• Title/Summary/Keyword: 전기전도도 센서

Search Result 53, Processing Time 0.029 seconds

A bio-sensor SoC Platform Using Carbon Nanotube Sensor Arrays (CNT 배열을 이용한 bio-sensor SoC 설계)

  • Chung, In-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.12
    • /
    • pp.8-14
    • /
    • 2008
  • A fully CMOS-integrated carbon nanotube (CNT) sensor array is proposed. After the sensor chip is fabricated in commercial CMOS process, the CNTs network is formed on the top of the fabricated sensor chip through the room-temperature post-CMOS processes. When the resistance of the CNT is changed by the chemical reaction, the read-out circuit in the chip measures the charging time of the $R_{CNT}$-Capacitor. finally the information of measured frequency is converted to a digital code. The CMOS sensor chip was fabricated by standard 0.18um technology and the size of the $8{\times}8$ sensor array is $2mm{\times}2mn$. We have carried out an experiment detecting the biochemical material, glutamate, using this sensor chip. From the experiment the CMOS sensor chip shows the feasibility of sensor for the simultaneous detection of the various target materials.

A Study of BioSignal Analysis for Physical Activity of Wu-Shu Training (우슈 수련자의 신체활동에 따른 생체신호 분석에 관한 연구)

  • Kim Chang-Mo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.6
    • /
    • pp.230-237
    • /
    • 2005
  • In this paper, we are suggested a method that's a major topics in sports medicine. It is disease control, control and management of chronic degenerative disease, and promotion of health. We are analyze physical activity to scientific and quantitative a trainee at Wu-Shu gymnasium, for a suggested method. We are measured a quantity of physical activity by SenseWear-PRO2-Armband which develop body-media company. Armband include to skin temperature sensor, near-body temperature sensor, accelerometer, heat flux sensor, galvanic skin response sensor. Acquired data was recorded to storage in Armband. We are analyzed using InnerView Wearer Software in the Stored data to skin temperature, calorie expenditure, quantity of physical activity. The result of this analyzed, we are know that a man of long-term exercise expenditure energy at short time and if liveliness of physical activity was Increase in expenditure energy with increase skin temperature. Also, we are know that the heat flux after increase expenditure energy with increase skin temperature. And, know that GSR was not affected a factors that physical activity, expenditure energy, increase skin temperature, and others.

  • PDF

Thermoelectric properties of $(Bi,;Sb)_2;(Te,;Se)_3$-based thin films and their applicability to temperature sensors ($(Bi,;Sb)_2;(Te,;Se)_3$계 박막의 열전 특성 및 온도 센서로의 응용)

  • 한승욱;김일호;이동희
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.1
    • /
    • pp.69-76
    • /
    • 1997
  • P-type ($Bi_{0.5}Sb_{1.5}Te_3$) and n-type ($Bi_2Te_{2.4} Se_{0.6}$) thermoelectric thin film were deposited on glass and Teflon substrates by the flash evaporation technique. The changes in thermoelectric properties, such as Seebeck coefficient, electrical conductivity, carrier concentration, carrier mobility, thermal conductivity, and figure of merit, were investigated as a function of film thickness and annealing condition. Figures of merit of the thin films annealed at 473 K for 1 hour were improved to be $1.3{\times}10^{-3}K^{-1}$ for p-type and $0.3{\times}10^{-3}K^{-1}$ for n-type, and they were almost independent of film thickness. Temperature sensors were fabricated from the thin films having the above mentioned properties. And thermo-emf, sensitivity, and time constant of the sensors were measured to evaluate their characteristics for temperature sensors. Thin film sensors deposited on Teflon substrates showed better performance than those on glass substrates, and their sensitivity and time constant were 2.91 V/W and 28.2 sec respectively for the sensor of leg width 1 mm$\times$length 16 mm.

