• Title/Summary/Keyword: 적분기

Search Result 730, Processing Time 0.024 seconds

Robust Control of Flexible Joint Robot Using ISMC and IDA-PBC (ISMC와 IDA-PBC를 이용한 유연관절로봇의 강인제어)

  • Asignacion, Abner Jr.;Park, Seung-kyu;Lee, Min-wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.6
    • /
    • pp.1203-1211
    • /
    • 2017
  • This paper proposes a robust controller for flexible joint robots to achieve tracking performance and to improve robustness against both matched and mismatched disturbances. The proposed controller consists of a disturbance observer(DOB), passivity-based controller, and integral sliding mode controller(ISMC) in a backstepping manner. The DOB compensates the mismatched disturbance in the link-side and formulates the reference input for the motor-side controller. Interconnection and damping assignment passivity-based controller (IDA-PBC) performs tracking control of motor-side, and it is integrated to nominal control of ISMC to guarantee the over-all stability of the nominal system, while, matched disturbances are decoupled by the discontinuous control of ISMC. In the design of the link-side controller, PD type impedance controller is designed with DOB and this leads the continuous control input which is suitable to the reference input for the motor-side.

PID Controller Tuning for Integrating Processes with Time Delay (시간지연을 갖는 적분시스템용 PID 제어기의 동조)

  • Lee Yun-Hyung;Ahn Jong-Kap;Kim Min-Jung;So Myung-Ok;Jin Gang-Gyoo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.325-330
    • /
    • 2006
  • Integrating processes are frequently encountered in process industries. Generally they are most commonly associated with level control problems. In this paper, tuning formulae of PID controllers for set-point tracking and load disturbance rejection are presented on integrating processes with time delay. In particular, the controller parameters are determined such that performance criteria(IAE, ISE and ITSE) are minimized. Optimal PID parameter sets are obtained by means of a real-coded genetic algorithm(RCGA) and then tuning rules are addressed using obtained PID parameter sets and another RCGA. The performances of the proposed tuning rules are tested on two processes.

  • PDF

Design of controller for DC/DC boost converter using PI observer (PI 관측기를 이용한 DC/DC 승압 컨버터 제어기 설계)

  • Kim, In-Hyuk;Jeong, Goo-Jong;Son, Young-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1650_1651
    • /
    • 2009
  • DC/DC 승압 컨버터는 인덕터 내부 저항으로 인하여 부하 저항의 변화가 시스템 동작점에 영향을 미치게 되며, 이로 하여 제어기 설계의 기준이 되는 선형화된 모델은 불확실성을 가지게 된다. 본 논문은 인덕터의 내부 저항과 출력단의 부하 변동으로 인한 불확실성에 대하여 출력 전압의 강인성을 향상시키기 위해 PI 관측기 기반 적분형 상태 변수 궤환 제어기를 제안한다. PI 관측기는 불확실한 시스템 제어에 널리 사용되는 오차의 적분항을 Luenberger 관측기에 추가한 형태로써 불확실성에 강인한 추정 성능을 보인다. 모의실험을 통해 불확실성이 존재하는 경우 제안된 제어기의 강인성을 확인하고 설계된 관측기가 Luenberger 관측기에 비해 상태변수 추정 성능이 우수함을 보인다.

  • PDF

Current Regulated Delta Modulator for Series Resonant Inverter with Transformer-Coupled Load (변압기-결합형 직렬공진 인버터의 델타변조 전류제어)

  • 안희욱;김학성
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.231-239
    • /
    • 1999
  • An improved version of current-regulated delta modulator (CRDM) is investigated for the output cunent control of v voltage-source inverters that have transformer-coupled series resonant load and are operated at the resonant frequency. Conventional CRDM has not only CUlTent offset problem but also transformer flux saturation problem when i it is applied to induction heating systems that have transformel-coupled loads. To cope with these problems, the effect of flux saturation is analysed, and simple method to av이d the problem is proposed. And integral type of CRDM is a adopted to remove the cunent offset. The boundaries of integrator gain for stable operation is calculated using the c concept of sliding mode controL The validity of proposed strategy is vel퍼ed through simulations and prototype e experiments.

  • PDF

Robust Controller Design and Analysis Using Disturbance Observer and Integral Control (외란 관측기와 적분제어기를 이용한 강인 제어기 설계 및 분석)

  • Park, Hong-Seob;Lee, Chung-Woo;Chung, Chung-Choo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.514-516
    • /
    • 2005
  • 압전 구동기(Piezo actuator)는 수 나노미터 수준의 위치정밀도와 고분해능을 가지고 있으나 비선형 특성인 히스테리시스(Hysteresis)는 정상상태에서 위치 오차를 발생하는 주요 원인이 된다. 현재까지 히스테리시스를 보상하기 위해 피 프 포워드 제어 방법, Pl 제어 방법, $H_{\infty}$제어 방법 등이 연구되어 왔지만 저주파 대역의 외란(disturbance)까지 고려하여 시스 템을 주파수 영역에서 설계, 분석하는 방법에 대한 연구는 미흡하였다. 본 논문은 압전 구동기의 위치 제어를 위한 제어기의 설계와 이를 주파수 영역에서 분석하는 내용을 다룬다. 제어기의 설계는 히스테리시스를 보상하기 위해 극점 배치 방법과 외란 관측기(Disturbance observer)를 기본으로 하였으며 적분제어를 적용하여 시스템 민감도(sensitivity)를 개선하였다. 시뮬레이션과 실험을 통하여 설계한 제어기가 히스데리시스에 대한 보상과 민감도의 개선에 효율적임을 검증하였다.

