• Title/Summary/Keyword: 전기집진

Search Result 252, Processing Time 0.02 seconds

The study on collection efficiency of two-stage electrostatic precipitator using non-metallic electrode for improve corrosion resistance and light weight (내부식성과 경량성 향상을 위한 비금속 재질 집진판의 2단 전기집진기 집진효율 연구)

  • An, So-Hee;Lee, Yeawan;Kim, Ye-Sle;Kim, Yong-Jin;Han, Bangwoo;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.17 no.2
    • /
    • pp.21-27
    • /
    • 2021
  • We developed non-metallic electrodes that can replace metallic electrodes of the electrostatic precipitator(ESP) for the purpose of light weight, corrosion resistance, cost reduction. We manufactured three types of collection electrodes made of stainless steel (M), Carbon ink coating layer-Plastic sheet-Carbon ink coating layer (CPC), and Plastic sheet-Carbon ink coating layer-Plastic sheet (PCP). We studied the collection efficiency of a two-stage ESP using oil mist particles with and without collection stage by changing the flow rate, the material of collection electrode, and the applied voltage of the pre-charger module and the collection module. Here we measured concentrations of particles at diameters of 0.45 ㎛ (CMD; count median diameter) and 3.0 ㎛ (MMD : mass median diameter), as well as PM2.5 and PM10. As a result of the experiment, two-stage ESP had 22~25% higher collection efficiency in PM2.5 than one-stage ESP at the same applied voltage. The difference in collection efficiency by varying the materials of collection electrodes was less than 5%. The weight of the non-metallic electrode was only one eighth the weight of the metal electrode. CPC electrode had a thickness of 0.27 mm, which was 1.5 times thinner than a thickness of PCP electrode, so when the flow rate increased, the CPC electrodes couldn't be kept at equal intervals due to the fluttering unlike PCP electrodes. In addition, the PCP-CPC collection module of the present experiment followed the theoretical efficiency based on Deutsch equation and Cochet's charging theory.

A Study on collection efficiency of two-stage electrostatic precipitator using PET-coated non-metallic electrode with respect to relative humidity (PET 코팅된 비금속 집진판을 사용한 2단 전기집진기의 상대습도에 따른 집진효율 연구)

  • Haneol Lee;Gwangtaek Lee;So-Hee An;Ye Won Park;Gunhee Lee;Kee Jung Hong;Inyong Park;Sang Bok Kim;Daehoon Park;Yeawan Lee;Dong-Keun Song;Yong-Jin Kim;Bangwoo Han;Hak-Joon Kim
    • Particle and aerosol research
    • /
    • v.19 no.3
    • /
    • pp.53-62
    • /
    • 2023
  • This study compared the collection efficiency of a two-stage electrostatic precipitator (ESP) with a lightweight PET film-coated carbon electrode collector plate, depending on the relative humidity of the exhaust gas and the applied voltage to the pre-charger. It was confirmed that the onset voltage at which corona discharge occurs decreases and the discharge current decreases at the same voltage as the relative humidity increases. On the other hand, even though there was almost no change in the diameter of the particles generated depending on the relative humidity, the efficiency was higher at the same voltage as the relative humidity increased. In addition, by applying a two-stage ESP structure, the collection efficiency was higher than that of a single-stage electrostatic precipitator under the same conditions. The ESP using the carbon electrode coated with PET film used in this study is expected to be effective in various aspects such as weight and in the current situation where environmental regulations are rapidly tightening.

