• Title/Summary/Keyword: 전기 근육 자극

Search Result 102, Processing Time 0.026 seconds

The Effect of Electrical Muscle Stimulation Therapy on Chronic Knee Pain and Depression for Aged (전기 근육자극요법이 노인의 만성무릎통증과 우울에 미치는 효과)

  • Sok, So Hyune R.;Kim, Il Won;Kim, Kwuy Bun
    • Korean Journal of Adult Nursing
    • /
    • v.18 no.2
    • /
    • pp.223-230
    • /
    • 2006
  • Purpose: This study was to examine the effect of electrical muscle stimulation therapy on chronic knee pain and depression for the aged. Method: Design was one-group pretest-posttest design. Samples were 32 elderly of 60 years old and above with chronic knee pain and depression. Measures were the S-F McGill Pain Questuionnaire for chronic knee pain and the Korean Elderly Depression Scale for depression. Electrical muscle stimulation therapy, experimental treatment, was applied for 12 weeks, 3 times/week, 15 min/time. Data were collected from January 2005 to May 2005. Data were analyzed using SPSS PC+ 12 version. Results: After receiving electrical muscle stimulation therapy, chronic knee pain (t=-88.034, P=.000) and depression (t=-114.659, P=.000) were significantly decreased. Conclusion: Electrical muscle stimulation therapy can be a better effective primary nursing intervention on chronic knee pain and depression for community dwelling elders.

  • PDF

Properties of the Arterial Pressor Response Induced by Stimulation of the Ventral Root Afferent Fibers in the Cat (고양이 척수 전근내 감각신경 자극으로 유발된 승압반응의 생리학적 특성)

  • Kim, Jun;Seoh, Sang-Ah;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.23 no.1
    • /
    • pp.129-138
    • /
    • 1989
  • In an attempt to characterize the ventral root afferent fibers, arterial blood pressure responses to stimulation of the ventral root (VR) were observed in anesthetized cats. Effects of the morphine administered either intravenously or direct spinally and of the spinal lesions on the pressor responses were compared. Followings are the results obtained. 1) Stimulation of the VR with C-strength, high frequency stimuli evoked a marked pressor response. No depressor response, which had been reported during peripheral nerve stimulation, was observed during VR stimulation with low frequency. 2) Acute cervical spinalization abolished the pressor response, indicating the involvement of supraspinal mechanism. 3) The ascending spinal pathways of the pressor response were located in the dorsolateral funiculus bilaterally. 4) Intravenously administered morphine exaggerated the pressor response to VR stimulation, while direct spinally administered morphine suppressed it. From the above results it was concluded that the ventral root afferent fibers have more similar properties to muscular C-afferent fibers than to cutaneous C-fibers.

  • PDF

Analysis of body surface temperature by Pulsed Magnetic Fields system for evaluation of therapeutic effect of Delayed Onset Muscle Soreness (지연성 근육통증 회복 평가를 위한 경혈 부위에서의 자기장자극에 대한 체열변화 분석)

  • Lee, Na-Ra;Lee, Seung-Wook;Kim, Young-Dae;Kim, Soo-Byeong;Lee, Kyong-Joung;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.3
    • /
    • pp.645-653
    • /
    • 2011
  • The aim of this study was to develop a Pulsed Magnetic Fields(PMFs) system which can produce effects locally and simulate muscular tissues equally. To evaluate the PMFs system we caused DOMS(Delayed Onset Muscle Soreness) to subjects in biceps of the arm. Then, we stimulated acupoint HT2 using PMFs(20 minutes) and TEAS(20 minutes) for 2 days. The other subjects did not stimulate. Then we checked body surface temperature in biceps of the arm. All subjects had an asymmetrical body surface temperature in biceps after exercise(Non-stimulation group=$2.00{\pm}1.16^{\circ}C$, TEAS group=$1.73{\pm}0.52^{\circ}C$, PMFs group=$1.48{\pm}0.51^{\circ}C$). After 1st stimulation all subjects had decreased temperature differences(Non-stimulation group=$1.37{\pm}0.71^{\circ}C$, TEAS group=$1.08{\pm}0.43^{\circ}C$, PMFs group=$1.23{\pm}0.15^{\circ}C$). PMFs group had a symmetry body surface temperature after 24 hours($0.05{\pm}0.06^{\circ}C$) and TEAS group had that after 48 hours($0.1{\pm}0.08^{\circ}C$). Non-stimulation group did not recovery after 48 hours($0.37{\pm}0.06^{\circ}C$). Therefore, PMFs on acupoint had an therapeutic effect in DOMS.

