• Title/Summary/Keyword: 적외선분광

Search Result 636, Processing Time 0.05 seconds

The analysis of the Effect the Minute Quantities of Infrared Rays that Were not Filtered by IR Cut-Off Filter has on Digital Images (IR Cut-Off Filter가 차단하지 못한 미량의 적외선이 디지털화상에 미치는 영향 분석)

  • Lee, Yong-Hwan;Park, Se-Won;Hong, Jung-Eui
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.205-215
    • /
    • 2011
  • Films are sensitive to ultraviolet rays and in contrast, digital camera sensors are extremely sensitive to infrared rays due to the differences in spectral characteristics. As a result, all digital cameras that use CCD or CMOS are equipped with IR Cut-Off Filter on the overall sensor. Complete block out of infrared rays is ideal, but the actual experiment results showed that infrared rays were not being blocked out completely. Infrared permeability was also different for each camera. Therefore, this study aims to analyze the effect of the minute quantities of infrared rays, which get transmitted due to mechanical properties of IR Cut-Off Filters that are installed on digital cameras, on digital picture images. The results obtained by carrying out a comparative analysis of a UV Filter (infrared transmitting state) and a UV-IR Filter (infrared blocked out state) are as follows. It was confirmed that the minute quantities of infrared rays do affect dynamic range and resolution to some extent, despite the little or no difference in noise and color reproduction.

Case Study on Solar System Objects using Mid-IR Spectrometer

  • Seo, Haingja;Kim, Eojin;Kim, Joo Hyeon;Lee, Joo Hee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.97.1-97.1
    • /
    • 2013
  • 적외선 분광 관측은 상대적으로 온도가 낮은 태양계 천체를 연구하는데 있어서 매우 강력한 관측 기술이다. 특히 근적외선 및 중적외선 분광선은 태양계 천체의 지표 및 대기의 성질에 대해서 많은 정보를 주는 파장대이다. 따라서 우주탐사선 뿐만 아니라 지상 망원경으로도 근적외선 및 중적외선 영역의 분광관측은 지속적으로 관측이 수행되고 있는 영역이다. 이렇게 획득된 분광선은 모델링의 과정을 통하여 천체의 구성성분, 생성 과정 및 생성 시기, 물리, 화학적 진화 등을 연구할 수 있다. 본 연구에서 개발 중인 3~5 micron 중적외선 분광기 지상모델은 향후 태양계 천체들에서 물 또는 얼음을 찾을 수 있는 가능성이 있는 파장대이며, 또한 국내에서 개발된 적이 없는 파장대이다. 본 연구에서는 우주탐사선에 탑재된 중적외선 분광기에 의해 관측된 지표를 가진 태양계 천체 (수성, 금성, 화성, 타이탄, 혜성, 소행성)들의 연구 사례를 조사하였다. 이 자료는 본 연구에서 개발하고자 하는 중적외선 분광기 지상모델의 완성 단계에서 지표를 가진 태양계 천체, 특히 달에 대한 과학적 임무를 결정하는데 중요한 역할을 할 것으로 기대하고 있다.

  • PDF

ATR 분광계를 이용한 화학증착소재 흡착에 따른 표면거동에 대한 연구

  • Park, Myeong-Su;Kim, Yeong-Gyu;Sin, Jae-Su;Lee, Chang-Hui;Yun, Ju-Yeong;Gang, Sang-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.120.2-120.2
    • /
    • 2013
  • 반도체 소자의 소형화로 신개념 화학증착공정 구현을 위한 장비와 화학증착소재의 개발이 활발이 연구되고 있다. 특히 증착소재의 물리적 화학적 특성을 파악하고 가장 적합한 소재를 선택하기 위한 연구도 변행되고 있다. 많은 연구자들이 소재 평가를 위해 가스크로마토그래피, 질량분석기, 적외선 분광기 등을 이용한 화학증착소재의 특성을 파악하기 위해 노력하고 있다. 하지만 실제 화학기상증착(Chemical Vapor Deposition)법과 원자층증착(Atomic Layer Deposition)법 공정에서 웨이퍼 표면에서의 화학증착소재의 흡착거동에 대한 연구는 거의 전무한 실정이다. 따라서 본 연구에서는 개선된 Attenuated Total Reflectance(ATR)분광계를 이용하여 표면에 흡착된 소재의 흡착거동에 대해 분석을 수행하였다. 평가에 사용된 화학증착소재는 C-Zr (Tris (dimethylamino) cyclopentadienyl zirconium)이며, Fourier Transform Infrared Spectroscopy (FT- IR)시스템 내에 설치된 ATR 분광계 표면에 흡착된 C-Zr 증착소재를 다양한 공정조건(온도 및 반응가스, 플라즈마 파워 등)에서의 거동 변화를 연구하였다.

