• Title/Summary/Keyword: 전기임피던스

Search Result 1,220, Processing Time 0.035 seconds

Fabrication and Electrical Properties of Piezoceramics PZT-Polymer 1-3-0 Type Composite (압전세라믹 PZT-고분자 1-3-0형 복합압전체의 제조 및 전기적 특성)

  • Shon, Mu-Hun;Choi, Hun-Il;Sa, Gong-Geon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.4
    • /
    • pp.241-246
    • /
    • 1999
  • In this study, the piezoelectric ceramics PZT powders were synthesized by Wet-Dry combination method. And the flexible 1-3-0 type composites were favricated with piezoceramic PZT and Eccogel polymer matrix embedded 3rd phase. Dielectric constant of 1-3-0 type composites was lower than that of single phase PZT ceramics. Thickness mode coupling factor $k_t$ which was comparable with single phase PZT ceramics, and Mechanical Quality factor $Q_m$ were about 0.65 and 6 respectively. These composites are considered as a good candidates for broad-band type transducer applications. The acoustic impedance for 1-3-0 type composites was lower than that of single phase PZT ceramics. Therefore, these composites would be better used for hydrophone applications.

  • PDF

Electrical and Piezoelectric Characteristics of Piezoelectric transformer (압전변압기의 압전 및 전기적 특성)

  • Kim, Cheol-Su;Bae, Suk-Hye;Park, Jung-Ho;Hur, Chang-Hoi;Lee, Sang-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.482-484
    • /
    • 2000
  • 압전 세라믹은 공정 조건에 따라 압전 및 전기적 특성이 큰 영향을 받는다. 최적의 조건을 갖는 압전변압기를 제조하기 위해서는 이런 공정의 변수들의 변화를 관찰할 필요성이 있다. 본 논문에서는 이런 압전 특성을 관찰하고자, 하소의 온도를 $850^{\circ}C$에서 $900^{\circ}C$도까지 시간변화에 따라 phase 변화를 XRD로 관찰하고 burn out의 온도에 따른 기공변화 및 소결의 온도변화에 따른 임피던스 어낼라이저로 주파수 특성을 관찰하였다. 이렇게 조사해본 결과 하소를 $900^{\circ}C$에서 3시간 burn out을 $500^{\circ}C$에서 2시간, 소결을 $1250^{\circ}C$에서 2 시간 한 경우가 $Q_m>1000$, $k_p>0.40$ 값을 얻을 수 있었다.

  • PDF

Measurement errors of the EIT systems using a phantom and conductive yarns (전기임피던스 단층촬영법을 이용한 외란위치 계측오차)

  • Park, Ji Su;Koo, Sang-Mo;Kim, Choong Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1430-1435
    • /
    • 2016
  • Electrical impedance tomography (EIT) has been applied to measure the location of external disturbance using a phantom and conductive yarns. According to the test results, the addition of carbon nanotube particles into the phantom does not show remarkable improvement in location errors. On the other hand combined fabric, conductive yarns with fabric, and non-woven fabric, were added to evaluate its performance as a fabric sensor. The combined fabric resulted in a decrease of 21.5% in the circumferential location error and a decrease of 50% in the radial location error, compared to those of the yarns. Additionally, it was revealed that the measurement error is almost linearly proportional to the conductivity of the phantom liquid and resistance of the conductive yarns. The combined fabric can be a promising material for fabric sensors in sports utilities and medical devices.

A Study on Irradiation Effect by $Co^{60}$ of the R-C Series-Parallel Circuits (방사선조사에 의한 R-C 직.병렬회로에서의 손상효과에 관한 연구)

  • 서국철;조성욱
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.1 no.2
    • /
    • pp.57-61
    • /
    • 1987
  • The characteristis of all the instruments and materials used in atomic industry are changed due to irradiation damages by the effects of radiation activities. In this study when R-C series-parallel circuits are irradiated by $\gamma$-ray, variations in its electrical properties have been investigated. The following results are obtained. 1) In the R-C series circuit, the impedance variation ratio is increased as the irradiation quantity is increased up to $10^6[r]$, and above $10^6[r]$, the impedance variation ratio reached at the saturated condition. In the saturated condition, the increasing value was about 1.25 (%). 2) In the R-C series circuit, the power factor variation ratio is decreased as the irradiation quantity is in creased up to $10^6[r]$, and above $10^6[r]$, the power factor variation ratio reached at the saturated condition. In the saturated condition, the decreasing value was about 0.5(%). 3) In the R-C parallel circuit, the impedance variation ratio is increased as the irradiation quentity is increased up to $10^6[r]$, and above $10^6[r]$, the impedance variation reached at the saturated condition. In the saturated condition, the increasing value was about 0.5.(%). 4) In the R-C parallel circuit, the power factor variation ratio is decreased as the irradiation quantity is increased up to $10^6$[r], and above $10^6$[r], the power factor variation ratio reached at the saturated condition. In the saturated condition, the decreasing value was about 1.3(%).

