• Title/Summary/Keyword: 적정 위치 선정

Search Result 153, Processing Time 0.032 seconds

A development of the ground settlement evaluation chart on tunnel excavation (터널굴착에 따른 지반침하 예측을 위한 침하량 평가도표 개발)

  • Park, Chi Myeon;You, Kwang-Ho;Lee, Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1105-1123
    • /
    • 2018
  • The main risk factors of tunnel excavation through urban areas are ground settlement and surface sink which caused by ground conditions, excavation method, groundwater condition, excavation length, support method, etc. In the process of ground settlement assessment, the numerical analysis should be conducted considering the displacement and stress due to tunnel excavation. Therefore a technique that can simplify such process and easily evaluate the influence of tunnel excavation is needed. This study focused on the tunnelling-induced ground settlement which is main consideration of underground safety impact assessment. The parametric numerical analyses were performed considering such parameters as ground conditions, tunnel depth, and lateral distance from tunnel center line, etc. A simplified ground settlement evaluation chart was suggested by analyzing tendency of ground subsidence, lateral influence area and character by depth. The applicability of the suggested settlement evaluation chart was verified by comparative numerical analysis of settlement characteristics.

A Feasibility Study in Forestry Crane-Tip Control Based on Kinematics Model (1): The RR Manipulator (기구학적 모델 기반 임업용 크레인 팁 제어방안에 관한 연구(1): RR 매니퓰레이터)

  • Kim, Ki-Duck;Shin, Beom-Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.111 no.2
    • /
    • pp.287-301
    • /
    • 2022
  • This study aims to propose a crane-tip control method to intuitively control the end-effector vertically or horizontally for improving the crane work efficiency and to confirm the control performance. To verify the control performance based on experimental variables, a laboratory-scale crane was manufactured using an electric cylinder. Through a forward and reverse kinematics analysis, the crane was configured to output the position coordinates of the current crane-tip and the joint angle at each target point. Furthermore, a method of generating waypoints was used, and a dead band using lateral boundary offset (LBO) was set. Appropriate parameters were selected using bang-bang control, which confirmed that the number of waypoints and LBO radius were associated with positioning error, and the cylinder speed was related to the lead time. With increased number of waypoints and decreased LBO radius, the positioning error and the lead time also decreased as the cylinder speed decreased. Using the proportional control, when the cylinder velocity was changed at every control cycle, the lead time was greatly reduced; however, the actual control pattern was controlled by repeating over and undershoot in a large range. Therefore, proportional control was performed by additionally applying velocity gain that can relatively change the speed of each cylinder. Since the control performed with in a range of 10 mm, it was verified th at th e crane-tip control can be ach ieved with only th e proportional control to which the velocity gain was applied in a control cycle of 20 ms.

Parametric Study for Seismic Design of Temporary Retaining Structure in a Deep Excavation by Dynamic Numerical Analysis (동적수치해석을 이용한 대심도 흙막이 가시설 내진설계 변수연구)

  • Yang, Eui-Kyu;Yu, Sang-Hwa;Kim, Dongchan;Kim, Jongkwan;Ha, Ik-Soo;Han, Jin-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.45-65
    • /
    • 2022
  • In this paper, a diaphragm wall that supports soils and rock was modeled using FLAC, a finite difference analysis program, to evaluate the seismic behavior of temporary retaining structures in a deep excavation. The appropriateness of the numerical model was verified by comparing its results with those of the centrifuge test performed in a similar condition. The bending moment distribution along the diaphragm wall shows a very similar tendency, and the maximum acceleration obtained at the backfill and top of the wall shows a difference within 5%. Based on the developed model, a parametric study was conducted in various input earthquake, ground, and excavation conditions. The maximum structural forces and bending moment under earthquake loading were compared with the maximum values during excavation, from which the critical condition that requires a seismic design was roughly sorted out. The maximum bending moment of a wall that retains soil layers increased 17%. Particularly, the axial force of struts located in loose soils increased 32% under 100 years return period of an earthquake event, which strongly is estimated to require seismic design for structural safety.

