• Title/Summary/Keyword: 전기체

Search Result 3,393, Processing Time 0.034 seconds

전력케이블 특성분석 일반론 및 외국 분석 사례

  • 한재흥;김상준;권오형;서광석
    • 전기의세계
    • /
    • v.45 no.11
    • /
    • pp.3-15
    • /
    • 1996
  • 본 고에서는 전력케이블의 절연체 특성분석의 필요성 및 외국 분석사례와 고분자 특성과 절연성능과의 관계 등에 대하여 언급하고자 한다. 고분자 절연체의 특성분석 방법 및 주의사항 등에 대하여는 다음 기회에 발표하기로 한다.

  • PDF

A Study on the Test Load Simulation Technique for T-50 Full Scale Durability Test (T-50 전기체 내구성시험 시험하중 설계기술 연구)

  • Jung, Jae-Kwon;Lee, Kee-Bhum;Yang, Myung-Seog;Shul, Chang-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.82-87
    • /
    • 2004
  • The general requirements to achieve the structural integrity of the airframe are described in the military specification, MIL-HDBK-1530. One of these requirements is the durability and damage tolerance of the airframe, which should be shown through the analysis and test based on the related specifications. This paper describes the full scale durability test load simulation to evaluate the structural safety and durability of the advanced trainer, T-50. The test load simulation was performed according to the procedure in the military specification and the KAF contract requirements. The durability test design technique which involve the floating test set-up, the optimal test load simulation method, and the 6-DOF test article balance method to secure the real flight conditions as many as possible. It was confirmed that this method will be available in a similar full-scale airframe structural test in future.

Numerical Flow Simulation of a UH-60A Full Rotorcraft Configuration in Forward Flight (전진비행하는 UH-60A 헬리콥터 전기체 형상에 대한 유동 해석)

  • Lee, Hee-Dong;Kwon, Oh-Joon;Kang, Hee-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.6
    • /
    • pp.519-529
    • /
    • 2010
  • In the present study, unsteady calculations have been performed to simulate flows around a UH-60A full configuration including main rotor, fuselage, and tail rotor. A flow solver developed for helicopter aerodynamic analysis was used for the simulation of the complete helicopter in high-speed and low-speed forward flight. Unsteady vibratory loads on the main rotor blades were compared with flight test and other calculated data for the assessment of the present flow solver. Aerodynamic interaction of the three components of the helicopter was investigated by comparing with the results of main-rotor-alone, main rotor and fuselage, and tail-rotor-alone configurations. It was found that the existence of the fuselage has an effect on the normal force distribution of the main rotor by varying downwash distribution on the rotor disc, and tip vortices trailed from the main rotor strongly interact with the tail-rotor.

Fabrication and Evaluation of Hybrid Scaffold by Nano-Micro Precision Deposition System (나노-마이크로 정밀 분사 시스템을 이용한 하이브리드 인공지지체의 제작 및 평가)

  • Ha, Seong-Woo;Kim, Jong Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.8
    • /
    • pp.875-880
    • /
    • 2014
  • Recently, three-dimensional scaffolds and nanofibers are being developed for bone tissue regeneration. In this study, we fabricated a hybrid scaffold using a nano-micro precision deposition system. The fabrication process involved the application of the solid freeform fabrication (SFF) technology and electrospinning. The hybrid scaffolds were combined using micro scaffolds and nanofibers. The nanofibers were deposited on each layer of the micro scaffolding using the electrospinning process. The micro scaffolds were fabricated using the SFF technology at a temperature of $100^{\circ}C$, pressure of 650 kPa, and scan velocity of 250 mm/s. Nanofiber fabrication was conducted by means of electrospinning using the flow rate, solution concentration, distance from the tip to the collector (TCD), and voltage. The nanofibers were fabricated using a flow rate of 0.1 ml/min, voltage of 5 kV, TCD of 1 mm, and 10 wt% of solution concentration. MG-63 cells were seeded into the hybrid scaffold for the purpose of its evaluation.

일본전기학회의 현황 - 일본시찰을 마치고

  • 한만춘
    • 전기의세계
    • /
    • v.23 no.1
    • /
    • pp.26-28
    • /
    • 1974
  • 본인는 문교부에서 파견한 중화학공업분야교수 일본시찰단의 일원으로서 9월 17일부터 10월 14일까지 일본각지의 주요대학, 연구소 및 기업체를 시찰하였으며 일본전기학회를 방문한바 있다. 여기서는 일본전기학회의 현황을 소개하기로 한다.

  • PDF

Fabrication and analysis of electrochemical performance for energy storage device composed of metal-organic framework(MOF)/porous activated carbon composite material (금속유기골격체(Metal-organic Framework) 소재가 첨가된 다공성 활성탄소 복합재료 전극 기반의 에너지 저장 매체 제조 및 전기화학적 특성 분석)

  • Lee, Kyu Seok;Jeong, Hyeon Taek
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.260-267
    • /
    • 2020
  • In this study, supercapacitor based on the all solid state electrolyte with PVA(polyvinyl alcohol), ionic liquid as a BMIMBF4(1-buthyl-3-methylimidazolium tetrafluoroborate) and activated carbon/Ni-MOF composite was fabricated and characterized its electrochemical properties with function of MOF. In order to analysis and comparison that electrochemical performances [including cyclic voltammetry(CV), electrochemical impedance spectroscopy(EIS) and galvanostatic charge/discharge test] of prepared supercapacitor based on activated carbon/Ni-MOF composite and all solid state electrolyte. As a result, specific capacitance of the supercapacitor without Ni-MOF was 380 F/g which value decreased to 340 F/g after adding Ni-MOF to activated carbon as a electrode material. This result exhibited that decreased electrochemical property of the supercapacitor effected on physical hinderance in the electrode. In further, it needs to optimization of the Ni-MOF amount (wt%) in the electrode composite to maximize its electrochemical performances.