The Evaluation of Thermal Aging Characteristics in Insulating Paper for the Use of the Pole Transformers (가속열화 방법에 의한 주상변압기 절연물의 열열화 특성 평가)

  • Lee, Byung-Sung;Song, Il-Keun;Lee, Jae-Bong;Park, Dong-Bae;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.100-103
    • /
    • 2003
  • The primary insulation system used in an oil-filled transformer is kraft paper, wood, porcelain and oil. Modern transformers use paper that is chemically treated to improve its tensile strength properties and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged to thermal stress. Over the course of the insulation paper and oil's life it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper using the layer insulation. We made two aging cell in which thermal aging tests of insulation papers and mineral oil are conducted. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

  • PDF

Distribution Characteristics of AE Signals in Insulation Deterioration and AE Noise in Cast Resin transformer (절연물의 열화에 의한 AE신호와 변압기 외함의 AE노이즈 분포)

  • Lee, Sang-Woo;Kim, In-Sik;Kim, Lee-Kook;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1865-1867
    • /
    • 2002
  • In this paper, frequency spectra of AE signals detected from respective the insulation deterioration were analysed to under ac high-voltage application using epoxy resin sample and insulation oil. Also, frequency spectra of AE signals generated from the load currents in the actual operating transformer of 500[kVA] under distribution system of 22.9[kVJ] were also analysed to distinguish the AE signals due to void discharges from the magnetic circuit noises in transformer. As the experimental results, we could distinguish the AE signals whether those signals were caused due to the void discharges or due to the magnetic circuit noises by analyzing the frequency spectrum of AE signals.

  • PDF

A Characteristic of Tracking Progress Happened at the End of the VCTFK (VCTFK 끝단에서 발생되는 트래킹의 진전특성)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Ok, Kyung-Gea;Lee, Chun-Ha;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.78-83
    • /
    • 2010
  • This paper describes the characteristic of tracking progress happened at the end of the polyvinyl chloride insulated cabtyre oval cord(VCTFK) that is widely used for distribution cord. Tracking is occurred owing to the drop of electrolyte at the end of the VCTFK. The tracking progress and its characteristic happened at the end of the VCTFK are as follow; Carbonization and electrical erosion are happened at the end of the VCTFK. Electrical erosion is begun at the insulation layer near conductors. After that, it is also happened at the sheath layer. Accumulation of carbonized insulation and sheath materials at the end of the VCTFK is begun after progress of electrical erosion. When the accumulation is progressed arc discharge is appeared and finally it goes to tracking breakdown.

Development of an Inspection Box for a Guard Lamp with an Automatic Switch (자동점멸식 보안등 점검함 개발)

  • Jung, Jong-Wook;Jung, Jin-Soo;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.34-40
    • /
    • 2008
  • In this paper, a device for safety inspection of a guard lamp with an automatic switch which has been recently employed in some local autonomous entities was developed. It is technically enhanced by installing a separate inspection box down below, which allows the inspectors can measure the leakage current, the sound function of the electric leakage breaker(ELB), the insulation resistance and the grounding resistance, on the ground. This inspection box makes the inspectors free from the electric shock by being designed to minimize the potential direct contact with the energized terminals. The deliverables of this paper are expected to contribute to carry out the inspection for the guard lamps safely and effectively.

Charge transport and electroluminescence in insulating polymers (절연물 폴리머의 전하이동과 전계발광)

  • Yun, Ju-Ho;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.351-352
    • /
    • 2007
  • Polymers submitted to thermo/electrical stress suffer from ageing that can drastically affect their functional behaviour. Understanding the physico/chemical processes at play during ageing and defining transport regimes in which these mechanisms start to be critical is therefore a prime goal to prevent degradation and to develop new formulation or new materials with improved properties. It is thought that a way to define these critical regimes is to investigate under which conditions (in terms of stress parameters) light is generated in the material by electroluminescence (EL). This can happen through impact excitation/ionization involving hot carriers or upon bi-polar charge recombination (a definition that excludes light from partial discharges, which would sign an advanced stage in the degradation process). After a brief review of the EL phenomenology under DC, we introduce a numerical model of charge transport postulating a recombination controlled electroluminescence. The model output is critically evaluated with special emphasize on the comparison between simulated and experimental light emission. Finally, we comment some open questions and perspectives.

  • PDF

Superconducting properties through ceramic coating condition on high-Tc superconducting tapes (고온 초전 도체의 산화물 코팅 조건 변화에 따른 초전도 특성의 변화)

  • 이남진;하동우;하홍수;장현만;오상수;손명환;권영길;김상현;류강식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.218-221
    • /
    • 2000
  • Currently, Bi-2223 HTS tape is capable of being fabricated in longer than 100m length by industrial processes. But there are some problems in heat treatment of the degree of longer than 100m tape, which is in term of volume occupied with specimen in furnace. The effects of ceramic coating with variable slurry states were studied in Bi-2223 high-temperature superconductor. The HTS tapes coated with oxide were prepared by using dip-coating method on slurry state. Critical current(I$_{c}$) of tapes coated with ceramic materials were equal with 11.5A at 77K after first heat treatment as different slurries. For final heat treatment, Critical current of HTS tapes coated with zirconia oxide mixed in PMMA and PVA organic solute were 20.8A at 77K. The breakdown voltage of HTS tapes coated with zirconia oxide were 3kV in air and 4~7kV in L$N_2$.>.