Prediction of Lifetime of Steel Bridge Coating on Highway for Effective Maintenance (고속도로 강구조물의 효율적 유지관리를 위한 도막수명예측)

  • Lee, Chan-Young;Cheong, Haimoon;Park, Jin-Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.341-347
    • /
    • 2008
  • Among coating systems used for steel bridge coatings on highway such as red lead-pigmented alkyd, chlorinated rubber, waterborne inorganic zinc, inorganic zinc/epoxy/urethane and inorganic zinc/epoxy/fluororesin, evaluation of deterioration degree and prediction of lifetime through regression analysis were carried out for coating systems widely used and grossly degraded. For evaluation of deterioration degree, 75 bridges on highway were selected, and evaluations were carried out according to point offering method regulated by Guideline of maintenance coating for steel bridges used in Korea Expressway Corporation. Lifetime prediction results showed 13.0~13.3 years for the whole nation, 11.8 years for urban and industrial region in the metropolitan area, 13.2 years for rural region except the metropolitan area, 13.5~13.7 years for chlorinated rubber coating systems, and 12.86 years for red lead-pigmented alkyd systems. For prediction of the rest life of coating, we tried to execute parallel translations of standard deterioration curve to current life and deterioration degree for both x and y axes, and it was thought that parallel translation for x axis corresponded to deterioration aspects in actual environment. Maximum and minimum equations were derived from standard deterioration equation by adding and subtracting error values deduced in regression analysis to/from each coefficient in order to establish maintenance coating criteria for overall steel bridges on highway. Whole domain was divided into 8 parts in order to predict the rest life of coating and optimum time of maintenance coating, and maintenance coating criteria for each 8 domains were presented.

Backflow Flow Analysis of Street Inlet drain using Fluent Model (빗물받이 연결관 역류 흐름 해석을 위한 Fluent 모형 적용)

  • Lee, Min Sung;Kim, Jung Soo;Yoo, In Gi;Yoo, Kyu Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.245-245
    • /
    • 2022
  • 최근 국내 기후변화에 따른 국지성 집중호우로 인한 시간당 강우량의 증가로 도로부 유출량의 증가와 배수관거에서의 내수배제 불량에 따른 도심지 내수침수 피해가 증가함에 따라 이를 해결하기 위한 우수유출저감시설이 설치되고 있다. 그러나 대단위의 지하 저류시설의 지속적인 설치는 과밀화된 도심지에서 설치 지하공간의 구조적인 한계 및 적정 설치 위치의 미확보 등의 다양한 문제가 발생하여 저류시설의 침수저감 효과에 대한 추가적이고 새로운 저류시설에 대한 연구가 필요한 실정이다. 이에 내수 침수 저감 및 배수 능력 향상을 위한 도로 배수시설과 연계된 도로 측구부 저류시스템 구축이 필요하다. 이를 위해 역류 방지 및 노면수 저류 빗물받이에 적용되는 부력식 역류차단장치를 개발하였으며, 역류차단장치의 최적 형상 개발을 위해서 기존 빗물받이 연결관과의 통수능 비교 및 분석이 필요한 실정이다. 따라서 본 연구에서는 기존 빗물받이 연결관 및 연결관 내에 역류차단장치가 적용된 역류차단 빗물받이의 흐름분석을 위해 Fluent 모형을 이용하여 3차원 수치모의를 수행하였다. 수치모의 구성으로는 전체 형상을 40×50cm의 빗물받이 유입부와 50×50cm의 빗물받이로 결정하고 격자는 빗물받이 내부의 복잡한 3차원 흐름을 모의하기 위해 1.2~2mm 크기로 생성하였다. 다상유동 해석을 위해 VOF(Volume of Fluid)방법을 적용하였고, 수치해석 방법으로는 비정상류, 난류 모형으로는 SST k-𝜔모형을 적용하였다. 해석조건으로는 김정수(2021) 등이 제시한 4차선 기준 설계빈도별(5~30년) 빗물받이 유입유량을 산정하여 빗물받이 유입조건으로 선정하였으며, 빗물받이와 연결관에서의 통수능력 분석 조건으로는 빗물받이에 기존 연결관이 부착된 조건과 연결관 내에 역류차단장치가 설치되어 역류차단장치가 개방된 조건에서의 통수능을 비교하였으며, 역류상황을 가정한 연결관에서의 통수능을 비교하기 위하여 역류차단장치의 개폐정도를 15도(통수단면 33%감소) 닫힌 상태 및 30도(통수단면 67% 감소) 닫힌 상태 조건을 대상으로 빗물받이와 연결관에서의 흐름을 모의하였다. 수치모의 결과 역류차단장치의 계폐조건에 상관없이 5년 빈도유입량 조건에서는 완전 배수가 되었으며, 개폐조건 15도에서는 10년 빈도의 유입량에서는 완전 배수가 되었으나 20년 빈도 이상의 유입량 조건에서 빗물받이 유입부로의 역류가 발생하였으며, 개폐조건 30도에서는 5년 빈도 이상 유입량 조건에서 빗물받이 유입부로 역류가 발생하는 것으로 나타났다. 특히, 30년 빈도 이상의 유입량부터는 빗물받이 연결관 내에 역류차단장치 개페조건과 관계없이 빗물받이 유입부로의 역류로 인한 도로 침수가 발생하기 때문에 유휴공간인 도로 측구부를 저류공간으로 활용할 수 있는 도로 측구부 저류시스템의 구축은 필수적이라고 판단되며, 유량 조건에 따른 빗물받이 내부 와 흐름과 유출부에서의 유속 변화 특성을 확인하였다. 그러므로 측구 저류조 개발 형상과 연결한 3차원 흐름의 구현 및 분석에 Fluent 모형의 적용이 가능하다고 판단된다.