  • PDF

Design of 4th Order ΣΔ modulator employing a low power reconfigurable operational amplifier (전력절감용 재구성 연산증폭기를 사용한 4차 델타-시그마 변조기 설계)

  • Lee, Dong-Hyun;Yoon, Kwang-Sub
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1025-1030
    • /
    • 2018
  • The proposed modulator is designed by utilizing a conventional structure employing time division technique to realize the 4th order delta-sigma modulator using one op-amp. In order to reduce the influence of KT/C noise, the capacitance in the first and second integrators reused was chosen to be 20pF and capacitance of third and fourth integrators was designed to be 1pF. The stage variable technique in the low power reconfigurable op-amp was used to solve the stability issue due to different capacitance loads for the reduction of KT/C noise. This technique enabled the proposed modulator to reduce the power consumption of 15% with respect to the conventional one. The proposed modulator was fabricated with 0.18um CMOS N-well 1 poly 6 metal process and consumes 305uW at supply voltage of 1.8V. The measurement results demonstrated that SNDR, ENOB, DR, FoM(Walden), and FoM(Schreier) were 66.3 dB, 10.6 bits, 83 dB, 98 pJ/step, and 142.8 dB at the sampling frequency of 256kHz, oversampling ratio of 128, clock frequency of 1.024 MHz, and input frequency of 250 Hz, respectively.

Model Reduction of LTI systems via Improved BPF integral operation matrix (개선된 블럭펄스 적분연산행렬을 이용한 LTI 시스템 모델축소)

  • Cho, Young-Ho;Shim, Jae-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.279-281
    • /
    • 2006
  • 적분연산행렬은 구간연속 직교함수들이 시스템 동정, 해석, 제어기 설계 등의 분야에 널리 이용될 수 있는 계기를 제공하였다. 특히 블럭펄스 함수는 연산이 간단하기 때문에 선형 시변계와 비선형계 등의 제어문제 둥에 널리 이용되어 오고 있다. 본 논문은 기존의 블럭펄스 함수 적분 연산행렬과 비교했을 때 적분오차를 줄이는 적분연산행렬을 소개하였으며, 이를 이용하여 고차 시스템의 응답에 가장 최적한 응답을 갖는 저차 시스템의 응답을 갖도록 최적응답 방법에 적용하여 대수적인 방법으로 저차 시스템의 파라메터를 구하는 알고리즘을 제시함으로서 유용성을 확인하였다.

  • PDF

Modification of the Sloan치s Substepping Scheme for the Numerical Stress Integration of Elasto-plastic Constitutive Models (탄소성 구성 모델의 수치 응력 적분을 위한 단계분할 절차에 관한 연구)

  • 김범상;정충기
    • Geotechnical Engineering
    • /
    • v.14 no.4
    • /
    • pp.129-140
    • /
    • 1998
  • Elasto-plastic finite element analysis of geotechnical boundary value problems necessitate the stress integration for the known strain increments. For the elasto-plastic constitutive model, the stress integration is generally achieved by numerical schemes, because analytical integration is impossible for general strain path. In this case, the accuracy of numerical stress integration has an important role on the overall accuracy of nonlinear finite element solution. In this study, the Sloan's substepping method which is one of explicit integration methods has been adopted and iris applicability has been checked. The unstability and inaccuracy of ifs results initiated from initial stress level were revealed. So. a new modified numerical integration method which employs the basic concept of modified Euler scheme for error control is proposed and accuracy and stability of the solutions are confirmed by triaxial test simulation.

  • PDF

Online State-of-Charge Estimation Algorithm Using Proportional-Integral Observer (비례적분 관측기를 이용한 실시간 잔존용량 추정 알고리즘)

  • Kim, Nari;Ahn, Jung-Hoon;Lee, Byung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.13-14
    • /
    • 2015
  • 본 논문은 추정 정확도를 높이기 위해 비례적분 관측기를 이용한 실시간 잔존용량 추정 알고리즘을 제안한다. 시뮬레이션을 통해 제안하는 알고리즘의 타당성을 검증하였고, 초기 잔존 용량이 불명확하거나 배터리 모델 파라미터 값이 실제와 일치하지 않더라도 평균 추정오차는 0.3% 미만으로 확인되었다.

  • PDF

Development of Anti-windup Techniques for Cascade Control System (다단제어용 안티 와인드업 기술 개발)

  • Bae, Jeong Eun;Kim, Kyeong Hoon;Chu, Syng Chul;Heo, Jaepil;Lim, Sanghun;Sung, Su Whan
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.430-437
    • /
    • 2020
  • In this research, the anti-windup techniques for the cascade control system are newly developed. Cascade control system has an additional internal feedback control loop to reject disturbances better than the conventional control system. Remarkable difference between the conventional single-loop control system and the cascade control system is the interaction that the controller output saturation of the secondary control loop strongly affects the integral action of the primary control loop. In industry, local back calculation anti-windup method has been mainly used for each controller without considering the interaction between the two controllers. But it cannot eliminate the integral-windup of the primary controller originated from the saturation of the secondary controller output. To solve the problem, the two anti-windup techniques of the cascade conditional integration and the cascade back calculation are proposed in this research by extending the local anti-windup techniques for the single-loop control system to the cascade control system. Simulation confirmed that the proposed methods can effectively remove the integral windup of the primary controller caused by the saturation of the secondary controller output and show good control performances for various types of processes and controllers. If the reliability of the proposed methods is proved through the applications to real processes in the future, they would highly contribute to improving the control performances of the cascade control system in industry.