• Title/Summary/Keyword: 저환기

Search Result 133, Processing Time 0.033 seconds

Implementation of Wideband Low Noise Down-Converter for Ku-Band Digital Satellite Broadcasting (Ku-대역 광대역 디지탈 위성방송용 저 잡음하향변환기 개발)

  • Hong, Do-Hyeong;Lee, Kyung Bo;Rhee, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.2
    • /
    • pp.115-122
    • /
    • 2016
  • In this paper, wideband Ku-band downconverter was designed to receiver digital satellite broadcasting. The low-nose downconverter was designed to form four local oscillator frequencies(9.75, 10, 10.75 and 11.3 GHz) representing a low phase noise due to VCO-PLL with respect to input signals of 10.7 to 12.75 GHz and 3-stage low noise amplifier circuit by broadband noise matching, and to select intermediate frequency bands by digital control. The developed low-noise downconverter exhibited the full conversion gain of 64 dB, and the noise figure of low-noise amplifier was 0.7 dB, the P1dB of output signal 15 dBm, and the phase noise -85 dBc@10kHz at the band 1 carrier frequency of 9.75 GHz. The low noise block downconverter(LNB) for wideband digital satellite broadcasting designed in this paper can be used for global satellite broadcasting LNB.

Efficacy of Low-dose Hydrocortisone Infusion for Patients with Severe Community-acquired Pneumonia Who Invasive Mechanical Ventilation (기계 환기가 요구된 중증 지역사회 획득 폐렴에서 저용량 하이드로코르티손 주입의 효과)

  • Kim, Ho Cheol;Lee, Seung Jun;Ham, Hyoun Seok;Cho, Yu Ji;Jeong, Yi Yeong;Lee, Jong Deok;Hwang, Young Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.4
    • /
    • pp.419-425
    • /
    • 2006
  • Background : Severe community-acquired pneumonia (CAP) can develop into respiratory failure that requires mechanical ventilation (MV), which is associated with a higher rate of mortality. It was recently reported that a hydrocortisone infusion in severe CAP patients was associated with a significant reduction in the length of the hospital stay and mortality. This study evaluated efficacy of a hydrocortisone infusion for patients with severe CAP requiring MV. Methods : From February 2005 to July 2005, 13 patients (M : F = 10 : 3, mean age: $68.6{\pm}14.1years$), who were diagnosed with severe CAP and required MV, were enrolled in this study. Hydrocortisone was administered as an intravenous 200mg loading bolus, which was followed by an infusion at a rate of 10mg/hour for 7 days. The control group was comprised of patients with severe CAP requiring MV but in whom corticosteroid was not used before study period. The clinical and physiologic parameters on or by day 8 and the outcome in the hydrocortisone infusion group were compared with those in the control group. Results : 1) There was no significant difference in age, gender ratio, SAPS II, SOFA score, temperature, leukocyte count, PaO2/FiO2 (P/F) ratio, the number of patients with P/F ratio < 200, chest radiograph score, lung injury score and catecholamine-dependent septic shock between the hydrocortisone infusion group and control group at day 1. 2) At day 8, the proportion of patients with an improvement in the P/F ratio ${\geq}100$ and the chest radiograph score was significantly higher in the hydrocortisone infusion group than in the control group (61.5% vs. 15.4%, 76.9% vs. 23.1%, p< 0.05). However, there was no significant difference in the other clinical and physiologic parameters. 3). There was no significant difference in the duration of the MV, ICU stay, hospital stay and 10th and 30th day mortality between the two groups. Conclusion : Hydrocortisone infusion for patients with severe CAP requiring invasive mechanical ventilation may be effective in improving the level of oxygenation and the chest radiograph score.

