• Title/Summary/Keyword: 저항 모델

Search Result 1,091, Processing Time 0.027 seconds

Transpiration Modelling and Verification in Greenhouse Tomato (온실재배 토마토의 증산모델 개발 및 검증)

  • 이변우
    • Journal of Bio-Environment Control
    • /
    • v.6 no.3
    • /
    • pp.205-215
    • /
    • 1997
  • An accurate transpiration model for greenhouse tomato crop, which is liable to transpiration depression and yield loss because of low solar radiation and high humidity, could be an efficient tool for the optimum control of greenhouse climate and for the optimization of Irrigation scheduling. The purpose of this study was to develop transpiration model of greenhouse tomato and to carry out the experimental verification. The formulas to calculate the canopy transpiration and temperature simultaneously were derived from the energy balance of canopy. Transpiration and microclimate variables such as net radiation, solar radiation, humidity, canopy and air temperature, etc. were simultaneously measured to estimate parameters of model equations and to verify the suggested model. Leaf boundary layer resistance was calculated as a function of Nusselt number and stomatal diffusive resistance was parameterized by solar radiation and leaf-air vapor pressure deficit. The equation for stomatal diffusive resistance could explain more than 80% of its variation and the calculated stomatal diffusive resistance showed good agreements with the measured values in situations independent of which the constants of the equation were estimated. The canopy net radiation calculated by Stanghellini's model with slight modification agreed well with the measured values. The present transpiration model, into which afore-mentioned component equations were assembled, was found to predict the canopy temperature, instantaneous and daily transpiration with considerable accuracy in greenhouse climates.

  • PDF

Intraorganizational diffusion and innovation resistance of high technology products (기술 제품의 조직내 확산과 혁신저항)

  • Dae-Ryun Chang;Seong-Do Cho
    • Asia Marketing Journal
    • /
    • v.1 no.2
    • /
    • pp.100-115
    • /
    • 1999
  • 본 연구는 기업이 기술제품을 도입한 후에 내부에 확산시키려고 하는 실행단계에서 직면하는 혁신저항에 영향을 미치는 요인과 혁신저항을 줄이고 확산을 증진시키는 확산촉진활동을 설명하여 2B 마케팅 상황에서 기술제품의 조직내 혁신저항-확산모델을 도출하였다. 기업에서 기술제품을 조직내에 확산시킬 때는 구성원들의 혁신저항을 접하게 된다. 소비자 행동에서는 혁신저항에 영향을 주는 변수로 개인변수와 제품변수를 제시하고 있지만 2B 마케팅에서는 조직구조변수와 구매센터변수가 추가적으로 영향을 주게 된다. 중앙집권화, 공식화정도가 높은 기업에서는 구성원들이 혁신저항을 가지면서도 사용할 수 있다. 이러한 경우에는 판매기업과 구매기업의 관계가 단기적인 관계로만 그칠 수 있다. 또한 구매센터 참여정도가 적고 구매센터가 집중화되어 있으면 혁신저항이 커지고 단기적인 관계만 형성될 가능성이 커진다. 그리고 제품의 지각된 위험, 적합성에 따라 혁신저항의 정도가 달라질 것이다. 그리고 사용자 개인의 지각된 자기능력, 현 제품의 만족도 등이 의미있는 조절 변수 역할을 할 것이다. 그러므로 장기적인 관계로 이어지기 위해서는 혁신저항을 줄이는 교육훈련, 제품개선, 부서간 조정, 개인적 동기 부여와 같은 확산촉진활동이 있어야 한다. 따라서 본 연구를 통해 판매기업과 경영자들은 기술제품에 대한 혁신저항을 극복하고 제품을 확산시킬 수 있는 학문적, 관리적 시사점을 얻을 수 있을 것이다.