Collection Characteristics of Electro-Cyclone with Charging Type (하전방식에 따른 전기싸이클론의 집진특성)

  • 여석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.463-473
    • /
    • 1999
  • The main purpose of this study is to investigate the characteristics of precharge electro-cyclone compared to those of innercharge electro-cyclone, experimentally. Especially, the experiment is executed focusing on the improvement of collection efficiency with the charging types including the experimental parameters such as the discharge electrode shapes, applied voltages and gas inlet velocities. Results show that the overall collection efficiency of precharge electro-cyclone is increased over 20% than that of the innercharge type for the same discharge electrode(ø 4 mm, screw rod) in the inlet velocity of 4 m/s, and applied voltage of 30kV. Moreover, the pressure drop of precharge type becomes 10% lower than that of the innercharge type for the inlet velocity of 12 m/s owing to the disturbance of inner vortex flow by the discharge electrode equipped in the center region of cyclone body.

  • PDF

Code and Standard Development for Equipment in Nuclear Power Plant and Fossil Power Plant (원전의 일반기계기기 기술기준 개발방향)

  • 정현섭
    • Journal of the KSME
    • /
    • v.33 no.8
    • /
    • pp.708-716
    • /
    • 1993
  • 기술기준의 개발은 원자로형의 공급국가에 따라 다양한 형태의 기술기준 적용으로 파생되는 국 산화 및 기술자립지연 등 문제를 해결하기 위하여 개발하고 있다. 일반기계기기는 전력생산과 직접 관련되면서도 ASME Sec. III의 적용을 받는 원자력기계기기와는 달리 구별되나 화력발전 용과는 사용조건이 다를 뿐 기능과 역할이 동일하다. 따라서 국내실정에 적합하면서 우수한 기 술성과 안전성을 확보할 수 있도록 일반기계기기의 기술기준을 개발하여 향후 국내 주도로 건 설되는 원전후속기 및 화력발전소에 점진적으로 활용함으로써 원전산업뿐만 아니라 화력발전산 업의 활성화에도 크게 기여해야 할 것으로 생각된다. 또한, 보일러, 터빈발전기 및 전기집진기등 금번에 기술기준개발 범위에서 제외된 기기의 기술기준도 개발하여 일반기계기기로 분류된 기 기의 실질적인 기술자립을 꾀하고 금번기술기준 제정 한 번으로 끝날 것이 아니라 기술기준의 유지관리를 위한 전담기구를 설립하여 기술기준을 지속적인 보완과 확대로 기술자립을 앞당 겨야 할 것으로 사료된다.

  • PDF

A Study on Fine Particle Removal of ESP according to $(NH_4)_2SO_4$ Injection Rate (황산암모늄 주입에 따른 전기집진기(ESP)에서의 미세분진 제거)

  • 서정민
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.505-510
    • /
    • 1998
  • This study has been carried out to investigate Electrostatic Precipitator's(ESP) performance enhancement and removal efficiency of fine particle according to (NH4)2SO4injection rate. The following conclusions are derived from the these test results : 1) For plant condition cases, according to the variation of concentration agent [(NH4)2SO4]-10ppm, when inlet dust loading was 2g/m2. And when Inlet dust loading was 3g/m", that was increased to 98 19% 99.16% 99.23%, 99.58%, 2) It Is seen from thins experiments that the increasing 30ppm concentration of (NH4)2SO4 increase the collection efficiency and fine particle omission control.

  • PDF

Experimental and Finite Difference Method(FDM) Analysis on Collection Characteristics of Electrostatic Precipitator (전기집지기 집진특성 실험 및 유한차분해석에 관한 연구)

  • 김용진;홍원석;최헌오;함병훈;민춘식;유기선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.49-56
    • /
    • 1994
  • Electrostatic Precipitators( EP ) are widely used in industry for controlling the emission of particulate pollutant Recently, a number of researches have been conducted to solve performance and reliability problems of EP, As a result of researches in the laboratory and of pilot scale, a technology of wide-pitch-spacing has been successfully applied to full scale units. It has been known that the wide-pitch-spacing can reduce the capital cost of newly installed precipitators, and the cost of rebuilding existing uints. In this paper, a systematic study was performed to develop a wide-pitch electrostatic precipitator. The study includes experimental and numerical work on the following : Particle collection characteristics for a bench-scale unit; gas flow characteristics( temperature and velocity distributions): other EP operating variables such as electric Power supply/control. The results are applied directly to design of wide-pitch-spacing EP and the developed numerical model was found to be a good argreement with the experimental results. The EHD simulation program is necessary to design the high efficiency EP.