초고진공 펌프개발 -크라이오 펌프와 진공 브레이징의 이해-

  • Yu, Jae-Gyeong;Gang, Min-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.13-13
    • /
    • 2010
  • 개요- 반도체 시장의 확대 및 소자의 고집적화와 장비의 초정밀화 등 고정도 생산성을 요구하는 현대 진공산업 시장에서는 정밀한 제품을 대량으로 생산할 수 있도록 지원할 수 있는 대용량 장비의 수요가 급증하고 있다. 서론- 하루가 다르게 발전하는 기술 경쟁 사회에서는 보다 성능이 좋은 제품을 다른 국가 또는 다른 업체와 차별화된 기술적 우위를 선점해야 한다. 본문-이에따라, 고신뢰도, 고생산성이 요구되는 진공산업 시장에 발맞추기 위한 일환으로 크라이오 펌프의 재생시간을 단축시켜 생산성 향상을 높이고, 기존의 제품에서 소비자가 느꼈던 진동을 최소로 줄일 수 있도록 저진동 제품의 설계를 통한 고객 만족의 제품을 개발함과 동시에, 맥동관 냉동기의 기술상업화를 꾀한 극저온기술 영역의 발전을 함께 도모하고자 한다. 현재까지는 국내의 일부 정부출연 연구소와 학교, 일부 특수산업 분야에서만 크라이오 펌프를 사용하고 있으나, 상업적인 설계 및 생산은 완전히 전무한 상태이다. 이는 진공시장의 잠재적인 성장을 고려할 때 국산화가 시급한 상황이다. 이러한, 상황을 고려하여 현재 기계연구원과 우성진공, 국민대학교가 맥동관 냉동기를 접목시킨 급속재생형 저진동 크라이오 펌프를 지난 2008년부터 산학연 협동으로 개발 진행 중에 있다. 크라이오 펌프의 핵심 기술은 냉동기의 효율에 있다고 볼 수 있으며, 이러한 냉동기의 효과를 높이기 위하여, 제작 공정에 진공 브레이징을 사용하여, 열교환기와 교환기 내의 충진재들과의 정확한 간극을 유지하면서 접합을 할 수 있는 환경요건을 지속적인 실험을 통해 지식을 습득하고 있다. 진공 브레이징은 외관을 아름답고 정교하게 접합할 수 있으므로, 추후 상품으로의 가치를 높일 수 있으며, 서로 다른 이종금속 간의 접합이 가능하여 열교환기의 무산소동과 스테인레스 튜브와의 접합을 가능하게 할 수 있었다. 진공브레이징에 쓰이는 모재는 여러가지가 있으며, 접합의 환경 또한 일반 용접보다 다양하므로 여러번의 실험을 통한다면, 성능은 우수하면서 외관으로 손색이 없는 개발품이 나올수 있겠다는 의견이 모아지고 있는 중이다. 본론- 아직까지는 미국의 CTI사나 일본의 ULVAC 등의 크라이오 펌프의 선진 기업에 비해 기술력이 많이 부족하기는 하지만, 아직 많은 부분이 미개발된 분야이고, 향후 후발국과의 차별을 두어 선진기술을 확보하기 위해서는 기존의 방식을 단순히 따라하는 것이 아닌 남들과 다른 원천기술의 확보가 더 필요하며, 이를 위해 부단한 노력과 시행착오를 거쳐 맥동관 냉동기형 크라이오 펌프라는 기술을 확보할 예정이다.

  • PDF

The Effectiveness of Spiral Computed Tomography as a Diagnostic Tool in Pulmonary Embolism(Comparison of Spiral CT with Ventilation-Perfusion Scan) (폐색전증 진단의 도구로서의 Spiral Computed Tomography의 유용성(폐환기관류주사와의 비교))

  • Koh, Jae-Hyun;Oh, Eun-Young;Park, Jung-Ho;Park, Sang-Joon;Yun, Jung-Hwan;Park, Jung-Woong;Suh, Gee-Young;Chung, Man-Pyo;Lee, Kyung-Soo;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.564-573
    • /
    • 1999
  • Background: With variable symptoms and nonspecific radiographic appearances, pulmonary embolism (PE) is a frequent and often undiagnosed cause of mortality and morbidity. The Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) study suggested that the majority of patients undergoing ventilation-perfusion (V-Q) scan would require additional studies to establish or to exclude the diagnosis of PE. Pulmonary angiography has been regarded as gold standard for diagnosis of PE. However, it is an invasive procedure that may be associated with significant notable morbidity and mortality. Thus, availability of an accurate, noninvasive screening examination is highly desirable. Method: From October 1994 to February 1997, twenty patients (male 13, female 7, range 23-91 years, median 58 years) who were suspected as pulmonary embolism on the basis of clinical evidence and underwent the spiral volumetric computed tomography (spiral CT), were studied retrospectively to evaluate the effectiveness of spiral CT as a diagnostic tool in PE. Results: PE could be excluded with spiral CT in 4 patients ; diagnoses of these patients were lung cancer, pneumonia with lung abscess, bilateral pleural effusion due to congestive heart failure, nonspecific pulmonary abnormality retrospectively. One patient who disclosed high probability in V/Q scan, could be diagnosed as pneumonia with lung abscess and underlying emphysema with spiral CT. Among 4 patients who showed intermediate and low probability in V/Q scan, 3 patients could be confirmed as PE with spiral CT. Spiral CT was helpful in 3 patients, in whom V/Q scan could not be performed due to other reasons (e.g. night time, mechanical ventilation) to confirm the diagnosis of PE. Spiral CT could demonstrate embolus above lobar artery level in 11 patients, and up to segmental artery level in 5 patients. Conclusion: This study demonstrated that spiral CT could allow accurate demonstration of thrombotic clots in centrally localized embolism. Spiral CT could be effective, specific, noninvasive and useful diagnostic screening modality for the diagnosis of pulmonary embolism.

