• Title/Summary/Keyword: 전기신호측정

Search Result 921, Processing Time 0.033 seconds

The Detection of Calibration Signal for Test of the Partial Discharge Measurement (부분방전 측정 시험을 위한 기준 신호 검출)

  • Lee, Yong-Sung;Lee, Kyoung-Yong;Choi, Yong-Sung;Lee, Chang-Su;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.316-318
    • /
    • 2004
  • 본 논문은 부분방전검출 시험 전에 수행하는 Calibration 신호 주입 및 검출 방법에 대한 연구이다. 사용된 시료는 활선상의 배전용 XLPE 케이블이다. 실험방법은 50kV 내전압기 (750-2CTS, Hipotronics)로부터 공급된 Calibration 신호를 Lemke (LDP-5, LDIC), 오실로스코프 (TDS-3012, Tektronix)와 주파수 분석기 (8563E, HP)를 사용하여 측정하였다. 마지막으로 시험에 사용된 센서는 안테나 특성의 UHF 센서와 고주파 특성의 HFCT 센서이다. 실험결과, Calibration 신호 주입 시 시험 환경 및 센서에 따라 Calibration 신호와 주입방법의 차이가 발생하였다. 따라서 신호의 형태와 인가 전하량에 따른 Calibration 파형과 전하량 변화를 알 수 있었다.

  • PDF

Separation of Partial Discharge Signals and Noise (부분방전 신호와 잡음의 분리)

  • 이승환;유치형;정찬수;김재철;이상철;정양웅
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.21-30
    • /
    • 1999
  • The research for retecting of insulating deterioration in transforrrer has been studied from long ago and the analysis rrethod of combustible gas which is included in insulating oil has been used Recently the spreading effect of the accident is larger than before because of high voltage and large capacity, so on-line detecting system is needed and the study for the estimation of partial discharge signals location has begun. This thesis is the study for the sermating noise signal that is the greatest problem in ultrasonic signal measurement which is one of the method of estimation of partial discharge signals location. Because we can measure the number and location of signal, it is rossible to distinguish between the signal of partial discharge and the external noise. Therefore, we can devolop the credibility of detecting of insulating deterioration in transformer.former.

  • PDF

Study for Coordinate measurement in Wired Tablet (유선 타블렛의 좌표 측정 방법 연구)

  • Hong, Dong-Goo;Ryu, Young-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.437-438
    • /
    • 2008
  • 본 논문은 유선 타블렛에서 공진 회로가 적용된 펜의 위치를 알 수 있는 좌표측정 방법을 소개한다. 현재 연구하고 있는 유선 타블렛은 공진회로가 적용된 펜과 루프코일에 라인안테나가 적용된 패드를 사용한다. 공진회로가 적응된 펜을 패드 위에 놓게 되면, 전자기 유도 현상에 의해 발생된 전류를 측정하여 현재 펜의 위치를 알 수 있다. 루프코일에 라인안테나를 설치하면 이를 Differential coil이라고 부르는데 루프 안테나와 라인 안테나 사이에 흐리는 전류를 알 수 있다. 이때 라인안테나를 기준으로 펜의 위치에 따라서 전류량도 변화하며, 또한 라인 안테나를 기준으로 왼쪽과 오른쪽의 전류의 극성이 다르다. 루프회로에 라인안테나를 겹쳐 놓은 형태인 타블렛의 패드는 라인안테나를 순차적으로 변경해 가면서 공진 회로가 적용된 펜에 의해 전자기 유도 현상에 의해 발생된 전류를 측정하게 되며, 이 측정된 값들을 비교하여 좌표를 알아낼 수 있다. 하지만 그 전류의 변화는 아주 적어 직접적인 신호로는 좌표를 알아낼 수 없다. 그래서 우리는 차등증폭을 이용하여 신호를 증폭시켜 신호를 변형한다. 이 변형된 신호를 이용하여 각 라인안테나에서 측정된 전류세기로 좌표를 알아낸다. 이런 연구에서는 전자기 유도현상에 의해 발생된 전류의 세기를 이용해 실제 윈도우 프로그램에서 펜의 위치를 알 수 있는 방법을 찾고, 구현된 모습을 보여준다.

