• Title/Summary/Keyword: 전기임피던스

Search Result 1,220, Processing Time 0.036 seconds

Design Technique Using Bypass Capacitor to Improve Antenna Efficiency of Inverted-F Antenna with Band Stop Matching Circuit (Band Stop Matching Circuit이 적용된 Inverted-F Antenna의 Bypass Capacitor를 이용한 안테나 효율 향상 기법)

  • Bae, Jang Hwan;Choi, Woo Cheol;Lim, Seonho;Yoon, Young Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • In this paper, a design technique using a bypass capacitor is proposed to improve the antenna efficiency of an inverted-F antenna (IFA) with a band stop matching circuit (BSMC). The proposed antenna operates in the LTE bands 26 and 5(814~ 894 MHz). The bandwidth of the IFA is expanded from 803~863 MHz to 800~888 MHz using the impedance change caused by the BSMC. To enhance the antenna efficiency in the expanded frequency band, the bypass capacitor is applied to the IFA with the BSMC. The bypass capacitor improves the efficiency of the antenna by reducing the current variation of the IFA with the BSMC. The proposed antenna has a bandwidth of 804~895 MHz and the antenna efficiency increases by more than 10 % in the extended frequency band by using the bypass capacitor.

Nonenzymatic Sensor Based on a Carbon Fiber Electrode Modified with Boron-Doped Diamond for Detection of Glucose (보론 도핑 다이아몬드로 표면처리된 탄소섬유 기반의 글루코스 검출용 비효소적 바이오센서)

  • Song, Min-Jung
    • Korean Chemical Engineering Research
    • /
    • v.57 no.5
    • /
    • pp.606-610
    • /
    • 2019
  • In this study, we demonstrated that the nonenzymatic glucose sensor based on the flexible carbon fiber bundle electrode with BDD nanocomposites (CF-BDD electrode). As a nano seeding method for the deposition of BDD on flexible carbon fiber, electrostatic self-assembly technique was employed. Surface morphology of BDD coated carbon fiber electrode was observed by scanning electron microscopy. And the electrochemical characteristics were investigated by cyclic voltammetry, electrochemical impedance spectroscopy and chronoamperometry. This CF-BDD electrode exhibited a large surface area, a direct electron transfer between the redox species and the electrode surface and a high catalytic activity, resulting in a wider linear range (3.75~50 mM), a faster response time (within 3 s) and a higher sensitivity (388.8 nA/mM) in comparison to a bare CF electrode. As a durable and flexible electrochemical sensing electrode, this brand new CF-BDD scheme has promising advantages on various electrochemical and wearable sensor applications.

Electrochemical Performance of PFO Pitch coated Natural Graphite using Dry Speed Mixer (건식 스피드 믹서를 이용한 PFO 피치 코팅 천연 흑연의 전기화학적 성능)

  • Youn, Jae Woong;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.410-416
    • /
    • 2021
  • To improve the capacity and stability of natural graphite, the electrochemical performances were investigated by using the prepared natural graphite coated with petroleum pitch for anode materials. The pitch coated natural graphite was prepared using a dry speed mixer by adjusting the rotation speed of the mixer, time, composition of graphite and softening point of the pitch. The physical properties of the anode material were analyzed using SEM, TEM, and PSD. The electrochemical performances were investigated by cycle, C-rate, EIS and CV test. When the pitch coated natural graphite was tested in the condition of 9000 RPM, 10 wt%, 2 h, and softening point of 150 ℃, it showed the highest capacity of 324.5 mAh/g at 0.1 C and a capacity retention rate of 98.9% after 50 cycles. In the test for evaluating rate performance, the capacity retention rate (5 C/0.1 C) was 80.3% and was improved by about 1.7 times over the pristine natural graphite.

Analysis of Characteristics and Internal Resistance of Seawater Secondary Battery according to its Usage Environment (해수이차전지의 사용 환경에 따른 특성 및 내부 저항 분석)

  • Seung-pyo Kang;Jang-mok Kim;Hyun-jun Cho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.223-229
    • /
    • 2023
  • Seawater batteries are next-generation secondary batteries that use seawater as a cathode. They utilize marine resources to provide competitive prices, high eco-friendliness, and a structure suitable for marine applications. Based on these advantages, pouch types and prismatic types have been studied and developed assuming natural seawater exposure. However, because of the electrical characteristics of the secondary battery, its capacity and internal resistance vary depending on the use environment. These characteristics are not only utilized for predicting the life of a battery but also have a direct effect on the capacity and power suitable for a specific situation. Therefore, the internal resistance was analyzed in this study by measuring the capacity depending on the seawater battery use environment and the state-of-charge-open-circuit-voltage measurement method.

