• Title/Summary/Keyword: 전기임피던스

Search Result 1,220, Processing Time 0.034 seconds

Analysis on the Fuel Cell Performance by the Impedance Method (임피던스법을 적용한 연료전지의 성능평가)

  • Kim, Gwi-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.918-923
    • /
    • 2007
  • Fuel cell is a modular, high efficient and environmentally energy conversion device, it has become a promising option to replace the conventional fossil fuel based electric power plants. The high temperature fuel cell has conspicuous feature and high potential in being used as an energy converter of various fuel to electricity and heat. Corrosions in molten electrolytes and the electric conductivity across the oxide scale have crucial characteristics. When molten salts are involved, high temperature corrosions become severe. In this sense, corrosions of alloys with molten carbonates have the most severe material problems. Systematic investigation on corrosion behavior of Fe/21Cr/Ti or Al alloy has been done in (62+38)mol% (Li+K)$CO_3$ melt at $650^{\circ}C$ using the electrochemical impedance spectroscopy method. It was found that the corrosion current of these Fe-based alloys decreased with increasing Al or Ti. And Al addition improved the corrosion resistance of this type of specimen and more improvement of corrosion resistance was observed at the specimen added with Al.

Optimal switching method of SI-Thyristor using internal impedance evaluation (SI-Thyristor의 내부 임피던스 계산을 통한 최적 스위칭 제어)

  • Ju, Heung-Jin;Kim, Bong-Seok;Hwang, Hwui-Dong;Park, Jeong-Ho;Ko, Kwang-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.122-122
    • /
    • 2010
  • A Static Induction Thyristor (SI-Thyristor) has a great potential as power semiconductor switch for pulsed power or high voltage applications with fast turn-on switching time and high switching stress endurance (di/dt, dV/dt). However, due to direct commutation between gate driver and SI-Thyristor, it is difficult to design optimal gate driver at the aspect of impedance matching for fast gate current driving into internal SI-Thyristor. Thus, to penetrate fast positive gate current into steady off state of the SI-Thyristor, it is proposed and proceeded the internal impedance calculation of the SI-Thyristor at steady off state with the gate driver while switching conditions that are indicated applied gate voltage, $V_{GK}$ and applied high voltage across anode and cathode, $V_{AK}$.

  • PDF

A Study On The Characteristics Of The Medium Voltage Power Distribution Line Channel By Wideband Channel Impulse Response Measurement Using PN Sequence (PN 시퀀스 방식의 광대역 임펄스 응답 측정을 통한 고압 배전선로 채널 특성 연구)

  • Oh, Hui-Myoung;Choi, Sung-Soo;Lee, Jae-Jo;Kim, Kwan-Ho;Whang, Keum-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2646-2648
    • /
    • 2004
  • 전력선 통신(Power-Line Communi-cation)에 있어서 전력선은 유선 매체임에도 불구하고 수많은 분기 및 부하접속, 그리고 상호간의 임피던스 부정합에 의해 무선 통신 채널 환경과 같은 다중 경로 페이딩 특성을 갖게 된다. 따라서 채널의 다중경로 해석이 상당히 중요하며, 실제 전력선 통신 채널 연구 분야에서 신호 송수신단 사이의 임펄스 응답 측정을 바탕으로 다중경로를 분석하는 방안이 적용되고 있다. PN 시퀀스를 이용한 광대역 임펄스 응답 측정 방식은 무선 채널 환경에 대해 개발되었으나, 현재는 무선 채널은 물론 전력선 채널과 같은 유선 채널에서도 적용되고 있다. 게다가 고압 배전선로와 같이 다중 경로를 포함하는 장거리 통신채널은 PN 시퀀스 방식이 여러 가지 면에서 효율적이다[1]. 본 논문에서는 PN 시퀀스 방식의 광대역 임펄스응답 측정 방법을 통해 고압 배전선로 채널의 다중경로 특성을 측정, 검토하고 이를 제시하였다.

  • PDF

Fabrication and Measurement of a Compact Half-bowtie-shaped Meander Microstrip Patch Antenna for the 5-GHz Band (5-GHz 대역용 1/2 보우타이형 미앤더 마이크로스트립패치 안테나의 설계 및 제작)

  • An, Gyoo-Chul;Kim, Heung-Su;Lee, Sang-Mok;Yun, Chung-Han
    • Journal of IKEEE
    • /
    • v.10 no.1 s.18
    • /
    • pp.1-9
    • /
    • 2006
  • This paper presents the characteristics of a half-bowtie-shaped meander-type antenna for the 5-GHz band. Its design is based on a modified meander line width and bowtie shape with coaxial feeding. Its maximum measured impedance bandwidth (-10 dB below) is approximately 1.055 GHz (5.01-6.065 GHz) or 19.05%. Radiation patterns at different frequencies are presented. The measured gain was 2.26-8.86 dBi.

