• Title/Summary/Keyword: 전기임피던스

Search Result 1,220, Processing Time 0.027 seconds

Setting Characteristic Assessment of Cementitious Materials using Piezoelectric Sensor (압전소자를 이용한 시멘트계 재료의 응결 특성 평가)

  • Lee, Chang Joon;Lee, Jun Cheol;Shin, Sung Woo;Kim, Wha Jung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.389-395
    • /
    • 2016
  • The evolution of electro-mechanical impedance (EMI) of the piezoelectricity (PZT) sensor was investigated to determine the setting times of cementitious materials in this study. The PZT sensor coated with non-conductive acrylic resin was embedded in cement paste before casting and the EMI signatures were continuously measured. Vicat needle test and semi-adiabatic calorimetry test were also conducted to justify the validity of EMI senssing technique in setting monitoring of cementitious materials. The results show that significant changes in EMI resonant peak magnitude and frequency during setting process were observed, and that the setting times determined by EMI sensing technique were relevant to the setting times measured by Vicat needle test and semi-adiabatic calorimetry test.

Design of Low-Power Hybrid LNA with Multi-Input for Mobile Ultrasound System (이동형 초음파시스템에 적합한 다중 입력방식의 저전력 혼성 저잡음 증폭기 설계)

  • Song, Jae-Yeol;Lee, Kyung-Hoon;Park, Sung-Mo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.2
    • /
    • pp.64-69
    • /
    • 2014
  • Ultrasound system is one of the complex wireless signal processing systems that are widely used in the fields of modern industry such as medical diagnostics, underwater communications, and sensor-networks. Miniaturization of ultrasound system has been raging recently. In this paper, a hybrid LNA that is suitable for miniaturization and mobile diagnostic ultrasound system has been developed. The proposed LNA has low noise figure of less than 5dB, and the feedback resistor is designed to be electrically adjusted in order to attain the impedance-matching for various ultrasound transducers. It supports the whole ultrasound frequencies from 10KHz to 150MHz frequency band and also provides sleep modes. A gain from -18.8 to -29.5 dB is achieved by adjusting each transducer to fit the system character. Power consumption can be reduced up to 90% in similar performance as compared to the existing LNA.

Segmental Bioelectrical Impedance Analysis(SBIA) for Determining Body Composition (부위별 생체 전기 임피던스법을 이용한 체성분 분석에 관한 연구)

  • 차기철;손정민;김기진;최승훈
    • Korean Journal of Community Nutrition
    • /
    • v.2 no.2
    • /
    • pp.179-186
    • /
    • 1997
  • A new bioelectrical impedance method has been developed and evaluated. The electrodes; were made of stainless steel and electrical interfaces were created by an upright subject gripping hand electrodes and stepping onto foot electrodes. Eight tactile electrodes were in contact with surfaces of both hands and feet; thumb, palm and fingers, front sole, and rear sole. Automatic on-off switches were used to change current pathways and to measure voltage differences for target segments. Segmental body resistances and whole body resistance(RWHOLE)were measured in 60 healthy subjects. Segmental resistances of right arm(RRA), left arm(RLA), trunk(RT), right leg(RRL) and left leg(RLL)were310.0$\pm$61.6$\Omega$, 316.9$\pm$64.6$\Omega$, 25.1$\pm$3.4$\Omega$, 236.8$\pm$31.2$\Omega$ and 237.6$\pm$30.4$\Omega$, respectively. Individual segmental impedance indexes(Ht2/RRA, Ht2/RT, and Ht2 /RLA) were closely related to lean body mass(LBM)as measured by densitometry ranged from r=0.925 to 0.960. Ht2/(RRA+RT+RLA) predicted LBM slightly better(r=0.969) than the traditional index, Ht2/RWHOLE(r=0.964), supporting the accuracy of the segmental measurement. A multiple regression equation utilizing Ht2/RRA, Ht2/RT and Ht2/RRL predicted LBM with r=0.971. Ht2/RRA term of the regression contributed to more than 40$\%$ of the LBM prediction, indicating that lean mass of arm represented whole body LBM more closely than other body segments. The new bioimpedance method was characterized by upright posture, eight tactile electrodes, segmental measurements and utilization of electronic switches in comparison with the traditional method. The measurement with this new method was extremely reproducible, quick and easy to use.

