• Title/Summary/Keyword: 전기집진

Search Result 252, Processing Time 0.025 seconds

Performance Improvement of EP Adopting the Micro-Pulse Concept (펄스하전 방식에 의한 전기집진장치 성능 개선)

  • Kim, J.S.;Kim, W.H.;Kang, I.;Rim, G.H.;Kim, J.H.;Cho, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2243-2245
    • /
    • 1997
  • With the increasing demands for clean environment, development of air cleaning systems has been received increasing attention. EP is usually used for air cleaning in the coal power plant. One of the key technology in the EP is high voltage pulse power supply, which affects the performance of the overall system. In this study, high voltage micro pulse power supply for the EP will be developed for a 500MW coal power plant, which is recently developed technology in the advanced nations. The technology developed will contribute in upbringing the export of heavy electric systems and production of high value-added products.

  • PDF

Application and Development of intelligent distributed control system of electric precipitator for fly ash reduction (비회(Fly Ash) 저감용 전기집진기 지능형 분산제어시스템 개발 적용)

  • Lee, Joo-Hyun;Lim, Ick-Hun;Ryu, Ho-Sun;Sin, Man-Soo;Kim, Bong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2600-2602
    • /
    • 2005
  • An electric precipitator in a thermal electric power plant is essential equipment for preventing air environment pollution. However, it is difficult for the existing control systems to make efficient effects on dust collection. This is because AVC and ERC consist of independent, separate systems in the existing systems. To solve this problem, we developed an intelligent distributed control system, which makes optimal control possible through connection operations between the control systems. In this paper, we analyzed system performance and fly ash reduction effects through the developed system structure, development contents and its actual application to power plant.

  • PDF

Study on the Fine Particle Charging Characteristics with the Electrohydrodynamic Atomization (전기 수력학적 방법을 이용한 미세 입자의 하전 특성에 관한연구)

  • 안진홍;김광영;윤진욱;안강호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.289-294
    • /
    • 2001
  • A well defined electro-spraying and electro-static precipitator(ESP) experiment is carried out to investigate the charging characteristics of the submicron particles and the monodisperse particles. The basic idea is that the highly charged electro-sprayed droplets will be produced into the gas when the Coulombic repulsive force on the surface is higher than the surface tension of the spraying liquid. During this process many highly charged smaller droplets or ions, if the droplets are completely dried out, will be produced in the space. These charged species will be attached ion the particles and then eventually charge the particles. These charged particles will be easily collected with ESP. The experimental results show that the atomizer generated particles with geometric mean diameter (GMD) of 62nm are charged more than 90% even at the mean face velocity of 2.5m/s at the charging zone.

  • PDF

Development of A Hi9h Voltage Pulse Generator for EP (140kV, 20mA급 전기집진기용 고압 펄스 발생장치 개발)

  • Kim, W.H.;Kim, J.S.;Kang, I.;Rim, G.H.;Kim, C.U.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2623-2625
    • /
    • 1999
  • With the increasing demands for clean environment, development of air cleaning systems has been received increasing attention. EP is usually used for air cleaning in the coal power plant. One of the key technology in the EP is high voltage pulse power supply, which affects the performance of the overall system. In this study, high voltage micro pulse power supply for the pilot EP is developed. The power supply has a de source and a pulse one. The ratings of the dc and pulse source are 60kV and 70kV respectively.

  • PDF

Development of A Micro Pulse Concept Power Supply for E.P (전기집진기용 마이크로 펄스 전원장치 개발)

  • Nam, Jung-Han;Kim, Jong-Wha;Cho, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1022-1024
    • /
    • 1999
  • With the increasing demands for clean environment, development of air cleaning systems has been received increasing attention. One of the key technologies in the electrostatic precipitator (EP) is high voltage pulsed power supply, which affects the performance of the overall system. In this study, a high voltage microsecond pulse power supply for the EP is developed for 500MW coal power plants. The power supply has a DC source and a pulsed one. The ratings of the DC and the pulse source are 60kV, 800mA and 70kV, 400mA, respectively.

  • PDF

An Experimental Study on the Performance Characteristics of Electrocyclone (전기사이클론 성능특성에 관한 실험적 연구)

  • Hong, Jin-Il;Han, Jung-Kyun;Oh, Jang-Keun;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.552-557
    • /
    • 2005
  • In order to get the high collection efficiency of the electrocyclone. the effect of inlet and electrode shapes must be well grasped. In this study, performance characteristics of electrocyclone with different inlet and electrode shapes were experimentally investigated and compared as a function of particle size. Experimental results indicated that the helical inlet and tooth electrode have effect on significantly increasing collection efficiency.