Comparison of the Estimations of Body Fat by Bioelectrical Impedence Analysis(BIA) and Anthropometric Measurements of Elementary School Students in Daejeon (대전 시내 초등학생의 생체 전기 임피던스치와 신체계측치에 의한 체지방율 비교 연구)

  • Wang, Soo-Gyoung;Lee, Na-Young
    • Korean Journal of Human Ecology
    • /
    • v.16 no.4
    • /
    • pp.849-854
    • /
    • 2007
  • Body fat proportion is a major issue in health. The prevalence of obesity in childhood has been increasing on thesedays. A series of indirect estimates of body fat have been developed. There are hydrodensitometry, BIA and anthropometry equation for body fat. Hydrodensitometry has been regarded as a common criterion method. BIA made it possible to analyze body fat mass more related to hydrodensitometry than anthropometry. The purpose of this unvestigation were to compare body fat and other body composition between boys & girls and to know which anthropometry equation for body fat was most closely associated with BIA in boys & girls respectively. The subjects were 148 4th grade elementary school students(male:70, female:78). They underwent BIA(InBody 3.0, Biospace Korea)to determine body fat and other body composition. Anthropometric measurements were taken of height, weight, skinfolds and circumferences. The results obtained are summarized as follow: 1) Weight, BMI and Rohrer index were $39.9{\pm}7.2kg$, $20.5{\pm}8.0$, $138.2{\pm}17.0$ for boys and $35.9{\pm}6.7kg$, $18.2{\pm}2.6$, $96.6{\pm}13.6$ for girls. 2) Total body fat and percent body fat determined by BIA were $10.3{\pm}4.3kg$, $25.4{\pm}6.6%$ for the boys group and $9.3{\pm}3.8kg$, $25.1{\pm}6.0%$ for girls. 3) Mean triceps skinfold thickness was $20.5{\pm}6.1mm$ in boys, $17.0{\pm}5.1mm$ in girls and mean WHR was $0.88{\pm}0.4$ in bodys, $0.82{\pm}0.4$ in female and the values were significantly different by sex. 4) Correlational nanlyses showed that estimation of body fat by BIA measurement seemed to be closely associated with Rohere index(boys r=0.854, girls r=0.909). Kim's equation was highly correlated with the body fat in girls(r=0.910) but less correlated in boys(r=0.710). We need to develop specific anthropometric equations based on age and sex to determine body fat for children.

A study on characteristics of High Efficiency and Wideband Microstrip Band Pass Filter for Wireless Data Communication (무선데이터 통신을 위한 고효율 광대역 마이크로스트립 대역통과 필터 특성에 관한 연구)

  • Lee, Young-Hun;Song, Sung-Hae;Park, Won-Woo;Lee, Sang-Jae
    • Journal of IKEEE
    • /
    • v.12 no.4
    • /
    • pp.225-233
    • /
    • 2008
  • This paper presents a compact, low insertion loss, sharp rejection and wide band microstrip band pass filter that is composed rectangular loop resonator and step-impedance-open-stub(SIOS) for wireless data communication. The SIOS can be reduce length about 30% more than general 0.25${\lambda}$ stub. And stubs can have the advantage of tuning impedance magnitude. In order to demonstrate agrement of this paper prove, the optimized wide band pass filters are realized and experimented. A transmission line model used to calculate the frequency response of the new filters shows good agreement with measurements. The filter with perturbation stubs has four poles at rejection band, the poles are excited 3.610GHz, 4.265GHz at low frequency band, 8.494GHz, 9.056GHz at high frequency band. And the filter has 3dB fractional bandwidth of 57%(3.695GHz), an insertion loss of better than 0.37dB from 4.549GHz to 8.244GHz, and two rejection of greater than 30dB within 237MHz(4.312GHz${\sim}$ 4.549GHz) at low frequency band, 234MHz(8.244GHz-8.491GHz) at high frequency band.

  • PDF

A Study on the Characteristics Analysis of Hybrid Choke Coil with Reduced Parasitic Capacitance suitable for LED-TV SMPS (LED-TV용(用) 전원장치에 적합한 기생 커패시턴스 저감형 Hybrid 초크 코일의 특성 해석에 관한 연구)

  • Lee, Jong-Hyeon;Kim, Gu-Yong;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.22 no.1
    • /
    • pp.185-188
    • /
    • 2018
  • This paper describes the parasitic capacitance modeling according to the coil structure, section bobbin and winding method for hybrid choke coil with reduced parasitic capacitance capable of the EMI attenuation of broad bands from lower frequency to higher frequency applied in the EMI attenuation filter of LED-TV SMPS. Especially, the hybrid choke coil with reduced parasitic capacitance($C_p$) proposed in this paper can reduces the parasitic capacitance($C_p$) by adopting the winding methods of rectangular copper wire, compared to the conventional common mode choke coil with the winding method of automatic type. The first resonant frequency of the proposed hybrid choke coil has a tendency to increase as the parasitic capacitance is smaller and its impedance characteristics, especially in the high frequency bands, improves as the first resonant frequency increases. In the future, the proposed hybrid choke coil with reduced parasitic capacitance shows it can be actually utilized in not only LED-TV SMPS but also various applications such as LED Lighting, Note-PC Adapter, and so forth.

