Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.

  • PDF

The Design of Small Size and High Gain Chip Ceramic Dielectric Antenna for Bluetooth Application (소형 고이득 Bluetooth용 칩형 유전체 안테나 설계)

  • 문정익;박성욱;이덕재;왕영성;이충국
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.6
    • /
    • pp.983-993
    • /
    • 2001
  • This paper proposed a novel chip type ceramic dielectric antenna by using the advanced meander line technique that the radiational metals are formed on the face of ceramic dielectric(8$\times$4$\times$1.5 mm, alumina) and both faces of substrate(1.0 mm thickness, FR-4). The performance of the antenna model has a good agreements between measurements and computed results. Resultly, it has a 10 dB return-loss bandwidth(2.4∼2.4835 GHz) and 1.7 dBi measured radiation gain for Bluetooth application. The proposed antenna model can overcome the limited radiation of the small-sized antenna.

  • PDF

Frequency control method of ozonator power supply (오존발생기 구동장치의 주파수제어에 관한 연구)

  • 최규남
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.4
    • /
    • pp.887-893
    • /
    • 1999
  • The characteristics of ozone generator targeted for air or water sterilizing in the vessel utilizing the surface corona discharge between the electrodes on the ceramic substrate was investigated by using the frequency control method. The frequency control was achieved by controlling the degree of resonance between the secondary winding inductance of transformer and the electrode capacitance of ceramic discharge plate, and the range of control was found to be 5 times of discharge current. This frequency control method showed the efficiency of 28 mP ozone generation and the stability within 3.4 % when the input voltage was varied within 40% range. The frequency control method is regarded to be more efficient way of corona discharge control compared to the conventional on/off control or voltage control methods.

  • PDF

A study on characteristics of $SnO_2:F$:F film based on optimum performance Solar cells by APCVD (APCVD법을 이용한 박막 태양전지용 $SnO_2:F$ 투명전극 특성 연구)

  • Ok, Youn-Deok;Kim, Yu-Seung;Yi, Bo-Ram;Kim, Min-Kyoung;Kim, Byung-Kuk;Kim, Hoon;Lee, Jeong-Min;Kim, Hyung-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.65-68
    • /
    • 2009
  • 본 연구에서는 eagle 2000 glass위에 APCVD(atmospheric CVD)증착법으로 $SnO_2$:F 박막을 제조하였다. 공정 온도, doping 농도, TTC(Tin tetrachloride)와 $H_2O$, $CH_3OH$의 조성비를 공정 변수로 두었으며, 각 변수에 대한 전기적, 광학적 특성 및 결정성을 확인하였다. hall measurement를 이용 제작된 박막의 전기적 특성을 확인 하였고, uv-VIS spectroscopy, hazemeer를 이용 박막의 광학적 특성을 확인 하였다. 또한 XRD, FESEM, AFM을 이용 박막의 결정성 및 표면 특성을 확인 하였다. 박막의 결정성을 결정짓는 증착 온도의 경우 $590^{\circ}C$에서 완벽한 Tetragonal rutile 형태의 결정성을 보였으며 $SnO_2$:F film $1{\mu}m$ thickness에서 $10({\Omega}/{\square})$ 내외의 우수한 면저항값과 $30(cm^2/Vs)$ 이상의 mobility값을 확인 하였으며, 가시광영역대 에서 높은 투과율과 우수한 haze값을 얻었다.

  • PDF

A Study on The Photoelectric Characteristics of Dye-sensitized Solar Cell according to Expanding Photo-electrode (염료감응형 태양전지의 광전극 확장에 따른 광전특성 연구)

