• Title/Summary/Keyword: 적정 시용량

Search Result 199, Processing Time 0.028 seconds

The Profitability Analysis of BESS Installation with PV Generation under RPS (RPS 제도 하에서의 태양광발전 연계형 배터리시스템 수익분석 방법에 관한 연구)

  • Kim, Chang-Soo;Yoo, Tae-Hyun;Rhee, Chang-Ho
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.107-117
    • /
    • 2017
  • Since South Korea started to apply Renewable Portfolio Standard (RPS) in 2012, there have been huge investment for deploying renewable technologies. Recently, the government determined to incentivize battery energy storage system(BESS) with renewable generations in order to induce the improvement of dispatching capability. In this paper, the annual pattern of PV generation based on actual generation data in South Korea is analyzed and the duration curve of capacity factor is proposed in order to provide the simplified analyzing methodology of present support policy for additional BESS installation for decision maker who is responsible for supply and demand planning. With suggested methodology, the range of appropriate BESS size with respect to the variation of system marginal price(SMP) and renewable energy certificate(REC) price can be derived briefly, and decision makers easily evaluate the effect of support scheme. Current policy for BESS installation support present additional BESS-related installation policy may give incentives to developers partially, however, the dependence between BESS size and benefit components (SMP and REC) can limit the deployment of the various portfolios of the BESS. Therefore, when improving the current policy in future, addressing the dependence between the technical aspects of battery size and the benefit components separately by the technical and economical parts is needed to set the suitable compensation rules for the renewable generation and BESS.

The Influence of Inductive Loads on the Power System Voltage (유도부하가 전력계통 부하모선의 전압에 미치는 영향)

  • 조양행;정재길
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.1
    • /
    • pp.37-46
    • /
    • 1995
  • Along with the recent trend of complexity and long distance transmission in power system, dynamic analysis of stability considering the load characteristics is an important subject. In this paper, the influence of the induction motor loads on the power system voltage is investigated. The influence of the inductive load ratio and the inertia of induction motor on the voltage response of the power system are examined, and in the case of the high percentage of the induction motor load, induction motors in the power system can lead to transient voltage instability even under the system condition such as switching operation. The application of static condenser(SC) to prevent the transient voltage instability is introduced.

  • PDF

A Study on the Battery Storage Volume Optimization in case of DR Participation for the Minimization of the Customer's Investment Cost (BESS의 DR(Demand Response) 적용 시 수용가의 투자비 최소화를 위한 적정용량산출방법)

  • Yang, Seung-Kwon;Kim, Dae-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.17-23
    • /
    • 2013
  • The BESS(Battery Energy Storage System) is an useful device for load leveling, but the high cost, installation space and safety issues are the main barriers for supplying it widely. The important factor in supplying BESS to customers successfully is the payback period. As most of the H/W cost factors are uncontrollable, the optimization of storage volume can be useful factor in improving payback period. In order to obtain optimized BESS volume, the load factor, demand ratio, peak shaving ratio, electric rates and benefits from DR participation of customer should be analyzed. In this paper, we could verify the peak cutting capability and cost effectiveness under the some proposed conditions and changing value of PCS and battery based on the customers data after volume optimization process was applied, and we can identified the saturation point of load factor and shortening of customer's payback period.

기획특집 - T.A.B. 수행절차 및 수행 계획

  • An, Jeong-Ho
    • 월간 기계설비
    • /
    • s.232
    • /
    • pp.50-70
    • /
    • 2009
  • T.A.B란 공기조화설비에 대한 종합시험조정으로 시험, 조정 및 균형(Testing, Adjusting & Balancing)이라는 뜻이다. 이는 설계 목적에 부합되도록 모든 빌딩의 환경시스템을 검토하고, 조정하는 과정이다. 따라서 T.A.B기술은 공기 및 물이라는 유체의 흐름과 온 습도에 관련된 분야이기 때문에 시각적으로 그 성과를 알아보기 힘들고, T.A.B를 적용한 후 결과치를 정밀 분석해 판단할 수 있으며 T.A.B기술을 적용하지 않은 건물과 간접비교하는 방법으로 그 효과를 쉽게 알 수 있다. T.A.B기술을 적용할 경우 시공 중인 건물에 설계도서가 완료되기 전, 또는 장비의 구매발주 전에 T.A.B측면에서 모든 기술 도서를 면밀히 검토하게 된다. 그 중 일부에서 발견되는 문제점들 즉, 적정치 못한 용량 선정, 시스템 구성상 미비점, 불필요한 장비 선정, 누락 사항을 발견할 수 있다. 따라서 T.A.B 기술을 적용할 경우 향상된 품질의 시공이 가능해 준공 후 빈번히 대두되는 하자 문제가 현격히 줄게 되며 또한 운전경비 절감, 쾌적한 실내환경 조성, 장비수명 연장 등 효율적인 운전관리 효과를 얻을 수 있다. 우리나라 공기조화설비기술은 꾸준한 발전을 이루었고, 최근에는 도입 초기단계시 전혀 고려되지 않던 공조공간의 쾌적성 및 소음 방지 대책 등의 문제가 주요사항으로 부각되고 있다. 이에 따라 공조설비에 T.A.B실행의 표준화 정착과정에 있으며, 국내 학계 및 연구기관에서 공조설비에 대한 연구 및 T.A.B용역업체의 기술축적 등 T.A.B분야 발전을 위해 노력하고 있다. 본지는 T.A.B의 수행절차 및 수행계획, TAB 수행업체 등에 대해 알아본다.

