• Title/Summary/Keyword: 전기장센서

Search Result 154, Processing Time 0.022 seconds

Miniaturized λ/4 Folded Microstrip Antenna using Parasitic Element for Parking Management System (무급전 소자를 이용한 소형화된 주차장관리시스템용 λ/4 폴디드 마이크로스트립 안테나)

  • Shin, Jae-yoon;Woo, Jong-myung;Park, Chong-hwan;Keum, Jae-min
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.5
    • /
    • pp.144-151
    • /
    • 2017
  • In this paper, the antenna for parking management using wireless communication in outdoor parking environment was proposed. The proposed antenna was miniaturized by using parasitic element to reduce the size of the radiating element of the basic ${\lambda}/2$ microstrip antenna. The dimensions of the proposed antenna are $35mm{\times}35mm{\times}20.1mm$ that is 98.7% smaller than $309.1mm(0.46{\lambda}){\times}296.1mm(0.441{\lambda}){\times}20.1mm(0.029{\lambda})$ of the basic ${\lambda}/2$ microstrip antenna. The electrical characteristics of the antenna are 1.1 dBi at the center frequency of 447 MHz, an omni-directional radiation pattern on the E-plane, and $87.5^{\circ}$ of HPBW on the H-plane. The miniaturized ${\lambda}/4$ folded microstrip antenna using parasitic element has proved to be easy to mount on the wireless repeater, the sensor node installed on the ground, and the strop bar in the outdoor parking environment.

Fiber-optic Goniometer to Measure Knee Joint Angle for the Diagnosis of Gait Disturbance (보행장애 진단을 위한 무릎관절 각도 측정용 광섬유 각도센서)

  • Kim, S.G.;Shin, S.H.;Jeon, D.;Hong, S.H.;Sim, H.I.;Jang, K.W.;Yoo, W.J.;Lee, B.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1009-1013
    • /
    • 2013
  • In this study, we developed a fiber-optic goniometer for the continuous measurement of knee joint angle which provides important medical information on Alzheimer's disease. The fiber-optic goniometer is composed of a light-emitting diode (LED), a plastic optical fiber (POF), and a voltage output photodiode (PD). As a sensing part of the fiber-optic goniometer, a unclad fiber with regular intervals of 1 mm was fabricated to improve efficiency of bending loss according to the angle variation of knee joint. The emitting light with a center wavelength of 470 nm from a LED is guided by a POF to the PD, the transmitted light is then attenuated by the bending loss inside the bent POF. The intensity variation of the light transmitted from the POF gives rise to a change in output voltage in the fiber-optic goniometer. Therefore, we measured the real-time output voltage of the proposed fiber-optic goniometer using the unclad fiber according to the knee joint angle. Through the repeated experiments, the fiber-optic goniometer shows that it has a reversibility and a wide measurable angle range.

Properties of $(Pb,La)TiO_3$ Ferroelectric Thin Films by Sol-Gel Method for the Infrared Sensors (졸-겔법에 의해 제작된 적외선 센서용 $(Pb,La)TiO_3$ 강유전체 박막의 특성)

  • Seo, Gwang-Jong;Jang, Ho-Jeong;Jang, Ji-Geun
    • Korean Journal of Materials Research
    • /
    • v.9 no.5
    • /
    • pp.484-490
    • /
    • 1999
  • $(Pb,La)TiO_3$(PLT) thin films were prepared on Pt/SiO$_2$/Si substrates by the sol-gel method and investigated the crystalline and electrical properties according to La concentration and post-annealing temperatures. The PLT films annealed at above $600^{\circ}C$ were exhibited the typical perovskite structures regardless of La contents. When the $(Pb,La)TiO_3$(PT) films were doped with La concentration up to 10mol%(PLT-10), the degree of z-axis orientation was greatly decreased from 63% to 26%. From AES depth profiles for the PLT-10 samples, no remarkable inter-reaction between PLT film and lower Pt electrode was found. The remanent polarization$(2Pr,Pr_+-Pr_-)$ were increased from $4\muC\textrm{cm}^2 to 16\muC\textrm{cm}^2$ as the annealing temperature increased from $600^{\circ}C to 700^{\circ}C$. This result may be ascribed to the improvement of crystallinity by the high temperature post-annealing. The dielectric constant$({\varepsilon}r)$ and tangent loss(tan$\delta$) of the PLT-10 films annealed at $650^{\circ}C$ were about 193 and 0.02, respectively with the pyroelectric coefficient($\gamma$) of around $4.0nC/\textrm{cm}^2{\cdot}^{\circ}C at 30^{\circ}C$.

  • PDF

Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area - (큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 -)

  • Yoon Yong Cheol;Suh Won Myung;Yu Chan
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.217-225
    • /
    • 2004
  • This study was performed to provide the basic knowledge about the mushroom cultivation facilities. Classified current status of cultivation facilities in Gyeongnam province was investigated by questionnaire. The structure of Pleurotus eryngii cultivation facilities can be classified into the simple and permanent frame type. The simple frame structures were mostly single-span type, on the other hand, the permanent frame structures were more multi-span than simple structures. And the scale of cultivation facilities was very different regardless of structural type. But as a whole, the length, width and ridge height were prevailing approximately 20.0 m, $6.6\~7.0m$ and $4.6\~5.0m$ range, respectively. The floor area was about $132\~160\;m^2$, and floor was built with concrete to protect mushrooms from various harmful infection. The roof slope of the simple and permanent type showed about $41.5^{\circ}\;and\;18.6\~28.6^{\circ}$, respectively. The width and layer number of growing bed for mushroom cultivation were around $1.2\~1.6m$, 4 layers in common, respectively. Most of year round cultivation facilities were equipped with cooler, heater, humidifier, and ventilating fan. Hot water boiler was the most commonly used heating system, the next was electric heater and then steam boiler. The industrial air conditioner has been widely used for cooling. And humidity was controlled mostly by ultra-wave or centrifuging humidifier. But some farmers has been using nozzle system for auxiliary purpose. More then $90\%$ of the mushroom house had the independent environment control system. The inside temperature was usually controlled by sensor, but humidity and $CO_2$ concentration was controlled by timer for each growing stage. The capacity of medium bottle was generally 850 cc and 1100cc, some farms used 800 cc, 950 co and 1,250 cc. Most of mushroom producted has been usually shipped to both circulating company and joint market.