• Title/Summary/Keyword: 적외선가열

Search Result 74, Processing Time 0.023 seconds

Non-destructive Inspection of Construction Joints of Concrete Structures Using the Radar and the Infrared Thermography Method (레이더법과 적외선법을 이용한 콘크리트 시공 이음부 공극의 비파괴검사)

  • Park, Seok-Kyun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.425-432
    • /
    • 2003
  • The joint treatment of concrete is one of the technical problems in concrete constructions. Joints created with concrete constructions result in serious weakness in the aspects of both structural and water-barrier function. The radar and the infrared thermography method have been used for the non-destructive inspection of several construction joints of concrete structures in this study. The advantages and limitations of these methods are investigated for non-destructive inspection on construction joints of concrete columns. It can be shown that the detecting precision of construction joints using these methods is improved if radar analysis is carried out with a simulation analysis. In case of the infrared thermography method, the shape of construction joints can be also detected when heating is performed before testing. As the result, it has been verified that the construction joints, difficult to be detected by visual inspection, could be inspected effectively in broad areas at short period of time when these two methods are applied.

백색 LED증착용 MOCVD 유도가열 장치에서 가스 inlet위치에 따른 기판의 온도 균일도 측정

  • Hong, Gwang-Gi;Yang, Won-Gyun;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.115-115
    • /
    • 2010
  • 고휘도 고효율 백색 LED (lighting emitting diode)가 차세대 조명광원으로 급부상하고 있다. 백색 LED를 생산하기 위한 공정에서 MOCVD (유기금속화학증착)장비를 이용한 에피웨이퍼공정은 에피층과 기판의 격자상수 차이와 열팽창계수차이로 인하여 생성되는 에피결함의 문제로 기판과 GaN 박막층 사이에 완충작용을 해줄 수 있는 버퍼층 (Buffer layer)을 만든다. 그 위에 InGaN/GaN MQW (Multi Quantum Well)공정을 하여 고휘도 고효율 백색 LED를 구현 할 수 있다. 이 공정에서 기판의 온도가 불균일해지면 wafer 파장 균일도가 나빠지므로 백색 LED의 yield가 떨어진다. 균일한 기판 온도를 갖기 위한 조건으로 기판과 induction heater의 간격, 가스의 흐름, 기판의 회전, 유도가열코일의 디자인 등이 장비의 설계 요소이다. 본 연구에서는 유도가열방식의 유도가열히터를 이용하여 기판과 히터의 간격에 차이에 따른 기판 균일도 측정했고, 회전에 의한 기판의 온도분포와 자기장분포의 실험적 결과를 상용화 유체역학 코드인 CFD-ACE+의 모델링 결과와 비교 했다. 또한 가스의 inlet위치에 따른 기판의 온도 균일도를 측정하였다. 본 연구에서 사용된 가열원은 유도가열히터 (Viewtong, VT-180C2)를 사용했고, 가열된 흑연판 표면의 온도를 2차원적으로 평가하기 위하여 적외선 열화상 카메라 (Fluke, Ti-10)를 이용하여 온도를 측정했다. 와전류에 의한 흑연판의 가열 현상을 누출 전계의 분포로 확인하기 위하여 Tektronix사의 A6302 probe와 TM502A amplifier를 사용했다. 흑연판 위에 1 cm2 간격으로 211곳에서 유도 전류를 측정했다. 유도전류는 벡터양이므로 $E{\theta}$를 측정했으며, 이때의 측정 방향은 흑연판의 원주방향이다. 또한 자기장에 의한 유도전류의 분포를 확인하기 위하여 KANETEC사의 TM-501을 이용하여 흑연판 중심으로부터 10 mm 간격으로 자기장을 측정 했다. 저항 가열 히터를 통하여 대류에 의한 온도 균일도를 평가한 결과 gap이 3 mm일때, 평균 온도 $166.5^{\circ}C$에서 불균일도 6.5%를 얻었으며, 회전에 의한 온도 균일도 측정 결과는 2.5 RPM일 때 평균온도 $163^{\circ}C$에서 5.5%의 불균일도를 확인했다. 또한 CFD-ACE+를 이용한 모델링 결과 자기장의 분포는 중심이 높은 분포를 나타냄을 확인했고, 기판의 온도분포는 중심으로부터 55 mm되는 곳에서 300 W/m3로 가장 높은 분포를 나타냈다. 가스 inlet 위치를 흑연판 중심으로 수직, 수평 방향으로 흘려주었을 때의 불균일도는 각각 10.5%, 8.0%로 수평 방향으로 가스를 흘려주었을 때 2.5% 온도 균일도 향상을 확인했다.

