• Title/Summary/Keyword: 저 LET

Search Result 30, Processing Time 0.022 seconds

Fabrication of Sub-100 nm Embossing Patterns using Weakly-Polymerized Region via Long-Exposure Technique (LET) in Two-Photon Polymerization (긴 레이저 조사방식에 의한 저밀도 이광자 광중합 영역을 이용한 Sub-100nm 정밀도의 엠보싱 패턴제작)

  • Park, Sang-Hu;Lim, Tae-Woo;Yang, Dong-Yol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.1 s.190
    • /
    • pp.64-70
    • /
    • 2007
  • A long-exposing technique (LET) has been conducted to create nanoscale patterns applicable to diverse micro-devices using two-photon polymerization (TPP). By the weakly-polymerized region via the LET, double-layered embossing patterns can be fabricated simply in a single step. The LET makes possible a voxel and its surrounding to be fully grown into more than 500 nm in lateral size and weakly-polymerized region (WPR), respectively. In the WPR. interconnecting ribs between voxels are generated, and they lead to the creation of double-layered dot patterns. Moreover, by controlling the distance between voxels, various shapes of interconnecting rib can be fabricated when the LET is applied. Various embossing patterns were fabricated to evaluate the usefulness of the proposed technique as a novel nanopatterning technique in TPP.

Effect on Pancreatic Beta Cells and Nerve Cells by Low LET X-ray (Low LET X-ray가 췌장 ${\beta}$ 세포와 신경세포에 미치는 효과)

  • Park, Kwang-Hun;Kim, Kgu-Hwan
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.21-28
    • /
    • 2014
  • Cultured pancreatic beta cells and nerve cells, it is given normal condition of 10% FBS (fetal bovine serum), 11.1 mM glucose and hyperglycemia codition of 1% FBS, 30 mM glucose. For low LET X-ray irradiated with 0.5 Gy/hr dose-rate(total dose: 0.5 to 5 Gy). Survival rates were measured by MTT assay. When non irradiated, differentiated in the pancreatic beta cells experiment is hyperglycemia conditions survival rate compared to normal conditions survival rate seemed a small reduction. However increasing the total dose of X-ray, the survival rate of normal conditions decreased slightly compared to the survival rate of hyperglycemia conditions, the synergistic effect was drastically reduced. When non irradiated, undifferentiated in the nerve cells experiment is hyperglycemia conditions survival rate compared to normal conditions survival rate seemed a large reduction. As the cumulative dose of X-ray normal conditions and hyperglycemia were all relatively rapid cell death. But the rate of decreased survivals by almost parallel to the reduction proceed and it didn't show synergistic effect.

Fabrication of sub-30 nm nanofibers using weakly two-photon induced photopolymerized region (저밀도 이광자 광중합 영역을 이용한 30 nm 이하의 패턴제작)

  • Park, Sang-Hu;Lim, Tae-Woo;Yang, Dong-Yol
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1249-1253
    • /
    • 2007
  • Experimental studies on the fabrication of sub-30 nm nanofibers using weakly two-photon induced photopolymerized region have been carried out. For the generation of nanofibers inside or outside microstructures, an over-polymerizing method involving a long exposure technique (LET) was proposed. Such nanofibers can find meaningful applications as bio-filters, mixers, and many other uses in diverse research field. A multitude of nanofibers with a notably high resolution (about 22 nm) in two-photon polymerization was achieved using the LET. Furthermore, it was demonstrated that the LET can be employed for the direct fabrication of various embossing patterns by controlling the exposure duration and the interval between voxels. Thin interconnecting networks are formed regularly in the boundary of the over-polymerized region, which allows for the creation of various pattern shapes. Overall of this work, some patterns including nanofibers are fabricated by the LET.

  • PDF

Fabrication of Microchannels Having Sub-30 nm Nanofibers Inside of Them via Overlapping Weakly Two-Photon Polymerized Region (저밀도 이광자 광중합 영역의 중첩방법을 이용한 기능성 마이크로 채널 제작에 관한 연구)

  • Park, Sang-Hu;Lim, Tae-Woo;Yang, Dong-Yol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.12
    • /
    • pp.1144-1149
    • /
    • 2007
  • Experimental studies on the fabrication of sub-30 nm nanofibers using weakly two-photon induced photopolymerized region have been carried out. For the generation of nanofibers inside or outside microstructures, an over-polymerizing method involving a long exposure technique (LET) was proposed. Such nanofibers can find meaningful applications as bio-filters, mixers, and many other uses in diverse research field. A multitude of nanofibers with a notably high resolution (about 22 nm) in two-photon polymerization was achieved using the LET. Furthermore, it was demonstrated that the LET can be employed for the direct fabrication of various embossing patterns by controlling the exposure duration and the interval between yokels. Thin interconnecting networks are formed regularly in the boundary of the over-polymerized region, which allows for the creation of various pattern shapes. Overall of this work, some patterns including nanofibers are fabricated by the LET.

Low Complexity LDPC Encoder (저 복잡도 LPDC 부호화기)

  • Jiang, Xueqin;Lee, Moon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.252-254
    • /
    • 2007
  • In this paper, we will introduce an encoding algorithm of LDPC Codes in Direct-Sequence UWB systems. We evaluate the performance of the coded systems in an AWGN channel. This new algorithm is based on the Jacket matrics. Mathematically let A = ($a_{kl}$) be a matnx, if $A^{-1}$ = $(a^{-1}_{kl})^r$,then the matrix A is a Jacket matrix. If the Jacket matrices if Low density, the inverse matrices is also Low density which is very important to the introduced encoding algorithm.