  • PDF

[ $SiO_2$ ] Effect on the Electrochemical Properties of Polymeric Gel Electrolytes Reinforced with Glass Fiber Cloth ($SiO_2$가 유리섬유로 보강된 고분자 겔 전해질의 전기 화학적 특성에 미치는 영향)

  • Park Ho Cheol;Kim Sang Heon;Chun Jong Han;Kim Dong Won;Ko Jang Myoun
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.1
    • /
    • pp.6-9
    • /
    • 2001
  • [ $SiO_2$ ] effect on the electrochemical properties of polymeric gel electrolytes(PGEs) reinforced with glass fiber cloth(GFC) was investigated . PGEs were composed of polyacrylronitrile(PAN), poly(vinylidenefluoride-co-hexafluoropropylene) (P(VdF-co-HFP)), $LiClO_4$ and three kind of plasticizer(ethylene carbonate, dietyl carbonate, propylene carbonate). $SiO_2$ was added to PGEs in the weight fraction of 10, 20, $30\%$ respectively. PGEs containing $SiO_2$ showed conductivity of over $10^{-3}S/cm\;at\;23^{\circ}C$ and electrochemical stability window to 4.8V. In the impedance spectra of the cells, which were constructed by lithium metals as electrodes, interfacial resistance increased due to growth of passivation layer during storage time and remarkable difference was not observed with content of $SiO_2$. In the impedance spectra of the lithium ion polymer batteries consisted of $LiClO_2$ and mesophase pitch-based carbon fiber(MCF), ohmic cell resistance of $SiO_2-free$ PGE was changed continuously with number of cycle, but those of $SiO_2-dispersed$ PGEs were not. Discharge capacity of the PGE containing $20wt\%\;SiO_2$ showed 132 mAh/g at 0.2C rate and $85\%$ of discharge capacity was retained at 2C rate.

Synthesis of Lithium Manganese Oxide by a Sol-Gel Method and Its Electrochemical Behaviors (졸-겔 방법에 의한 LiMn2O4의 합성 및 전기화학적 거동)

  • Jeong, Euh-Duck;Moon, Sung-Wook;Lee, Hak-Myoung;Won, Mi-Sook;Yoon, Jang-Hee;Park, Deog-Su;Shim, Yoon-Bo
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.4
    • /
    • pp.229-235
    • /
    • 2003
  • A precursor of lithium manganese oxide was synthesized by mixing $(CH_3)_2CHOLi\;with\;Mn(CH_3COO)_2{\cdot}4H_2O$ in ethanol using a sol-gel method, then heat-treated at $400^{\circ}C\;and\;800^{\circ}C$ in air atmosphere. The condition of heat treatment was determined by thermogravimetric analysis/differential thermogravimetric analysis (TGA/DTA). The characterization of the lithium manganese oxide was done by X-ray diffraction (XRD) spectra and scanning electron microscopy (SEM). The electrochemical characteristics of lithium manganese oxide electrode for lithium ion battery were measured by cyclic voltammetry (CV), chronoamperometry and AC impedance method using constant charge/discharge process. The electrochemical behaviors of the electrode have been investigated in a 1.0M $LiClO_4/propylene$ carbonate electrolyte solution. The diffusivity of lithium ions, $D^+\;_{Li}\;^+$, as determined by AC impedance technique was $6.2\times10^{-10}cm^2s^{-1}$.

AC impedance study on the interface between organic electrolyte and amorphous $WO_3$ thin film relating to the electrochemical intercalation of lithium (비정질 $WO_3$ 박막과 전해질 계면에서의 리튬 층간 반응의 교류 임피던스 해석)

  • Kim Byoung-Chul;Ju Jeh-Beck;Sohn Tae-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.33-39
    • /
    • 1998
  • To AC impedance study was performed in this study on the interfacial reaction between organic electrolyte and amorphous tungsten oxides thin film, cathodically coloring oxide, prepared by e-beam evaporation method in the 1 M $LiClO_4/PC$ organic solution. The electrochemical reactions at the interface were analyzed by the transient method and the complex impedance spectroscopy. The impedance spectrums showed that the electro-chemical intercalation of lithium cations was consisted of the following three steps; the first step, the charge transfer reaction of lithium cation at the interface between amorphous tungsten oxides thin film and the organic electrolyte, the second step, the adsorption of lithium atom on the surface of amorphous tungsten oxides thin film, and then the third step, the absorption and the diffusion of lithium atom into amorphous tungsten oxides thin layer. The bleaching and the coloring characteristics of amorphous tungsten oxides thin film were explained in terms of thermodynamic and kinetic variables, the simulated $R_{ct},\;C_{dl},\;D$ and $\sigma_{Li}$ by CNLS fitting method. Especially it was found that the limiting values of electrochromic reaction were the molar ratio of lithium, y=0.167 and the electrode potential, E=2.245 V (vs. Li).

