• Title/Summary/Keyword: 저항 저감

Search Result 367, Processing Time 0.041 seconds

A Study on the Application Methods of Chemicals for Reducing Grounding Resistance of the Bar-Shaped Electrode on the Power Distribution System (배전계통에서 봉형접지극의 접지저항 향상을 위한 접지저항저감제 사용방법에 관한 연구)

  • Park, Jung-Shin;Na, Chae-Dong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.136-144
    • /
    • 2010
  • The bar-shaped electrode is very popular for earth construction in Korea. Copper ground rod, Deep-buried ground rod and conductive concrete ground rod are major types of the bar-shaped electrode and generally applied on the distribution system. But in most case, to obtain the targeted ground resistance is difficult, because ground resistance is very different by soil condition. Therefore, a chemicals for reducing ground resistance is applied. In this paper, the initial and the variation of ground resistance according to the applied methods and types of chemicals over one year are compared with copper ground rod applied with water and the experimental results show that the new methods with chemicals reduced not only the initial ground resistance but also the variation of ground resistance over year.

Study of Shape Optimization for Aerodynamic Drag Reduction of High-speed train (공기저항 저감을 위한 고속열차 형상 최적설계 연구)

  • Yun, Su-Hwan;Kwak, Min-Ho;Park, Choon-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.6
    • /
    • pp.709-716
    • /
    • 2016
  • To reduce the aerodynamic drag of high speed trains, aerodynamic drag of KTX-Sancheon was analyzed in detail according to individual components. Aerodynamic drag values of the power cars (front car, rear car) and bogies are about 42.9% and 10.1% of the total aerodynamic drag, respectively. For the aerodynamic drag reduction of a power-car, a nose shape optimization was conducted using the Broyden-Fletcher-Goldfarb-Shanno optimum method. Shape change of a power car and bogie fairing adaptation are used to reduce the aerodynamic drag of a car body. The aerodynamic drag of the optimized train-set dropped by 15.0% compared to the aerodynamic drag of the KTX-Sancheon; a running resistance reduction of 12% is expected at the speed of 350km/h.

Commutation torque ripple reduction in brushless dc motor considering phase resistance (상 저항을 고려한 BLDC Motor의 상 전환 토크리플 저감에 대한 연구)

  • Oh, Dae-Young;Choy, Ick;Song, Joong-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.220-222
    • /
    • 2007
  • 본 논문에서는 하나의 DC-Link 전류센서를 사용하여 BLDC 모터의 상 저항을 고려한 상 전환 토크리플 저감 방법을 제안하고자 한다. 지금까지 하나의 DC-Link 전류센서를 사용하여 BLDC 모터의 상 전환 토크리플 저감에 대한 연구는 많이 진행 되어 왔다. 기존의 방법들은 상 저항 값을 무시하여 상 인덕턴스 성분만을 가지고 제어한 방법이 주류를 이루어 왔다. 하지만 상 저항 값이 크면, 저속 영역과 고속 영역 구간에 변화를 가져와 기존의 방법을 사용할 시 토크리플이 발생한다. 또한 상 전환 시 전류 기울기와 상 전환 시간에 대해 영향을 미치게 되어 기존의 방법을 사용할 경우 토크리플이 발생하게 된다. 본 논문에서는 시뮬레이션을 통하여 상 저항을 고려한 BLDC 모터의 상 전환 토크리플 저감 방법에 대해 효용성을 입증하고자 한다.

  • PDF

Aerodynamic Drag Reduction on High-performance EMU Train by Streamlined Shape Modification (유선형 형상 개선을 통한 고성능 EMU 열차의 공기저항 저감 연구)

  • Kwon, Hyeok-Bin;Hong, Jai-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.3
    • /
    • pp.169-174
    • /
    • 2013
  • The effect of modifying the shape of a high-performance EMU train on the aerodynamic drag is studied here using Computational Fluid Dynamics(CFD) based on three dimensional Steady-state Navier-Stokes equation and two equation turbulence modeling. FLUENT 12 and Gambit 2.4.6 are employed for a numerical simulation of the aerodynamic drag of a streamlined-shape train as well as a proto type train. The characteristics of the aerodynamic drag of trains in tunnels are analyzed in a comparison with these characteristics in an open space. The contribution of the aerodynamic drag of each case is also investigated to establish principal pertaining to drag reduction for urban trains in tunnels. The aerodynamic drag of a streamlined train was reduced to 9.8% relative to a proto-type train with a blunt nose and a protruding roof facility and underbody shape: the running resistance is expected to be reduced by as much as 4% at a running speed of 80km/h.