  • PDF

A Study on the Design of Evacuation Route at Subway Station Using Simulation Analysis (Simulation 분석을 통한 지하철 역사 피난동선 설계 방안에 관한 연구)

  • Ham, Eun-Gu;Roh, Sam-Kew
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.1-7
    • /
    • 2010
  • Since subway fire disaster at Daegu, Korea smoke control system and passengers evacuation distance has been focused to reform. Existing smoke control facilities need to expand volume of ventilation capacity however, the complicate subway station structure can hardly react dispersion of smokes from massive subway cabin fire. Smoke flow at platform level move upward thought vertical stairway and passengers evacuation goes with same direction. The victims of evacuees from subway station fire mainly due to exposure of heat radiation and smoke. The study demonstration the effect of downward evacuates stairway system by separating evacuation route to smoke movement pass way including saving times of evacuation.

A Study on the Frequency Control for Cheju HVDC linked System (제주 HVDC 연게 시스템의 주파수 제어에 관한 연구)

  • Park, Jong-Kwang;Choi, Jong-Kee;Jin, Seong-Eun;Kim, Chan-Ki;Han, Byung-Sung;Kim, Kyung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.145-151
    • /
    • 2005
  • Cheju-Haenam HVDC link transmits electrical power up to 300[MW] Because of its size, HVDC system has a great potential for damping power system oscillations. This paper with the frequency control of the KEPCO HVDC system linking Haenam to Cheju island. Frequency control at Cheju island ensures that the island AC system frequency is maintained Performance are evaluated using a reduced Cheju network and a detailed model of the fm system modelled in the PST software. Transient oscillations for the 3 phase fault carried out with HVDC frequency control are well damped as the control parameters have been adjusted.

Development and application of the hypothetic sewer network generation technique for urban inundation simulation (도시침수 모의를 위한 가상관망 생성 기술 개발 및 적용성 평가)

  • Seung Soo Lee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.340-340
    • /
    • 2023
  • 최근 전 세계가 극단적 집중호우로 인한 대규모 홍수로 인해 극심한 몸살을 앓고 있다. 특히, 설계빈도를 초과하는 강우로 인해 도시지역에서 발생하는 도시침수는 그 특성상 막대한 인명과 재산상의 피해를 유발하므로 이를 사전에 예방하고 피해를 줄이기 위한 노력이 매우 시급한 실정이다. 도시유역 침수 해석을 위한 수치모의는 대상 유역의 현재 대비 상황을 판단할 수 있을 뿐만 아니라 하수관로 증설 효과 파악, 빗물저류조의 침수저감 효과 분석, 빗물배수펌프장의 적정용량 파악 등에 매우 효율적이다. 정확도 높은 도시침수 해석을 위해서는 고해상도 DEM 또는 DSM 지형자료뿐만 아니라 토지이용도 및 지하에 매설되어 있는 하수관망(하수관로, 맨홀, 배수펌프장 등) 자료의 활용이 필수적이다. 그러나 저개발 국가나 미계측유역의 경우에는 신뢰도 높은 하수관망 자료를 얻기가 매우 어려울 뿐만 아니라 해당 자료가 존재하지 않는 경우도 빈번해 도시침수 해석이 곤란한 경우가 다수 발생한다. 따라서 본 연구에서는 GIS 형태로 제공되는 Open Street Map(OSM)의 도로망 정보를 이용해 가상의 하수관망을 생성하는 방법론을 제시하고 서울시 사당유역을 미계측유역으로 가정해 가상의 하수관망을 생성해 그 적용성을 평가하였다. 본 연구에서 제시된 결과는 하수관망 자료의 획득이 곤란한 지역의 도시침수 예측이나 효과적인 하수관망 설계에 활용될 수 있을 것으로 판단된다.

