• Title/Summary/Keyword: 전기신호측정

Search Result 921, Processing Time 0.028 seconds

Cancellation of Moving Artifact in EDA Signal to Detect Drowsiness(II) (졸음 검출을 위한 EDA신호의 동잡음 제거법(II))

  • 고한우;김연호
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.323-329
    • /
    • 1999
  • This paper proposed a method for the cancellation of the moving artifact which was produced during the detection of drowsiness usmg electrodermal activity signal. Two types of wrist electrode were developed to overcome the defect of the steering wheel type electrode which couldn't eliminate the moving artifacts due to driver's movements. Wrist type electrode II which has been modified from electrode type I was most effective for eliminating movmg artifacts compared to wheel type electrode and wrisL type electrode 1. The decIsion criteria(if IRI$\leq$10 and 1.1$\leq$dNz) for detecting moving artifact was determined from the virtual driving experiments. An algorithm which substituted past value of Nz for the current value of Nz whenever an EDA signal satisfied the criteria was developed. The experimental resulls of virtual driving and road test showed that the proposed algorithm had been successfully removed the most of the error due to the moving artifact Therefore, the developed system which use electrode type II and the algorithm might be less influenced by moving artifacts and could measure an accurate arousal state.

  • PDF

Electrical Characteristics on MOS Structure with Irradiation of Radiation (방사선이 조사된 MOS구조에서의 전기적 특성)

  • 임규성;고석웅;정학기
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.644-647
    • /
    • 2001
  • The investigations were discussed on the radiation effects of the electrical properties to the p-type MOS capacitors, which were irradiated by cobalt-60 gamma ray sources. The characteristics of capacitance-bias voltage(C-V) and of dielectric dissipation tarter-bias voltage(D-V) on the capacitors were measured at 1 [MHz] frequency. The microscopic behaviors of spate charges in oxide and silicon-silicon dioxide(Si- $SiO_2$) interface were investigated from the experimental data. The C-V characteristics are statical and convenient for the evaluation of the steady state behavior of carriers and interface states characteristics. While, the distribution and magnitude of space charges in oxide can be found out accurately on the $V_{dp}$ in D-V curves. The density of interface states can be deduced with ease from the magnitude of D-peak at depletion state. Thus, it is also concluded that the D-V curves are more useful and easier than conventional C-V curves for analysis of the microscopic and dynamic behavior of carriers in oxide and Si- $SiO_2$interface.

  • PDF

달을 이용한 천리안위성 기상영상기 노화 경향 분석

  • Kim, Jae-Gwan;Lee, Byeong-Il;Kim, Yong-Seok;Son, Seung-Hui
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.211.2-211.2
    • /
    • 2012
  • 천리안위성은 통신, 해양, 기상 임무를 띤 우리나라 최초의 정지궤도복합위성으로 지난 2010년 6월 27일 성공적으로 발사된 후 동경 128.2도, 적도 상공 약 35,800 km 고도의 정지궤도에 안착되었다. 이 후 약 6개월 여의 궤도상시험 기간과 2개월의 안정화 기간을 거쳐 2011년 4월 1일, 기상청은 위성자료 서비스를 위한 정규운영을 시작하였다. 천리안위성의 기상탑재체인 기상영상기는 다중채널 복사계로 한반도 주변뿐만 아니라 전 지구적 기후 변화 및 대기 운동 그리고 급변하는 기상상황을 감시하기 위해 실시간 관측과 전송 시스템을 갖추고 있다. 이 기상영상기를 운용하는 기상청 국가기상위성센터 지상국에서는 자료수신 및 영상전처리시스템을 갖추고 수신된 위성신호로부터 영상 분리 후 복사보정 및 기하보정을 수행하며, 위성자료배포시스템을 통해 일정 시간 간격 내에 사용자들에게 처리 자료를 배포하고 있다. 영상 복사보정은 기상영상기 내의 각 채널별 디텍터가 감지한 지구복사휘도의 전기적 신호를 지상에서 복사휘도와 휘도온도 값으로 변환하는 작업이다. 절대검정체로서 흑체와 우주보기 값을 이용하는 적외채널과 달리, 가시채널 디텍터는 절대검정체가 탑재되어있지 않기 때문에 우주보기 값 외에 대리검정 방법을 이용한다. 이러한 가시채널 노화도 분석에 달 관측을 통한 비교 분석이 한 방법으로 제시되고 있다. 천리안위성 기상영상기의 정규운영 1년간의 가시채널 디텍터의 노화도는 6 % 이내로 측정되었고, 이는 일반적인 정지궤도위성 센서의 노화도인 6 % 내외 값 변화량에 견주어 잘 운용되고 있음을 시사한다. 본 논문에는 천리안위성 기상영상자료의 품질 및 매개변수의 변화 경향도 함께 제시하였으며, 달을 이용한 기상영상기 노화 분석과 보정에 관한 내용을 싣고 있다.

