• Title/Summary/Keyword: 전기적 어드미턴스

Search Result 19, Processing Time 0.025 seconds

The Evolution of Electromechanical Admittance from Mode-converted Lamb Waves Reverberating on a Notched Beam (노치가 있는 보에서 잔향하는 모드변환 램파의 전기역학적 어드미턴스 전이)

  • Kim, Eun Jin;Park, Hyun Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.3
    • /
    • pp.270-280
    • /
    • 2016
  • This paper investigates the evolution of EM admittance of piezoelectric transducers mounted on a notched beam from wave propagation perspective. A finite element analysis is adopted to obtain numerical solutions for Lamb waves reverberating on the notched beam. The mode-converted Lamb wave signals due to a notch are extracted by using the polarization characteristics of piezoelectric transducers collocated on the beam. Then, a series of temporal spectrums are computed to demonstrate the evolution of EM admittance through fast Fourier transform of the mode-converted Lamb wave signals which are consecutively truncated in the time domain. When truncation time is relatively small, the corresponding temporal spectrum is governed by the characteristics of the input driving frequency. As truncation time becomes large, however, the modal characteristics of the notched beam play a crucial role in the temporal spectrum within the input driving frequency band. This implies that mode-converted Lamb waves reverberating on the beam contributes to the resonance of the beam. The root mean square values are computed for the temporal spectrums in the vicinity of each resonance frequency. The root mean square values increase monotonically with respect to truncation time for any resonance frequencies. Finally the implications of the numerical observation are discussed in the context of damage detection of a beam.

Frequency Characteristics of the Air Dielectric Standard Capacitors having 4-terminal-Pair connector Type (4-Terminal-Pair 형 공기유전체 전기용량표준기의 주파수 특성)

  • Kim, Han-Jun;Lee, Rae-Duk;Kang, Jeon-Hong;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1214-1217
    • /
    • 2004
  • 현재 전기용량의 국가표준은 1 kHz, 1592 Hz에서만 유지 및 보급이 되고 있다. 그러나 전기용량 및 임피던스를 측정하는 브리지와 LCR meter들은 비교적 넓은 주파수 범위에서 측정이 가능하도록 생산이 되고 있다. 따라서 이러한 기기들의 교정은 실제적으로 사용되고 있는 주파수 전 영역이 아닌 1 kHz 만 되고 있어서 완전한 교정이라고 할 수 없다. 본 논문에서는 이를 해결하기위하여 임피던스 analyzer의 one-port 측정기술을 사용하여 4-terminal-pair(이하 4TP) 전기용량 표준기 각각의 terminal에서 임피던스를 필요 주파수에서 측정하고, 측정된 임피던스 matrix를 이용하여 4TP의 transfer 어드미턴스와 출력임피던스를 계산 하였다.

  • PDF

Muscle Model including Muscle Fatigue Dynamics of Stimulated Skeletal Muscle (전기자극에 의한 골격근의 근육피로를 고려한 근육모델)

  • Lim, Jong-Kwang;Nam, Moon-Hyon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.11
    • /
    • pp.1476-1478
    • /
    • 1999
  • A musculotendon model is proposed to predict muscle force during muscle fatigue due to the continuous functional electrical stimulation(FES). Muscle fatigue dynamics can be modeled as the electrical admittance of muscle fibers and included in activation dynamics based on the{{{{ { Ca}^{2+ } }}}} kinetics. The admittance depends on the fatigue variable that monotonically increase or decrease if electrical pulse exists or not, and on the stimulation parameters and the number of applied pulses. In the response of the change in activation the normalized Hill-type contraction dynamics connected with activation dynamics decline the muscle shortening velocity and thus its force under muscle fatigue. The computer simulation shows that the proposed model can express the muscle fatigue and its recovery without changing any stimulation parameters.

  • PDF

Selection of Capacity of Circuit Breaker by Probabilistic Short-Circuit Current Analysis (확률적 고장전류 해석에 의한 차단기 용량 선정)

  • 문영현;오용택
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.1
    • /
    • pp.10-15
    • /
    • 1990
  • This paper presents an algorithm that can compute equivalent impedance effctively in computing 3-phase short circuit current which would be generated in power systems. Also this paper proposes a method that can decide the capacity of circuit breaker by analysing the fault current distribution probabilistically when the fault point of specificed line varies. The efficiency of the algorithm was verified by applying the proposed method to IEEE-6bus system and IEEE-30bus system, and probabilistic fault analysing method is verified economic in facility investment by deciding the proper capacity of circuit breaker.

  • PDF

Characteristics Variation Analysis by Shape of Piezoelectric Ultrasonic Transducer with Non-Uniform Thickness (두께 불균일 압전 초음파 트랜스듀서의 형태에 따른 특성변화 해석)

  • Kim, Dong-Hyun;Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.271-278
    • /
    • 2008
  • The electro-mechanical characteristics were theoretically analyzed for the wideband ultrasonic transducer made of non-uniform thickness piezoelectric vibrator. This paper proposes a combination of exponential functions which describes the thickness variation along the length of the vibrator to derive the input admittance and power transfer function of the transducer. The bandwidth and the power transfer function of the transducer were investigated while the lateral shape of the vibrator changes. The results showed there is an optimum shape for the wideband characteristics of the transducer, and the bandwidth has increased up to over 100% as the ratio of minimum value of thickness to maximum value decreases. However, the power transfer function had a downward trend as the ratio of thickness decreases. Also we confirmed that even though the value of transfer function increases as the length of the piezoelectric vibrator increases, the shape providing wideband characteristics is very limited. It means that precision processing is required to manufacturing a wideband ultrasonic transducer with high efficiency.