  • PDF

During Demonstration Test of the Estuary Bank, Vertical Profiling Measurement in a saline groundwater (하굿둑 실증시험 시 염지하수의 연직 프로파일링 관측)

  • Kim, Byung-Woo;Choi, Doo Houng
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.447-447
    • /
    • 2022
  • 하굿둑 실증시험 및 개방 시 하굿둑으로부터 해안지역 대수층의 지하수 내 염분침투를 예방하고 지속가능한 지하수자원 이용과 관리를 위해서 담수(freshwater)와 염수(saltwater)의 경계면 변동 및 분포를 추적하기 위해 지화학적·물리적 접근 연구는 매우 중요하다. 해안 및 하굿둑 주변지역의 담·염수 경계면 특성에 관한 조사 및 분석은 직·간접적 관측방법으로 이뤄진다. 직접 관측방법에는 심도별 전기전도도(Electrical condutivity, EC) 측정 방법으로 1개 정밀센서(CTD-Diver)를 와이어에 연결하여 수동으로 측정하는 방식과 자동 관측센서(CTD-Diver)를 공내 여러 관심심도에 이격거리에 따른 관측센서를 여러 개 설치하여 특정 관심심도별 연속적인 상태를 파악하는 방법이다. 간접 관측방법에는 관심심도별 또는 특정 심도의 지하수 수질을 채취하여 지화학 분석하는 방법이 있다. 직·간접적 관측방법에는 관심심도별 구간의 이격거리와의 공백과 조사시기에 대수층의 해수침투를 파악할 수 있으나 연속적 관측과 예측은 매우 어렵다. 직접적 관측방법 중 1개 정밀센서와 와이어를 이용한 특정 시·공간에 대한 연직 프로파일링 관측은 가능하나, 연속적 관측과 예측 또한 매우 어렵다. 따라서 본 연구는 물리적 방법을 기반으로, 하굿둑 인근의 담수(freshwater)와 염수(saltwater)와의 경계면 분포특성에 관한 연구는 하굿둑 실증시험 시 지하수 내 염분침투에 따른 지하수 환경 등에 대한 전반적 특성 등을 분석하였다. 하구언 일대의 지하수 내 염분침투 및 지하수 오염관리를 위해 실증실험 등 인위적인 요소와 강우, 태풍, 가뭄 등 자연적인 요소에 의해 여러 형태의 분포특성을 보이는 담수와 염수의 분포 및 혼합대의 특성에 따른 담염수의 경계면 형태별 분석을 하는데 목적을 두었다. 해수침투의 예방과 지하수 오염 방지를 위해 심도별 자동 수질측정 장치를 개발하고, 이를 이용한 염지하수의 프로파일링 감시 시스템을 제안하였다.

  • PDF

Development of an Urea Sensor using Electric Conductivity Method (전기전도도법을 이용한 우레아 농도 센서 개발)

  • Choi, B.C.;Kim, K.Y.;Yang, J.Y.;Kim, H.N.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.55-60
    • /
    • 2011
  • The popularity of diesel engines is derived primarily from their higher thermal efficiency resulting from higher compression ratio. NOx removal from the diesel emissions is very important to meet stringent emission regulations. NOx emission from diesel engines is removed by an urea-SCR or an LNT system. The urea-SCR system needs the urea-solution supply system with concentration and level sensor. This study was carried out to develop a sensor for the measurement of urea-solution concentration by an electric conductivity method. Considering experimental parameters were the material of electrode, two kinds of electric power(AC or DC), the distance between two electrodes, and the length of electrode. It was found that the AC electric power was more useful to measure the urea-solution concentration compared to DC, because it prevented an ionization of the urea-solution. The silver rod coated with Pt is the most useful electrode, tendency of which is similar to Pt rod, and the cost is more economic. We could also find out the optimum distance between two electrodes and the length of electrode was 10mm and 3mm, respectively.

Porous Silicon : Applications of Chemical Sensors (다공질 실리콘 : 화학 센서로써의 응용)

  • Kang, Chul-Goo;Kang, Moon-Sik;Jin, Joon-Hyung;Yoo, Jae-Tack;Hong, Suk-In;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1581-1583
    • /
    • 2002
  • 본 논문은 다공질 실리콘 다이어프램에 대한 화학 센서의 일종인 습도, 에탄올, 메탄올의 감지 특성을 측정하고 전기 전도도의 변화를 고찰하였다. 먼저, TMAH 용액으로 실리콘 다이어프램을 제작한 후, HF와 에탄올의 혼합 용액내에서 일정 전압을 인가하여 다공질 실리콘 다이어프램을 형성하였다. 다공질 실리콘을 면(100)에 수직한 방향으로 $50{\sim}100{\mu}m$ 두께로 균일하게 형성하여 p+-PSi-n+ 구조의 소자를 제작하였다. 다공질 실리콘 다이어프램의 절대습도에 대한 감도는 입력 주파수 5kHz에서 인가 전압이 $2{\sim}6$Vpp에서 $376.3{\sim}784.8{\Omega}$/%RH으로 변하였다. 또, 인가 전압 6Vpp에서 입력 주파수가 $2{\sim}5$kHz으로 변할 때 $393.3{\sim}784.8{\Omega}$/%RH으로 변하였다. 또한, 에탄올에 대한 감도는 $0.068{\mu}A$/%이며, 메탄올은 $0.212{\mu}A$/%으로 다공질 실리콘 다이어프램은 에탄올 보다 메탄올이 더 민감하게 반응하였다. 일반적으로 다공질 실리콘의 전기전도도는 charged surface traps과 screening effect에 의존한다.

