• Title/Summary/Keyword: 적정 위치 선정

Search Result 153, Processing Time 0.031 seconds

DNN Model for Calculation of UV Index at The Location of User Using Solar Object Information and Sunlight Characteristics (태양객체 정보 및 태양광 특성을 이용하여 사용자 위치의 자외선 지수를 산출하는 DNN 모델)

  • Ga, Deog-hyun;Oh, Seung-Taek;Lim, Jae-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.23 no.2
    • /
    • pp.29-35
    • /
    • 2022
  • UV rays have beneficial or harmful effects on the human body depending on the degree of exposure. An accurate UV information is required for proper exposure to UV rays per individual. The UV rays' information is provided by the Korea Meteorological Administration as one component of daily weather information in Korea. However, it does not provide an accurate UVI at the user's location based on the region's Ultraviolet index. Some operate measuring instrument to obtain an accurate UVI, but it would be costly and inconvenient. Studies which assumed the UVI through environmental factors such as solar radiation and amount of cloud have been introduced, but those studies also could not provide service to individual. Therefore, this paper proposes a deep learning model to calculate UVI using solar object information and sunlight characteristics to provide an accurate UVI at individual location. After selecting the factors, which were considered as highly correlated with UVI such as location and size and illuminance of sun and which were obtained through the analysis of sky images and solar characteristics data, a data set for DNN model was constructed. A DNN model that calculates the UVI was finally realized by entering the solar object information and sunlight characteristics extracted through Mask R-CNN. In consideration of the domestic UVI recommendation standards, it was possible to accurately calculate UVI within the range of MAE 0.26 compared to the standard equipment in the performance evaluation for days with UVI above and below 8.

Selection of Appropiate Plant Species of VFS (Vegetative Filter Strip) for Reducing NPS Pollution of Uplands (밭 비점오염저감을 위한 초생대 적정 초종 선정)

  • Choi, Kyung-Sook;Jang, Jeong-Ryeol
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.10
    • /
    • pp.973-983
    • /
    • 2014
  • This study focused on the selection of appropriate plant species of VFS (vegetative fiter strips) and the assessment of VFS effects for reducing NPS (non-point source) pollution from uplands. The experimental field was constructed with 1 control and 6 treated plots in the upland area of $1,500m^2$ with 5% slope which is located in Gunwi-gun, Gyeongbuk province. Six vegetation including Chufa, Common crabgrass, Barnyard grass, Turf grass, Tall fescue, Kenturky bluegrass, were applied to install VFS systems during the study period from June 2011 to Dec. 2012. The results of this study showed that 6.1~77.8% in runoff and 15.6~90.3% in TS, 49.9~96.6% in T-P, and 6.7~91.1% in T-N were reduced from the VFS treated plots. Generally high reduction effects were observed from TS, T-P, T-N, and SS, while BOD, TOC, and $NO_3^-$ showed low reductions. The best vegetation type was Turf grass showing higher reduction effects of NPS pollutions and having relatively easier maintenance efforts compared to other vegetations selected in this study. Based on these results, VFS technique found to be an effective management practice for reducing agricultural NPS pollutions in Korean upland conditions. Further study needs to be performed through various field experiments with long term monitoring in order to develop a design manual of VFS system for practical applications.

A Study on the Selection of AMC of Curve Number (유출곡선지수의 선행토양함수조건 선정 기준 연구)

  • Kim, Jee-Sang;Ahn, Jaehyun
    • Journal of Wetlands Research
    • /
    • v.14 no.4
    • /
    • pp.519-535
    • /
    • 2012
  • In order to establish a rainfall-runoff model, calibration of hydrological parameters for the model is very important. Especially, Curve Number(CN), estimated by NRCS method, is a main factor to apply unit hydrograph theory to calculation of peak discharge. For using NRCS method, it is needed selecting AMC because CN is strongly connected with that. In this study, we focus our concern on finding a applicable standard for selecting AMC for CN. For this, three dams which are Boryeong, Habchon, Namgang are selected as target basins to use observed data including rainfall and dam inflow. As a result of this research, it is found that CN must be included as a calibrated parameter to calculate effective rainfall for the rainfall-runoff model. Also, it is preferred to use PWRMSE of HEC-HMS program as a objective function for optimizing hydrological parameters. From the analyzing result of variation of AMC for peak discharge, it is recommended to apply AMC-III to estimation of CN for calculating effective rainfall of design hydrograph.

