

  • Cho In-Ky;Kim Jung-Ho;Chung Seung-Hwan;Suh Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.3
    • /
    • pp.199-205
    • /
    • 2002
  • In the resistivity method, the potential difference between two grounded electrodes is measured and this can be positive or negative. The apparent resistivity and the potential difference have the same polarity. Since the electric field is the gradient of the potential, the polarity of the potential difference depends on the direction of the electric field. If the direction of the vector connecting two grounded electrodes is the same to that of the electric field, the measured potential difference and the apparent resistivity become positive. If the opposite is the case, they become negative. In general, the primary electric field and the vector connecting two potential electrodes have the same direction in a surface resistivity method. In this case, the measured potential difference is always positive because the primary electric field is greater than the secondary field. Therefore, the apparent resistivity is always positive if noise is free and topography is flat. The secondary field component, however, can be greater than the primary field component along the vector connecting two potential electrodes in the cross-hole resistivity method. Furthermore, if the secondary electric field and the vector connecting two potential electrodes have an opposite direction, the apparent resistivity become negative. Consequently, the apparent resistivity may be negative in the region where the primary electric field component along the vector connecting two potential electrodes is very small.

낙동강변 충적층 시추자료와 지구물리탐사자료의 연관성

  • Ham, Se-Yeong;Hwang, Hak-Su;Kim, Hyeong-Su;Jeong, Jae-Yeol;Moon, Chang-Gyu;Cha, Yong-Hun;Jang, Seong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.552-556
    • /
    • 2003
  • 창원시 대산면 갈전리의 강변여과수 취수지역의 8개의 시추공의 시추지료로부터 파악된 지하지질과 물리탐사자료를 비교하여 둘 간의 연관성을 검토하였다. 본 연구에서는 이미 얻어진 시추공 자료와 비교ㆍ검토하기 위하여 지구물리탐사를 실시하였다. 수행된 지구물리탐사는 쌍극자배열 전기비저항 수평탐사, 슐럼버져법배열 전기비저항 수직탐사, 지하투과레이다탐사이다. 전기비저항 수평탐사에 의하면 저비저항치의 두께는 낙동강변에 가까울수록 두꺼워지는 경향성을 보이고 있다. 전기비저항 수직탐사 결과는 시추자료와 비교적 잘 일치하고 있으며 지표로부터 세립질 모래층, 중립질 모래층, 세립질 모래층의 구분이 수직탐사 결과에서 잘 나타나고 있다. 또한 GPR탐사와 전기비저항 수직탐사 결과에 의하면, 지하수면은 6m 부근에 위치하고 있음을 알 수 있다.

  • PDF

제주도 비위생매립지 주변 수리지질환경 파악을 위한 전기, 전자탐사 적용

  • 송성호;용환호;김기표;안중기;김창용
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.112-115
    • /
    • 2003
  • 쓰레기매립장의 침출수 누출 탐지를 위한 물리탐사법은 침출수의 전기전도도를 대상으로 한 전기탐사법이 주로 적용되어 왔다. 이 연구는 제주도에 위치한 비위생매립지를 대상으로 주변 수리지질환경 파악을 위한 전기비저항 탐사와 더불어 매립장 경계부와 토양층을 통한 침출수 누출 영역을 효율적으로 규명하기 위하여 다중주파수를 이용한 소형루프 전자탐사를 병행하여 수행하였으며, 아울러 오염지역의 천부 지하수 유동 방향을 추정하기 위하여 침출수의 유동에 의해 발생될 수 있는 자연전위를 모니터링 하였다. 전기비저항 탐사 및 자연전위 모니터링 결과 매립지 주변을 통한 침출수의 누출 가능성은 거의 없는 것으로 나타났으며, 이는 주변 하천에서 정기적으로 실시한 수질 분석 결과와 일치된다. 또한 소형루프 전자탐사 자료에 대하여 공간 필터링 및 1차원 역산법을 적용한 결과 매립장 경계부의 위치 및 매립장 내부의 심도별 매립물에 의한 저비저항 이상대를 효과적으로 도출 할 수 있었다.

  • PDF

Capacitively-coupled Resistivity Method - Applicability and Limitation (비접지식 전기비저항 탐사 - 적용성과 한계)

  • Lee Seong Kon;Cho Seong-Jun;Song Yoonho;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.1
    • /
    • pp.23-32
    • /
    • 2002
  • Capacitively-coupled resistivity (CCR) system is known to be very useful where galvanic contact to earth is impossible, such as the area covered with thick ice, snow, concrete or asphalt. This system injects current non-galvanically, i.e., capacitively to earth through line antenna and measures potential difference in a same manner. We derived geometric factor for two types of antenna configuration and presented the method of processing and converting the data obtained with CCR system suitable to conventional resistivity inversion analysis. The CCR system, however, has limitations on use at conductive area or electrically noisy area since it is very difficult to inject sufficient current to earth with this system as with conventional resistivity system. This causes low SM ratio when acquiring data with CCR system and great care must be taken in acquiring data with this system. Additionally the uniform contact between line antennas and earth is also crucial factor to obtain good S/N ratio data. The CCR method, however, enables one to perform continuous profiling over a survey line by dragging entire system and thus will be useful in rapid investigation of conductivity distribution in shallow subsurface.

Verification of Reinforcement with Grouting Materials in Reservoir Dike using Electrical Resistivity Tomography (전기비저항 토모그래피를 이용한 저수지 제체 그라우팅 효과 검증)

  • Song, Sung-Ho;Yong, Hwan-Ho;Lee, Gyu-Sang;Woo, Myung-Ha
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.73-78
    • /
    • 2006
  • To verify reinforcing effect of grouting materials on the water leakage region in dike, we performed various hydraulic test and we also applied electric resistivity survey including electrical resistivity tomography(ERT) to see resistivity variation before and after grouting. As the results of dipole-dipole array survey along dike, resistivity distribution after grouting was without noticeable spatial variation. Long term resistivity monitoring results at dike with Schlumberger array electric resistivity survey showed that the decreasing region of apparent resistivity and one dimensional inversion results were the occupied region by grout after grouting. From the ERT using check holes to inspect the effect of grouting, we could find that the ERT is quite effective to evaluate spatially grout region in dike.

  • PDF

Inversion of Time-domain Induced Polarization Data by Inverse Mapping (역 사상법에 의한 시간영역 유도분극 자료의 역산)

  • Cho, In-Ky;Kim, Yeon-Jung
    • Geophysics and Geophysical Exploration
    • /
    • v.24 no.4
    • /
    • pp.149-157
    • /
    • 2021
  • Given that induced polarization (IP) and direct current (DC) resistivity surveys are similar in terms of data acquisition, most DC resistivity systems are equipped with a time-domain IP data acquisition function. In addition, the time-domain IP data include the DC resistivity values. As such, IP and DC resistivity data are intimately linked, and the inversion of IP data is a two-step process based on DC resistivity inversions. Nevertheless, IP surveys are rarely applied, in contrast to DC resistivity surveys, as proper inversion software is unavailable. In this study, through numerical modeling and inversion experiments, we analyze the problems with the conventional inverse mapping technique used to invert time-domain IP data. Furthermore, we propose a modified inverse mapping technique that can effectively suppress inversion artifacts. The performance of the technique is confirmed through inversions applied to synthetic IP data.