  • PDF

A Study on Dynamic Characteristics of EFPCD for Electrical Fire Prevention (전기화재 예방을 위한 EFPCD동작 특성에 관한 연구)

  • 이상호;오홍석
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.8-11
    • /
    • 2002
  • Recently, the spark and the overheat due to in the failure of pressure contacts on connecting points and the momentary short circuit have been the major causes of electrical fire because these may cause the deposition and the graphite of insulating materials in electrical wiring system. Also, because in these cases the current is a surge one, the losses and faults of a communication, a home appliances, a computer and a measuring instrument may occur. Especially, in such cases, we are very difficult to detect the failure of pressure contacts on connecting points and the momentary short circuit. In this paper, we have developed an auxiliary control device, the electrical fire prevention control device(EFPCD), of an earth leakage breaker(ELB). And we can pre-vent the electrical fire caused by the spark and the overheat occurring in the failure of pressure contacts in connecting points and the momentary short circuit with the EFPCD.

Development of Large Propulsion Motor Bearings Considering Slope Conditions (경사조건을 고려한 대용량 추진 전동기용 베어링 개발에 대한 연구)

  • Oh, Seung Tae;Choi, Jin Woo;Kang, Byeng Hi;Kim, Jin;Choi, Seong Pil;Bin, Jae Goo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.2
    • /
    • pp.241-248
    • /
    • 2013
  • In this study, bearings were developed for a high-power propulsion motor operating in inclined operation conditions through a simulation and similitude-experimental methods using commercial rotating machinery dynamics analysis software. The developed journal bearing is electrically insulated and has low thermal conductivity because each part is connected with 2-4 -mm-thick epoxy plates. To realize an appropriate oil thickness, an oil lift system is adopted, and a half separated structure is applied to ensure the feasibility of maintaining very heavy components. This study discusses some of the key design aspects of sleeve bearing design for high-torque and low-speed propulsion motor applications. Furthermore, the conditions of variable slope tests are examined to prevent oil leakage from the bearing lip seal on the test rig.

Quantitative Analysis on Near Band Edge Images in GaAs Wafer (GaAs 웨이퍼의 대역단 영상에 대한 정량적 해석)

  • Kang, Seong-jun;Na, Cheolhun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.5
    • /
    • pp.861-868
    • /
    • 2017
  • Near band infrared imaging technique has adopted for imaging EL2 and shallow level distributions in undoped semi-insulating LEC GaAs. This technique, which relies on the mapping of near bandgap infrared transmission, is both rapid and non-destructive. Until now no quantitative analysis has been reported for near band edge region which gives the reverse contrast on EL2 absorption images. This paper presents the spectral, spatial and temperature dependence of photoquenching forward and inverse mechanism in the band edge domain for cells and walls and for direct and inverted contrast conditions during transitory regimes. The difference in the threshold for the EL2w and EL2b defects could be attributed to the contribution of a different electrical assistance due to a different species of impurities. Quantitative analysis results show an increased density of EL2w and a small reduction of EL2b in the region of the walls where there is a high density of dislocations.

RF Magnetron Spurrering법으로 증착한 IGZO 박막의 특성과 IGZO TFT의 전기적 특성에 미치는 RF Power의 영향

  • Jung, Yeon-Hoo;Kim, Se-Yun;Jo, Kwang-Min;Lee, Joon-Hyung;Kim, Jeong-Joo;Heo, Young-Woo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.340.2-340.2
    • /
    • 2014
  • 최근 비정질 산화물 반도체는 가시광 영역에서의 투명도와 낮은 공정 온도, 그리고 높은 Field-effect mobility로 인해 Thin film transistors의 Active channel layer의 재료로 각광 받고 있다. ZnO, IZO, IGO, ITGO등의 많은 산화물 반도체들이 TFT의 채널층으로의 적용을 위해 활발히 연구되고 있으며, 특히 비정질 IGZO는 비정질임에도 불구하고 Mobility가 $10cm^2/Vs$ 정도로 기존의 a-Si:H 보다 높은 Mobility 특성을 나타내고 있어 대화면 디스플레이와 고속 구동을 위한 LCD에 적용 할 수 있으며 또한 낮은 공정 온도로 인해 플렉서블 디스플레이에 응용될 수 있다는 장점이 있다. 우리는 RF magnetron sputtering법으로 증착한 비정질 IGZO TFT(Thin Film Transistors)의 전기적 특성과 IGZO 박막의 특성에 미치는 RF power의 영향을 연구하였다. 제작한 TFTs의 Active channel layer는 산소분압 1%, Room temperature에서 RF power별(50~150 W)로 Si wafer 기판 위에 30nm로 증착 하였고 100 nm의 $SiO_2$가 절연체로 사용되었다. 또한 박막 특성을 분석하기 위해 같은 Chamber 분위기에서 100 nm로 IGZO 박막을 증착하였다. 비정질 IGZO 박막의 X-ray reflectivity(XRR)을 분석한 결과 RF Power가 50 W에서 150 W로 증가 할수록 박막의 Roughness는 22.7 (${\AA}$)에서 6.5 (${\AA}$)로 감소하고 Density는 5.9 ($g/cm^3$)에서 6.1 ($g/cm^3$)까지 증가하는 경향을 보였다. 또한 제작한 IGZO TFTs는 증착 RF Power가 증가함에 따라 Threshold voltage (VTH)가 0.3~4(V)로 증가하는 경향을 나타내고 Filed-effect mobility도 6.2~19 ($cm^2/Vs$)까지 증가하는 경향을 보인다. 또한 on/off ratio는 모두 > $10^6$의 값을 나타내며 subthreshold slope (SS)는 0.3~0.8 (V/decade)의 값을 나타낸다.

  • PDF