  • PDF

Measurement and Validation of Infrared Signature from Exhaust Plume of a Micro-Turbo Engine (마이크로 터보 엔진 배기 플룸에서의 적외선 신호 측정 및 검증)

  • Gu, Bonchan;Baek, Seung Wook;Jegal, Hyunwook;Choi, Seongman;Kim, Won Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1054-1061
    • /
    • 2016
  • Development of an accurate infrared signature (IR) measurement system is expected to contribute in the development of low observable technology and the spectroscopic analysis of electromagnetic radiation. Application of a spectroradiometer (SR) allows for the measurement of detailed infrared signature from the exhaust plume due to its own heat source. Establishment of a measurement system using a micro-turbo engine is intended to simulate the modelling of the aircraft plume. The engine was installed on a test stand to measure the engine performance. The IR signature was measured by placing the SR perpendicular to the axis line of the exhaust plume. Reference data from the blackbody were also measured to calibrate the raw data, and the infrared signature of the background was also measured for comparison with that of the plume. The calibrated spectral radiance was obtained through the data reduction process and the results were analyzed in specific bands. The experiments revealed that the measurement system established here showed sufficient performance for further comprehensive analysis.

Infrared Spectroscopic Studies on Dickite and Pyrophyllite: Far-IR and Mid-IR Regions (딕카이트와 엽납석에 대한 적외선 분광학적 연구: 원적외선 및 중간적외선 영역)

  • 추창오;김수진
    • Journal of the Mineralogical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.119-127
    • /
    • 2001
  • FTIR spectroscopic study was undertaken on dickite and pyrophyllite with Si and Al cations in the far-infrared(Far-IR) and mid-infrared (Mid-IR) regions, respectively. Attempts were made to present bonding information and make assignments on the absorption bands of dickite in the Far-IR region. Dickites contain a small proportions or kaolinite or nacrite layers. FTIR can be used as a potential tool for characterizing the presence of mixed-layer with different polytypes of the kaolin minerals. There is no clear relationship between Hinckley index and crystallinity of dickite. Although pyrophyllite shows a strong OH stretching band at 3673-3676 $cm^{-1}$ / corresponding to an inner hydroxyl group, the weak band at $3645-3648 cm^{-1}$ seems to be due to the symmetric vibration if the symmetry of the structure is not ideal, probably due to the presence of trace Fe or mixture phases of 1Tc and 2M polytypes.

  • PDF

Spectroscopic Characteristics of Ruby from Gorno-Badakhshan, Tajikistan (타지키스탄 고르노바다흐샨주 지역 루비에 대한 분광학적 특성 연구)

  • Chung, Sol Lim;Park, Jong Wan
    • The Journal of the Petrological Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Physical properties, XRF, UV-Vis, FTIR studies were carried out in order to characterize gemological features of ruby from Tajikistan. Fluorescence reaction of the Tajikistan ruby to short wave ultraviolet was moderate to very strong in red and long wave ultraviolet rays was weakly detected. UV-visible analysis strong absorption bands at 468.5, 475, 476.5 nm and broaden bands at 550 nm were observed for ruby due to $Cr^{3+}$. According to FT-IR analysis, all rubies from Tajikistan showed the similar patterns and kaolinite peaks at 3500, 3617, 3630, $3677cm^{-1}$ and boehmite broaden absorption bands at 3085 and $3320cm^{-1}$. Inclusions in Tajikistan ruby are observed solid inclusions, negative crystals, needle and silk inclusions. These distinctive characteristics mentioned above can be used to identify the locality and source of ruby stones from Tajikistan.