Estimation of Characteristics Change on Transverse Mode PZT Vibrator Under Space Environment (우주환경하에서 횡진동 모드 PZT진동자의 특성변화 예측)

  • Lee, Sang Hoon;Moon, Guee Won;Yoo, Seong Yeon;Kim, Jung Soon;Kim, Moo Joon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.8
    • /
    • pp.514-522
    • /
    • 2012
  • The temperature dependence of the characteristics in a PZT-5 piezoelectric ceramic vibrator with the transverse mode was investigated in the range of $-100^{\circ}C$ to $90^{\circ}C$ using a thermal vacuum chamber to utilize the vibrator in aerospace industries. As the results, at room temperature, the resonant and anti-resonant frequencies had the minimum value, whereas, the dielectric constant increased linearly from about 2500 to 7500 in the given temperature range. The mechanical loss decreased linearly from 0.08 to 0.03. Through the regression analysis, the temperature dependence functions of the characteristics were derived to linear and square regression functions. Applying the functions, the input admittance characteristics of the piezoelectric vibrator were calculated, and the results showed good agreement with measured ones. It can be confirmed that this method is useful to estimate the characteristics change of the piezoelectric vibrator caused by the temperature change under the space environment.

Design and characterization of conductive transparent filter using [TiO2|Ti|Ag|TiO2] multilayer ([TiO2|Ti|Ag|TiO2] 다층구조를 이용한 전도성 투과필터의 설계 및 특성분석)

  • Lee, Seung-Hyu;Lee, Jang-Hoon;Hwangbo, Chang-Kwon
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.4
    • /
    • pp.363-369
    • /
    • 2002
  • We have designed conductive transparent filters using a low-emissivity coating such as [dielectric|Ag|dielectric] for display applications. The design is the repetition of [$TiO_{2}$|Ti|Ag |$TiO_{2}$] to increase the transmittance in the visible and decrease the transmittance in the near IR. The conductive transparent filters are deposited by a radio frequency(RF) magnetron sputtering system. The optical, structural and electrical properties of the filters were investigated and the optical spectra are compared with simulated spectra. The thickness of the deposited Ag films is above 13 ㎚ to increase the conductivity and that of $TiO_{2}$ films is 24 ㎚ to increase the transmittance in the visible range. Ti blockers are employed to prevent the Ag films from being oxidized by an oxygen gas during the reactive sputtering process. Also, it is shown that the thicker Ti film is necessary as the period increases. Finally, a filter with repetition of the basic structure three times shows the better cut-off near infrared(NIR) and the sheet resistance as low as 2Ω/□ which is enough to shield an unnecessary electromagnetic waves for a display panel.

Suggestion of an experimental method for optimization of flange point of a bolt-clamped Langevin-type ultrasonic transducer (볼트 체결형 란주반 초음파 트랜스듀서의 프렌지 포인트 최적화를 위한 실험적 방법 제안)

  • Kim, Jungsoon;Kim, Haeun;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.4
    • /
    • pp.270-277
    • /
    • 2021
  • In the power ultrasound fields, the flange position for fixing the transducer is an important factor influencing on electro-mechanical efficiency of the transducer. We suggested a practical method that can determine the installation position of the flange for different resonance modes of the bolt-clamped type Langevin ultrasonic transducer. A semicircular wedge-shaped jig was manufactured and moved along the lateral surface of the transducer. The vibration characteristics were examined after a constant pressure was applied to the semicircular wedge-shaped jig. By observing the change of the input admittance of the transducer depending on the position of the pressure application, the optimum position for the flange installation could be determined. The resonant modes of the transducer were calculated by a Mason's equivalent circuit, and the particle velocity distribution for each resonance mode was calculated by a transmission line model. Since the optimum positions determined from an experimental result show a good correspondence with the node positions of the vibration modes calculated by the transmission line model, the validity of the suggested method was verified.

Low-cost Impedance Technique for Structural Health Monitoring (임피던스 기반 저비용 구조물 건전성 모니터링 기법)

  • Lee, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.265-271
    • /
    • 2018
  • This paper presents a method for detecting damage to a structure at low cost using its impedance. The impedance technique is a typical method to detect local damage for structural health monitoring. This is a common technique for estimating damage by monitoring the electro-mechanical admittance signal of the structure. To apply this technique, an expensive impedance analyzer is generally used. On the other hand, it is necessary to develop a low-cost variant to effectively disseminate the technique. In this study, a method based on the transfer impedance using a function generator and digital multimeter, which are generally used in the laboratory instead of an impedance analyzer, was developed. That is, this technique estimates the damage by comparing the damage index using the amplitude ratio of the output voltage measured in the healthy and damaged state. A transfer impedance test was carried out on a steel specimen. By comparing the damage index, the presence of damage could be assessed reasonably. This study is a basic investigation of an impedance-based low-cost damage detection method that can be used effectively for structural health monitoring if supplemented with future research to estimate the damage location and severity.