• Title/Summary/Keyword: 전기신호측정

Search Result 918, Processing Time 0.029 seconds

Development Study on the Prototype of Level Measurement System of Launch Vehicle Propellant Tanks (추진제 충전량 측정시스템 시제 개발 연구)

  • Shin, Dong-Sun;Han, Sang-Yeop;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.590-593
    • /
    • 2010
  • The processes of supplying propellants into propellant tanks play important roles during launch preparation of satellite launch vehicle. The total weight of launch vehicle greatly depends on the accuracy of filling quantity of propellant during launch preparation. Among propellants used for launch vehicles a cryogenic propellant such as liquid oxygen is widely adapted as an oxidizer for launch vehicles. Such cryogenic propellant usually resides in a propellant tank as two-phase fluid with liquid and gas, which needs an accurate level measurement system to detect the position of propellant surface precisely. In this paper the fabricating process of a level measurement system using capacitance type with three electrodes is analyzed. In addition, the change of electric signal according to the height of liquid is verified by testing the level measurement system under consideration. The results of tests shows as expected the linear trend of voltage according to the change of water height in a tank.

  • PDF

Measurement of Sulfur Dioxide Concentration Using Wavelength Modulation Spectroscopy With Optical Multi-Absorption Signals at 7.6 µm Wavelength Region (7.6 µm 파장 영역의 다중 광 흡수 신호 파장 변조 분광법을 이용한 이산화황 농도 측정)

  • Song, Aran;Jeong, Nakwon;Bae, Sungwoo;Hwang, Jungho;Lee, Changyeop;Kim, Daehae
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.293-303
    • /
    • 2020
  • According to the World Health Organization (WHO), air pollution is a typical health hazard, resulting in about 7 million premature deaths each year. Sulfur dioxide (SO2) is one of the major air pollutants, and the combustion process with sulfur-containing fuels generates it. Measuring SO2 generation in large combustion environments in real time and optimizing reduction facilities based on measured values are necessary to reduce the compound's presence. This paper describes the concentration measurement for SO2, a particulate matter precursor, using a wavelength modulation spectroscopy (WMS) of tunable diode laser absorption spectroscopy (TDLAS). This study employed a quantum cascade laser operating at 7.6 ㎛ as a light source. It demonstrated concentration measurement possibility using 64 multi-absorption lines between 7623.7 and 7626.0 nm. The experiments were conducted in a multi-pass cell with a total path length of 28 and 76 m at 1 atm, 296 K. The SO2 concentration was tested in two types: high concentration (1000 to 5000 ppm) and low concentration (10 ppm or less). Additionally, the effect of H2O interference in the atmosphere on the measurement of SO2 was confirmed by N2 purging the laser's path. The detection limit for SO2 was 3 ppm, and results were compared with the electronic chemical sensor and nondispersive infrared (NDIR) sensor.

Development of Time Domain Reflectometry Probe for Evaluation of Copper Concentration in Saline Environment (염수환경에서의 구리 농도 평가를 위한 Time Domain Reflectometry 프로브 개발)

  • Lee, Dongsoo;Lee, Jong-Sub;Hong, Won-Taek;Yu, Jung-Doung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.3
    • /
    • pp.15-24
    • /
    • 2018
  • As electromagnetic waves are affected by electrical conductivity or permittivity, they are widely used to evaluate geotechnical characteristics. In this study, a probe for measuring electromagnetic waves using a time domain reflectometry is manufactured to evaluate heavy metal concentration in saline water. In the experiments, a copper is used as a heavy metal, and a probe is demonstrated with the concentration of copper. Solutions were set for 8 different copper concentration (0, 0.01, 0.05, 0.1, 0.5, 1, 5, 10 mg/L) in saline water with 3% salinity. The probe is coated by electrical insulating materials such as epoxy, top-coat, varnish, acrylic paint, heat-shrinkage tube to measure electromagnetic waves in saline water. The measured signals are compared according to coating material. As results, for probes coated with acrylic paint and heat-shrinkage tube, signal variation is not detected. For epoxy, top-coat, and varnish coated probes, the voltage decreases with an increase of copper concentration. Probes coated by epoxy at once and top coat can estimate under 5 mg/L of copper concentration and the probe coated by epoxy twice can estimate over 5 mg/L of copper concentration. This study shows that the probe using the time domain reflectometry can be used to evaluate the concentration of heavy metal in saline water by coating the probe with insulating material.