Image Reconstruction Using Iterative Regularization Scheme Based on Residual Error in Electrical Impedance Tomography (전기 임피던스 단층촬영법에서 잔류오차 기반의 반복적 조정기법을 이용한 영상 복원)

  • Kang, Suk-In;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.272-281
    • /
    • 2014
  • In electrical impedance tomography (EIT), modified Newton Raphson (mNR) method is widely used inverse algorithm for static image reconstruction due to its convergence speed and estimation accuracy. The unknown conductivity distribution is estimated iteratively by minimizing a cost functional such that the residual error namely the difference in measured and calculated voltages is reduced. Although, mNR method has good estimation performance, EIT inverse problem still suffers from ill-conditioned and ill-posedness nature. To mitigate the ill-posedness, generally, regularization methods are adopted. The inverse solution is highly dependent on the choice of regularization parameter. In most cases, the regularization parameter has a constant value and is chosen based on experience or trail and error approach. In situations, when the internal distribution changes or with high measurement noise, the solution does not get converged with the use of constant regularization parameter. Therefore, in this paper, in order to improve the image reconstruction performance, we propose a new scheme to determine the regularization parameter. The regularization parameter is computed based on residual error and updated every iteration. The proposed scheme is tested with numerical simulations and laboratory phantom experiments. The results show an improved reconstruction performance when using the proposed regularization scheme as compared to constant regularization scheme.

Microsturcture and Electrical Properties of Yttria Stabilized Zirconia Films Prepared by Doctor Blade Method (닥터 블레이드법에 의해 제조된 이트리아 안정화 지르코니아 박막의 미세구조와 전기적 특성)

  • Lee, Yu-Gi;Park, Jong-Wan
    • Korean Journal of Materials Research
    • /
    • v.6 no.2
    • /
    • pp.166-174
    • /
    • 1996
  • 경제적이고 단순성의 공정특성을 갖는 닥터 블레이드법을 이용하여 평판형 고체산화물 연료전지의 고체전해질용 이트리아 안정화 지르코니아 박막을 제조하였다. 슬러리의 최적 제조조건과 그린 필름의 최적 소성조건을 얻었으며, 이 제조 조건에서 제조된 전해질의 결정구조, 미세구조 그리고 전기적 성질을 각각 X-선 회절, 주사전자현미경 그리고 교류 임피던스 분석기를 이용하여 조사하였다. 동량의 8mol% 이트리아를 첨가한 경우, 닥터 블레이드법에 의해 제조된 이트리아 안정화 지르크니아 박막은 금형가압성형법에 의해 제조된 이트리아 안정화 지르코니아 펠렛과 거의 비슷한 전기전도도를 나타내었다. 닥터 블레이드법에 의해 제조된 이트리아 안정화 지르크니아 박막의 경우, 8mol%이트리아를 첨가한 경우의 전도도가 3mol%이트리아를 첨가한 경우 보다 993K 이상과 523K 8mol% 이트리아를 첨가한 경우의 전도도가 3mol%이트리아를 첨가한 경우의 전도도가 3mol%이트리아를 첨가한 경우 보다 993K이상과 523K이하의 온도에서는 더 높고, 523-933K사이의 온도구간에서는 낮게 나타났다. 게다가, 모든 시편에 있어서 전체 전도도에 대한 벌크 전도도의 기여도에 대한 기여도보다 더 크게 나타났다.

  • PDF

Phase boundary estimation with effective initial guess in electrical impedance tomography (전기 임피던스 단층촬영 기법에서 효과적인 초기치 설정을 통한 상 경계 추정)

  • Kim, Bong-Seok;Kim, Sin;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.16 no.3
    • /
    • pp.211-216
    • /
    • 2012
  • In the phase boundary estimation problem, the estimation performance depends on the initial guess. However, there is no information on the number of bubbles and those positions for the initial guess in real flows. Therefore, it is very important to set appropriate initial guesses from prior information. In this paper, in order to set initial guesses for estimating the phase boundaries in two-phase flows, first, unknown resistivity distribution was estimated using the difference reconstruction method. After that, an adaptive threshold value was automatically computed using intermodes method. Based on this value, the number of bubbles and the initial position were determined. The numerical experiments have been performed to evaluate the estimation performance of the proposed method.