Preparation and Characterization of Polyurethane Microcapsules Containing Functional Oil (기능성 오일을 함유하는 폴리우레탄 마이크로캡슐의 제조 및 분석)

  • 김인회;서재범;김영준
    • Polymer(Korea)
    • /
    • v.26 no.3
    • /
    • pp.400-409
    • /
    • 2002
  • Polyurethane microcapsules containing functional oil (citronella oil) were successfully prepared by conventional interfacial polymerization of tolulene 2,4-diisocyanate (TDI) and ethylene glycol (EG) and characterized by Fourier transform (FT-IR) spectroscopy, Ultraviolet spectroscopy, particle size analysis, thermogravimetric analysis (TGA), and scanning electron microscopy (SEM). Tile effects of polymerization variables, such as surfactant concentration and agitation speed, on the particle size and particle size distribution were investigated. FT-IR spectroscopic data showed that citronella oil was successfully encapsulated in the microcapsule. Thermogravimetric analysis data showed that the microcapsule was thermally stable up to $220^{\circ}C$. The controlled release of the citronella oil present in the microcapsule core in a methanol medium was demonstrated by ultraviolet spectroscopy showing that the amount of released citronella oil was increased with increasing time. It was observed that the amount of released citronella oil was increased with increasing stirring speed and emulsifier concentration in the rnicrocapsule preparation step. Polyurethane microcapsules containing citronella oil showed excellent anti-moth property.

Image Fusion Framework for Enhancing Spatial Resolution of Satellite Image using Structure-Texture Decomposition (구조-텍스처 분할을 이용한 위성영상 융합 프레임워크)

  • Yoo, Daehoon
    • Journal of the Korea Computer Graphics Society
    • /
    • v.25 no.3
    • /
    • pp.21-29
    • /
    • 2019
  • This paper proposes a novel framework for image fusion of satellite imagery to enhance spatial resolution of the image via structure-texture decomposition. The resolution of the satellite imagery depends on the sensors, for example, panchromatic images have high spatial resolution but only a single gray band whereas multi-spectral images have low spatial resolution but multiple bands. To enhance the spatial resolution of low-resolution images, such as multi-spectral or infrared images, the proposed framework combines the structures from the low-resolution image and the textures from the high-resolution image. To improve the spatial quality of structural edges, the structure image from the low-resolution image is guided filtered with the structure image from the high-resolution image as the guidance image. The combination step is performed by pixel-wise addition of the filtered structure image and the texture image. Quantitative and qualitative evaluation demonstrate the proposed method preserves spectral and spatial fidelity of input images.

Development of Spectral Irradiance Measurement System (분광복사조도 측정 장치 개발)

  • Seo, Jung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.48-53
    • /
    • 2004
  • Spectral irradiance measurement system was developed to measure the spectral irradiance of optical sources in the wavelength range from 250[nm] to 1600[nm]. Our system is composed of source system, fore-optics, monochromator system, optical detector system, and automatic control system. Optical detector system with PMT, Si, InGaAs, and IR enhanced InGaAs detectors is used to measure the wide spectrum of optical sources in ultraviolet visible, and infrared wavelength regions. Spectral irradiance of the 1[kW] quartz-halogen tungsten lamp was measured and compared in the wavelength range from 250[nm] to 1600[nm]. The differences between our results and those reported by NIST are below 3[%], 3.5[%], and 5[%] in the wavelength range of 450∼700[nm], 700∼1600[nm], 250∼400[nm], respectively.

GMT용 적외선 광대역 고분산 분광기 GMTNIRS 개발

  • Yuk, In-Su;Lee, Seong-Ho;Cheon, Mu-Yeong;Park, Gwi-Jong;Park, Chan;Park, Su-Jong;Gwon, Jeong-Mi;O, Hui-Yeong;Kim, Sang-Hyeok;Seo, Haeng-Ja;Park, Byeong-Gon;Kim, Yeong-Su;Jaffe, Daniel T.;Lee, Han-Sin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.34 no.2
    • /
    • pp.24.1-24.1
    • /
    • 2009
  • PDF