  • PDF

LYRYNGEAL ADJUSTMENTS FOR KOREAN CONSONANTS (한국어 파열음에 대한 후두내근의 역할)

  • ;H. Hirose
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1991.06a
    • /
    • pp.15-15
    • /
    • 1991
  • 한국어 자음에 대한 생리적인 분류는 조음점 및 조음발법에 따라 다시 세분화할 수 있는데 그중에서 조음발법에 따라 파열음, 마찰음, 파찰음 및 비음들 여러가지로 분류할 수 있다. 그중 특히 파열음은 그 개방하는 방법에 따라 연음(lenis), 경음(glottalized) 및 기식음(aspirated)등으로 구분하는데 이러한 각음을 육안으로 확인하면 모음이 발성되기 위한 성대진동이 있기전의 자음을 위한 성대의 운동의 현상을 보면 기식음에서는 성대열림이 가장 크고 연음에서도 열림이 크지만 기식음보다는 적고 경음에서는 성대의 열림이 가장 작았다. 이러한 현상은 후두내시경에 의해 쉽게 확인할 수 있었는데 이것을 과학적으로 규명하기 위해서는 여러연구에 의해 가능하나 흔히 후두근전도 검사에 의한 성대내전근과 외전근의 역할의 차이를 비교함으로서 가능해지리라 예상되어 본 연구를 시행하였다. 사용된 문형 또는 단어는 한가지를 제외하고는 모두 의미있는 단어를 사용하였으며 EMG recording을 위해 사용된 근육은 후두내전근인 Vocalis muscle과 후두외전근인 Posterior cricoarytenoid muscle이 사용되었고 전기신호는 computer data processing system에 의해 분석되어졌다. 결과는 내시경에 의한 성대열림의 거리측정 결과를 분석함과 동시에 후두내근에 대한 근전도검사에 의한 분석을 토대로 하였으며 이를 간단히 설명하면 이제까지 많은 사람들은 한국어 자음에 대한 각각의 특징적인 현상들을 주로 성대내전근의 역할에 의해 규명하였으나 본 결과로는 성대내전근의 역할도 중요하지만 성대외전근의 역할 또한 상호 연관성을 가지면서 매우 중요한 역할을 한다는 점이다.for the Isotropic plates can be used. Use of some coefficients can produce "exact" value for laminates with such configuration.trap with 2.88[eV] deep of injected space charge from the chathode in the crystaline regions. The origin of ${\alpha}$$_2$ peak was regarded as the detrapping process of ions trapped with 0.9[eV] deep originated from impurity-ion remained in the specimen during production process of the material, in the crystalline regions. The origin of ${\beta}$ peak was concluded to be due to the depolarization process of "C=0"dipole with the activation energy of 0.75[eV] in the amorphous regions. The origin of ${\gamma}$ peak was responsible to the process combined with the depolarization of "CH$_3$", chain segment, with the activation energy of carriers from the shallo

  • PDF

5-bit FLASH A/D Converter Employing Time-interpolation Technique (시간-보간법을 활용한 5-bit FLASH ADC)

  • Nam, Jae-Won;Cho, Young-Kyun
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.9
    • /
    • pp.124-129
    • /
    • 2021
  • A time-interpolation technique has been applied to the conventional FLASH analog-to-digital converter (ADC) to increase a number of quantization level, thus it reduces not only a power dissipation, but also minimize an active chip area. In this work, we demonstrated 5-bit ADC which has 31 quantization levels consisting of 16 conventional voltage-mode comparators and 15 time-mode comparators. As a result, we have achieved about 48.4% voltage-mode comparator reductions. The ADC is fabricated in a 14nm fin Field-effect transistor (FinFET) process with an active die area of 0.0024 mm2 while consuming 0.82 mW through a 0.8 V supply. At 400-MS/s conversion rate, the ADC performs 28.03 dB SNDR (4.36 ENOB) at 21MHz input frequency.

A Scheme of Identity Authentication and Anomaly Detection using ECG and Beacon-based Blockchain (ECG와 비콘 기반의 블록체인을 이용한 신원 인증 및 이상징후 탐지 기법)

  • Kim, Kyung-Hee;Lee, Keun-Ho
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.69-74
    • /
    • 2021
  • With the recent development of biometric authentication technology, the user authentication techniques using biometric authentication are increasing. Various problems arised in certification techniques that use various existing methods such as ID/PW. Therefore, recently, a method of improving security by introducing biometric authentication as secondary authentication has been used. In this thesis, proposal of the user authentication system that can detect user identification and anomalies using ECGs that are extremely difficult to falsify through the electrical biometric signals from the heart among various biometric authentication devices is studied. The system detects user anomalies by comparing ECG data received from a wrist-mounted wearable device-type ECG measurement tool with identification and ECG data stored in blockchain form on the database and identifying the user's location through a beacon system.