  • PDF

Efficient Prediction of Aerodynamic Heating of a High Speed Aircraft for IR Signature Analysis (적외선 신호 분석을 위한 고속 항공기의 공력가열에 관한 효율적 예측)

  • Lee, Ji-Hyun;Chae, Jun-Hyeok;Ha, Nam-Koo;Kim, Dong-Geon;Jang, Hyun-Sung;Myong, Rho-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.11
    • /
    • pp.768-778
    • /
    • 2019
  • The ability to calculate aerodynamic heating and surface temperature is essential to ensure proper design of aircraft components in high speed flight. In this study, various empirical formulas for efficiently calculating aerodynamic heating of aircraft were first analyzed. A simple computational code based on empirical formulas was developed and then compared with commercial codes; ANSYS FLUENT based on the Navier-Stokes-Fourier equation, and ThermoAnalytics MUSES based on an empirical formula. The code was found to agree well with the results of FLUENT in the wall and stagnation point temperatures. It also showed excellent agreement with MUSES, within 1% and 5% in temperature and heat flux, respectively.

An Experimental Study on the Drying and Curing Characteristics of Conductive metallic ink using Combined IR and Hot Air Type in the Roll-to-Roll System (R2R 공정에서 적외선가열과 열풍을 혼합한 건조방식에서 전도성 금속 잉크의 건조 및 큐어링 공정 특성에 관한 실험적 연구)

  • Kim, Young-Mo;Hong, Seung-Chan;Lee, Jai-Hyo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.2
    • /
    • pp.73-78
    • /
    • 2010
  • This research is about the drying and curing characteristic of conductivity metallic ink on-line curing device in order to improve the curing time for productivity in RFID Gravure printing. The curing process is carried out to increase the electric conductivity after the metallic ink is printed on the substrate. The metal ink is composed of nano-sized silver or copper particles. In this research, the combined IR and Hot air curing system is used and its results is compared with those of oven, IR and Hot Air type respectively. Generally the curing time in the past is about 3 minutes. But the combined system (IR+Hot Air) in this research shows that curing time is less than 30 seconds. These results is much faster than those of other system. This study can be help to make Roll-to-Roll drying and curing process for mass and continuous production on-line.

The Effect of Impact Velocity on Droplet-wall Collision Heat Transfer Above the Leidenfrost Point Temperature (Leidenfrost 지점 온도 이상에서 액적-벽면 충돌 열전달에 대한 충돌 속도의 영향)

  • Park, Jun-seok;Kim, Hyungdae;Bae, Sung-won;Kim, Kyung Doo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.567-578
    • /
    • 2015
  • Single droplet-wall collision heat transfer characteristics on a heated plate above Leidenfrost temperature were experimentally investigated considering the effects of impact velocity. The collision characteristics of the droplet impinged on the heated wall and the changes in temperature distribution were simultaneously measured using synchronized high-speed video and infrared cameras. The surface heat flux distribution was obtained by solving the three-dimensional transient heat conduction equation for the heated substrate using the measured surface temperature data as the boundary condition for the collision surface. As the normal impact velocity increased, heat transfer effectiveness increased because of an increase in the maximum spreading diameter and a decrease in the vapor film thickness between the droplet and heated wall. For We < 30, droplets stably rebounded from a heated wall without breakup. However, the droplets broke up into small droplets for We > 30. The tendency of the heat transfer to increase with increasing impact velocity was degraded by the transition from the rebounding region to the breakup region; this was resulted from the reduction in the effective heat transfer area enlargement due to the breakup phenomenon.