A Study on Brace-height Ratio for Seismic Retrofit of School Building (학교 건축물의 내진 보강을 위한 가새 - 높이비에 관한 연구)

  • Lee, Hwa-Jung;Byon, Dae-Kun;Yoon, Sung-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.10-17
    • /
    • 2020
  • The recent earthquake in Korea caused large and small damages to many school building. School building is an important building that is used as a shelter in the event of disaster. Among the seismic retrofit methods, the internal steel braced frame type method is used for its relatively easy construction and excellent performance. In this study, the maximum shear force and displacement were compared and examined by applying the brace frame to existing concrete school buildings. As a result, we verified the adequacy of the analytical model and compared and examined the effect of brace-height ratio on the span of the existing school buildings. The adequacy of the maximum shear force and displacement relationship can be confirmed in the model with a length of 0.3. In addition, seismic frame was applied to the actual non-seismic reinforced concrete school building, and the seismic performance was evaluated by nonlinear static analysis(Push-over analysis) according to the ratio of brace-height. As a result, the increase of the brace-height according to the brace-height ratio has the effect of increasing the maximum shear force and maximum load at the performance point. But the collapse of the braced frame due to the increase in the lateral stiffness occurred, indicating that seismic retrofit according to the proper brace-height is necessary. Therefore, in the seismic retrofit design of brace frame of existing school building, it is necessary to select the proper brace-height after retrofit analysis according to the brace-height ratio.

Influence of Some Commercially Available Mouthwashes on Teeth (일부 시판 구강양치액이 치아에 미치는 영향)

  • Min, Ji-Hyun
    • Journal of dental hygiene science
    • /
    • v.18 no.4
    • /
    • pp.265-270
    • /
    • 2018
  • The purpose of this study was to investigate the chemical properties of some commercially available mouthwashes and to ascertain whether the mouthwashes accelerated mineral loss in dental enamel. Five commercially available mouthwashes were selected from the three largest malls in Korea: Perio Total 7 Aqua Cool Mint Strong $Fresh^{TM}$ (PS; LG Household & Health Care Ltd.), Garglin $Original^{TM}$ (Dong-A Pharmaceutical Co., Ltd.), Garglin $Zero^{TM}$ (Dong-A Pharmaceutical Co., Ltd.), Listerine Naturals $Citrus^{TM}$ (LC; IDS Manufacturing Ltd.), and Listerine Cool $Mint^{TM}$ (LM; IDS Manufacturing Ltd.). The composition, pH, and titratable acidity of the mouthwashes were investigated. Six bovine teeth specimens were prepared for each mouthwash group. Each of the six specimens was individually immersed in 30 ml aliquots of mouthwash for 1 minute, 30 minutes, 90 minutes, and 120 minutes, and the samples were placed in a $36.5^{\circ}C$ stirred incubator. The degree of mineral loss (${\Delta}F$) of the tooth surface area exposed to mouthwash, compared with normal teeth, was analyzed by quantitative light-induced fluorescence-digital. The difference in ${\Delta}F$ among mouthwash groups was examined by the Kruskal-Wallis H test (${\alpha}=0.05$). The contents of mouthwashes differed between Listerine and other products, and the pH ranged from 4.09 to 6.75. The titratable acidity of PS was the lowest at 0.63 ml and highest at 9.25 ml for LM. Minor mineral loss was observed when dental specimens were immersed in the Listerine products (LC and LM) for more than 90 minutes, but the degree of mineral loss for Listerine products was not statistically significantly different from that for groups without mineral loss. In conclusion, all five commercially available mouthwashes showed no harmful effects on tooth enamel.

A Study on Appropriate Tree Species and Crops for Agroforestry Using an Ecological Geographic Map of North Korea (북한의 생태지리구획을 활용한 임농복합경영 적정 수종 및 작물 고찰 연구)

  • Park, Sohee;Lim, Joongbin;Kim, Eun-hee;Yang, A-Ram
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.3
    • /
    • pp.355-368
    • /
    • 2021
  • This study aims to identify appropriate tree species and crops for agroforestry target sites in North Korea based on ecological geography and site properties. To this end, an ecological geographic map (13 regions and 4 zones) of North Korea was made using satellite images and North Korean academic journal articles. The target agroforestry sites were selected and mapped according to 18 site conditions depending on 3 site characteristics, and the sites were divided into short-term and long-term target sites depending on the agroforestry management period. Finally, optimal combinations of 30 tree species and 19 crops were selected by overlapping the ecological geographic map and agroforestry target site map. For regions within the same zone, tree species and crops were almost similar; however, compared to regions in other zones, they differed. This is likely because the geographical climatic characteristics reflected in the ecological geographic map vary greatly from zone to zone. These results will be used to propose a combination of suitable tree species and crops that takes into account both management purposes and management types for inter-Korean forest cooperation in the agroforestry sector.

