• Title/Summary/Keyword: 전기적 신뢰성 평가

Search Result 284, Processing Time 0.029 seconds

Application of Chemiluminescence Enzyme Immunoassay Method to Collect in vivo Matured Oocyte in Dog Cloning (개 복제 시 체내 성숙 난자 회수를 위한 화학발광효소면역분석기법의 적용)

  • Kim, Min-Jung;Oh, Hyun-Ju;Kim, Geon-A;Jo, Young-Kwang;Choi, Jin;Lee, Byeong-Chun
    • Journal of Veterinary Clinics
    • /
    • v.31 no.4
    • /
    • pp.267-271
    • /
    • 2014
  • Accurate determination of in vivo oocyte maturation is particularly critical for dog cloning compared to other assisted reproductive technologies because oocytes in metaphase II stage have to be recovered in order to undergo somatic cell nuclear transfer right after its recovery. The aim of present study was to evaluate the reliability and to set a reference range of a chemiluminescence enzyme immunoassay (CLEIA) compared to radioimmunoassay (RIA) method to retrieve in vivo matured oocytes. Serum progesterone concentration during proestrus and estrus was analyzed by RIA and CLEIA to determine ovulation day (Day 0). On Day 3, in vivo oocytes were recovered surgically and evaluated microscopically maturation status after staining nucleus with bisbenzimidazole dye. Mean progesterone concentration by CLEIA ($7.64{\pm}0.06ng/ml$) was significantly higher than by RIA ($6.46{\pm}0.04ng/ml$, P < 0.0001). It was not different between CLEIA ($10.01{\pm}0.34ng/ml$) and RIA values ($7.91{\pm}0.14ng/ml$, P < 0.05) on Day 0, but significantly higher CLEIA level on Day -1 and Day 1 ($6.41{\pm}0.15$ and $14.25{\pm}0.44ng/ml$) was assessed compared to RIA ($4.95{\pm}0.10$ and $11.29{\pm}0.34ng/ml$). However, with both methods, progesterone level was significantly increased from Day -1 to Day 2. To determine oocyte maturation with CLEIA method, a wider and higher reference range has to be considered.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

A Study on the Improvement of User Value through the Analysis of the Status of Smart Home Service in Korea Based on the Internet of Things (사물인터넷 기반 국내 스마트 홈서비스 현황 및 사용 후기 분석을 통한 사용자 가치 제고방안에 관한 연구)

  • Yoon, Seong-Jeong;Kim, Min-Yong
    • Management & Information Systems Review
    • /
    • v.36 no.5
    • /
    • pp.45-60
    • /
    • 2017
  • This study aims to elucidate the key improvements through the current state of customer support for smart home services based on the Internet of things and the evaluation of user's usage. Smart home services typically provide a wide range of value in terms of security, safety, manageability (electricity and water use), convenience, and remote management accessibility. In this study, we analyzed the current state of smart home service based on Internet of Samsung, SKT and LG U + companies in Korea. However, since LG U+ is the only company providing user reviews, there is a limit to generalization, but we are trying to figure out whether the customer value is conveyed properly or not, and in which part the customer support is focused to support the service. As a result of analyzing the results of the study, we found that the smart home service is commercialized and marketed in various forms. However, it is questionable whether the technological level and user satisfaction level are sufficiently satisfied. The results of this study are as follows. First, although each company provides usage guidance, they still ask many questions about joining products and using products. Second, there are many defects in the product itself, and it is found that the companies are not satisfied with the overall response. Third, the three companies are focusing on switches, outlets, sensors, and lamps. This is an individual intelligent product rather than an interlocking or linking level, and it can be seen that there are many parts that are not compatible with the concept of the original Internet of things. In conclusion, this study shows that there are still many areas to improve on the level of customer service provision of smart home service, in particular, the ease of use is low and the quality of products is not reliable. We would like to present the improvement of this in detail through this study and reflect the companies that provide it and the service providers.

Optimization of Soldering Process of Sn-3.0Ag-0.5Cu and Sn-1.0Ag-0.7Cu-1.6Bi-0.2In Alloys for Solar Combiner Junction Box Module (태양광 접속함 정션박스 모듈 적용을 위한 Sn-3.0Ag-0.5Cu 및 Sn-1.0Ag-0.7Cu-1.6Bi-0.2In 솔더링의 공정최적화)

  • Lee, Byung-Suk;Oh, Chul-Min;Kwak, Hyun;Kim, Tae-Woo;Yun, Heui-Bog;Yoon, Jeong-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.3
    • /
    • pp.13-19
    • /
    • 2018
  • The soldering property of Pb-containing solder(Sn-Pb) and Pb-free solders(Sn-3.0Ag-0.5Cu and Sn-1.0Ag-0.7Cu-1.6Bi-0.2In) for solar combiner box module was compared. The solar combiner box module was composed of voltage and current detecting modules, diode modules, and other modules. In this study, solder paste printability, printing shape inspection, solder joint property, X-ray inspection, and shear force measurements were conducted. For optimization of Pb-free soldering process, step 1 and 2 were divided. In the step 1 process, the printability of Pb-containing and Pb-free solder alloys were estimated by using printing inspector. Then, the relationship between void percentages and shear force has been estimated. Overall, the property of Pb-containing solder was better than two Pb-free solders. In the step 2 process, the property of reflow soldering for the Pb-free solders was evaluated with different reflow peak temperatures. As the peak temperature of the reflow process gradually increased, the void percentage decreased by 2 to 4%, but the shear force did not significantly depend on the reflow peak temperature by a deviation of about 0.5 kgf. Among different surface finishes on PCB, ENIG surface finish was better than OSP and Pb-free solder surface finishes in terms of shear force. In the thermal shock reliability test of the solar combiner box module with a Pb-free solder and OSP surface finish, the change rate of electrical property of the module was almost unchanged within a 0.3% range and the module had a relatively good electrical property after 500 thermal shock cycles.