Wind Tunnel Test of 2D Model for Plasma Flow Control using DBD Plasma Actuator (DBD 플라즈마 구동기를 이용한 2차원 모델의 플라즈마 유동제어 풍동시험)

  • Yun, Su-Hwan;Kim, Tae-Gyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.527-528
    • /
    • 2012
  • DBD (Dielectric Barrier Discharge) plasma actuator was designed for aerodynamic drag reduction using plasma flow control, and the drag reduction was measured by wind-tunnel tests using 2D test model. At the zero wind velocity, the plasma flow control had no effect on the drag reduction because the flow separation and surface friction drag were not occurred. At the wind velocity of 2m/s, 9.7% of drag was reduced by the flow separation control. The drag reduction decreased as the wind velocity increased.

  • PDF

Characteristic of organic/inorganic composite formed grounding resistance lowering agents (유/무기 복합재료형 접지저감제의 특성)

  • Kim, Jang-Wook;Chung, Chul-Hee;Cho, Dae-Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.74-80
    • /
    • 2004
  • Among inorganic materials, it is grounding resistance lower agent of new form that use being strata style clay and makes using water soluble polymer by main material to organic substance. Water soluble polymer chains are dispertion in water because water soluble polymer reacts with water if is done and these discrete polymer chains are inserted to floor of being strata style clay with water. This material that moisture content is very excellent and rate of expansion, electrical conductivity that measure after supplies water of 300wt % as well as is excellent. Can prevent corrosion or electrolytic corrosion of grounding bar securing very environmentally, chemically and pollution of soil. When applied to general grounding rod worker $7{\sim}8$ times ground resistance reduction effect of not application.

  • PDF

Investigation of Skin Friction Reduction Mechanism of Outer-Layer Vertical Blades Using POD Analysis (POD 기법을 이용한 경계층 외부 수직날의 마찰저항 저감 기구에 관한 관측)

  • An, Nam Hyun;Park, Seong Hyeon;Chun, Ho Hwan;Lee, Inwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.567-575
    • /
    • 2013
  • A POD analysis based on time-resolved PIV measurements in a circulating water channel has been conducted to identify the skin friction reduction mechanism of outer-layer vertical blades. A recent PIV measurement indicated 2.73% and 7.95% drag reduction in the blade plane and the blade-in-between plane, respectively. In the present study, the influence of vertical blades array upon the characteristics of the turbulent coherent structures was analyzed by the POD method. It is observed that the vortical structures are cut and deformed by the blades array and that their temporal evolution is strongly associated with the skin-friction drag reduction mechanism in the turbulent boundary layer flow.

The Ground Resistance Reduction Effect of o Conductive Expansion Ground Resistance Reducing Material (도전성 팽창 접지저감재의 접지저항 저감 효과)

  • Kim, Jong-Wook;Kim, Kyung-Chul;Choi, Jong-Kee;Kang, Min-Gyu;Baek, Nam-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.155-161
    • /
    • 2008
  • The grounding systems provide a low resistance path for fault or normal currents into the earth. The material for reducing ground resistance is buried around the grounding electrode to increase its effective size of the electrode and thus to obtain low ground resistance. Increasing the contacting area with the grounding electrode is effective for lowering the ground resistance in soils. Using this idea the conductive expansion ground resistance reducing material was developed. In this paper experimental data has shown that the ground resistance reduction method using proposed material is superior to using a typically available commercial ground resistance reducing material.

Resistivity Analysis of Model Block for Using of Structure Grounding Electrode (구조체접지극 활용을 위한 모형블록의 저항률 분석)

  • Kim, Sung-Sam;Jeong, Man-Gil;Choi, Jong-Kyu;Koh, Hee-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.40-45
    • /
    • 2007
  • This study analyzed the resistivity characteristic of model block to make the good use of structure grounding and substitution grounding electrode base of building. After making the model block of mortar and concrete block, it measured resistivity in hydrous condition and dry condition and compared with the blocks that is mixed earth resistance lowering agent to decrease resistivity. The resistance value of block accepted much influence by block resistivity. When the block resistivity was same or similar value, the value of soil resistivity has occurred as different as the value of grounding resistance.

Material Properties and Shrinkage Crack Resistance of Concrete Produced with Fluorine-Silicate Hybrid Type Crack Reducing Agent (불소-실리카 복합형 균열저감제가 첨가된 콘크리트의 재료 특성과 수축균열 저항성)

  • Lee, Man-Ik;Park, Jong-Hwa;Nam, Jae-Hyun;Kim, Do-Su;Kim, Jae-On
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.553-558
    • /
    • 2006
  • In this study, fluorine-silicate hybrid type crack reducing agent(FS) consisted of fluorine and silicate compounds applied to concrete mix(specification : 25-30-18) between 0.5% and 2.0% at intervals of 0.5% based on cement weight. Experiments for material properties of concrete such as slump, air content and bleeding with elapsed time were performed. Experiment and elucidation for shrinkage crack resistance as well as adiabatic hydration temperature were also carried out. It was appeared that FS addition contributed to lower bleeding and hydration temperature without disturbance of fresh properties of concrete such as slump and air content compared to non-added concrete. Especially, shrinkage crack resistance of concrete resulted from plastic and drying shrinkage could be effectively reduced by the addition of FS ranging from 1.0% to 1.5%.