  • PDF

A Study on the Construction Methods and the Distribution of Proper Spatial Function for Restoring Urban Streams into Close-to-Nature Streams - A Case Study of Hongjecheon(Stream) in Seodaemun-Gu, Seoul - (도시 내 자연형 하천 조성을 위한 적정 공간기능 배분과 조성방안 연구 - 서울시 서대문구 홍제천을 사례로 -)

  • Jung, Tae-Jun;Lee, Kyong-Jae;Han, Bong-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.3
    • /
    • pp.43-55
    • /
    • 2013
  • The purpose of this study is to propose a plan that properly organizes urban close-to-nature streams by evaluating the city park functions, ecological functions and landscape functions required for urban stream and setting up space function suitable for the space. The site of this study is Hongjecheon located in Seodaemun gu of Seoul City, whose length of channel spans 6.12km in total. The plan for the construction of close-to-nature streams had been established from late 2003, and the construction was completed. Evaluation Categories and indications were deduced from 4 stages. First, based on theoretical examination, we made a list of stream and park evaluation categories and added Category about Characteristic of urban streams. Next, we set Final Evaluation Categories and indications through the process of goal-relevance, indication verification, merging similar category. Final Evaluation Categories were deduced such as usage demand, usability(city park functions), biodiversity, inhabitation potential, rarity(ecological functions), historical cultural elements, and landscape Quality(landscape functions). As a result of allotting space functions, zones 1 through 4, got high grades at usage demand, was classified as a civic resort district; zones 5 through 6, close to major green area and remained original landscape, as ecological conservation and restoration district; zones 7 through 8, get high grades at usage demand and usability, as environmentally-friendly use district; and zones 9 through 10, many historical cultural elements and view points, and high green possession rate, as stream scenic district. In addition, detail space function and construction plan for each zones were proposed. As a result of this study, proposed space function assignment considering natural characteristics, humanities and social characteristics and landscape characteristics and is expected to be utilized at reasonable spatial planning considering various functions required for urban stream.