  • PDF

Humidity-Sensitive Characteristics and Reliabilities of Polymeric Humidity Sensors Using 2-Methacryloxyethyl dimethyl 2-hydroxyethyl ammonium brornide (2-Methacryloxyethyl dimethyl 2-hydroxyethyl ammonium bromide를 이용한 고분자 습도센서의 감습 특성 및 신뢰성)

  • Lee, Chil-Won;Gong, Myoung-Seon
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.461-466
    • /
    • 1999
  • The humidity sensor containing ammonium salt was prepared from the copolymer of 2-methacryloxyethyl dimethyl 2-hydroxyethyl ammonium bromide (MDHAB)/MMA/DAEMA = 6/3/1. The humid membrane was fabricated on the gold/alumina electrode by dipping. The impedances were $298k{\Omega},\;11k{\Omega}$, and $2.3k{\Omega}$ at 40%RH, 70%RH and 90%RH, respectively, at $5^{\circ}C$ and the humidity-sensitive characteristics were suitable for low temperature humidity sensor. The temperature-dependent coefficient between $5^{\circ}C$ and $20^{\circ}C$ was found to be $-0.80%RH/^{\circ}C$ and the hysteresis falled in the ${\pm}2%RH$ range. The response time was found to be 38 sec for the relative humidity ranging from 34%RH to 88%RH at $20^{\circ}C$. The reliabilities such as temperature cycle, humidity cycle, high temperature and humidity resistance, electrical load stability, stability of long-term storage and water durability were measured and evaluated for the application as a humidity sensor.

  • PDF

Characteristics of Catalyst and Influence of Promoter for Hydrogen Electrode in Alkaline Fuel Cell (알칼리형 연료전지용 수소극의 촉매 특성과 조촉매의 영향)

  • Yun, Sun Ho;Lee, Hong Ki;Lee, Ju Seong
    • Applied Chemistry for Engineering
    • /
    • v.4 no.2
    • /
    • pp.373-380
    • /
    • 1993
  • The preparation method of Raney nickel catalyst and the effect of promotor for the hydrogen electrode in alkaline fuel cell were investigated with electrochemical methods. The best electrode performance was observed with the Raney nickel which was obtained at $700^{\circ}C$ of sintering temperature and 60:40 of nickel:aluminum. As titanium was added for promotor, the activity of catalyst and characteristic of electrode was improved. Especially, the electrode containing 2w/o of titanium showed the maximum mass activity of 2.4A/g and its mean particle size was $5.7{\mu}m$. The resistance and capacitance of the electrode containing 2w/o of titanium, measured with AC impedance spectroscopy, were calculated to the $0.3{\Omega}cm^2$ and $0.42F/cm^2$, respectively.

  • PDF

The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Control of the Resonance Frequency of a Piezoelectric Transducer with Two Pair of Electodes - (어종식별을 위한 광대역 초음파 변환기의 설계 -I - 전극분할형 압전진동자의 주파수특성 제어 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.3
    • /
    • pp.183-188
    • /
    • 1997
  • A method for designing a broadband transducer was investigated experimentally. Control of the resonance frequency of a Piezoelectric circular transducer with two pairs of electrodes was achieved by varying the inductance of external coil connected across the terminal of one pair of electrodes of transducer. The conductance curves of transducer in water were obtained as a function of the inductance value in mH of the coil used in the tuning. As the tuning inductance is increased in value, the resonance frequency is reduced toward the fundamental frequency of 50 kHz. This interesting result suggest that it is possible to produce a continuously tunable transducer covering a frequency range between 61.3 kHz and 121.7 kHz by varying the inductance value of external coil from 2.7 mH to 15.0 mH. One of other problems in the design and construction of such broadband transducer is the transducer efficiency, but this will be the subject of our future work.

  • PDF

Studies on Formation of Passivation Film on KMFC Anode with Initial Charge Temperature (탄소 부극에서 초기 충전온도별 부동태 피막 형성에 대한 연구)

  • Park, Dong-Won;Kim, Woo-Seong;Choi, Yong-Kook
    • Applied Chemistry for Engineering
    • /
    • v.16 no.4
    • /
    • pp.507-512
    • /
    • 2005
  • When carbon electrode is used as an anode in Li ion battery, passivation film forms on the electrode surface during the initial charge process due to so called Solid-Electrolyte Interphase (SEI). The passivation film formed by solvent decomposition during the initial charge process affects charge/discharge capacity. In this paper, 1 M $LiPF_6,EC:DEC$ (1 : 1, volume ratio) electrolyte with $Li_2CO_3$, at various temperatures, the electrochemical characteristics of passivation film formed on Kawasaki Mesophase Fine Carbon electrode surface were investigated by using chronopotentiometry, cyclic voltammetry, and impedance spectroscopy. Experimental observations indicated that as solvent decomposition occurred, the decomposition voltage was strongly dependent on ionic conductivity, which was low in the process at low temperature. The impedance of passivation film formed during the initial charge process, were dependent on the temperature.

