• Title/Summary/Keyword: 전극배열

Search Result 132, Processing Time 0.038 seconds

A Study on the Modified Electrode Arrays in Two-Dimensional Resistivity Survey (2차원 전기비저항 탐사를 위한 변형된 전극배열법에 관한 연구)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.3
    • /
    • pp.59-69
    • /
    • 2001
  • Five kinds of modified electrode arrays were proposed to overcome the weak points of the commonly used arrays using dipole and/or pole in two-dimensional resistivity surveys. The modified pole-pole array was suggested to overcome the inefficiency caused by distant earthing in pole-pole array. Four kinds of modified arrays using dipole were designed to enhance the signal-to-noise ratio of the conventional dipole-dipole and pole-dipole arrays through boosting up the measured potential difference. In the numerical experiments using the two-dimensional modeling and inversion, the effects of the ambient electrical noise and the resolving power were examined and the results showed the validity of the modified arrays proposed in this study.

  • PDF

The Crosshole Resistivity Method Using the Mixed Array (혼합배열을 사용하는 시추공간 전기비저항 탐사)

  • Cho In-Ky;Han Sung-Hoon;Kim Ki-Ju
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.250-256
    • /
    • 2002
  • Resistivity tomography has become an important tool to image underground resistivity distribution. This method has been widely applied to site investigation for engineering and environmental purpose. In resistivity tomography, various electrode arrays can be used and each array has both merits and demerits. For example, the pole-pole array has high signal to noise ratio (S/N ratio), but its resolution is too low. The dipole-dipole array has low S/N ratio, but its resolution is very high. The Pole-dipole may has intermediate Snf ratio and resolution. The modified Pole-dipole array, recently proposed, shows reasonable S/N ratio and resolution, which are comparable to the pole-dipole array. These electrode arrays except the pole-pole array, however, have the problem that the apparent resistivity can diverge at some special electrode Positions. Also, the Pole-Pole array may not reflect the doe resistivity of an anomalous body. In this study, we propose a new electrode array, mixed array, where pole-dipole and modified pole-dipole ways are selectively used with the relative positions of current and potential electrodes. The mixed array has the same level of S/N ratio and resolution as the pole-dipole array and the apparent resistivity does not diverge in the receiver hole. Furthermore, the apparent resistivity using the array can reflect the true resistivity of the anomalous body.

전기 부상 공정에서의 기포 발생량 고찰

  • Park, Yeong-Sik;Kim, Dong-Seok
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2007.05a
    • /
    • pp.361-365
    • /
    • 2007
  • 현재까지 연구된 결과를 요약하면 아래와 같다. 실험에 사용한 전극 중 Pt 전극이 타 전극에 비해 기포 발생량이 많고, 상업적으로 이용 가능하기 때문에 Pt 전극을 이용하는 것이 바람직하다고 사료되었다. Mesh형 전극을 같이 배열한 경우의 기포발생량이 가장 높았으며, mesh형 전극이 longish 형보다는 기포 발생량이 많았다. 기포 발생량이 가장 많은 mesh형 전극을 같이 배열한 상태를 선정하였다. 기포 발생량은 전류가 증가함에 따라 증가하는 경향을 나타내었다. NaCl이 첨가되지 않은 경우의 기포 발생량이 가장 많았으며, NaCl 첨가량이 증가함에 따라 기포 발생량이 감소하였으나 감소량은 적었다.

  • PDF

A STUDY ON THE ROLL-ALONG TECHNIQUE USED IN 2D ELECTRICAL RESISTIVITY SURVEYS (2차원 전기비저항 탐사에 사용되는 ROLL-ALONG 기법에 대한 고찰)

  • WonSeokHan;JongRyeolYoon
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.3
    • /
    • pp.155-164
    • /
    • 2003
  • The validity and efficiency of the roll-along technique widely used in 2-D electrical resistivity survey are analyzed in case of the dipole-dipole and the Wenner-Schlumberger arrays by numerical modelling. The shallow anomalous resistivity bodies are successfully inverted both in the dipole-dipole and in the Wenner-Schlumberger arrays because the shallow data of pseudosection are not omitted by the roll-along technique. However, the deep anomalous resistivity bodies can not be well resolved due to the skip of observed data which is more significant in the Wenner-Schlumberger array having relatively poor horizontal coverage of obtaining data. Carrying out electrical survey adopting the dipole-dipole array, the skip of data is insignificant because it is unfeasible to expand the electrodes to the maximum electrode separation coefficient($n_max$) owing to low S/N ratio. In case of the Wenner-Schlumberger array, however, because it is generally feasible to expand the electrodes $n_max$ to the owing to high S/N ratio, it is highly possible that skip of data from the roll-along technique causes significant distortion of inversion results. Therefore, adopting the Wenner-Schlumberger array having deeper median depth(Edwards, 1977) than do the dipole-dipole array on condition of the same unit electrode spacing( ($a$) ) and $n_max$, it is recommended to determine $a$ based on not $n_max$but $n_prob$free from the skip of observing data and forward electrodes with keeping overlap interval 3/4 of the survey line length in order to reduce the distortion of resistivity structure and perform resistivity survey efficiently. These results are confirmed by numerical modelling.

  • PDF

Unusual Angular Arrangement of Electrodes in Capacitive Heating Device -Thermal Distribution and Clinical Application- (유전 가열장치에서 전극의 각도 배열 -온도 분포의 특성 및 임상 적용-)

  • Seong, Jin-Sil;Chu, Sung-Sil;Kim, Gwi-Eon;John, Juhn-Kyu;Yang, Sung-Wha
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.313-320
    • /
    • 1989
  • In capacitive heating device, which considered efficient for deep heating, parallel arrangement of the electrodes is a serious limiting factor in heating for eccentrically located lesions because it causes overheating of the exposed ipsilateral skin surface, the heating pattern is also frequently inappropriate, and the arrangement tends to be unstable due to the patient's gravity. Therefore we attempted an angular arrangement of the electordes to achieve more homogenous and efficient heating for such lesions. In phantom study, both the thermal profile and thermogram established the heating pattern in this unusual angular arrangement of the electrodes at $60^{\circ},\;90^{\circ}\; and\;120^{\circ}$ angles, respectively. An angular arrangement was also clinically applied to 3 patients. The patients' tolerance was good without significant complication and the thermal distribution was satisfactory. In conclusion, this unusual arrangement of electrodes appears to be promising in the clinical application to the eccentrically located lesions.

  • PDF

Modified Electrical Resistivity Survey for Leakage Detection of a Waterside Concrete Barrage (콘크리트 수변구조물의 누수 탐지를 위한 변형된 전기비저항 탐사 연구)

  • Lee, Bomi;Oh, Seokhoon;Im, Eunsang
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.115-124
    • /
    • 2015
  • A modified electrical resistivity survey has been suggested and applied to a leakage detection problem of concrete barrage. We suggest the modified electrical resistivity methods using electrodes floating on the water and apply line current sources instead of conventional point current sources in order to facilitate simple analysis. In addition, the study introduced the following three variations of modified electrode array: Direct potential array, Parallel potential array and Cross potential array. These arrays were tested and investigated through numerical experiment, physical model experiment and geophysical field exploration in order to verify their applicability to the water leakage detection of a concrete barrage. When water leakage occurred, all kind of array operations demonstrated distinct changes of aspects of potential difference in graphs obtained by not only the numerical and physical model experiments but also geophysical field exploration. Therefore, this modified electrode arrays of electrical resistivity survey, which has been adapted to the concrete barrage, has been found to be a useful method to detect water leakage.