A Study on the Estimation of Ecological Footprint in Gyeongsangbuk-do for Comparison of Environmental Capacity of Each Local Government (자치단체별 환경용량 비교를 위한 경상북도지역 생태발자국 추정연구)

  • Kang, Kee-Rae;Kim, Hee-Chae;Kim, Dong-Pil;Oh, Hyun-Kyung;Cho, Kwang-Jin;Shin, Young-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.6
    • /
    • pp.769-778
    • /
    • 2014
  • The rapid urbanization and increase in population due to industrialization have led to the extension of cities and the reduction in naturality as a necessity. Now, it is the biggest threat to virtuous circle of ecosystem. With the expansion of common recognition that this ecological crisis would be accompanied by the crisis of mankind, many countries all around the world are conducting researches to indicate the optimum consumption level of individual as an index in addition to cross-national environmental indicators such as ESI, EPI and SDI, by measuring environmental consumption of state, local government or individual, and comparing each region. Based on this background, this research was carried out to estimate the environmental capacity of 23 local government in Gyeongsangbuk-do. The result of EF estimation showed that EF value necessary for life per head in Gyeongsangbuk-do was 0.9534, and it showed an ecological deficit of 25.3 percent when analyzing it in consideration of the ecological capacity. Also, among the local governments in Gyeongsangbuk-do, Youngduk-gun displayed the highest EF, and Ulleung-gun displayed the lowest EF. But when analyzing the ecological deficit in consideration of the ecological capacity of each region, Gumi-city showed the greatest ecological deficit, and Youngyang-gun showed the biggest ecological capacity. The environmental capacity estimated in this study is to digitize the ecological capacity and ecological deficit of each local government in Gyeongsangbuk-do. The estimated optimum environmental capacity of each local government suggests the scale of environmental preservation and proper development and furthermore, could be used as fundamental data for persuading members of each local government when selecting a location of development facility or preservation area.

A Case Study on Introducing Vita Parcours as Forest Leisure Sports Facility in Saneum Healing Forest (산음 치유의 숲 Vita Parcours 도입 사례 연구 - Vita Parcours 도입을 사례로 -)

  • Lee, Jin-Kyu;Kim, Ki Weon
    • The Journal of the Korean Institute of Forest Recreation
    • /
    • v.22 no.4
    • /
    • pp.71-81
    • /
    • 2018
  • It is necessary to build a quality-enhancing forest leisure sports facility according to values that value life quality, national forest policy. Vita Parcours (fitness trails) is found to be the activities highly convenient, so their introduction and promotion in Korea should be highly considered. field survey was necessary to explore the possibility of installing Vita Parcours. Several sites were selected, such as Asean recreational forest, Unaksan recreational forest, Yumyeongsan recreational forest, Saneum recreational forest, Jungmisan recreational forest and National center for forest therapy. At these locations, we explored the current status of forest facilities and forest trails. A total number of 31 exercise facilities has been identified and surveyed, some of which are located on the trails (2), alongside the trail (9), alongside trail boundaries (2) or represent facilities suitable for both outdoor and indoor exercise within the forest (18), all of whom provide location for 44 different exercise routines (flexibility exercises (23), endurance (12) and strength exercises (9)). Field work also included identification of forests paths, the total number of whom was 34 paths - 30 identified as trails, 2 as hiking trails, 1 as a forest path for relaxation and healing and 1 as an exploratory path. Regarding the structure and shape of these trails, 32 was straight in shape and only 2 designed as a circular forest trails. Average length of these trails was 652.2m with the highest and the lowest point altitude difference of 60m, on average. Saneum recreational forest provide the most suitable site/environment for Vita Parcours and as a result of this, Saneum recreational forest is proposed as a location to support the endeavors in promotion of these valuable forest fitness trails. Among the forest paths at this site, a forest path which has a length of 1.84km and 73.0m the highest and the lowest point altitude difference was selected as the most suitable, and may be equipped with necessary stations for exercise or obstacles. In addition, if these trails are to be introduced and welcomed by its users, we must assure that they are properly maintained.