  • PDF

Design of Partial Discharge Sensor using Transmission Line Theory in Rotating Machine (전송선로 이론을 이용한 회전기내 부분방전 검출 센서 해석 및 설계)

  • Heo, Chang-Geun;Kang, Dong-Sik;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.49-51
    • /
    • 2004
  • 고전압 기기의 절연물 내부에서 부분방전 현상이 발생되면 절연파괴로 진전된다. 회전기기가 운전중인 상태에서 on-line 부분방전시험은 고정자 권선의 절연상태를 검사, 평가 할 수 있는 중요한 수단으로서 이러한 부분방전시험을 통하여 회전기기 시스템의 사고예방을 위한 진단을 할 수 있다. 부분방전 펄스는 10MHz $\sim$ 1GHz의 대역폭을 갖는 것으로 알려져 있으며, 이러한 고주파 대역의 전자파 에너지의 효과적인 검출을 위한 센서 중 하나로 웨이브가이드 구조의 고주파 검출센서가 존재한다. 기존의 전자기적 에너지를 검출하는 SSC (Stator Slot Coupler)센서를 한쪽 포트를 가지는 마이크로스트립센서 형태로 사용할 경우 접지면이 도체전체로 씌워져 있고 임피던스 정합을 위한 50옴의 칩저항이 신호라인과 접지사이 루프를 형성하여 기기 운전시 기기의 성능에 영향을 미칠 수 있는 단점을 가지고 있다. 이 단점을 보완하기 위해서 본 논문에서는 회전기내 부분방전 펄스의 전자기적 에너지를 검출할 수 있는 2선 평행 전송선로 라인을 응용한 부분방전 검출 센서를 제안하였고 시뮬레이션을 통해 성능을 입증하였다. 제안된 센서의 성능을 입증하기 위하여 2선 평행 전송선로 타입의 센서와 기존의 SSC (Stator Slot Coupler) 센서를 약간 변형시킨 마이크로 스트립 센서를 고정자 슬롯의 Wedge 부착한 후 두 센서 비교 분석하였다. 결과적으로 제안된 센서는 기존 SSC 타입의 마이크로스트립 센서에 비하여 더 간단한 형상을 가지며 운전 중 기기의 성능에 영향을 덜 미치는 효과를 얻을 수 있었다.

  • PDF

Zero Sequence Impedance of Yg-Yg Three Phase Core Type Transformer (Yg-Yg 3상 내철형 변압기의 영상분 임피던스 분석)

  • Jo, Hyunsik;Cho, Sungwoo;Shin, Changhoon;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.940-945
    • /
    • 2016
  • In this paper, zero sequence equivalent circuit of Yg-Yg three phase core-type transformer is analyzed. Many problems by iron core structure of the three phase transformer due to asymmetric three phase lines, which includes line disconnection, ground fault, COS OFF, and unbalanced load are reported in the distribution system. To verify a feasibility of zero sequence impedance of Yg-Yg type three phase transformer, fault current generation in the three phase core and shell-type Yg-Yg transformer is compared by PSCAD/EMTDC when single line ground fault is occurred. As a result, shell-type transformer does not affect the flow of fault current, but core-type transformer generate an adverse effect by the zero sequence impedance. The adverse effect is explained by the zero sequence equivalent circuit of core-type transformer and Yg-Yg type three phase core-type transformer supplies a zero sequence fault current to the distribution system.

A Fault Location Algorithm Using Adaptively Estimated Local Source Impedance for a Double-Circuit Transmission Line System (자기단 전원 임피던스 추정 기법을 사용한 병행 2회선 송전선로 고장점 표정 알고리즘)

  • Park, Gun-Ho;Kang, Sang-Hee;Kim, Sok-Il;Shin, Jonathan H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.373-379
    • /
    • 2012
  • This paper presents a fault location algorithm based on the adaptively estimated value of the local sequence source impedance for faults on a parallel transmission line. This algorithm uses only the local voltage and current signals of a faulted circuit. The remote current signals and the zero-sequence current of the healthy adjacent circuit are calculated by using the current distribution factors together with the local terminal currents of the faulted circuit. The current distribution factors consist of local equivalent source impedance and the others such as fault distance, line impedance and remote equivalent source impedance. It means that the values of the current distribution factors can change according to the operation condition of a power system. Consequently, the accuracy of the fault location algorithm is affected by the two values of equivalent source impedances, one is local source impedance and the other is remote source impedance. Nevertheless, only the local equivalent impedance can be estimated in this paper. A series of test results using EMTP simulation data show the effectiveness of the proposed algorithm. The proposed algorithm is valid for a double-circuit transmission line system where the equivalent source impedance changes continuously.