Analysis of Heating Effect of an Infrared Heating System in a Small Venlo-type Glasshouse (소형 벤로형 유리온실에서 적외선등 난방 시스템의 난방효과 분석)

  • Lim, Mi Young;Ko, Chung Ho;Lee, Sang Bok;Kim, Hyo Kyeong;Bae, Yong Han;Kim, Young Bok;Yoon, Yong Cheol;Jeong, Byoung Ryong
    • FLOWER RESEARCH JOURNAL
    • /
    • v.18 no.3
    • /
    • pp.186-192
    • /
    • 2010
  • An infrared heating system, installed in a small venlo-type glasshouse ($280m^2$) in Gyeongsang National University, Jinju, Korea, was used to investigate its heating effect with potted Phalaenopsis, Schefflera arboricola 'Hongkong', Ficus elastica 'Variegata', and Rosa hybrida 'Yellow King' as the test plants. Temperature changes in test plants with the system turned 'On' and 'Off' were measured by using an infrared camera and the consumption of electricity by this infrared heating system was measured and analyzed. In potted Phalaenopsis, when the set air temperature of the greenhouse was $18^{\circ}C$, temperature of leaves and the growing medium were $22.8{\sim}27^{\circ}C$ and $21.3{\sim}24.3^{\circ}C$, respectively. In such tall plants as Schefflera arboricola 'Hongkong' and Ficus elastica 'Variegata', the upper part showed the highest temperature of 24.0 and $26.9^{\circ}C$, respectively. From the results of temperature change measurements, the plant temperatures were near or above the set point temperatures with some fluctuations depending on the position or distance from the infrared heating system. When air temperature between night and dawn dropped sharply, plant temperatures were maintained close to the set temperature ($18^{\circ}C$). There was a significant difference between 'On' and 'Off' states of the infrared heating system in average temperatures of root zone and leaf: 21.8 and $17.8^{\circ}C$ with the system 'On' and 20.4 and $15.5^{\circ}C$ with the system 'Off', respectively, in a cut rose Rosa hybrida 'Yellow King'. The heating load was about $24,850{\sim}35,830kcal{\cdot}h^{-1}$, which comes to about 27,000~40,000 won in Korean currency when calculated in terms of the cost of heating by a hot water heating system heated by petroleum. The cost for heating by the infrared heating system was about 35% of that of a hot water heating system. With the infrared heating system, the air temperature during the night was maintained slightly lower than the set point air temperature, probably due to the lack of air tightness of the glasshouse. Therefore, glasshouses with an infrared heating system requires further investigation including the installation space of the heat-emitting units, temperature sensor positions, and convection.

Construction and Measurement of Normal Spectral Emissivity Device using Fourier Transform Infrared Spectrometer (퓨리에 변환 적외선 분광기를 이용한 수직 분광 복사율 측정 장치의 제작과 측정)

  • Jeon, Sang-Ho;Yoo, Nam-Joon;Jo, Jae-Heung;Park, Chul-Woung;Park, Seung-Nam;Lee, Geun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.400-407
    • /
    • 2008
  • An Instrument to measure normal spectral emissivity is built using a Fourier Transform-Infrared (FT-IR) spectrometer. The instrument is composed of four main parts, reference blackbody, sample furnace, optics system, and FT-IR spectrometer. Measurement ranges of temperature and wavelength are $200^{\circ}C{\sim}500^{\circ}C$ and $3.5{\mu}m{\sim}20{\mu}m$, respectively. Measured emissivity of the reference blackbody is greater than 0.9993 with combined relative uncertainty less than 0.69%, which can be considered an ideal blackbody. We studied the emissivity of opaque alumina, graphite, anodized aluminum, and steel (IMS 200). It is shown that emissivity increases with the roughness of the steel (IMS 200) surface.