Effect of Electrical Stimulation on Physico-Chemical Properties of Korean Native Cattle Meat (전기자극이 저장중 한우육의 이화학적 변화에 미치는 영향)

  • Shin, Heuyn-Kil;Oh, Eun-Kyong;Park, Jong-Heum;Kim, Cheon-Jei;Huh, Jeong-Weon
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.252-257
    • /
    • 1993
  • Nine Korean native cattle were purchased from a beef cattle farm. Immediatly after slaughtering and skinning, each carcass was split into left and right sides and the one half was kept as a control, the other one was electrically stimulated by using 400v stimulator for 1 min. All samples were analyzed for shear force value, ATP and biochemical changes to investigate the effect of electrical stimulation during storage at $5^{\circ}C\;and\;15^{\circ}C$. The amount of lactate of electrically stimulated (E.S.) meat showed a rapid increment compared with that of control (p<0.01). E.S. treatment caused a rapid drop of pH value. Initial pH decreased from 6.85 to 6.38 in M. semitendinosus and from 7.0 to 6.58 in Triceps brachii by E.S. treatment (p<0.01). Electrically stimulated muscle showed decrease (34.67%) in ATP to $5.74{\mu}mole/g$ from $8.78{\mu}mole/g$ of unstimulated meat. ATP of the electrically stimulated muscle stored at $15^{\circ}C$ and $5^{\circ}C$ was degraded faster than that of control until 6 hours post-mortem (p<0.05). The tenderness of meat after aging was improved significantly by electrical stimulation with lower shear force value than that of untreated meat (p<0.01).

  • PDF

Residual Neuromuscular Sensing Platform Development using Sensor of Nerve Stimulation Response Measurement during Anesthesia (신경자극반응 측정 센서를 이용한 마취 시 잔여근이완 감지 플랫폼 구현)

  • Shin, Hyo-Seob;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.459-462
    • /
    • 2010
  • Response to nerve stimulation platform for implementing measures to detect finger movement has been functioning as an important factor. This stimulated finger on the nerve and muscle responses would vary. In other words, the finger movement of the muscle response to nerve stimulation and sensing Actuator for the H/W development is needed. In addition, a low power embedded CPU based on the top was used. H/W configuration portion of the isolation power, constant current control, High impedance INA, amplifier parts, and the stimulus mode and the Micro-control the status of current, AD converter Low Data obtained through the processing system is implemented.

  • PDF

Sucrose-Gap Apparatus를 이용한 말초신경계의 Opiate수용체 검색법

  • ;George B. Frank
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1992.05a
    • /
    • pp.40-40
    • /
    • 1992
  • opiate receptor들의 중추신경계에서의 분포 및 작용에 관한 실험물은 널리 알려져 있어 그 웅용 방법도 많이 있으나, 말초에 있는 opiate receptor의 존재 및 약물작용을 관찰하는 실험은 별로 알려진 것은 없다. 저자는 214mM의 sucrose 용역을 이용하여 전기적 자극에 따른 말초신경 및 말초조직(근육)에서의 opiate receptor애 대한 작용을 관찰하였다. 실험은 3분류의 약물을 이용하였다. 1) Pure agonists: morphine, meperidine, methadone, 2) Agonist-antagonist: buprenorphine 3) Pure antagonist: naloxone 위의 약물들을 이용하여 excitable cell membrane(좌골신경 및 근육)에서 일어나는 potential의 변화를 관찰하여 다음과 같은 결과를 얻었다. a. pure agonists들은 좌골신경 및 근육절편에서 action potentials을 의의있게 억제시켰으며 meperidine이 가장 강한 작용을 보였다. b. 이들의 작용은 naloxone 투여로 억제되었다. c. Agonist-antagonist인 buprenorphine은 투여용량 및 동시 투여한 pure agonist의 종류에 따라 biphasic pattern을 나타내었다. d. opiates 작용기전 및 약물작용장소를 알고자 두 종류, 즉 single 및 double technique을 사용하여 비교하였다.