  • PDF

Development of 140kV, 20mA Rated High Voltage Pulsed Power System for Pilot EP (140kV, 20mA급 Pilot 집진기용 고압 펄스 전원장치 개발)

  • Kim, Won-Ho;Kang, Iou-Ri;Lee, Kwang-Hak;Kim, Jong-Soo;Rim, Geun-Hie;Kim, Chul-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.2
    • /
    • pp.73-78
    • /
    • 2001
  • With the increasing demands for clean environment, development of air cleaning systems has been received increasing attention. One of the key technologies in the electrostatic precipitator(EP) is high voltage pulsed power supply, which affects the performance of the overall system. In this study, a high voltage microsecond pulse power supply for the pilot EP is developed. The power supply has a dc source and a pulsed one. The ratings of the dc and the pulse source are 60kV and 70kV respectively. The width of pulse voltage is 140us and the maximum pulse repetition frequency is 200Hz.

  • PDF

A Study on the Removal of Complex Odor including Acetaldehyde and Ozone Over Manganese-based Catalysts (아세트알데히드와 오존 복합악취 저감을 위한 망간기반 촉매 성능 연구)

  • Seo, inhye;Lee, Minseok;Lee, Sooyoung;Cho, Sungsu;Uhm, Sunghyun
    • Applied Chemistry for Engineering
    • /
    • v.28 no.2
    • /
    • pp.193-197
    • /
    • 2017
  • In this study, we report on the catalyst process installed in conjunction with a wet plasma electrostatic precipitator to remove the oil mist and fine dust emitted from large-size grill restaurants. The multi-stage catalyst module reduced odor through catalytic reaction of acetaldehyde on catalysts even at an ambient temperature with ozone as an oxidant readily produced in a wet plasma electrostatic precipitator. Two types of manganese-based catalysts, $Mn_2O_3$ and $CuMnO_x$ were fabricated by extrusion molding for structured catalysts in practical applications, and the optimum conditions for high removal efficiencies of acetaldehyde and ozone were determined. When two optimized catalysts were applied in a two-stage catalyst module, the removal efficiency of acetaldehyde and ozone were ${\geq}85%$ and 100% respectively at the space velocity of $10,000h^{-1}$ and the reaction temperature of $100^{\circ}C$.

Development of Road Tunnel Ventilation System with Electrostatic Precipitator (도로터널용 전기집진시스템 개발)

  • Kim, Jong-Ryul;Weon, Jong-Oung
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.80-83
    • /
    • 2008
  • As SOC (Social Overhead Capital) has been expanded, the highway road construction has been accelerated and city road system has been more complicated. So, long road tunnels have been increased and traffic flow rate also has been raised. Accordingly, the exhausting gas of vehicle cars seriously deteriorates the tunnel inside air quality and driving view. In order to improve tunnel inside air quality, we may need to introduce a compulsory ventilation system as well as natural ventilation mechanism. The natural ventilation mechanism is enough for short tunnels, meanwhile longer tunnels require a specific compulsory ventilation facility. Many foreign countries already have been devoting on development of effective tunnel ventilation system and especially, some European nations and Japan have already applied their developed tunnel ventilation system for longer road tunnels. More recently, as the quality of life improved, our concerns about safety of driving and better driving environment have been increased. In order to obtain clearer and longer driving view, we are more interested in EP tunnel ventilation system in order to remove floating contaminants and automobile exhaust gas. Evan though it's been a long time since many European countries and Japan applied more economical and environment-friendly tunnel ventilation system with their self-developed Electrostatic Precipitator, we are still dependant on imported system from foreign nations. Therefore, we need to develop our unique technical know-how for optimum design tools through validity investigation and continuous possibility examination, eventually in order to localize the tunnel ventilation system technology. In this project, we will manufacture test-run products to examine the performance of system in order to develop main parts of tunnel ventilation system such as electrostatic precipitator, high voltage power generator, water treatment system, etc.

  • PDF

Optimization of an Ozone-based Advanced Oxidation Process for the Simultaneous Removal of Particulate Matters and Nitrogen Oxides in a Semiconductor Fabrication Process (반도체 제조공정 미세먼지-질소산화물 동시 저감을 위한 오존 고속산화공정 최적화 연구)

  • Uhm, Sunghyun;Lee, Seung Jun;Ko, Eun Ha;Hong, Gi Hoon;Hwang, Sangyeon
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.659-663
    • /
    • 2021
  • 10 m3/min (CMM) multi-pollutants abatement system was successfully developed by effectively integrating ozone oxidation, wet scrubbing, and wet electrostatic precipitation for the simultaneous removal of particulate matters (PMs) and NOx in a semiconductor fabrication process. The sophisticated control and optimization of operating parameters were conducted to maximize the destruction and removal efficiency of NOx. In particular, the stability test of a wet electrostatic precipitator was carried out in parallel for 30 days to validate the reliability of core parts including a power supply. An O3/NO ratio, which is the most important operating parameter, was optimized to be about 1.5 and the optimization of wet scrubbing with a reducing agent made it possible to analyze the contribution of neutralization reaction.