  • PDF

고전압 측정기술

  • 길경석;이복희;하성철
    • 전기의세계
    • /
    • v.46 no.8
    • /
    • pp.41-46
    • /
    • 1997
  • 최근 가스절연변전소와 같은 컴팩트화된 전력설비의 사용으로 과도전압 및 충격전류의 측정시 오차를 유발시키고 장해를 가져오는 요인 중에서 가장 현저한 것은 전자계 현상이며, 이에 대한 대책과 장해의 제거방법이 검토되어야만 한다. 또한 전력기기의 사용 중에 발생되는 과도전압과 충격전류는 진행파로서 작용하여 발생지점과 측정위치에 따라 달라지므로 종래의 저항분압기, 용량성분압기로는 정확한 측정이 불가능하기 때문에 전기적 신호의 과도적 현상을 직접 감지할 수 있는 측정장치가 필요하다. 다음의 3가지 고전압 측정기술은 피측정대상에 따라 가장 적합하게 제안된 것으로 측정응답을 개선하고 전자계의 영향을 최소화함으로써 정확한 측정이 가능하다.

  • PDF

Analysis of Human Body Channel Based on Impulse Response Signals (임펄스 응답 신호를 이용한 인체 채널 분석)

  • Kang, Taewook;Lee, Jae-Jin;Oh, Wangrok
    • Journal of IKEEE
    • /
    • v.26 no.1
    • /
    • pp.36-42
    • /
    • 2022
  • This study presents an analysis of the human body channel as an electric signal path using body impulse response (BIR). The human body communications (HBC) has recently emerged as an effective signal transmission method to create wireless body area networks (WBAN). We provide body channel characteristics based on measured BIR in a proper experimental environment for the HBC using capacitive coupling with a customized channel sounding device, which can be applied as a guideline for the HBC system design. The frequency response of the BIR, extracted by a customized signal processing for the measure signals, shows the channel path loss (CPS) between 0 MHz and 100 MHz with an average CPS of approximately 46.8 dB. In addition, the relative noise power distributions can provide estimations on the signal to noise ratio at the HBC receiver in terms of capacitor and resistor values in the measured frequency band and the frequency band lower than 3 MHz considering the baseband signal detection.

Development of Exercise Analysis System Using Bioelectric Abdominal Signal (복부생체전기신호를 이용한 운동 분석 시스템 개발)

  • Gang, Gyeong Woo;Min, Chul Hong;Kim, Tae Seon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.183-190
    • /
    • 2012
  • Conventional physical activity monitoring systems, which use accelerometers, global positioning system (GPS), heartbeats, or body temperature information, showed limited performances due to their own restrictions on measurement environment and measurable activity types. To overcome these limitations, we developed a portable exercise analysis system that can analyze aerobic exercises as well as isotonic exercises. For bioelectric signal acquisition during exercise, waist belt with two body contact electrodes was used. For exercise analysis, the measured signals were firstly divided into two signal groups with different frequency ranges which can represent respiration related signal and muscular motion related signal, respectively. After then, power values, differential of power values, and median frequency values were selected for feature values. Selected features were used as inputs of support vector machine (SVM) to classify the exercise types. For verification of statistical significance, ANOVA and multiple comparison test were performed. The experimental results showed 100% accuracy for classification of aerobic exercise and isotonic resistance exercise. Also, classification of aerobic exercise, isotonic resistance exercise, and hybrid types of exercise revealed 92.7% of accuracy.

A Variable Hysteresis Comparator Circuit Controlled by Serial Digital Bits Against Jamming (교란 방어를 위하여 히스테리시스가 시리얼로 제어되는 가변 비교기 회로)

  • Kim, Young-Gi
    • Journal of IKEEE
    • /
    • v.16 no.1
    • /
    • pp.20-27
    • /
    • 2012
  • In order to overcome jamming, a hysteresis tunable monolithic comparator circuit based on a 0.35 ${\mu}m$ CMOS process is suggested, designed, fabricated, measured and analyzed in this paper. To tune the threshold voltage of the hysteresis in the comparator circuit, two external digital bits are used with supply voltage of 3.3V. An improved variable hysteresis comparator circuit controlled by serial digital bits is suggested, designed and simulated to overcome jamming in modern warfare.

