Evaluation of Safety Characteristic in Chemical Decontamination at Extremely Severe Condition of Stainless Steels for Coolant Pump (가장 가혹한 조건에서 화학 제염한 경우 냉각재 펌프용 스테인리스강의 안정성 평가)

  • Kim, Seong-Jong;Jang, Seok-Ki;Kim, Ki-Joon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.253-259
    • /
    • 2006
  • This paper investigated on anti-corrosion characteristic in chemical decontamination at extremely severe condition{process model-2) of stainless steels used with reactor coolant pump. The electrochemical properties of stainless steel{STS) 304 with the lapse qf cycle is better than those of STS 415 and STS 431. The STS 304 in process model-1 and process model-2 present the lowest weightloss ratio. The experiment results for STS 304, STS 415, and STS 431 in process model-2 solution, it was ascertained that weightloss ratio of process model-2 solution for process model-1 solution show 2..908, 2.572, and 2.370 times, respectively. The reason suggests that process model-2 is higher concentration of chemical and temperature compare to process model-1.

  • PDF

Modeling and Validation of a Liquid Propellant Supply System in Steady States (액체 추진제 공급시스템의 정특성 모델링 및 검증)

  • Lee, Juyeon;Ki, Wonkeun;Huh, Hwanil;Roh, Tae-seong;Lee, Hyoung Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.6
    • /
    • pp.143-154
    • /
    • 2020
  • The mathematical modeling applying experimental coefficients to a conventional model was validated through the hydraulic test for the components and the full system of a small-sized liquid rocket engine's propellant supply system. According to the simulations, pressures difference for the fluid resistance components and the pump were mainly predicted. In order to improve the modeling accuracy, the loss coefficients obtained by the empirical method were applied to the modeling. Based on the governing equation of the flow or the well known empirical equation, the method of deriving the empirical coefficients was summarized and the coefficients were presented for the commercial products used in this study. The prediction results by modeling were in good agreement with the experimental data. Through the comparison with the experimental data, the factors affecting the accuracy of the simulation were analyzed and improving methods of the accuracy was proposed.

A Study of Closed OTEC Power Plants (폐쇄형 해양온도차발전 사이클에 관한 연구)

  • Shin, Sang-Ho;Jung, Dong-Soo;Kim, Chong-Bo;Seo, Tae-Beom;Chun, Won-Gee;Auh, P. Chung-Moo
    • Solar Energy
    • /
    • v.17 no.4
    • /
    • pp.23-33
    • /
    • 1997
  • In this paper, performance of various working fluids is evaluated for the closed Ocean Thermal Energy Conversion(OTEC) power plant operating on Rankine cycle. The evaporator and condenser are modeled via UA and LMTD method while turbine and pump are modeled by specifying isentropic efficiencies. R22, Propane, Propylene, R134a, R125, R143a, R32, R410A and Ammonia are used as working fluids. Results show that newly developed fluids such as R410A and R32 that do not cause stratospheric ozone layer depletion perform as well as R22 and ammonia. The superheat at the evaporator exit and subcooling at the condenser exit do not affect the performance of the simple OTEC power cycle. Turbine efficiency and heat exchanger size influence greatly the performance of the Rankine cycle. Finally, it was shown that closed OTEC power plants can practically generate electricity when the difference in warm and cold sea water inlet temperatures is greater than $20^{\circ}C$.

  • PDF

Experimental Study on the Performance Characteristics of a Scroll Expander for 1kW-class Organic Rankine Cycle (1kW급 유기랭킨사이클용 스크롤 팽창기의 성능 특성에 관한 실험적 연구)

  • Kim, Dokyun;Yun, Eunkoo;Yoon, Sang Youl;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.41-48
    • /
    • 2015
  • The performance characteristics of a scroll expander is the most important variable for the performance of organic Rankine cycle system. In this paper, the performance characteristics of a scroll expander was identified using 1kW class organic Rankine cycle system with various operating conditions. The ORC system is composed of an evaporator, a scroll expander, a condenser and a working fluid feed pump that uses R245fa as working fluid. The hot water temperature was controlled from $80^{\circ}C$ to $115^{\circ}C$ by the 50kW-class electric water-heater. The maximum isentropic efficiency of the scroll expander was measured about 77%, and the shaft power was measured from 0.5 kW to 1.8 kW according to heat source temperatures.