  • Seo, Hyun-Woong;Kim, Mi-Jeong;Park, Je-Wook;Kim, Ho-Sung;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.305-308
    • /
    • 2007
  • The field of dye-sensitized solar cell (DSC) is being researched actively at present. Because DSC has several advantages to pass the limits of Si solar cells such as a low manufacturing expense, a simple manufacturing process and its transparency. A lot of researches are underway about materials and processes in the field of dye-sensitized solar cell but its structure has been fixed up as the sandwich structure that both edges are used as positive and negative terminals. But the structure as of present is a factor of decreasing efficiency because the more electrons are recombined the further distance from terminal, considering about the characteristic of dye-sensitized solar cell that electrons generated inside cell are moved by diffusion. In this study, we made experiment on expanding the terminal to shorten internal moving distance of electron and compared the results according to the variation of active area to find out the effect of this trial. As a result, we achieved about 15.5% improvement of maximum power and 0.5% improvement of efficiency from terminal-expanded dye-sensitized solar cell of $2cm^{2}$ active area and concluded that the increasing rate of efficiency is raised as the active area becomes wider.

  • PDF

Effect of Fabric Elasticity on Performance of Textile-based ECG-monitoring Smart Wear (소재의 신축성이 직물 기반 심전도 모니터링 의복의 성능에 미치는 영향)

  • Jo, Ja-Yeong;Jang, Se-Eun;Jo, Gil-Su
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2007.05a
    • /
    • pp.39-41
    • /
    • 2007
  • 본 연구는 직물 기반 바이오 모니터링 스마트 의류를 개발하기 위해 의복 소재의 신축성에 따른 심전도 신호 검출 성능과 착용 성능을 평가하여 직물 기반 심전도 의복을 위한 최적 범위를 제안하고자 한다. 이를 위해, 서로 다른 신축률의 편물을 얻기 위해 면/폴리에스테르에 스판덱스 함유율을 0%, 5%, 8%로 다르게 하여 제편하였다. 이 세 가지 소재로 심전도 측정을 위해 동일한 사이즈로 의복을 제작한 후, 금속사를 이용한 자수 기법으로 심전도 전극을 설치하였다. 심장 관련 병력이 없고 평균 BMI가 $20{\sim}24$인 정상 체중의 5명을 대상으로 Biopac MP150을 사용하여 심전도 신호를 검출한 후, 설문지를 사용하여 소재의 신축성에 따른 착용성 평가를 시행하여 신축성에 대한 만족감, 동작용이성, 전반적 쾌적함 등을 Likert 7점 척도로 평가하도록 하였다. 실험 결과, 심전도 신호 검출 성능 측면에서는 8% 라이크라 함유 소재가 가장 우수하였으나, 착용성 측면에서는 5% 소재가 가장 우수한 것으로 파악되었다. 향후 그 수요가 높아질 것으로 예상되는 바이오 모니터링 의복 소재 개발을 위해 기능성과 착용성을 모두 고려한 본 연구 결과가 유용하게 활용될 것이다.

  • PDF

High Performance Electrode of Polymer Electrolyte Membrane Fuel Cells Prepared by Direct Screen Printing Process (직접 스크린 프린팅법으로 제조된 고분자 전해질 연료전지의 고성능 전극)

  • 임재욱;최대규;류호진
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.1
    • /
    • pp.65-69
    • /
    • 2004
  • Screen printing it one of the most popular methods for the fabrication of catalytic layer in electrode of polymer electrolyte membrane fuel cells (PEMFCs) due to its convenience and adaptability. This paper suggests an improved screen-printing method, which is rather simple suppressing the swelling trouble without additive process and competitive with very low Pt loading in comparison with the previous methods. Particularly, the gasket unified MEA made better performances than the other especially at high current area due to blocking effect on the gas leakage during the operation. These methods give us more simplified and faster fabrication chances.

  • PDF

RF MEMS 기법을 이용한 US PCS 대역 FBAR BPF 개발

  • 박희대
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.3
    • /
    • pp.15-19
    • /
    • 2003
  • In This paper, we developed 1.96 GHz air gap type FBAR BPF using ZnO as piezoelectric sputtered by RF magnetron at room temperature. FBAR BPF was fabricated by sputtering bottom electrode (Al), ZnO as piezoelectric and top electrode (Mo) on Si wafer one by one with RF magnetron sputter, then Si was dry etched to make an air hole. XRD test result of fabricated FBAR BPF showed that ZnO crystal was well pre-oriented as (002) and sigma value of XRC was 1.018. IL(Insertion loss) showed excellent result as 1 dB.

