• Title/Summary/Keyword: 전기적부식

Search Result 478, Processing Time 0.029 seconds

Analysis of Electrochemical Corrosion Resistance of Inconel 625 Thermal Spray Coated Fin Tube of Economizer (Inconel 625 용사코팅된 절탄기 핀튜브의 전기화학적 내식성 분석)

  • Park, Il-Cho;Han, Min-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.187-192
    • /
    • 2021
  • In this study, Inconel 625 was used as a thermal spray material to prevent dew point corrosion damage to the economizer tube, and sealing treatment was performed after applying the arc thermal spray coating technology. Various electrochemical experiments were conducted in the 0.5 wt% sulfuric acid solution to analyze the corrosion resistance of the thermal spray coating (TSC) layer. After the anodic polarization experiment, the degree of corrosion damage was determined through a scanning electron microscope and EDS component analysis. When measuring the open circuit potential, the effect of the sealing treatment was confirmed through stable potential formation of the TSC+sealing treatment (TSC+Sealing). As a result of the anodic polarization experiment, the passivation region was confirmed in TSC and TSC+Sealing, and corrosion resistance was improved as no corrosion damage was observed. In addition, the corrosion resistance of TSC+Sealing was the best when analyzing the corrosion potential and corrosion current density calculated by Tafel analysis.

The Study on the Corrosion Behavior of STS 304 for Gas Boiler in the Condensed Water (응축수 중에서 가스보일러용 STS 304의 부식거동에 관한 연구)

  • Du Yun Byoung;Lim Uh Joh;Jeong Ki Cheol
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.1 s.26
    • /
    • pp.21-25
    • /
    • 2005
  • This paper was studied on the corrosion behavior of STS 304 for gas boiler in the condensed water, the electrochemical polarization test of STS 304 for gas boiler in the condensed water was carried out. And the corrosion behavior of STS 304 was considered. The main results are as following: 1) As corrosion environment is acidified from neutrality, the polarization resistance of STS 304 decreases and the corrosion potential is less noble. 2) The corrosion reaction mechanism of STS 304 is cathodic control. 3) As corrosion environment is acidified, the passive potential range of STS 304 decreases. Also, the passive current density of STS 304 increases.

  • PDF

Effect of Y on the Corrosion Properties of Mg-Li-AI Alloy (Mg-Li-AI합금의 부식특성에 미치는 Y의 영향)

  • Kim, Sun-Ho;Kim, Gyeong-Hyeon;Bae, Cha-Heon;Kim, In-Bae
    • Korean Journal of Materials Research
    • /
    • v.6 no.11
    • /
    • pp.1074-1081
    • /
    • 1996
  • Mg-8Li-4AI 합금의 부식특성에 미치는 Y의영향을 전기화학적 분극시험 및 침지시험을 통하여 조사하였다. 전기 화학적 분극시험에서는 Y첨가량이 증가함에 따라 활성화 영역이 감소하엿고 부식전위가 증가하였으며, Y이 4.08wt% 첨가된 경우가 Y이 첨가되지 않은 경우에 비해 부식속도가 크게 감소하였다. 침지시험에서도 Y의 첨가량이 증가함에 따라 Y을 첨가하지 않은 시편에 비하여 무게감량 및 부시속도가 감소하였으며, Y이 첨가되지 않은 합금의 부식속도는 침지시간에 따라 급격히 증가하였지만 Y이 첨가되지 않은 합금의 부식속도는 침지시간에 따라 급격히 증가하였지만 Y이 4.8wt% 첨가된 합금은 96시간 이후부터 더 이상 증가하지 않았다. 이러한 결과는 Y 화합물(Mg24Y5)이 $\alpha$/$\beta$계면에서 희생 양극으로 작용하였기 때문이라고 생각된다. 따라서 Y의 첨가는 Mg-Li-AI 합금의 내식성을 향상시키는 역할을 한 것으로 판단된다.

  • PDF

A study on the prevention of the electric corrosion by leakage current using the Life of Sacrificial Anode in electric railway (전기철도 누설전류의 희생양극법을 이용한 전식 방지에 관한 연구)

  • Yeom, Sung-Bae;Park, Joon-Yeal;Lim, Myung-Hwan;Park, Sang-Wook;Kang, A-Ram
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.379-382
    • /
    • 2009
  • Recently, Since the advent of KTX, the Electric Corrosion by leakage current is on the issue. The corrosion of Underground metal establishment near KTX system causing by its high voltage current become very serious problem. So We must figure for this. For the prevention of corrosion, Many methods is on the discussion. In this paper, We studied the Sacrificial Anode in many methods for its high efficiency.

  • PDF

A Study on the Anti-corrosion Properties of Organic and Inorganic Inhibitor by Electrochemical Evaluation Method in Saturated Aqueous Solution of Calcium Hydroxide (포화 수산화칼슘 수용액 내에서의 무기계 및 유기계 방청제의 전기화학적 방식 특성평가)

  • Kim, Soo-Young;Ryu, Hwa-Sung;Kim, Sung-Kil;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.66-74
    • /
    • 2013
  • In this study, corrosion potential ($E_{corr}$), corrosion rate, and polarization resistance were measured aimed at inorganic inhibitors (passive film type) and organic inhibitors (absorption type). The experiment was conducted using potentiostat for the variable molar ratio and chloride ion concentration of the components of inhibitors in an aqueous solution of saturated calcium hydroxide targeting corrosion. As a result, it was possible to ensure an anticorrosive performance of at least a 1.2 molar ratio of inorganic inhibitors. Also, the organic inhibitors ensured the prevention of the anticorrosive performance of at least about a 0.3 molar ratio. It also showed the tendency that between polarization resistance and corrosion rate, Ecorr and corrosion rate is inversely proportional to the linear. Conversely, the tendency between polarization resistance and Ecorr is proportional to the linear. Also, a distinct difference in organic and inorganic inhibitors' relationship to Ecorr, corrosion rate, and polarization resistance was not shown.