$CO_2$ Refrigeration, Air Conditioning and Heat Pump Technology Development in Europe

  • Pettersen, Jostein;Neksa, Petter
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.7
    • /
    • pp.53-64
    • /
    • 2002
  • $CO_2$ 20세기 초 천연 냉매 $CO_2$는 광범위하게 사용되었지만 프레온계 냉매의 출현으로 1940년경부터 $CO_2$냉매는 사용이 제한되었다. 그러나 반 세기 동안 사라졌던 $CO_2$냉매는 1980년 후반에 노르웨이 과학 기술대학 (NTNU)과 북구 최대 민간연구소 (SINTEF)의 Lorentzen 교수에 의해 $CO_2$천연 냉매 사용을 재고하게 되었다. 프레온계 냉매의 환경적 논쟁이 쟁점이 되면서 천연 냉매 사용을 재고하게 되었다. 특히 비가연성과 비유독성으로 인한 $CO_2$냉매가 주목을 받고 있다. 초월임계 사이클레서의 고압 제어에 대한 새로운 개념은 Lorentzen 교수와 동료 연구원에 의해서 특허로 제안되었다. 이에 대한 상업적 권리를 Norsk Hydro사는 1990년에 얻었고,1990년대 초반에 NTNU/SINTEF의 공동 연구개발 프로그램을 통해 기술 경쟁력과 실현 가능성이 검증되었다. 현재 연구소에서는 최초로 초월임계 $CO_2$사이클을 이용한 상업용 온수 열펌프 시스템, 2003년 시작할 연료전지 전기 자동차에 대한 연구를 수행하고 있다. NTNU/SINTEF에서 개발된 $CO_2$기술은 Hydro-SINTEF 공동 벤처 기업인 Shecco기술회사를 통해 제조업자에게 허가된다. 본 고에서는 NTNU/SINTEF에서 수행하였거나 수 중인 과제들을 중심으로 유럽의 $CO_2$시스템의 결과와 주요 개발 범위를 정리하였으며, 특히 작동유체로서의 $CO_2$냉매의 특징을 간단히 설명하고, 온 수 열 펌프, 자동차용 공조기 및 열 펌프, 상업 냉동기 등이 기술되었다. 그 외 압축기 위주의 요소기술 개발에 관한 내용도 기술되었고, 차세대 기술 경향과 전망에 대해서도 제시되었다. 제시되었다.성균 350$\times$$10^4$ CFU균, 방선균 434$\times$$10^4$ CFU균, 진균 676$\times$$10^4$ CFU균으로 진균의 개체수가 비교적 높게 나타났으며, 비산불지역에서는 호기성균 328$\times$$10^4$ CFU균, 방선균 319$\times$$10^4$ CFU균, 진균 461$\times$$10^4$ CFU균으로 진균의 개체수가 높게 나타났다. 토양미생물은 호기성균, 방선균, 진균 모두 비산불지역 보다 산불지역에서 많이 나타났다. 본 조사지역에서 호기성균은 활엽수림보다 침엽수림에서 많게 나타났으며, 방선균과 진균은 침엽수림보다 활엽수림에서 많이 나타났다.효과와 이를 이용한 자기냉동의 방법 그리고 최근에 이루어진 새로운 진전에 대해 소개하고 공기조화 및 냉동분야에의 적용 가능성을 전망해 보고자 한다.및 도입 등 선주들에게 다양한 선박건조자금을 제공하여 내수기반 확충에도 노력해야 할 것 이다.있었다., 인삼이 성장될 때 부분적인 영양상태의 불충분이나 기후 등에 따른 영향을 받을 수 있기 때문에 앞으로 이에 대한 많은 연구가 이루어져야할 것으로 판단된다.태에도 불구하고 [-wh]의미의 겹의문사는 병렬적 관계의 합성어가 아니라 내부구조를 지니지 않은 단순한 단어(minimal $X^{0}$ elements)로 가정한다. 즉, [+wh] 의미의 겹의문사는 동일한 구성요 소를 지닌 병렬적 합성어([$[W1]_{XO-}$ $[W1]_{XO}$ ]$_{XO}$)로 그리고 [-wh] 의미의 겹의문사는 중복된 발은을 지닌 한 단어로 ([W]$_{XO}$ )

  • PDF

Design and Construction of a Bottoming Organic Rankine Cycle System for an Natural Gas Engine (가스엔진용 유기랭킨사이클의 설계 및 제작)

  • Lee, Minseog;Baek, Seungdong;Sung, Taehong;Kim, Hyun Dong;Chae, Jung Min;Cho, Young Ah;Kim, Hyoungtae;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.65-72
    • /
    • 2016
  • ORC system was designed and constructed for utilizing the heat of the exhaust gas and coolant released from the gas engine which was modified to use natural gas as a fuel. In this paper the components of the ORC system were designed and manufactured based on measured data of the gas engine. The components are composed of two plate heat exchanger, the 5kW-class expander and multi stage centrifugal pump. The thermodynamic performance of the ORC system was analyzed by using the electric heater. Also, the developed ORC system was implemented to modified natural gas engine. Two gas engines were used to supply heat to the ORC system. As a result of test bench, when the heat source temperature is $110^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 5.22kW, 7.41, 9.09%. As a result of field test, when the heat source temperature is $86^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 2kW, 3.75, 6.45%.