  • PDF

Low Fertility Era and Maternal Health Promotion (저출산 시대와 모성의 건강증진)

  • Jeon, Byeong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.6
    • /
    • pp.162-173
    • /
    • 2014
  • Among OECD countries, Korea is the only country which has continuously recorded total birthrate below 1.3 person for over 10 years. Since 2006, the Korean government has promoted the population policy in full scale. But, the fertility rate which became low has not shown any sign to go up again. Thus, Korea can be understood as having fallen into 'low fertility trap'. Such a low fertility can cause serious problems such as weakening of national competitive power and even survival of the country. In Korea, due to studies and finding jobs among young women, their childbirths are kept being postponed. In some cases, poor working conditions where women work can cause physical conditions not appropriate for pregnancy. Thus, it is very important to let childbearing women, pregnant women take care of their health. Accordingly, conscious of this low fertility era, this study examined major international organizations and countries' health promoting strategies-with focus on motherhood and suggested some methods to effectively improve health for motherhood.

Measurement of Growth Delay and the Oxygen Enhancement Ratio of Fast Neutron Beam Using Mouse Model System (마우스모델을 이용한 고속중성자선의 성장지연 및 산소증강비의 측정)

  • Eom, Keun-Yong;Park, Hye-Jin;Kwon, Eun-Kyung;Ye, Sung-Joon;Lee, Dong-Han;Wu, Hong-Gyun
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.178-183
    • /
    • 2007
  • Neutrons are high LET (linear energy transfer) radiation and cause more damage to the target cells than x-rays or gamma rays. The damage from neutrons is generally considered fatal to a cell and neutrons have a greater tendency to cause cell death through direct interaction on DNA. We performed experiments to measure growth delay ratio and oxygen enhancement ratio (OER) in mouse model system. We inoculated EMT-6 cells to the right hind leg of BALB-c mouse and X-rays and neutron beams were given when the average volume of tumors reached $200-300mm^3$. We irradiated 0, 11, 15.4 Gy of X-ray and 0, 5, 7 Gy of fast neutron beam at normoxic and hypoxic condition. The volume of tumors was measured 3 times per week. In x-ray experiment, growth delay ratio was 1.34 with 11 Gy and 1.33 with 15.4 Gy in normoxic condition compared to in hypoxic condition, respectively. In neutron experiment, growth delay ratio was 0.94 with 5 Gy and 0.98 with 7 Gy, respectively. The OER of neutron beam was 0.97. The neutron beam was more effective than X-ray in the control of hypoxic tumors.

Design of a 10 bit Low-power current-mode CMOS A/D converter with Current predictors (전류예측기를 이용한 10비트 저전력 전류구동 CMOS A/D 변환기 설계)

  • 심성훈;권용복;윤광섭
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.10
    • /
    • pp.22-29
    • /
    • 1998
  • In this paper, an 10 bit current-mode CMOS A/D converter with a current predictor is designed with a CMOS process to be integrated into a portable image signal processing system. A current predictor let the number of comparator reduce to 70 percent compared with the two step flash architecture. The current magnitude of current reference is reduced to 68 percent with a modular current reference. The designed 10 bit Low-power current-mode CMOS A/D converter with a current predictor is simulated with HSPICE using 0.6$\mu\textrm{m}$ N-well single-poly triple-metal CMOS process parameters. It results in a conversion rate of 10MSamples/s. A power consumption is measured to be 94.4mW at single +5V supply voltage. The 10 bit A/D converter fabricated using the same process occupies the chip area of 1.8mm x 2.4mm.

  • PDF

An Analysis on the Number of Advertisements for Device Discovery in the Bluetooth Low Energy Network (저전력 블루투스 네트워크에서 장치 탐색을 위한 Advertising 횟수에 관한 분석)

  • Kim, Myoung Jin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.3-12
    • /
    • 2016
  • Bluetooth Low Energy (BLE) protocol has attracted attention as a promising technology for low data throughput and low energy wireless sensor networks. Fast device discovery is very important in a BLE based wireless network. It is necessary to configure the network to work with minimized energy consumption because the BLE network nodes are expected to operate a long time typically on a coin cell battery. However, since it is difficult to obtain low energy and low latency at the same time, the BLE standard introduces wide range setting of parameters related to device discovery process and let the network operators to set up parameter values for the application. Therefore, it is necessary to analyze the performance of device discovery according to the related parameter values prior to BLE network operation. In this paper we analyze the expected value and the cumulative distribution function of the number of advertisements for device discovery in the BLE network. In addition, we propose a scheme for controlling the interval between advertising events that can improve the performance of device discovery without increasing energy consumption.

TID and SEL Testing on PWM-IC Controller of DC/DC Power Buck Converter (DC/DC 강압컨버터의 PWM-IC 제어기의 TID 및 SEL 실험)

  • Lho, Young Hwan;Hwang, Eui Sung;Jeong, Jae-Seong;Han, Changwoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.1
    • /
    • pp.79-84
    • /
    • 2013
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a PWM-IC (pulse width modulation-integrated circuit) controller, a MOSFET (metal-oxide semiconductor field effect transistor), inductor, capacitor, etc. It is shown that the variation of threshold voltage and the offset voltage in the electrical characteristics of PWM-IC increase by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 4 heavy ions applied for SEL (Single Event Latch-up) make the PWM pulse unstable. Also, the output waveform for the given input in the DC/DC converter is observed by the simulation program with integrated circuit emphasis (SPICE). TID testing on PWM-IC is accomplished up to the total dose of 30 krad, and the cross section($cm^2$) versus LET($MeV/mg/cm^2$) in the PWM operation is studied at SEL testing after implementation of the controller board.