Ar 유량 변화에 따라 RF Magnetron Sputterin 법으로 제조된 GZO 박막의 특성변화

  • Jeong, Seong-Jin;Kim, Deok-Gyu;Kim, Hong-Bae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.232-232
    • /
    • 2011
  • 투명전도산화물에 대한 연구가 많이 이루어지고 있으며, 최근 Ga이 도핑된 ZnO의 연구가 많이 되고 있다. 투명전도산화물은 태양전지, 평면디스플레이와 같은 다양한 분야에 응용이 가능하다. 본 연구에서는 RF magnetron sputtering을 이용하여 Ar gas 유량 변화에 따른 GZO 박막을 연구하였다. 기판으로는 유리기판을 사용하였으며, 전기적, 광학적, 구조적인 특성을 조사하였다. 박막의 증착시 초기 압력은 $2.0{\times}10^{-6}$Torr 이하로 하였으며, 증착온도는 상온으로 고정하여 증착하였다. 기판은 Corning 1737 유리 기판을 사용하였고, GZO 타겟은 ZnO : Ga 분말이 각각 97 : 3 wt.%로 소결된 타겟을 사용하였다. Ar 유량변수는 20, 40, 60, 80 sccm으로 변화를 주었다. 유리기판에 증착된 모든 GZO박막은 약 200 nm의 두께로 증착되었으며 모든 GZO 박막에서 85%이상의 투과율을 나타내었다. Ar 유량이 적을수록 투과율을 증가하였으며, 광학적 밴드갭 또한 증가하였다. 공정별로 제작된 모든 GZO박막에서 (002)면의 배향성이 관찰되었고, Ar 유량이 적을수록 박막의 결정성은 향상되었다. Hall 측정 결과 Ar 유량이 20 sccm일 때 전기비저항 $3.46{\times}10^{-3}{\Omega}cm$, 전하의 농도 $3.832{\times}10^{-20}\;cm^{-3}$, 이동도 $4.7cm^2V^{-1}s^{-1}$로 전극으로서의 특성을 나타내었다. GZO 박막의 경우 Ar 유량이 적었을 때 결정성이 높아지고, 전극 특성이 더 우수한 것을 확인할 수 있었다.

  • PDF

액체 속에서의 고전압 펄스 플라즈마 발생 및 분광학적 플라즈마 특성연구

  • Park, Ji-Hun;Kim, Yong-Hui;Jeon, Su-Nam;Park, Bong-Sang;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.549-549
    • /
    • 2013
  • 고전압 펄스 플라즈마를 액체 속에서 발생시켜 수소 스펙트럼의 광학적 특성을 연구하였다. 고전압 펄스 발생 장치인 막스 제네레이터는 용량이 $0.5{\mu}F$인 축전기 5개로 이루어져 있다. 각각의 축전기는 전원 장치를 이용하여 저항을 통해 병렬로 충전되며, 방전 시에는 불꽃 방전 스위치에 의해 동시에 직렬로 연결되어 고전압을 발생시킨다. 따라서, 출력 전압과 전류는 40kV, 3 kA이며 총 에너지는 약 125 J이다. 직육면체 모양의 폴리카보네이트 용기 내부의 양쪽면에는 탐침 모양의 전극이 구성되어 있으며 전극 사이에서 고전압을 가진 플라즈마가 형성된다. 실험에서 액체로는 증류수를 사용하였다. 액체 방전 시 발생하는 수소 스펙트럼을 관측하기 위해 초점거리 30 cm의 monochromator를 이용하였고, 수소 알파선의 656.3 nm와 수소 베타선의 434.1 nm를 관측하였다. 전자 밀도의 측정법으로는 Stark broadening법을 이용하여 측정하였으며, 전자 온도는 Stark profile의 상대적인 전자 밀도의 비를 이용하여 계산하였다. 전자밀도는 실험조건에서 약 $3{\times}10^{15}cm^{-3}$, 전자온도는 약 2.5 eV가 측정되었다.

  • PDF