Development of Brain-machine Interface for MindPong using Internet of Things (마인드 퐁 제어를 위한 사물인터넷을 이용하는 뇌-기계 인터페이스 개발)

  • Hoon-Hee Kim
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.6
    • /
    • pp.17-22
    • /
    • 2023
  • Brain-Machine Interfaces(BMI) are interfaces that control machines by decoding brainwaves, which are electrical signals generated from neural activities. Although BMIs can be applied in various fields, their widespread usage is hindered by the low portability of the hardware required for brainwave measurement and decoding. To address this issue, previous research proposed a brain-machine interface system based on the Internet of Things (IoT) using cloud computing. In this study, we developed and tested an application that uses brainwaves to control the Pong game, demonstrating the real-time usability of the system. The results showed that users of the proposed BMI achieved scores comparable to optimal control artificial intelligence in real-time Pong game matches. Thus, this research suggests that IoT-based brain-machine interfaces can be utilized in a variety of real-time applications in everyday life.

Analysis of Magnetic Multi-layers by RBS and PIXE (후방산란법(RBS)/양성자 여기 X-선 방출법(PIXE)을 이용한 다층자성박막의 두께 및 조성 정량분석)

  • 송종한;김태곤;전기영;황정남;신윤하;김영만;장성호;김광윤
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.6
    • /
    • pp.272-277
    • /
    • 2001
  • A spin valve structure of Ta/NiFe/CoFe/Cu/CoFe/Ru/CoFe/FeMn/Ta which has a synthetic antiferromagnet (CoFe/Ru/CoFe), was fabricated by using a magnetron sputtering system. The thickness and composition of magnetic free and pinned layers affect the magnetic properties such as exchange interaction strength of each layer and so on. Even though Rutherford Backscattering Spectrometry (RBS) has advantages of quantitative and non-destructive analysis, it is almost impossible to determine the thickness and composition of magnetic thin films using lBS because of its poor mass resolution for a higher atom number (Z>20). In this study, quantitative analysis of the element composition and thickness for the spin valve sample was performed by combining both Proton Induced X-ray Emission Spectrometry (PIXE), which is one of element specific analysis techniques, and grazing-exit RBS with a highly improved depth resolution and absolute quantitative analysis. For the quantitative analysis, standardization of PIXE was carried out with NiFe, CoFe, and FeMn layers, which are one of constituent layers of spin valve films. Through PIXE standardization and the aid of PHE experimental results of the spin valve sample, ire overlapped signal in a grazing-exit RBS spectrum were successfully resolved and the thickness of the Ru layer was determined with a resolution of ∼1 .

  • PDF

Brain-Waves Analysis according to Ego-state and OK-gram of Transactional Analysis Theory (교류분석이론의 자아상태와 인생태도에 따른 뇌파 분석)

  • Jeong, Cheon-Soo;Kim, Jung-Sam;Kim, Chong-Yeal
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.858-863
    • /
    • 2014
  • Through this study, we found out whether to measure objectively by using Transactional Analysis(TA) evaluating their own growth and benefit of health through the change of Ego-state, the personality structure and brain waves monitoring electric signals occurring in the brain of the human biological signals. According to the results of brain-wave test, M-type is brain-waves of healthy adults and a, ${\beta}$ were dominantly observed in the occipital while not sleeping. In particular, ${\beta}$ appears widely throughout the brain during nervous or concentrating metal activities and unlike N-type experimenters, ${\beta}$ was found to be dominant in M-type experimenters even in stable condition. N-type is brain waves of healthy adults and a, ${\beta}$ were dominantly observed in the occipital while not sleeping. In particular, unlike nervous or concentrating M-type, there was no noise such as tension and blink while resting. In addition, it turned out that subjects with high levels of A ego do not return quickly to the stable state and show a lot of Blinking and swallowing saliva, noise regardless of the pattern of Egogram. And brain waves of 11 people that the difference in data of OK-gram and Ego-state is the same in all items or less than -5 showed a low amplitude of $20{\mu}V$ in general. In conclusion, this study identified that the theory of personality pattern of Transactional Analysis Theory and brain-wave findings are consistent and also found out that brain waves are also associated according to each Ego-state of Egogram.

A study on electroreflectance in undoped n-GaAs (불순물이 첨가되지 않은 n-GaAs에서의 Electroreflectance에 관한 연구)

  • 김인수;김근형;손정식;이철욱;배인호;김상기
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.2
    • /
    • pp.136-142
    • /
    • 1997
  • An/n-GaAs(100) Schottky barrier diode has been investigated by using electoreflectance(ER). From the observed Franz-Keldysh oscillatins(FKO), the internal electric field(Ei) of the sample is $5.76\times 10^{4}$V/cm at 300 K. As the modulation voltage($V_{ac}$) IS changed, the line shape of ER signal does not change but its amplitude various linerly. For increasing forward and reverse dc bias boltage($V_{bias}$), the amplitude of ER signal decreases. The internal electric field decreased from $19.3\times 10^4\sim4.39\times10^4$V/cm as $V_{bias}$ INCREASES FROM -5.0 V TO 0.6 V. For Au/n-GaAs the valve of built-in voltage($V_{bi}$) determined from the plot of $V_{bias}$ versus $E_i^2$ is 0.70 V. This value agrees with that observed in the plot of $V_{bias}$ versus amplitude of FKO peak. In addition, the carrier concentraion(N) and potential barrier($\Phi$) of the sample at 300 K are found to be about $2.4\times 10^{16}\textrm{cm}^{-3}$ and 0.78 eV, respectively.

  • PDF