Signal-Averaged P Wave Analysis in Patients with Paroxysmal Atrial Fibrillation (발작성 심방세동 환자의 신호평균 P파 분석)

  • 김인영;이종연;이병채;이용희;이종민;김선일;김준수
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • Atrial fibrillation(AF). chronic or paroxysmal is the most frequent arrhythmia in human subjects Duration of P wave in signal-averaged electrocardiography(SAECG) reflects intra-atrial conduction time and therefore. could be used as an electrophysiological marker for atrial conduction chance at the earthy stave. So we apply the analysis method using SAECG to diagnose Paroxysmal atrial fibrillation(PAF) . Subjects Participated for the study consisted of two groups: a control group(n=34) of normal healthy volunteers and a group of AF Patients(n=38) with a documented history of PAF but no other history of cardiac disease. We evaluated the effect of several filtering and determination methods to find the starting and ending feints of the P wavy on its duration. To increase the measurement reliability of P wave duration. the automatic detection method was proposed. Also. to increase the detection rate for PAF risk, the decision threshold value was optimized using receiver operation characteristics(ROC) curve. Results showed that the highest statistical difference (p〈0.001) of the P wane duration between controls and subjects was obtained at the Processing condition, using absolute threshold vague(8.75 $\mu N$) , a least mean square(LMS) high pass filter and 30 Hz cutoff frequency. The most outstanding difference(sensitivity 88 % specificity 64.4 %) between controls and subjects was obtained at the decision threshold value of 112 ms.

Measuring Circuit Design of RI-Gauge for Compaction Control (성토시공관리용 방사성 동위원소 이용계기의 측정회로설계)

  • Kil, Gyung-Suk;Song, Jae-Yong;Kim, Ki-Joon;Whang, Joo-Ho;Song, Jung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.385-391
    • /
    • 1997
  • An objection of this study is to develop a measuring circuit of a gauge using radioisotope for compaction control. The gauge developed in this study makes use of radioisotope with the activity exempted from domestic atomic law and consists of measuring circuits for gamma-rays and thermal neutrons, a high voltage supply unit, and a microprocessor. To obtain meaningful numbers of pulse counts, parallel five and two circuits are provided for gamma-rays and thermal neutrons, respectively. Being simple in electrical characteristics of G-M detector for gamma-rays, pulses are counted through only a shaping circuit. Very small pulses generated from He- 3 proportional detector for thermal neutrons are amplified to the maximum of 50 [dB] and a window comparator accepts only pulses with meaning. To minimize effects of natural environmental radiation and electrical noise, circuits are electrostatically shielded and pulses made by ripples are eliminated by taking frequency of high voltage supplied to the circuit and pulse height of ripples into consideration. One-chip microprocessor is applied to process various counts, results are stored and the gauage is made capable to communicate with PC. Enough and meaningful numbers of pulses are counted with the prototype gauage for compaction control.

  • PDF

Analysis and comparison of textile electrode's electrical characteristics in several shapes for biopotential signals (생체 신호 측정을 위한 섬유전극의 형태에 따른 전기적 특성 분석 및 비교)

  • Lee, Young-Jae;Lee, Kang-Hwi;Lee, Jeong-Whan;Kang, Da-Hye;Cho, Ha-Kyung;Cho, Hyun-Seung;Lee, Joo-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.371-372
    • /
    • 2008
  • Many kinds of electrodes have been developed in various forms and shapes for measurement of bio potential signal. Textile electrode has benefit of collect long tenn data monitoring because of it is non-consciousness, convenient and do not occur skin irritation. However, It is very difficult to acquire available data due to high impedance of electrode and unstable skin-electrode contact which generate motion artifact. Also snap button which usually used as mediator between textile and measurement device cause change of electrical characteristics. In this paper, we inflated textile electrode to stabilize contact and add conductive silver paste between textile and snap button to improve conductance. To compare the performance of two methods, flat or inflated and add conductive paste or not, four types of electrodes are tested on each impedance and SNR by ECG measurement. In result, the first type electrode which flat and non-conductive paste showed the worst performance and the last type electrode which is inflated shape and contain conductive paste show the best performance.

  • PDF

Combinational flexible OLED display device using piezoelectric polymer PVDF (압전폴리머 PVDF를 이용한 복합형 유연 OLED 디스플레이 소자)