Preparation and Characterization of Sulfated Fibroin (황산기가 도입된 피브로인의 제조 및 특성)

  • Jeong, Dae-Cheol;Lee, Shin-Young;Hur, Won
    • KSBB Journal
    • /
    • v.24 no.5
    • /
    • pp.458-462
    • /
    • 2009
  • Silk fibroin is a structural protein from Bombyx mori and can be sulfated to provide biofunctional polypeptides showing antiviral and anticoagulating activities. However, the sulfated fibroins have not been characterized enough to present their compositions and structures. In this report, sulfation reaction was investigated by varying the reaction temperature and sulfuric acid concentration and analysis of the resulting peptides were carried out. The degree of sulfation was proportion to sulfuric acid concentration but the maximum product yield was obtained at $60^{\circ}C$ and 5% of sulfuric acid concentration. FT-IR spectrum, UV absorption and NMR spectrum support that o-sulfate ester was formed at the hydroxyl group of serine and tyrosine residues. Size exclusion chromatography identified that sulfated fibroin was composed of a highly hydrolyzed polypeptide mixtures and peptides of relatively higher molecular weight.

Weed and Pest Control by Means of Physical Treatments;Effect of infrared irradiation on loam for weed control (물리적인 방법을 이용한 잡초 및 병해충 방제 방법의 개발;적외선 조사에 의한 잡초방제를 위한 양토의 가열 효과)

  • Kang, Whoa-Seug;Yu, Chang-Yeon;Shin, Hyun-Dong;Kang, Wie-Soo;Oh, Jae-Heun
    • Korean Journal of Environmental Agriculture
    • /
    • v.15 no.1
    • /
    • pp.91-104
    • /
    • 1996
  • The viability loss or death of weed seeds buried in soil can be induced by infrared irradiation which has good penetration in moist soil. By using this principle of pre-emergence soil-treatment, the study was carried out to obtain basic information needed to develop the effective weed control method for the production of less polluted agricultural products. An apparatus for irradiating infrared was constructed by using ceramic material with high emissivity. The LPG was used as fuel for producing infrared by heating ceramic material. The soil heated in this study was loam with four levels of moisture contents (0.6, 5.7, 10.7, 15.1 % wb). The temperature distribution was measured at various soil depths when soil with different moisture content was irradiated with infrared for three different times (30, 60, 90 sec). The soil depths with duration time of minimum 3 minutes over $80^{\circ}C$, temperature inducing viability loss of weed seeds, were investigated. When the moisture content of soil was 0.6 and 5.7 % wb, the soil depths which can induce viability loss of weed seeds was greatly increased with increasing irradiation time. However, any depths of soil tested in this study was not reached to the temperature of $80^{\circ}C$ when 30 seconds of irradiation time was applied on soil with moisture content of 10.7 or 15.1 % wb. Generally, the soil depth needed for viability loss of weed seeds was decreased with increasing moisture content of soil. Also, longer irradiation time was required to induce viability loss of weed seeds with increasing moisture content of soil.

  • PDF

Sensitivity Study on the Infra-Red Signature of Naval Ship According to the Composition Ratio of Exhaust Plume (폐기가스 조성 비율이 적외선 신호에 미치는 영향 연구)

  • Cho, Yong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.103-110
    • /
    • 2018
  • Infrared signatures emitted from naval ships are mainly classified into internal signatures generated by the internal combustion engine of the ship and external signatures generated from the surface of the ship heated by solar heat. The internal signatures are also affected by the chemical components ($CO_2$, $H_2O$, CO and soot) of the exhaust plumes generated by the gas turbine and diesel engine, which constitute the main propulsion system. Therefore, in this study, the chemical composition ratios of the exhaust plumes generated by the gas turbines and diesel engines installed in domestic naval ships were examined to identify the chemical components and their levels. The influence of the chemical components of the exhaust plumes and their ratios on the infrared signatures of a naval ship was investigated using orthogonal arrays. The infrared signature intensity of the exhaust plumes calculated using infrared signature analysis software was converted to the signal-to-noise ratio to facilitate the analysis. The signature analysis showed that $CO_2$, soot and $H_2O$ are the major components influencing the mid-wave infrared signatures of both the gas turbine and diesel engine. In addition, it was confirmed that $H_2O$ and $CO_2$ are the major components influencing the long-wave infrared signatures.