• Title/Summary/Keyword: 적외선 분광분석

Search Result 468, Processing Time 0.039 seconds

Analysis of Spectral Response Specification for the Infrared Channels of Meteorological Imager (기상 영상기의 적외선 채널 분광 응답 규격에 대한 분석)

  • Cho, Young-Min
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.104-110
    • /
    • 2007
  • Analyzed is the spectral response profile specification used for the infrared (IR) channels of the meteorological imagers of GOES series geostationary satellites. The variation characteristics of effective wavelength and effective input radiance due to the change of the spectral response function profile within the imager performance specification are analyzed in order to propose how to understand the spectral response specification. As an analysis approach, at first a center symmetrical spectral response function and 4 worst case spectral response functions are selected within the spectral response specification, and then effective wavelength and effective input radiance are calculated for each spectral response function. As a result, the maximum allowable ranges of effective wavelength and effective input radiance are provided per the spectral response specification.

  • PDF

푸리에 변환 적외선 분광분석에 의한 에피층의 두께 측정 기술

  • Jeong, Seong-Hwa;Kim, Sang-Gi;Kwon, Oh-Joon
    • ETRI Journal
    • /
    • v.13 no.2
    • /
    • pp.54-61
    • /
    • 1991
  • 에피택시층의 두께는 푸리에변환적외선분광분석(FTIR)을 이용하여 간단하고 비파괴적으로 측정할 수 있음이 알려져 있다. 본고에서는 측정법의 기본적인 배경을 살펴보고 실제 시편의 측정결과를 제시하며 본 두께 측정법의 적용 가능성 및 문제점에 대해 논의한다.

  • PDF

Analysis on Sequence of document processing by using Digital Infrared Photography (적외선 사진을 이용한 문서작성 순서에 관한 분석)

  • Kim, Yoo-jin
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.447-448
    • /
    • 2011
  • 오래전부터 적외선은 문서감정 분야에서 사용했으나, 대부분 필기구의 분광반사 차이를 이용한 문서의 위변조에 집중되었을 뿐, 문서를 작성한 필기구들의 사용 순서에 대한 분석에는 이용하지 않았다. 문서작성의 순서를 분석하기 위해서는 보통 현미경으로 필적을 확대하여 분석하지만, 상황에 따라 분명치 않은 경우도 있다. 따라서 본 연구에서는 필기구들의 분광반사 차이를 이용하여 필기구들이 겹친 영역을 분석함으로서 문서작성에 사용한 필기구들의 사용 순서를 쉽게 판단할 수 있는 방법을 제안하고 있다. 이 방법은 필기구 사용 순서에 따라 법적인 해석에 대한 논쟁이 있을 수 있는 보험계약서 등에 적용이 가능할 것으로 기대한다.

  • PDF

Development of On-line Quantitative Analysis for Bioethanol Using Infrared Spectroscopy (적외선 분광분석을 이용한 바이오 에탄올 on-line용 정량분석법 개발)

  • Kim, Hyeonguk;Ryu, Jun-Hyung;Liu, J. Jay
    • Applied Chemistry for Engineering
    • /
    • v.23 no.1
    • /
    • pp.35-41
    • /
    • 2012
  • This paper proposes a new methodology for the real-time on-line quality monitoring of biofuel processes through the integration of infrared spectroscopy and chemometrics. A method of Partial Least Squares (PLS) in Chemometrics is employed for quantitative analysis of key components in bioethanol products. After a number of preprocessing methods and variable importance in projection (VIP) are used, Savitzky-Golay method showed the best performance in terms of spectrum correction, noise reduction, and model maintenance. The proposed method allows us to economically forecast the concentration of multiple impurities encountered with the production of bioethanol. The proposed system is also accurate enough ($R^2$ > 0.99) to replace the laboratory analysis.

Analysis of biodiesel quality based on infrared spectroscopy and multivariate statistics (적외선 분광분석과 다변량 통계에 기반한 바이오디젤 품질분석)

  • Kim, Hye-Sil;Cho, Hyun-Woo;Liu, J. Jay
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.214-222
    • /
    • 2012
  • ASTM (American Society for Testing and Materials) D6751-10 suggests analytical methods as well as specifications for biodiesel quality. However, it is expensive and time-consuming to follow the ASTM testing methods to analyze biodiesel and various impurities. This paper develops a quantitative analysis system for biodiesel and impurities based on Infrared spectroscopy and a multivariate statistical method, PLS (partial least squares). In addition, four different pre-processing techniques were compared for spectrum correction and noise reduction. Savitzky-Golay pre-processing showed the best performance.

Spectroscopic Characteristics of Tourmalines from Antandrokomby, Madagascar (마다가스카르 Antandrokomby 지역 투어말린의 분광학적 특성)

  • Lee, Sung;Ahn, Yong-Kil;Seo, Jin-Gyo;Park, Jong-Wan
    • Journal of the Mineralogical Society of Korea
    • /
    • v.22 no.4
    • /
    • pp.385-393
    • /
    • 2009
  • The spectroscopic characteristics of Madagascar tourmaline were investigated by UV-Vis and FTIR spectroscopy. Physical features were similar to other region's tourmalines. The green and blue samples showed strong absorption band in the 714~743 nm due to $Fe^{3+}$, pink samples showed strong absorption band in the 510~530 nm due to $Mn^{3+}$, brown samples showed strong absorption at 324 nm due to $Mn^{2+}-Ti^{4+}$ IVCT and the colorless samples only revealed weak absorption at 406~413 nm or no absorptions due to low quantity of Mn. Combination of the stretching and bending mode cationic hydroxyl units (metal-OH) are observed in the 4300~4500 $cm^{-1}$. The parallel tube-shaped inclusions which contain hematite were detected generally. This investigation revealed that Cu was not detected but Fe and Mn were detected in the Madagascar tourmalines, and the various colors appear according to the amount of those impurity elements.