Estimating High-Frequency Damping of a Beam through Electro-Mechanical Signatures of Piezoelectric Wafer Mounted on the Beam (보에 부착된 압전웨이퍼의 전기역학적 신호를 통한 고주파수 대역 감쇠 추정)

  • Shin, Yong Jae;Park, Hyun Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.217-229
    • /
    • 2017
  • The high-frequency electro-mechanical signatures, which are excited and received by piezoelectric wafers mounted on a beam, are sensitive to incipient defect in a beam. Predicting the sensing range of the piezoelectric wafers is needed to effectively conduct damage assessment of a beam through utilizing their advantage. Damping of a beam plays the most important role in determining the sensing range among other features. This paper has proposed a scheme for estimating high-frequency damping of a beam through electro-mechanical signatures of piezoelectric wafers mounted on the beam. Considering damping effect while resonance of a beam evolves, wave perspective is adopted to formulate the electro-mechanical signatures of piezoelectric wafers. The damping of a beam is estimated through the least squares method minimizing the difference between the calculated and the measured damping ratio function values which are obtained from formulated and measured electro-mechanical signatures, respectively. The validity of the proposed scheme has been demonstrated through numerical and experimental examples using an aluminum beam with collocated piezoelectric wafers.

A study on a high level radiation dosimetry for reactor (SiC 다이오드를 이용한 원자로내 고준위 방사선 측정에 관한 연구)

  • Lee, Seung-Min;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2622-2624
    • /
    • 2004
  • 본 논문은 원자력 발전소의 원자로 내 고준위 방사선 환경에서의 방사선량 측정에 SiC 다이오드를 이용하여 발생하는 펄스를 관측, 방사선량을 측정하는 기술에 대한 연구이다. 일반적으로 고준위 방사선 환경에서는 방사선측정 센서가 높은 방사선 에너지로 인해 손상되기 쉽다. 이러한 이유로 고준위 방사선 환경에서 내성이 강한 SiC 다이오드를 사용하였다. 방사선 입자를 하나의 에너지로 취급하면 방사선 입자가 센서로 입사하는 경우, 센서에는 방사선 에너지에 따라 약한 에너지가 유기된다. 유기된 에너지는 센서에서 전류의 형대로 출력되면, 이 전류를 신호처리하면 펄스의 형태로 성형이 가능하다. 시간당 성형된 펄스 수는 센서가 받은 방사선량에 비례하며 방사선이 많은 곳에서는 직류의 형태가 된다. 본 논문에서는 약한 전류형태로 출력되는 신호를 성형하여 디지털 신호처리를 하기 위한 펄스 형태로 성형하는데, 필요한 일련의 기술적인 사항에 관하여 연구하였다.

  • PDF

A developments of inexpensive GIS partial discharge diagnostic system using the 9 Channel UHF sensors (9채널 UHF 센서를 적용한 염가형 GIS 부분방전 진단 시스템 개발)

  • Kim, Hong-Seok;Oh, Jae-Hun;Hong, Jung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2021-2022
    • /
    • 2008
  • UHF기법을 적용한 GIS 부분방전 진단 시스템은 가스절연 개폐장치(GIS: Gas Insulated Switchgear) 내부에서 발생하는 부분방전 신호를 측정하여 부분방전 원인을 진단한다. 이러한 부분방전 진단 시스템은 부분방전 신호를 UHF 대역의 고주파/위상 영역에서 분석하여 Digital 신호로 변환하기 때문에 고가의 분석 장비가 필요하므로 시스템의 설치 및 유지 보수비용이 많다. 따라서 부분방전 진단 시스템의 설치에 대하여 대중화하기 어려우며 GIS의 이상 상태가 발생하기 전에는 측정 데이터의 활용이 미비하다. 본 논문에서는 이러한 부분방전 시스템의 설치비용을 절감하고자 센서의 측정을 시간별로 변경하여 측정하는 염가형 부분방전 진단 시스템의 구성에 대하여 기술하며 대용량 데이터의 관리 방안에 대하여 기술한다.

  • PDF