복합화력발전소 에너지절감 사업으로 폐열회수용 흡수식 히트펌프가 설치됨에 따라 부분부하(Partial Load)에서의 성능 데이터 확인을 위해 성능시험을 실시하였다. 부분 부하에서 히트펌프 가동에 따른 운전 데이터 변화는 다음과 같다. 기기냉각수(CCW) 배열 및 배열회수열교환기(HRSG)로부터 공급되는 저압증기(LP STM)의 일부가 히트펌프의 열원으로 공급되므로 지역난방열 생산이 증대된다. 그러나 증기터빈으로 공급되는 저압증기의 유량감소에 따라 증기터빈 출력이 감소된다. 또한 고압 지역난방열교환기(HP-DH) 및 저압 지역난방열교환기(LP-DH)로 공급되는 고압터빈(HPT) 배기증기의 유량 저하에 따라 HP-DH 및 LP-DH의 열생산량도 감소한다. 부분부하에서는 정격부하 대비 히트펌프에 운전에 따른 터빈 출력 저하가 큰 것으로 나타났으며, 이에 따라 부분 부하에서는 발전소 전체의 열 생산 증가량, 전기출력 감소량을 종합적으로 고려하여 히트펌프 운전 여부를 결정해야 한다.
Buildings with heating and cooling systems have been increased, since the requirement of thermal comfort for residents is grown. Heating and cooling systems, have been changed from two separate systems to one multi-function system which includes both heating and cooling. Especially, heat pump heating and cooling system has been adopted for general classrooms in schools since education environment improvement project has been launched. This research suggests the best option for the heat pump heating and cooling system in educational buildings through economic assessments for four alternative systems based on electric heat pump (EHP) and gas engine driven heat pump (GHP), which are most widely used for elementary, middle and high schools. The model buildings are in the Y high school which has 24 classes of new construction building, which will be built soon. Annual energy consumption for alternative systems uses BECS 3.10, which can be used for system simulation.
냉방기기별 하절기 가동률 및 동시사용률 실태를 조사하여 건물의 용도 및 면적 별냉방기기의 시간별 부하률 과 동시사용률, 연간 사용일수 가동시간을 조사하여 냉방기기별 에너지 소비현황 하절기 에너지수급 영향분석을 하고자 하였다. 그리고 국내에 설치된 냉방기기를 대상으로 현장조사 진단을 통해 냉방기기 사용 실태 및 냉방성능을 측정하고, 현장 조사를 통한 만족도와 불만사항을 조사하여 냉방기기 보급 및 운전의 효율을 상승시키고 모든 냉방기기 국산화를 위한 기초자료와 이를 위한 정책적 지원방안 및 향후 냉방기기 기술개발 방향을 제시하고자 한다. 또한 냉방기기별로 문제점을 도출하여 향후 정책제도 개선에 반영할 수 있도록 하였다.
히트 펌프는 지열이나 태양열 등의 신재생 에너지를 이용하거나 기타 폐열을 재활용하여 기존의 전기 히팅 난방 시스템들보다 에너지 소비율을 낮출 수 있다는 장점으로 인해 그린 에너지 시스템으로써 주목을 받아 왔다. 고효율 히트펌프 시스템 설계를 위한 연구는 오랫동안 지속되어 왔지만, 각각의 구성요소가 유기적이며, 변화에 유연한 해석모델은 존재하지 않는다. 따라서 본 연구에서는 공기 열 원식 히트 펌프를 AMESim Software를 이용해 구성하였다. 독자적으로 개발한 스크롤 압축기 해석 모델을 히트펌프 시스템에 조합함으로써 효율 향상 방안을 모색하였으며, 실험 데이터를 이용하여 개발한 해석모델을 검증하였다. 실험 데이터와 개발한 해석 모델을 이용하여 예측된 데이터를 비교한 결과 최대 오차가 10% 이내로 두 데이터가 잘 일치하였다. 본 연구에서 개발한 히트펌프 해석모델은 향후 시제품을 개발하고 효율 향상을 위한 연구 등에 유용하게 사용될 것으로 사료된다.