The Changes of Mechanical and Electrical Properties in ACSR Overhead Conductor with Aging (경년에 따른 ACSR가공송전선의 기계적 및 전기적특성 변화)

  • Kim, Byung-Geol;Kim, Shang-Shu;Jang, Tae-In;Kang, Ji-Won;Lee, Dong-Il;Min, Byung-Uk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.619-620
    • /
    • 2005
  • 가공송전선의 수명은 가설 후 경과된 기간(약 36년)으로 정하는 것이 일반적이나 가설된 지역의 환경적 요인이나 전선의 재질상의 특성, 전력공급량 등에 의하여 열화상태가 다양하게 진행된다. 따라서 현재와 같이 모든 전선에 대하여 일정기간으로 정해진 교체 시기는 현실적이지 못하다. 실제로 전선의 단선사고는 경년과 같은 전선의 이력보다는 부식 환경에 노출된 전선의 취약성으로 인하여 초래되는 경우가 많다. 정확한 전선의 수명을 진단하기 위해서는 가공송전선이 노출되어 있는 환경 하에서 경년에 따른 기계적, 전기적 특성의 변화를 조사하여 복합적 인자들을 정량적으로 처리하는 것이 필수적이다.

  • PDF

Evaluation of corrosion resistance for various coated steel sheets by different types of corrosion test method (내식성 코팅 강재의 부식시험 종류 별 내식성 비교 평가)

  • Park, Jae-Hyeok;Hwang, Seong-Hwa;Park, Jun-Mu;Eom, Jin-Hwan;Yun, Yong-Seop;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.163-163
    • /
    • 2017
  • 철강재는 대량 생산이 가능하여 경제성이 뛰어나고 기계적 성질도 우수하여 다양한 산업 분야에서 널리 사용되고 있다. 그러나 철강재는 부식 환경에 취약하기 때문에 그 용도에 따라 다양한 내식성을 부여하는 표면처리를 적용하고 있다. 이러한 철강재에 대한 내식성 표면처리로는 용융아연도금(HDG)과 용융알루미늄도금(HDA)이 우수한 내식성과 다양한 특성으로 널리 사용되고 있으며 아연과 알루미늄을 접목시킨 갈바륨(GL)도금 또한 우수한 내식성 코팅으로 알려져 있다. 또한 최근에는 기존 용융아연도금에 알루미늄(Al) 과 마그네슘(Mg)을 첨가한 3원계 도금강판이 개발되어 기존 용융도금강판 대비 고내식 코팅으로 알려져 있으며 그 적용은 점차 확대되고 있는 추세이다. 일반적으로 이와 같은 강판소재의 내식성 평가에 대해서는 실제 사용할 환경에 폭로하여 비교-시험 하는 것이 가장 확실하고 신뢰도가 높은 방법이다. 그러나 이러한 방법은 경우에 따라 수년에서 수십년에 이르는 장시간이 소요된다. 그러므로 이 방법을 대체하기 위한 각종 가속적 부식 시험들이 널리 적용되고 있다. 즉, 그 목적이나 용도에 따라 염수분무(SST), 침지(Immersion) 및 전기화학적 분극(Polarization) 등 실내에서 부식 시험 하는 방법이 사용되고 있다. 한편, 이러한 부식 가속 시험들은 실제 외부에서 폭로 시험한 결과와의 상관성이 불명확한 경우가 많아 종종 해석에 어려움을 갖고 있는 실정이다. 또한 이 시험 방법들은 동일 재료를 시험하더라도 시험방법의 차이에 따라 부식요인이나 해석방법이 다르므로 인해 그 내식성 결과가 다르게 나타날 수 있다. 그 중 시험목적에 따라 전기화학적 분극 또는 임피던스 분광법(EIS)과 건조 및 습윤 등의 부식 환경 인자들을 적용한 복합부식시험(CCT) 방법은 근사한 대안으로 주목받고 있다. 하지만 이들 시험 또한 실제 부식 환경과는 여러 환경 및 요인들이 다르기 때문에 그 시험방법에 따라 목적하는 시험 결과가 상이하게 나타날 수 있어 해석-평가 하기에 종종 곤란을 갖는다. 이에 따라 최근에는 재현성이 우수하고 실제 부식 환경을 유사하게 모사할 수 있는 내식성 시험과 해석-평가에 대한 내용이 주요한 과제로 사료되고 있다. 본 연구에서는 다양한 내식성 코팅 강판소재들에 대하여 염수분무(SST), 복합부식(CCT), 갈바닉 시험, EIS 시험을 통하여 부식시험 종류 및 시험 환경, 코팅 소재 별 부식경향을 비교-분석하고자 하였다. 또한 이들 부식 진행과정에서는 미세구조관찰(SEM), 결정구조 분석(XRD) 및 원소조성 분석(EPMA)을 통해 다양한 조건에 따른 강판소재들의 부식경향을 비교-평가하고, 실제 환경과의 상관성 및 가속관계를 도출하고자 하였다.

  • PDF