  • PDF

Cold FET modeling and examination of validness of parasitic resistances (수동 FET 모델링과 기생저항값의 유효성 검증)

  • Kim, Byung-Sung
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.2
    • /
    • pp.1-10
    • /
    • 1999
  • Direct extraction of FET's small signal model parameters needs predetermined parasitic elements usually obtained under forward cold FET conditionl This paper derives analytic intrinsic model for cold FET's and shows that normal cold FET condition can replace forward cold FET condition for extracting parasitic elements. Then, we track the error of hot FET's small signal model bounded by the cold FET condition and examine the validness of cold parasitic resistances by checking the existence of the error minimum.

  • PDF

Time-lapse Inversion of 2D Resistivity Monitoring Data (2차원 전기비저항 모니터링 자료의 시간경과 역산)

  • Kim, Ki-Ju;Cho, In-Ky;Jeoung, Jae-Hyeung
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.4
    • /
    • pp.326-334
    • /
    • 2008
  • The resistivity method has been used to image the electrical properties of the subsurface. Especially, this method has become suitable for monitoring since data could be rapidly and automatically acquired. In this study, we developed a time-lapse inversion algorithm for the interpretation of resistivity monitoring data. The developed inversion algorithm imposes a big penalty on the model parameter with small change, while a minimal penalty on the model parameter with large change compared to the reference model. Through the numerical experiments, we can ensure that the time-lapse inversion result shows more accurate and focused image where model parameters have changed. Also, applying the timelapse inversion method to the leakage detection of an embankment dam, we can confirm that there are three major leakage zones, but they have not changed over time.

Study of Gas-turbine Cranking Model using the Coast Down Experimental Results (Coast Down 시험데이터를 이용한 가스터빈엔진 시동모델 연구)

  • Kim, Sun Je;Kim, Yeong Ryeon;Min, Seongki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.3
    • /
    • pp.18-24
    • /
    • 2017
  • Appropriate selection of the starter is essential for successful starting of the gas-turbine engine. Thus, aerodynamic drag during starting phase should be analyzed to assess the feasibility of the starter. In this paper, aerodynamic drag is modeled based on the speed profile from the engine coast down test, and it is scaled with respect to the target engine by comparing the compressor load. Afterward, the govern equation of the starting phase is developed with the torque model of the starter, and the design scheme to select the feasible starter will be finally suggested. The proposed model of starting phase will be useful to perform a preliminary design of the starting system of the gas-turbine engine.

Spectral Inversion of Time-domain Induced Polarization Data (시간영역 유도분극 자료의 Cole-Cole 역산)

  • Kim, Yeon-Jung;Cho, In-Ky
    • Geophysics and Geophysical Exploration
    • /
    • v.24 no.4
    • /
    • pp.171-179
    • /
    • 2021
  • We outline a process for estimating Cole-Cole parameters from time-domain induced polarization (IP) data. The IP transients are all inverted to 2D Cole-Cole earth models that include resistivity, chargeability, relaxation time, and the frequency exponent. Our inversion algorithm consists of two stages. We first convert the measured voltage decay curves into time series of current-on time apparent resistivity to circumvent the negative chargeability problem. As a first step, a 4D inversion recovers the resistivity model at each time channel that increases monotonically with time. The desired intrinsic Cole-Cole parameters are then recovered by inverting the resistivity time series of each inversion block. In the second step, the Cole-Cole parameters can be estimated readily by setting the initial model close to the true value through a grid search method. Finally, through inversion procedures applied to synthetic data sets, we demonstrate that our algorithm can image the Cole-Cole earth models effectively.