  • PDF

A Study on data pre-processing for rainfall estimation from CCTV videos (CCTV 영상 기반 강수량 산정을 위한 데이터 전처리 방안 연구)

  • Byun, Jongyun;Jun, Changhyun;Lee, Jinwook;Kim, Hyeonjun;Cha, Hoyoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.167-167
    • /
    • 2022
  • 최근 빅데이터에 관련된 연구에 있어 데이터의 품질관리에 대한 논의가 꾸준히 이뤄져 오고 있다. 특히 이미지 처리 및 분석에 활용되어온 딥러닝 기술의 경우, 분류 작업 및 패턴인식 등으로부터 데이터의 특징을 추출함으로써 비지도학습(Unsupervised Learning)을 가능하게 한다는 장점이 있음에도 불구하고 빅데이터를 다루는 과정에 있어 용량, 다양성, 속도 및 신뢰성 측면에서의 한계가 있었다. 본 연구에서는 CCTV 영상을 활용한 강수량 산정 모델 개발에 있어 예측 정확도 향상 및 성능 개선을 도모할 수 있는 데이터 전처리 방법을 제안하였다. 서울 근린 AWS 4개소 지역(김포장기, 하남덕풍, 강동, 성남) 및 중앙대학교 지점 내 CCTV를 설치한 후, 최대 9개월의 영상을 확보하여 강수량 산정을 위한 딥러닝 모델을 개발하였다. 배경분리, 조도조정, 영역설정, 데이터증진, 이상데이터 분류 등이 가능한 알고리즘을 개발함으로써 데이터셋 자체에 대한 전처리 작업을 수행한 후, 이에 대한 결과를 기존 관측자료와 비교·분석하였다. 본 연구에서 제안한 전처리 방법들을 적용한 결과, 강수량 산정 모델의 예측 정확도를 평가하는 지표로 선정한 평균 제곱근 편차(Root Mean Square Error; RMSE)가 약 30% 감소함을 확인하였다. 본 연구의 결과로부터 CCTV 영상 데이터를 활용한 강수량 산정의 가능성을 확인할 수 있었으며 특히, 딥러닝 모델 개발시 필요한 적정 전처리 방법들에 대한 기준을 제시할 수 있을 것으로 판단된다.

  • PDF

A Study on the Installation of Rupture Disk for Emergency Discharge of Dangerous Substances in Case of Styrene Monomer Runaway Reaction (스티렌모노머 폭주반응 시 위험물 비상 배출을 위한 파열판 적정 크기 선정에 관한 연구)

  • Sang Ryung Kim;Jae Min Ryu;Hyang Nam Choi;Jong Su Hyun;Hyung Sik Byun
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.2
    • /
    • pp.24-31
    • /
    • 2024
  • In the chemical industry, fires and explosions constantly occur due to runaway reactions during the production of various chemical products. To prevent this, much research has been conducted, and the possibility of runaway reactions for each substance is reviewed and interlocking devices are installed to prepare for adverse reactions to prepare for fires and explosions. However, despite legal and technical safety measures, accidents due to runaway reactions still occur every year. Accordingly, in this study, based on cases of fire and explosion accidents in styrene monomer reactors, the discharge capacity during runaway reactions was examined through experiments and graphs. Unlike the commonly calculated fire equation, in the case of a runaway reaction where pressure and temperature increase rapidly, discharge is made in two phases rather than a single phase, so the size of the rupture disk must also increase, and the orientation must be adjusted before the rupture disk is installed at the top of the pressure vessel. It was found that position adjustment was necessary.

Effect of the Slow-releasing Fertilizer Applied Directly to Rice Seedling Tray Before Transplanting and Practical Test at Field (이앙직전 벼 육묘상자 살포용 완효성 비료의 처리 효과)

  • Chi, Jeong-Hyun;Choi, Byoung-Rourl;Jo, Gwang-Lae;Kim, Soon-Jae;Park, Kyeong-Yeol;Kwon, O-Youn
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.58 no.1
    • /
    • pp.8-14
    • /
    • 2013
  • The newly developed fertilizer is the slow-releasing fertilizer which can be used as a basal fertilizer without no additional fertilization at tillering stage. It has 30-4-6% of $N-P_2O_5-K_2O$ and was coated with mixture of LDPE (Low density polyethylene), EVA (Ethylene vinyl acetate), BDP (Bio degraded polymer), TALC and nonionic surfactant for the controlled release up to 50 days after application. Coating materials were designed to be decomposed naturally. This fertilizer can be applied directly to the seedling tray mechanically just before transplanting, resulting in significant labor saving effect. The developed slow-release fertilizer, which can replace both basal fertilization and top dressing at tillering stage by single application directly to seedling tray, showed the highest release at 14~21 days after transplanting. Considering the plant growth at different growth stages and yield, the optimal application rate of developed slow-release fertilizer was 300 g per rice nursery tray and the yield of rice at this application rate was 5.25 MT/ha. Rice quality in terms of head rice grain ratio, amylose content, whiteness, and taste value decreased as fertilization rate increased from 200 g to 500 g per nursery tray. Fertilization rate based on quantity of fertilizer ingredients (N, P, K) was reduced by 49.3% compared to the standard application rate and there was 49.2% reduction in labor input for fertilization.