Characteristics of MCMB Anode with VGCF As a Conducting Agent for LPB (LPB용 MCMB 부극 도전재로 VGCF를 첨가한 부극의 특성 연구)

  • Jin Bong-Soo;Doh Chil-Hoon;Moon Seong-In;Yun Mun-Soo;Jeong Jae-Kook;Nam Hyo-Duk;Park Hei-Gu
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.3
    • /
    • pp.143-147
    • /
    • 2004
  • An investigation upon the characterization of MCMB anodes with different vapor grown carbon fiber (VGCF) content for application in lithium polymer battery(LPB) was carried out. When VGCF material was used as conducting agent with MCMB active material, the impedance and the initial coulombic efficiency of test cells were found to decrease with the increasing amount of VGCF. On the other hand, as a function of added VGCF the discharge capacity and the utilization linearly with increased. Impedance of test cell with MCMB anode containing $6wt\%$ VGCF exhibited the lowest value whereas the impedance of $8wt\%$ VUF contained anode was similar to that of MCMB anode without VGCF. Interestingly, $6wt\%$ VUF contained anode showed the best battery characteristics. Internal resistance and rate capacity of the cell were. respectively, $0.918{\Omega}\;at\;25C\;and\;93\%$ at 2C. Generally, rate capability and the cycleability of MCMB based test cells with $4\~6wt\%$ VGCF content exhibited better results than the other cells. In the case of $6wt\%$ VGCF containing anode, the discharge capacity of the cell faded slowly with an ultimate charge-discharge cycling capacity of 178mAh/g at the 100th cycle. Thereafter, the discharge capacity faded negligibly and the utilization of the cell at the 100th cycle was more than $90\%$. The effect of addition of VGCF is discussed in detail.

Broadband Transmission Noise Reduction Performance of Smart Panels Featuring Piezoelectric Shunt Damping and Passive Characteristics (압전감쇠와 수동적 특성을 갖는 압전지능패널의 광대역 전달 소음저감성능)

  • 이중근;김재환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.150-159
    • /
    • 2002
  • The possibility of a broadband noise reduction of piezoelectric smart panels is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing material is bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to tune the piezoelectric shunt circuit, the measured electrical impedance model is adopted. Resonant shunt circuit composed of register and inductor in stories is considered and the circuit parameters are determined based on maximizing the dissipated energy through the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a square crosses sectional tunnel and a loud speaker is mounted at one side of the tunnel as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across the panels is measured. Noise reduction performance of a double smart panel possessing absorbing material and air gap shows a good result at mid frequency region except the first resonance frequency. By enabling the piezoelectric shunt damping, noise reduction is achieved at the resonance frequency as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.

Evaluation of Corrosion Effects on Permanent Ground Anchors (영구 지반앵커에 대한 부식의 영향 평가)

  • Park, Hee-Mun;Park, Seong-Wan
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.2
    • /
    • pp.27-36
    • /
    • 2004
  • The corrosion rate measurement procedure for the permanent ground anchors using polarization resistance measurements and electrochemical impedance spectroscopy is presented in this paper. The polarization resistance measurements were used to determine the correlation between corrosion rate in the steel and soil characteristics. The electrochemical impedance spectroscopy was used to predict the time dependent corrosion reaction and evaluate the different type of coating systems and the effect of cement grouting on the corrosion attack under various conditions. The results indicate that a low pH soil is a good indicator of a corrosive soil. The low pH soil condition (<5) in both clay and sand has a significant effect on the corrosion reaction of steel members in permanent found anchors. In the case of neutral and alkaline conditions beyond pH 6 in clay and sand, no consistent acceleration of corrosion was measured and the corrosion rate was constant regardless of variations of soil pH levels. Laboratory test data for porcelain clay indicate that the change of soil pH level has a small influence on the corrosion reaction in the steel member. The use of cement footing in the bonded length is sufficient to decrease the corrosion rate to a level close to 0.003∼0.01mm/y at the end of the given period. With epoxy and fusion bonded epoxy coating, the steel specimens remained unaffected and retained the original condition. It is suggested that epoxy and fusion bonded epoxy coating can provide effective protection against corrosion for a long time even in aggressive environment.