  • PDF

Impact of Design Parameters on Length and Application Effect of Surface Water Heat Exchanger(SWHE) (지표수 열교환기의 용량과 적용 효과에 대한 설계 인자의 영향)

  • Sohn, Byonghu;Min, Kyong-Chon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • Commercial buildings are generally cooling-dominated and therefore reject more heat to a vertical ground heat exchanger(GHE) than they extract over the annual cycle. Shallow ponds can provide a cost-effective means to balance the thermal loads to the ground and to reduce the length of GHE. The objective of this work has been to develop a design tool for surface water heat exchanger(SWHE) submerged in shallow pond. This paper presents the analysis results of the impact of design parameters on the length of SWHE and its application effect on geothermal heat pump(GHP) system using vertical GHE. In order to analysis, We applied ${\epsilon}-NTU$ method on designing the length of SWHE. Analysis results show that the required pipe length of SWHE was decreased with the increase of approach temperature difference and with the decrease of pipe wall thickness. In addition, when the SWHE was applied to the GHP system, the temperature of vertical GHE was more stable than that of standalone GHE system.

Flatness Characteristics Analysis Technique of Attenuator Using Thermal Voltage Converter and AC Measurement Standard (열전압변환기와 교류측정표준을 사용한 감쇠기 평탄도 특성 분석 기법)

  • Cha, Yun-bae;Kim, Boo-il
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.330-337
    • /
    • 2018
  • This paper proposes a technique to analyze the flatness characteristics of the attenuator at 10Hz to $50\text\tiny{MHz}$ on the basis of $1\text\tiny{kHz}$ using a Thermal Voltage Converter and AC measurement standard. In the proposed technique, the input voltage of the attenuator for each measuring frequency is supplied at the same rate as $1\text\tiny{kHz}$ using TVC, and the flatness characteristics of the attenuator are analyzed by the voltage variation indicated in the AC measurement standard. The results of the analysis of the attenuator flatness characteristics show that the maximum uncertainty of $866{\mu}V/V$ can be measured from $10\text\tiny{dB}$ to $70\text\tiny{dB}$ and the uncertainty is reduced by about 37% compared to $2.31\text\tiny{mV}$/V using the network measurement method. The improved attenuator flatness characteristic values can be applied to the frequency flatness calibration from 2.2V to 2.2mV at the low voltage of the AC measurement standard.

Development of a Receiver Downconverter Module for Ka-band Satellite Payload (Ka-Band 위성중계기용 수신하향변환기 모듈 개발)

  • 장동필;염인복;이성팔
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.1
    • /
    • pp.68-74
    • /
    • 2003
  • This paper describes the design and the test results of the receiver-downconverter module for a Ka-band Satellite Payload. The developed module is not only a downconverter that convert the signal of 30.6 GHz∼31.0 GHz to the signal of 20.8 GHz∼21.2 GHz but also is a receiver that has the function of low noise amplification in the front stage. It has been fabricated and tested by the qualified satellite component manufacturing process and it shows the best performance of the receiver-downconverter modules operating at Ka-band frequency up to date. The module has the performance of 1.9 dB-NF, 55 dB-Gain, and 58 dBc-C/I3 fur the two tone signals of -59 dBm input power respectively at ambient temperature. It is a small and light module with the size of 93 mm${\times}$84 mm${\times}$26 mm and the weight of 240 g.