Evaluating appropriateness of the design methodology for urban sewer system (도시 하수관거 설계 방법의 적정성 평가)

  • Park, Ju-Hyun;Kim, Seon-Ho;Bae, Deg-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.6
    • /
    • pp.411-420
    • /
    • 2019
  • The objective of this study is to evaluate the appropriateness of methodology for designing urban sewer system using a rational method-based model, Makesw and an urban runoff model, SWMM. The Gunja basin was selected as a study area and precipitation, runoff, vegetation, soil, imperviousness data were used to estimate floods. The appropriateness of methodology was evaluated based on comparison analysis between floods estimated from Makesw and SWMM. The comparison analysis was conducted between floods estimated from Makesw and SWMM, which were simulated using design rainfall and measured rainfall from past inundation events. The comparison results showed that in the case of design rainfall, the rational method-based floods were larger than that based on SWMM in all main lines. However in several branch lines, the rational method-based floods were smaller than thoes based on SWMM. In addition, for the case of measured rainfall from past inundation events, it was easily to find the main and branch lines where the rational method-based floods were smaller than SWMM based ones. Especially, the lines where rational method-based floods were underestimated, were mostly main, $1^{st}$, $2^{nd}$ lines. It was concluded that the rational method-based results were not conservative. Based on rational method (steady flow analysis) and SWMM (unsteady flow analysis), the more conservative results the method provides, the more highly it is recommended to use in designing an urban sewer system.

A Study on Optimum Tree Planting Density for Apartment Complex (아파트단지 조경수 적정식재밀도 연구)

  • Oh, Choong-Hyeon;Jeong, Wook-Ju;Lee, Im-Kyu;Kim, Min-Kyung;Park, Eun-Ha
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.140-147
    • /
    • 2012
  • This study was conducted to investigate optimum planting density for apartment complex. The validity of Landscape Architecture Criteria of Korea was checked for it. We compared our field data with Landscape Architecture Criteria. In this step, the tree density of urban forest was regarded as standard. Field study was examined in 3 apartment complexes located in capital area, especially completed during these 10 years. 10 sites in each complex were selected and tree density per unit area were calculated. This field study data was divided standard size and large size which received weight. And, it was compared and analyzed. And crown projected area(CPA) was calculated considering proper growth of low vegetation and sufficient shade. The outcome shows that minimum size of Landscape Architecture Criteria is rational. But, in the case of planting large size tree received weight, tree density was short comparing with the tree density of urban forest and CPA was less than 50%. By the result of field study in 3 apartment complex, the tree density of apartment complex satisfied or exceeded Landscape Architecture Criteria. But, in the case of planting large size tree, tree density and CPA show high density due to addition planting for deficient landscape. Therefore, the revision of the Landscape Architecture Criteria was required such as deletion or minimization of the weighted clause about the large size tree and regulate the limit CPA not less than 50% and not more than 100%.

Evaluation of Biological Aerated Filter Position on Water Treatment Processes for Water Quality Improvement (상수원수 전처리 시 효율향상을 위한 생물여과 반응기 위치선정)

  • Choi, Hyung-Joo;Choi, Dong-Ho;Bae, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.677-686
    • /
    • 2006
  • This study was the effectiveness of two downflow BAF(Biological Aerated Filter) systems at conventional water treatment system. A BAF reactor placed in front of coagulation and sedimentation tanks(Mode A) and after coagulation and sedimentation tanks(Mode B) that were compared in terms of removal of suspended particles, organic matters, and ammonia nitrogen. The suspended particles removal efficiency was over 80% for both Mode A and B, although Mode A gave slightly better results. $BOD_5$ removal and nitrification efficiencies were more than 90% for both reactor. The organic matter and ammonia removals were also superior in the Mode A. The biofilm thickness and biomass increased as increment of EBCT and the upper part of reactor more about 30% than lower part. The specific oxygen uptake rate(SOUR) was higher the upper part of reactor and Mode A than the lower part of reactor and Mode B. A cost analysis showed that the Mode A system was more cost effectiveness. It could save the coagulant dose by about 67% and the chlorine demand by about 95%. The ideal place to put the BAF reactor was in front of the coagulation/sedimentation process.

A Study on the Basic Characteristics of In-situ Soil Flushing Using Surfactant (계면활성제를 이용한 원위치 토양세정 기법 적용을 위한 기초 특성 연구)

  • 최상일;소정현;조장환
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.87-91
    • /
    • 2002
  • Lab scale batch and column tests were performed to investigate the treatability of petroleum contaminated soil using the in-situ soil flushing method. The pyrex column (4.5$\times$25 cm) was used to investigate optimal washing agent, surfactant concentration, mixing ratio, and inlet velocity. The miked surfactant of $POE_{14}$ and SDS were determined as ideal systems for the batch tests. From the results of preliminary tests, mixed surfactant was found to be more harmful for microorganisms. So $POE_{5}$ and $POE_{14}$ were chosen as the surfactant system for the batch study. The washing efficiency for the diesel contaminated soil was increased until 1 %, and decreased after l %. When applied as selected mixed surfactant, the ideal mixed ratio was recognized as 1:1. Therefore we selected miked surfactant $POE_{5}$ and $POE_{14}$, surfactant concentration 1%, and mixed ratio 1:1 for the remediation of diesel contaminated soil. In column tests, the total removal efficiency was improved as the flux of washing agent was increased. At the same pore volume, small flux showed better removal efficiency.