  • PDF

Development of On-line Water Quality Monitoring System (온라인 수질 감시 시스템의 개발)

  • Kim, Jae-Chul;Lee, Jae-Yun;Park, Jong-Sik;Kwon, Woo-Hyen;Kim, Sung-Ho;Lee, Chan-Won
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.75-85
    • /
    • 1996
  • Real time water quality monitoring system in a large area has been developed. The system is hierarchically composed of CCMS(Central Control and Monitoring System), data loggers and water pollution measuring instruments, which enable systematic and efficient data collection and management. Also in this work we designed and constructed the instruments for measuring basic elements in water quality such as salinity, electrical conductivity, temperature, dissolved oxygen and the amount of coli in water.

  • PDF

카본나노튜브의 유동장에서의 이동에 관한 Multi-physics 현상 해석

  • 권순근;김수현;유영은;한창수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.143-143
    • /
    • 2004
  • 탄소나노튜브는 고종횡비, 10nm이하의 매우 작은 직경, 높은 전기전도도 및 열전도도, 금속 및 반도체 특성 둥의 우수한 특성 때문에 많이 사용되고 있다. 최근에는 전기적 소자나 화학적, 기계적 센서 그리고 측정용 프로브로 사용될 목적으로 탄소 나노 튜브를 전극들 사이나 끝 단이 날카로운 탐침의 끝에 위치시키는 연구가 진행되고 있다. 탄소나노튜브를 끝 단이 날카로운 탐침의 끝에 위치시켜 CNT tip을 만드는 경우, 지금까지는 수동 조작(manipulation)에 의한 방법과, 화학기상증착법(Chemical Vapor Depsosition: CVD)에 의한 성장방법이 많이 사용되고 있다.(중략)

  • PDF

Implementation of Geographic Information System apply to Integrated Management of Water Wells Sub-Observation Network (지하수 보조 관측망 통합 관리를 지원하기 위한 지리정보 시스템 구현)

  • Kim, Kyung-Jong;Jung, Se-Hoon;Kwon, Young-Wook;Sim, Chun-Bo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.39-42
    • /
    • 2011
  • 본 논문에서는 지하수 관정관리의 효율성을 위해 지리정보와 USN기술 기반의 통합된 모듈을 구축한다. 이 모듈에서는 GPS 위치 값, 환경 센서(수온, 수심, 전기전도도)의 값을 CDMA 통신 모듈을 통해 서버로 전달받아서 저장한다. 관정의 위치를 GIS맵상에서 표현을 하기 위해서 실측 지도와 위성사진 자료를 이용하여 GIS맵을 구축하여 시스템 화면상에 실측지도와 함께 지리정보를 맵핑한다. 통합된 클라이언트 형태로 시스템 서비스를 제공한다.

  • PDF

Development of Cylindrical Capacitive-Conductive Sensor to Evaluate Insulating Degradation for FCEV Stack (차량용 연료전지 스택의 절연열화 진단을 위한 원통형 정전용량-전기전도도 센서개발)

  • Kim, Jae-Hoon;Kim, Ju-Han;Kim, Yoon-Hyung;Cui, Jiang-Yue;Han, Sang-Ok;Yong, Gee-Joong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.317-324
    • /
    • 2010
  • It was used as measuring system to diagnose insulating condition, by which was kept a insulating resistance of inner stack and at the same time was cooled electrochemical heat of reaction of FCEV(fuel cell electric vehicle) stack that used a compressed hydrogen gas reacting with oxygen in accordance with variation on thermal degradation of nonconductive heat transfer fluid. Consequently it was developed a cylindrical multi-terminal capacitive-conductive sensor that could be attached to the internal surface of cooling system pipe to evaluate capacitance and conductivity of heat transfer fluid.