Humidity-Sensitive Characteristics and Reliabilities of Polymeric Humidity Sensor Containing Phosphonium Salts (포스포늄 염을 가진 고분자 습도센서의 감습 특성 및 신뢰성)

  • Kim, Ohyoung;Gong, Myoung-Seon
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.554-560
    • /
    • 1998
  • Vinylbenzyl triphenyl phosphonium chloride(VTPC)/styrenes=3.7 copolymer was prepared for the moisture-absorptive polyelectrolyte dew sensor containing phosphonium salts. The humid membrane was fabricated on the gold/alumina electrode by dipping. The impedances were $11M{\Omega}$, $980k{\Omega}$, $50k{\Omega}$, and $11k{\Omega}$ at 70%RH, 80%RH, 90%RH and 95%RH, respectively, at $25^{\circ}C$ and the humidity-sensitive charactristic was suitable for the dew sensor. The temperature-dependent coefficient between $15^{\circ}C$ and $35^{\circ}C$ was found to be $-0.25%RH/^{\circ}C$ and the hysteresis falled in the ${\pm}2%RH$ range. The response time was found to be 45 sec for the relative humidity ranging from 70%RH to 98%RH at $25^{\circ}C$. The reliabilities such as temperature cycle, humidity cycle, high temperature and humidity resistance, electrical load stability, stability of long-term storage and water durability were measured and evaluated for the application as a dew sensor.

  • PDF

Preparation of Gel Polymer Electrolyte Membranes of Polyvinyl Alcohol and Poly (acrylic acid) for Zn Air Batteries (아연공기전지를 위한 Polyvinyl Alcohol과 Poly (acrylic acid)의 블랜드를 이용한 겔 고분자 전해질막의 제조)

  • Kim, Chanhoon;Koo, Ja-Kyung
    • Membrane Journal
    • /
    • v.22 no.3
    • /
    • pp.208-215
    • /
    • 2012
  • Gel polymer electrolyte membranes were prepared from blends of polyvinyl alcohol (PVA) and poly (acrylic acid) (PAA), by solution-cast technique. The PAA content in the blend varied from 30 to 80 wt%. With the gel polymer electrolyte membranes, Zn air batteries were fabricated. The gel polymer electrolyte membranes were characterized by means of stress-strain test, impedance test. The Zn air batteries were tested by current interrupt method and galvanostatic discharge method. The tensile strength and tensile modulus decreased with increasing PAA content in the gel polymer electrolyte membrane. On the other hand, the ionic conductivity increased with increasing PAA content. The effect of ionic conductivity trend of the gel polymer electrolyte membrane in the Zn air battery was confirmed through current interrupt method and galvanostatic discharge method experiments. The battery with higher PAA content gel polymer electrolyte membrane showed lower IR drop and higher discharge capacity.

Design and Piezoelectric properties of 2-2 piezocomposite Ultrasonic Transducers by means of the Finite Element Methode (유한요소해석법을 이용한 2-2형 압전복합재료 초음파 트랜스듀서의 설계 및 압전특성)

  • Park, Jae-Sung;Lee, Sang-Wook
    • 전자공학회논문지 IE
    • /
    • v.48 no.2
    • /
    • pp.40-46
    • /
    • 2011
  • In this study, PZT-5A green sheet were prepared by using tape casting technique, and the piezoelectric properties of PZT-5A by variation of sintering temperature was investigated. After, design and piezoelectric properties of 2-2 piezocomposite ultrasonic transducers by menas of the FEA. The acoustic impedance and piezoelectric charge constant of the 2-2 type piezocomposite transducer decreased proportionally due to the density decrease caused by the PZT volume fraction decrease. The piezocomposite acoustic impedance were 7~3 MRayl between 0.6 and 0.2 allowing it to be used for a ultrasonic transducer. The resonance characteristics and the electro-mechanical coupling factor were the best when the volume fraction PZT was 0.6. The PZT volume fraction shows the fixed value, 0.6~0.65, approximately within the range between 0.2 and 0.6 while it is increased to decreased over the range. The result of the experiment above confirmed that the 2-2 piezoelectric composites could be used as the ultrasonic transducers.