A Study on the Structural Integrity Considering the Installation of a Micro-tube Heat Exchanger (미세튜브 열교환기의 장착을 고려한 구조건전성에 관한 연구)

  • Oh, Se Yun;Kim, Tae Jin;Cho, Jong Rae;Jeong, Ho Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.447-451
    • /
    • 2015
  • The objective of this study is to predict the structural characteristics of a heat exchanger mounted on an aircraft engine using finite element analysis. The plastic fracture and life of the heat exchanger were estimated by a thermo-mechanical analysis. Tensile tests were conducted under high temperature conditions (700, 800, 900, 1000 K) using five specimens to obtain the mechanical properties of the Inconel 625 tubes. To assess the structural characteristics of the heat exchanger, the full and partial models were applied under the operating conditions given by the thermo-mechanical and inertial load. As a result, the case, tubesheet, flange, and mounting components have a reasonable safety margin to the allowable stress assuming a fatigue strength of Inconel 625 of 10000 cycles under 1000 K.

Analysis of Indoor Thermal Environment and Cooling Effects by Ventilation Condition, and Spray irrigation or Nonspray of Single Span Plastic Greenhouses (환기조건 및 관수에 따른 단동 플라스틱 하우스의 냉방효과와 열환경 분석)

  • 허종철;임종환;서효덕;최동호
    • Journal of Bio-Environment Control
    • /
    • v.9 no.1
    • /
    • pp.27-39
    • /
    • 2000
  • In this study, we quantitatively compare the cooling effects of single span plastic greenhouses by opening or shutting of toot and side vents, and operation of fan or sprinkler. With those variables, we simultaneously made experiments at 4 greenhouses under equivalent conditions. By the experiments, the shutting of roof and side vents caused the high temperature difference of indoor and outdoor which the crops cannot be cultivated. However, the opening of the windows effectively reduced the indoor temperature and showed uniform temperature distribution in the greenhouses. The sprinkler abruptly reduced the indoor temperature, and showed excellent cooling effects. Finally, this paper provides the fundamental data for environmental control in greenhouses.

  • PDF

Changes of Blood Gases, Plasma Catecholamine Concentrations and Hemodynamic Data in Anesthetized Dogs during Graded Hypoxia Induced by Nitrous Oxide (아산화질소에 의한 점진적 저산소가스 흡입이 혈중 가스치와 Catecholamine치 및 혈역학에 미치는 영향)

  • Kim, Sae-Yeon;Song, Sun-Ok;Bae, Jung-In;Cheun, Jae-Kyu;Bae, Jae-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.1
    • /
    • pp.97-113
    • /
    • 1998
  • The sympathoadrenal system plays an important role in homeostasis in widely varing external environments. Conflicting findings, however, have been reported on its response to hypoxia. We investigated the effect of hypoxia on the sympathoadrenal system in dogs under halothane anesthesia by measuring levels of circulating catecholamines in response to graded hypoxia. Ten healthy mongreal dogs were mechanically ventilated with different hypoxic gas mixtures. Graded hypoxia and reoxygenation were induced by progressively decreasing the oxygen fraction in the inhalation gas mixture from 21%(control) to 15%, 10% and 5% at every 5 minutes, and then reoxygenated with 60% oxygen. Mean arterial pressure, central venous pressure and mean pulmonary arterial pressure were measured directly using pressure transducers. Cardiac output was measured by the thermodilutional method. For analysis of blood gas, saturation and content, arterial and mixed venous blood were sampled via the femoral and pulmonary artery at the end of each hypoxic condition. The concentration of plasma catecholamines was determined by radioenzymatic assay. According to the exposure of graded hypoxia, not only did arterial and mixed venous oxygen tension decreased markedly at 10% and 5% oxygen, but also arterial and mixed venous oxygen saturation decreased significantly. An increased trend of the oxygen extraction ratio was seen during graded hypoxia. Cardiac output, mean arterial pressure and systemic vascular resistance were unchanged or increased slightly. Pulmonary arterial pressure(PAP) and pulmonary vascular resistance(PVR) were increased by 55%, 76% in 10% oxygen and by 82%, 95% in 5% oxygen, respectively(p<0.01). The concentrations of plasma norepinephrine, epinephrine and dopamine increased by 75%, 29%, 24% in 15% oxygen and by 382%, 350%, 49% in 5% oxygen. These data suggest that the sympathetic nervous system was activated to maintain homeostasis by modifying blood flow distribution to improve oxygen delivery to tissues by hypoxia, but hemodynamic changes might be blunted by high concentration of nitrous oxide except PAP and PVR. It would be suggested that hemodynamic changes might not be sensitive index during hypoxia induced by high concentration of nitrous oxide exposure.

  • PDF