Comparison of defect size measured by transthoracic and transesophageal echocardiography with balloon occlusive diameter measured during transcatheter closure of atrial septal defect (경피적 심방중격결손 폐쇄술 시 경흉부 및 경식도 초음파 검사 상의 결손의 크기와 풍선 폐쇄 직경과의 관계)

  • Hur, Kyong;Kim, Jeong Eun;Kim, Yuria;Kwon, Hae Sik;Yoo, Byung Won;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.970-975
    • /
    • 2007
  • Purpose : Accurate measurement of defect size is important in transcatheter closure of atrial septal defect (ASD). We performed this study to analyze the difference between the measured ASD size and balloon occlusive diameter (BOD) by transthoracic (TTE) or transesophageal echocardiography (TEE). Methods : We investigated 78 patients who underwent transcatheter closure of ASD. The defect size and the distance between the surrounding structures were measured by TTE and TEE. The BOD was measured by TEE during cardiac catheterization. Clinical characteristics and echocardiographic data were compared and analyzed. Results : The difference between BOD and diameter by TTE was $4.8{\pm}3.6mm$ on short axis view, $5.4{\pm}3.2mm$ on long axis view. The difference between BOD and diameter by TEE was $3.6{\pm}2.2mm$ on short axis view, $4.2{\pm}3.1mm$ on long axis view. The difference between BOD and the diameter of defects on TTE, TEE had statistically significant positive correlations with the age of the patients, distance between the, defect and posterior atrial septal wall, the distance between the defect and the mitral valve leaflet, and the diameter of defects and the length of the atrial septum on TTE (P<0.05). Conclusion : BOD of ASD can be estimated by the diameter on TTE and TEE. BOD is expected to measure larger, depending on the size of defects, the distance from surrounding structures and the location of defects on echocardiography. Our data offers important information on details of transcatheter ASD closure which can be helpful in predicting suitability and judging the procedural appropriateness during the procedure.

An Importance and Satisfaction Analysis for Improvement Efficiency Use of Waterfront - A Focus on the Waterfront Analysis for Domestic and Foreign Dragon Boat Festival - (친수공간 이용효율성 개선을 위한 중요도·만족도 분석 - 국내·외 드래곤 보트 페스티벌을 위한 친수공간 사례로 -)

  • An, Byung-chul
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.4
    • /
    • pp.86-99
    • /
    • 2016
  • This study was for analyzing the external environment and internal space structure and improving the way of use efficiency in waterfront through the Dragon boat festival to utilize waterfront actively. Through from the four target area, Hongkong, Busan, Incheon and Daejeon, this study was for an importance and satisfaction analysis for users about the element effect on the waterfront use efficiency and the contribution to cultural contents revitalization of waterfront by giving basic data. The result is as follows. First, in the importance analysis about 12 items, modern cultural infra around the waterfront was ranked highest, 8.26 and waterfront landscape, square & openspaces, convenience facilities, transport, green area, quality of viewing space, historic resources, pedestrian, suitability of width, wave, depth, water quality, berth & mooring were ranked in descending order. Second, waterfront landscape was interpreted by rather the external environmental impact according to city size than the matter of spatial structure in target area and judged as an important factor effect on site selection for waterfront. In the analysis of waterfront landscape, the reason of the high satisfaction about domestic target area was that riverside parks were recently made considering their waterfront activities. Viewing space was major infra where people could experience the pleasant waterfront and watch dynamic water leisure sports like Dragon boat three dimensionally and was thought to be improved for the use efficiency. Third, tourism resources were very important element that affect the use efficiency of waterfront, so waterfront users react sensitively to modern tourism resources rather than to historic resources. This meant that tourism infrastructure for shopping and leisure of the young affected the use efficiency of waterfront, so Hongkong and Busan were in a better position in terms of using waterfront that was near the tourism infrastructure. Fourth, in the analysis of traffic accessibility, both Hongkong and Busan were high evaluated in terms of excellent traffic accessibility by subway. Daejeon was low rated in terms of the satisfaction of use efficiency, because of the relative lower place awareness compared with transportation infrastructure. In Hongkong, waterfront was connected with downtown and in Busan, housing complex and shopping centers were located in the place for users in an easily accessible on foot, so the satisfaction was high-pitched. Finally, in the importance of water surface width and the analysis of satisfaction, except Incheon, all the three were over 200m in width of water surface and this meant the surface width above certain level was interpreted to interrupt the concentration of enjoying the water leisure sports. In the analysis of surface condition such as water quality, water depth and wave, through a survey, Busan had a problem with water quality and Gapcheon in Daejeon had a problem with optimal water depth by the festival participants.