A Substrate Resistance and Guard-ring Modeling for Noise Analysis of Twin-well Non-epitaxial CMOS Substrate (Twin-well Non-epitaxial CMOS Substrate에서의 노이즈 분석을 위한 Substrate Resistance 및 Guard-ring 모델링)

  • Kim, Bong-Jin;Jung, Hae-Kang;Lee, Kyoung-Ho;Park, Hong-June
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.4
    • /
    • pp.32-42
    • /
    • 2007
  • The substrate resistance is modeled to estimate the performance degradation of analog circuits by substrate noise in a $0.35{\mu}m$ twin-well non-epitaxial CMOS process. The substrate resistance model equations are applied to the P+ guard-ring isolation structure and a good match was achieved between measurements and models. The substrate resistance is divided into four types and a semi-empirical model equation is obtained for each type of substrate resistance. The rms(root-mean-square) error of the substrate resistance model is below 10% compared with the measured resistance. To apply this substrate resistance model to the P+ guard ring structure, ADS(Advanced Design System) circuit simulation results are compared with the measurement results using Network Analyzer, and relatively good agreements are obtained between measurements and simulations.

Numerical Model to Evaluate Resistance against Direct Shear Failure and Bending Failure of Reinforced Concrete Members Subjected to Blast Loading (폭발하중을 받는 철근콘크리트 부재의 직접전단 파괴 및 휨 파괴 저항성능 평가를 위한 수치해석 모델 개발)

  • Ju, Seok Jun;Kwak, Hyo-Gyoung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.6
    • /
    • pp.393-401
    • /
    • 2021
  • In this paper, we proposed a numerical model based on moment-curvature, to evaluate the resistance of reinforced concrete (RC) members subjected to blast loading. To consider the direct shear failure mode, we introduced a dimensionless spring element based on the empirical direct shear stress-slip relation. Based on the dynamic increase factor equations for materials, new dynamic increase factor equations were constructed in terms of the curvature rate for the section which could be directly applied to the moment-curvature relation. Additionally, equivalent bending stiffness was introduced in the plastic hinge region to consider the effect of bond-slip. To verify the validity of the proposed model, a comparative study was conducted against the experimental results, and the superiority of this numerical model was confirmed through comparison with the analytical results of the single-degree of freedom model. Pressure-impulse (P-I) diagrams were produced to evaluate the resistance of members against bending failure and direct shear failure, and additional parametric studies were conducted.

Analyses of Spectral IP Responses over 20-Degree Dipping Structure (20도 경사구조에 대한 스펙트럴 IP응답의 해석)

  • Kim, Hee Joon
    • Economic and Environmental Geology
    • /
    • v.19 no.3
    • /
    • pp.219-224
    • /
    • 1986
  • Spectral induced polarization (IP) responses for 20-degree dipping body are obtained by both numerical and scale models. The IP responses for the dipping body vary not only with current frequencies but also with resistivity ratios between the body and the surrounding medium. If the ion concentration related to polarizable reaction is constant, the resistivity of polarizable body depends only on the current frequency. This implies that the IP responses to the resistivity ratio are qualitatively equivalent to those to the current frequency. The numerical results with wide-range resistivity ratios, therefore, can be used as standard curves for the interpretation of spectral IP data.

  • PDF

Ground Impedance Characteristics for Grounding System on Power Substation (정상시 접지계통의 접지 임피던스 특성)

  • Kim, Jae-Yee;Ko, Young-Hyuk;Ko, Young-Gwon;Kim, Jeong-Bu;Jeong, Kil-Jo;Ki, Hyun-Chan;Choi, Jong-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2207-2209
    • /
    • 2000
  • 본 논문에서는 접지 모델을 활용하여 접지계의 임펄스 임피던스를 계산하고, 선로 임피던스에 연결된 접지 임피던스의 반사계수를 계산하여 대지로 유입되는 분류율을 평가하였다. 따라서 접지 저항을 낮추는 경우 평상시 전위 상승효과를 줄일 수는 있지만 위험전압의 인가시에는 인축의 안전과 기기의 절연 측면에서 악조건의 상황이 될 수 있다. 또한 접지 모델에서 용량의 변화와 접지 저항의 변화에 따른 반사계수의 변화를 확인하였고, 상용 주파수 근처에서는 저항 성분만 존재하고 리액턴스 효과는 없음을 확인하였다.

  • PDF