PCB Embedded Triplexer and Dual band/Tri-mode RF Module for US CDMA Handset Applications (북미향 CDMA단말기용 PCB 임베디드된 트리플렉서와 듀얼 밴드/트라이모드 RF 모듈)

  • Lim, Sung-P.;Cheon, Seong-J.;Park, Jae-Y.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1384-1385
    • /
    • 2008
  • 본 논문에서는 내장된 수동형 트리플렉서와 듀얼 밴드/트라이모드 RF 모듈을 PCB에 내장시켜서 북미향 CDMA용 부품으로 제작하였다. 수동형 트리플렉서는 모든 수동 소자들을 다층 PCB 기판 안에 내장시키고 그 위에 GPS용 SAW 대역통과필터를 이용하여 설계 및 제작하였다. 8개의 인덕터와 커패시터로 이루어진 수동 회로는 다이플렉서와 병렬 공진기, 임피던스 매칭 회로로 구성되어 있다. CDMA용 듀얼밴드/트라이모드 RF 모듈은 트리플렉서와 CDMA, PCS용 듀플렉서를 테스트 보드 위에 조합하여 제작하였다. 측정된 주파수 특성들은 시뮬레이션 값과 비교적 일치하였다. 트리플렉서와 듀얼 밴드/트라이모드 RF 모듈은 각기 $3{\times}4mm^2$${7\times}7mm^2$의 작은 크기였다. 설계 및 제작된 소자들은 고성능과 경박단소화, 저가화 등의 이점이 있기 때문에, 북미향 CDMA용 단말기의 응용부품에 적용될 수 있을 것으로 예상된다.

  • PDF

Analysis of the Grounding Impedance of a Ground Rod Considering the Frequency-Dependent Resistivity and Relative Permittivity of Soil (토양의 저항률 및 비유전율의 주파수의존성을 고려한 접지봉의 접지임피던스의 해석)

  • Ahn, Chang-Hwan;Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.54-60
    • /
    • 2012
  • When the transient current with high frequency components such as lightning surges are injected the grounding electrodes, the performance of grounding electrodes should be evaluated as grounding impedance. It is restricted to analyze the grounding impedance by measurement approach since the grounding impedance is very different with the shape and size of grounding electrodes, resistivity and relative permittivity of soil and the frequency component of the injected current. So a variety of simulation approaches have been developed. Typically, the soil resistivity measured with low frequency and relative permittivity between 1 and 80 are used for simulation of the grounding impedance. However, the resistivity and relative permittivity of soil are changed with frequency of injected current. In this paper, the frequency-dependent resistivity and relative permittivity of soil are measured and these parameters are reflected in the simulation of the grounding impedance of a ground rod. The simulated results are compared with the measured results. As a result, the simulated results with frequency-dependent soil parameters show capacitive aspect like measured results in the frequency of lower than 100[kHz] and they are more consistent with the measured results in wide frequency range.

Fabrication and Characteristics of a Combination Surge Generator for Testing Shipboard Electrical Systems (선박전기설비 시험용 조합형 써 - 지발생장치의 제작과 특성)

  • 길경석;김윤식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.387-392
    • /
    • 1997
  • This paper describes a combination surge generator for carrying out performance tests on the surge protection circuits of shipboard electrical systems. Pspice simulations were performed to decide the values of the parts required and to analyze the characteristics of the generator circuitry. The surge generator fabricated can produce four of the most common surge test waveforms : the O.5i/S/100kHz Ringwave, the 1.2/50$\mu$S voltage, the 8/20$\mu$S current, and the lO/lOOOi/S voltage wave¬forms specified in ANSI Std. C62. Source impedances of the surge generator are 12$\Omega$ in the O.5$\mu$S/100kHz mode, O.5$\Omega$ in the 1.2/50$\mu$S and 8/20$\mu$S mode, and 40$\Omega$in the l0/1000$\mu$S mode, and are determined by the ratio of the maxi¬mum open - circuit voltage to the maximum short - circuit current. Experimental results show that the surge generator provides most of the outputs required for the testing of the surge protection circuits on shipboard electrical systems.

  • PDF