  • Le, Sang-Yub;Bea, Byung-Tack;Park, Dong-Hee;Choi, Ji-Won;Choi, Won-Kook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.55-55
    • /
    • 2008
  • 압전폴리머 PVDF(polyvinylidene difluoride)의 기판소재를 기반으로 한 디스플레이 소자를 연구하였다. 압전 폴리머 PVDF의 양면은 두께 300nm정도의 ITO(Indium Tin Oxide)를 TCO(Transparent conducting oxide)로 R2R(roll to roll)증착하였으며, 이를 적외선 계열 Pulsed Laser로 상온 건식 에칭을 통해 패턴해내고, 이후 고진공 환경에서 Alq3 를 기반의 유기발광소자를 제작하였다. 전기적 신호에 대해서 기계적인 작동이 가능한 투명 압전 폴리머 재료를 디스플레이 발광소자의 기판 소재로 사용함으로써, 궁극적으로 발광기능과 더불어 압전효과에 의한 스피커 기능이 한 개의 개체내에서 독립적으로 구현될 수 있도록 설계하고, 기술적으로 실현시켰다는 점이 본 연구의 의의라고 할 수 있다. 이를 위해서, 섭씨 80도 이상의 온도에서 압전 성질을 상실하는 것으로 알려진 PVDF에 대해서 투명산화전극을 레이져를 이용한 비가열식 승화방법을 통해 패턴화하는 것을 사용했으며, 밀리미터 단위에서 수십 마이크로미터 수준까지 패턴화할 수 있었다. 제작된 복합형 유연 OLED소자는 기계적으로 휘어진 상태에서도 발광 성능과 스피커 성능을 각각 독립적으로 보였으며, Alq3에 의한 녹색발광을 보임을 확인하였고, 이 경우 양자효율은 약 3%이하의 값을 보였다. 또한 각주파수별 음압(SPL: Sound Pressure Level)측정 결과는 압번폴리머가 가청주파수 영역에서 작동함을 보였으며, 고주파영역에서의 SPL값이 증가하는 전형적인 PVDF사용 필름 스피커의 특성을 보였다. 이로부터 제작된 복합형 소자는 본 연구에서 제안된 목적에서 보인 것과 같이, 두 개의 기능이 서로간의 간섭없이 독립적으로 한 개의 개체 내에서 작동함을 확인할 수 있었다. 본 연구 결과로부터 새로운 유연 전자 소자에 대한 디자인 개념을 제시하고, 기타 다른 기능이 접합된 형태의 신개념 전자 소자를 제안하는 것도 가능할 것으로 기대된다.

  • PDF

Effect of electrolyte composition on Cu thin film by electroplating (전해액 조성이 전기도금으로 제작된 구리박막의 특성에 미치는 영향)

  • Song, Yoo-Jin;Seo, Jung-Hye;Lee, Youn-Seoung;Yeom, Kee-Soo;Ryu, Young-Ho;Hong, Ki-Min
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.95-99
    • /
    • 2008
  • Cu has been used for metallic interconnects in ULSI applications because of its lower resistivity according to the scaling down of semiconductor devices. The resistivity of Cu lines will affect the RC delay and will limit signal propagation in integrated circuits. We investigated the electrolyte effects of the electroplating solution in the resistivity value of Cu films grown by electroplating deposition (EPD). The resistivity was measured with a four-point probe and the material properties were investigated with XRD (X-ray Diffraction), AFM (Atomic Force Microscope), FE-SEM (Field Emission Scanning Electron Microscope) and XPS (X-ray Photoelectron Spectroscopy). From these experimental results, we found that the electrolyte condition plays an Important role in formation of Cu film with lower resistivity by EPD.

  • PDF

Wideband horn antenna including circular-polarizer and straight-type mode-converter for Ka-band (Ka-대역 원형 편파기와 직선구조 모드 변환기를 포함한 광대역 혼 안테나)

  • Jung, Young-Bae
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.299-304
    • /
    • 2011
  • In this paper, the circular polarized horn antenna composed of circular polarizer and impedance transformer is designed, and fabricated. For the circular polarizer, two types of the polarizer are designed and the electrical performance of them is compared; rectangular waveguide polarizer with $45^{\circ}$-inclined dielectric slab and oval shaped one. Straight type mode converter has a stepped impedance structure and plays a role of converting waveguide TE mode into coaxial TEM mode, and the proposed antenna is designed to directly connect with active components using the feed-through in the input port of the mode converter. Fabricated antenna has the wideband performance, VSWR<1.5 and Axial ratio < 1.0dB, ranging from 30.085 to 30.885 GHz, and the antenna gain is 6.7~7.0 dBi.

Degradation Diagnosis of Complex System Using Regression Analysis (회귀분석을 이용한 복합 시스템의 열화진단)

  • 김성홍;박재준;김재환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.39-45
    • /
    • 1999
  • Because of internal voids in insulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and nrluction of the insulation life. 1berefore the necessity for establishing a rrethod to diagnose the aging of insulation materials and to predict the breakdown of insulation has becorne irrportant. From this viewpoint, our studies diagnose insulation degradation using the rrethod of computer sensing system, which has PD and acoustic emission(AE) sensing system. To use advantages of these two methods can be used effectiveiy to search for treeing location and PD in sorre materials. In analysis rrethod of degradation, we analyzed the PD and AE pulses by regression analysis, corrpared to these obtained the correlation coefficient and retermination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. This has a similar teIlrency to the results of the research by Yoshimura and Fujita.Fujita.