  • PDF

A Study on Neuroactive Response Measurement Platform using Mechano Sensor (Mechano sensor를 이용한 신경자극반응 측정 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.198-201
    • /
    • 2012
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls. The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation, Train-of-four, and Double Burst Stimulation in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF

A Study on Neuroactive Response Sensing Platform after Injection of Muscular Relaxants (근 이완제 투여에 따른 신경 자극 반응 감지 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.331-334
    • /
    • 2011
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls.The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation(STS), Train-of-four(TOF), and Double Burst Stimulation(DBS) in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF

Effects of Electrical Stimulation and Storage Temperature on ATP-related Compounds of Korean Native Cattle M. Semitendinosus Muscles. (전기자극방법 및 저장온도가 한우 M. Semitendinosus muscle의 핵산관련물질 생성 및 분해에 미치는 영향)

  • Shin, Heuyn-Kil;Lee, Yong-Woo;Oh, Eun-Kyong;Choi, Do-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.343-347
    • /
    • 1994
  • The effects of low and high-voltage-electrical-stimulation and storing temperature on concentration of adenosine triphosphate (ATP) related compounds were studied in M. Semitendinosus muscles from Korean native cattle. Seven beef carcasses were split, the one side was electrically stimulated for 1 minute by using stimulator adjusted to 400 V/60 Hz as high voltage or to 110 V/60 Hz as low voltage while the other side served as an unstimulated control. Both side samples were incubated at $5^{\circ}C\;and\;15^{\circ}C$ for 3 days. During storage, the concentration of ATP and its breakdown products were measured as a function of time. Significant differences (p<0.05) were observed in the variance of ATP, adenosine diphosphate (ADP) and inosine monophosphate (IMP) levels between low-or high-voltage-electrically stimulated muscles and unstimulated control at just after post-stimulation. The decomposition of adenosine compounds and the production of inosine compounds of low-voltage-electrically stimulated muscles were advanced more slowly than those of high-voltage-treatment muscles. With increasing storage time, the influence of electrical stimulation on changes of ATP related compounds in meat was decreased, but storing temperature begin to affect their concentration. Significant difference in the Hypoxanthine levels (p<0.05) was found of sample stored for 48 hours at $15^{\circ}C$ from samples stored at $5^{\circ}C$ regardless of electrical stimulation treatemt. IMP and inosine values in electrically stimulated muscles, higher than of a control during 72 hours of storage, indicated rapid production of flavor compounds in beef.

  • PDF

FES Exercise Program for Independent Paraplegic Walking (하반신 마비환자의 FES 독립보행을 위한 근육 강화 프로그램)

  • Khang, Seon-Hwa;Khang, Gon;Choi, Hyun-Joo;Kim, Jong-Moon;Chong, Soon-Yeol;Chung, Jin-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.69-80
    • /
    • 1998
  • This research was designed to investigate how the exercise program affects paraplegic standing and walking employing functional electrical stimulation(FES). Emphasis was also given to fatigue of major lower extremity muscles induced by different types of electrical stimulation. We applied continuous and intermittent rectangular pulse trains to quadriceps of 10 normal subjects and 4 complete paraplegic patients. The frequencies were 20Hz and 80Hz, and the knee angle was fixed at 90$^{\circ}$and 150$^{\circ}$to investigate how muscle fatigue is related to muscle length. The knee extensor torque was measured and monitored. We have been training quadriceps and gastrocnemius of a male paraplegic patient by means of electrical stimulation for the past two year. FES standing was initiated when the knee extensors became strong enough to support the body weight, and then the patient started FES walking utilizing parallel bars and a walker. We used an 8-channel constant-voltage stimulator and surface electrodes. The experimental results indicated that paralyzed muscles fatigued rapidly around the optimal length contrary to normal muscles and confirmed that low frequency and intermittent stimulation delayed fatigue. Our exercise program increased muscle force by approximately 10 folds and decreased the fatigue index to half of the initial value. In addition, the exercise enabled the patient to voluntarily lift each leg up to 10cm, which was of great help to the swing phase of FES walking. Both muscle force and resistance to fatigue were significantly enhanced right after the exercise was applied every day instead of 6 days a week. Up to date, the patient can walk for more than two and half minutes at 10m/min while controlling the on/off time of the stimulator by pushing the toggle switch attached to the walker handle.

  • PDF