  • PDF

Influence of the Distribution of Wind Velocity and Mist Concentration for the Improvement of Efficiency with an Electrostatic Precipitator (전기집진장치의 효율 개선을 위한 풍속 분포 및 입자농도 분포의 영향)

  • 임헌찬;이덕출
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.155-161
    • /
    • 1998
  • Recently, there are widely needs of small scale electrostatic precipitator(ESP) in machine shop and other factories. Since the space of such factories is limited, the improvement of collection efficiency is predominant subject. In this study, we examine the influence of distribution of wind velocity and oil mist concentration inside the ESP in order to improve the performance of the ESP. The distribution of wind velocity and mist concentration is measured respectively in a cross-sectional plane of the ESP. The former is controlled by using a louver which is placed in front of an ionizer and the latter is controlled by lengthening the pipe of entrance of the ESP in order to have plenty of time that mist is dispersed evenly. It is shown that the uniformity of distribution of wind velocity and mist concentration inside the ESP can be getting by adopting a louver with proper shape and lengthening the pipe of entrance and is also contributed to collection efficiency considerably.

  • PDF

A Theoretical Study on the Initial Collection Efficiency of Submicron Particles by a Unipolar Charged Fiber (단일 전하로 하전된 단일 섬유에서의 미세입자의 초기 집진효율에 관한 이론적 연구)

  • 오용학;전기준;정용원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.3
    • /
    • pp.259-268
    • /
    • 2001
  • In this study, we have developed a simulation method to predict the initial collection efficiency of a unipolar charged fiber in the electret filters. The particle sizes considered were in the submicron range and thus Brownian motion of particles was also taken into consideration along with electrostatic forces acting on the particles. The simulation results were compared with other investigators experimental data on single fiber efficiency as well as with the calculated results using the existing correlations on single fiber efficiency. It has been shown that simulation results are in good agreement both with the experimental data with those predicted by the correlations.

  • PDF

A Basic Study on Developing an Electrocharged Scrubber (전기하전식 세정집진장치 개발에 관한 기초 연구)

  • 김종호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.1
    • /
    • pp.33-39
    • /
    • 1999
  • This study has been performed to develop an efficient electrocharged scrubber. To improve collection efficiency of the scrubber, electric-charger was installed at the forefront of the packed crossflow scrubbers, and an experiment of changing discharge electrode shape and fluctuating electric field strength was undertaken. After using a light-oil boiler for generation of particles in the about 80% weight of submicron size particles was exhausted. Collection characteristics of the electrocharged scrubber were similar to those of two-stage electrostatic precipitator. In this study the collection efficiency of submicron size particles has been much improved, compared with the previous ones. In an experiment of changing discharge electrode and electric field strength, a needle-spike shape wire electrode showed a higher collection efficiency than round shape wire. The collection efficiency becomes increased with an increase of electric field strength.

  • PDF

A study on the Electrostatic Precipitator evolution for PM-10 elimination of subway station (지하전철 구간의 미세먼지 제거를 위한 전기집진기 개발에 관한 연구)

  • Rho Sung-Chan;Kim Yoon-Ho;Kim Soo-Hong;Lee soo-won;Yoo kwang-kiun
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1482-1485
    • /
    • 2004
  • Electrostatic Precipitators have been used widely in industry, and play an important role in environmental protection. Electrostatic Precipitators (ESP) can be operated with a high collection efficiency and low pressure drop. Pulse energization is a technique to cope with high resistivity dust, and this results in lower power consumption. In this paper, Pulse energization ESP to use subway station air clean in subway station, design and test a pulse power supply for ESP.

  • PDF