최근 많은 열에너지를 필요로 하는 열풍식 건조기 대신 에너지 효율이 높은 히트펌프 건조기가 제지, 섬유, 목재, 식품 등 다양한 분야에서 사용되고 있다. 본 논문에서는 냉동 농산물 건조 초기에 전기히터 사용을 최소화하여 에너지 효율을 높이고자, 압축기 출구 고온가스 우회 시스템에 대한 히트펌프 사이클 특성을 이론적으로 고찰하였다. 또한, 추가 열을 확보하기 위하여 외부공기 유입을 위한 댐퍼를 고려하였고 이의 최적화를 통해 에너지 효율 향상이 가능함을 보였다.
Energy performance of electric heater and geothermal source heat pump type hot air dryers are compared in this study. For set temperatures of $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$, radish is dried from initial mass 60 kg until it gets 5 kg, where the difference equals the amount of water removed. As set temperature is increased, drying time is shortened for both electric heater and heat pump types, however energy efficiency is decreased due to increasing electricity consumption. Moisture extraction rate(MER) of electric heater is 2.58~2.84 kg/h, and for heat pump type 2.56~2.71 kg/h, showing little difference between the two types. Specific moisture extraction rate (SMER) of electric heater is 0.94~0.96 kg/kWh, and for heat pump type 1.72~2.21 kg/kWh. SMER of heat pump type is greater by 0.78~1.25 kg/kWh than the electric heater hot air dryer, which is 1.8~2.3 times better in terms of energy efficiency.
본 논문은 전기차 기반의 1톤급 상용차용 통합공조 시스템에 관한 연구이다. 전기 상용차의 경우 화물의 승하차를 위해 문의 개폐가 빈번하게 이루어지기 때문에 열손실이 크게 발생한다. 따라서 냉난방 부하가 승용 전기차에 비해 더 크게 요구된다. 결과적으로 승객이 요구하는 열 쾌적성을 만족하기 위해서 냉난방 시스템이 소비하는 에너지가 승용 전기차 보다 크다. 이러한 단점을 극복하기 위해 효율적인 통합공조 시스템을 적용한 연구를 수행했다. 최종적으로 1톤급의 경상용 전기트럭의 상품성 개선과 전기트럭 분야의 산업 생태계 기반 확충을 위한 고효율 공조 시스템 개발을 위해 냉방을 위한 전동식 압축기와 난방을 위한 히트펌프 시스템의 구상 설계와 해석적 검증을 수행한다.
This paper gives the application method for Electric Heat Rump to DSM programs. The EHP has a function transfer heat and uses electricity as a energy source. In nowadays, as oil prices go up, many People uses the EHP, instead of GHP, the electric power peak load is escalating gradually. By that reason, to achieve successful load leveling, new DSM programs for EHP is needed. Under those circumstances, we discussed about the need of DSM programs for EHP, and the detail method for application EHP to DSM programs in this paper. And we dealt with the site specific test for EHP, and analyzed the test result.
In this study, energy performance of two types of food dryers which are electric heater and heat pump is studied experimentally. With drying chamber temperatures controlled at 45, 50 and $55^{\circ}C$, sliced radish is dried from an initial mass of 90 to final 7 kg. Moisture content, drying time, total power consumption, MER (moisture extraction rate, kg/h) and SMER (specific moisture extraction rate, kg/kWh) are measured and analyzed. As the drying chamber temperature is increased, drying time is shortened but energy efficiency is reduced for both types. For an electric heater dryer, the effect of chamber temperature on drying time is significant but less significant on energy efficiency. For a heat pump dryer, the dependence of chamber temperature on drying time is weak but strong on energy efficiency. Temperature levels have little effect on electric heater dryer performance but strong effect on heat pump dryer which operates on a vapor compression refrigeration cycle. The energy performance of the heat pump dryer is superior with an average SMER of 2.175 kg/kWh which is 2.22 times greater than that of the electric heater dryer with SMER of 1.224 kg/kWh.
The present study has been conducted economic analysis through actual operation of EHP and GHP which are installed at the same building of an university Cost items, such as initial cost, annual energy cost and maintenance cost of each system are considered to analyze LCC and economical efficiency is compared. The initial cost is considered on the basis of actual costs, and annual energy cost is converted into the cost after measuring electricity and gas consumption a day. LCC applied present value method is used to assess economical efficiency of both them. Variables used to LCC analysis are electricity cost escalation rate, natural gas cost escalation rate, interest rate, and service lives and when each of them are 4%, 2%, 8%, and 20 years, results of analysis short that EHP(148,257,306 won) is 8.05%(12,981,990 won) more profitable than GHP(161,239,295 won).
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.