• Title/Summary/Keyword: 저유속

Search Result 143, Processing Time 0.034 seconds

Doppler Signal Analysis for Low Velocity Measurement (저 유속 측정에서의 도플러 해석 기법)

  • Lee, Jonggil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.956-957
    • /
    • 2014
  • In a fluid velocity measurement radar, the velocity information can be extracted from Doppler spectrum estimates of the return signal. However, the Doppler frequency ranges are too low for the case of low velocity profile measurements resulting in the serious effects in the velocity measurement. Therefore, the improved method is analyzed to overcome this problem.

  • PDF

Development of High-performance Microwave Water Surface Current Meter for General Use to Extend the Applicable Velocity Range of Microwave Water Surface Current Meter on River Discharge Measurements (전자파표면유속계를 이용한 하천유량측정의 적용범위 확장을 위한 고성능 범용 전자파표면유속계의 개발)

  • Kim, Youngsung;Won, Nam-Il;Noh, Joonwoo;Park, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.613-623
    • /
    • 2015
  • To overcome the difficulties of discharge measurements during flood season, MWSCM(micowave water surface current meter) which measures river surface velocities without contacting water has been applied in field work since its development. The existing version of MWSCM is for floods so that its applicability is low due to the short periods of floods. Therefore the renovative redesign of MWSCM to increase the applicability was conducted so that it can be applied to the discharge measurements during normal flows as well as flood ones by extending the measurable range of velocity. A newly developed high-performance MWSCM for general use can measure the velocity range of 0.03-20.0 m/s from flood flows to normal flows, whereas MWSCM for floods can measure the velocity range of 0.5-10.0 m/s. The improvement of antenna isolation between transmitter and receiver to block the inflow of transmitted singals to receiver and the improvement of phase noise of oscillator are necessary for detecting low velocity with MWSCM technology. Separate type antenna of transmitting and receiving signals is developed for isolation enhancement and phase locked loop synthesizer as an oscillator is applied to high-performance MWSCM for general use. Microwave frequency of 24 GHz is applied to the new MWSCM rather than 10 GHz to make the new MWSCM small and light for convenient use of it at fields. Improvement requests on MWSCM for floods-stable velocity measurement, self test, low power consumtion, and waterproof and dampproof-from the users of it has been reflected on the development of the new version of MWSCM.

A Study on the Surface Image Velocity Measurement Using GPS Electronic Floater in Lab-Scale (Lab-Scale에서의 GPS전자부자를 이용한 표면영상유속계측 연구)

  • Lee, Chang Hyun;Lee, Jeong Min;Kim, Young Do
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.158-158
    • /
    • 2020
  • 국내외 기상이변으로 인한 하천허용유량의 초과가 많이 일어나고 있다. 이때 사람이 직접 도섭으로 하천의 정보 대한 정보를 취득하기 어렵기 때문에 간접적인 방법으로의 정보취득이 중요시 되어야 한다. 그에 따른 방법으로 주입식의 표면부자를 활용한 방법이나, PIV 기법을 활용한 표면영상유속계측법을 이용한 유속측정방법 등이 있다. 하지만 이런 표면영상유속계측법은 영상의 변위가 커지게 되어 시간간격 설정에 대한 어려움 등이 있고, 표면부자법의 경우 표면 유속을 대변 할 수 있을지에 대한 분석연구가 필요하다. 따라서 이러한 표면 영상 유속계측법과 표면부자의 수표면 유속 측정 능력 등을 분석하여 GPS 전자부자의 활용성을 확인해 보고자 하였다. Lab-Scale 수로에서 GPS전자부자를 입자로 활용하여 주입 후 흘러가는 부분을 영상촬영하고, LS-PIV 기법을 활용하여 분석한 후 검증이 된 전자유속계 (FlowTracker)의 데이터를 참값으로 비교 분석하였다. LS-PIV 기법을 통해서 GPS 전자부자의 표면 유속 측정 능력을 잘 검증해낸다면, 유속측정에 용이하고 접근성 및 안정성까지 확보할 수 있다. 더 나아가 홍수 시 사용뿐만 아니라, ADCP나 ADV로 측정이 불가능한 저수심·저유속의 중소하천에서도 적용할 수 있다. GPS전자부자의 지속적인 연구는 향후 하천 측정 시스템에 많은 도움을 줄 것으로 사료된다.

  • PDF

A study of a present condition of discharge measurement using ADCP in South Korea (ADCP를 이용한 유량측정 현황 분석)

  • Song, Jae Hyun;Kim, Chi Young;Kim, Sam Eun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.448-448
    • /
    • 2016
  • ADCP(Acoustic Doppler Current Profiler)는 유수의 흐름을 방해하지 않으면서 수중에 발사된 음파의 도플러 효과를 이용하여 유속과 유량을 측정하는 장비이다. ADCP는 하천을 횡단하면서 측정하는 장비이기 때문에 기존 유속-면적법에 비해 인력과 시간이 절감된다. 이러한 효율성 때문에 미국, 일본 등 외국뿐 아니라 우리나라에서도 점차 활용이 증가하고 있다. 특히 수위와 유량이 급격하게 변화하여 신속한 측정이 필요한 지점이나, 유속계를 이용한 유량측정이 곤란한 대하천에서 널리 사용되고 있다. ADCP는 미국을 중심으로 1980년대 말부터 하천 유량 측정에 도입된 후 여러 해 동안 현장에서의 적용성 평가가 이루어져 왔으며, 점차 적용이 확대되고 있는 실정이다. 국내에서도 1990년대 후반부터 ADCP가 도입되기 시작하여, 유량측정 기법 및 국내 하천에의 적용성에 대한 검토가 진행되어 왔으며, ADCP를 이용한 유량측정의 빈도와 활용범위가 점차 증가하고 있다. 국토교통부의 유량측정을 전담하고 있는 유량조사사업단의 2009년~2014년 측정장비별 측정성과를 살펴보면, 2009년 7.8%였던 ADCP 사용률은 2014년 27.8%로 약 3배 이상 증가하였으며, 2010년~2011년 4대강 공사로 인하여 사용률이 높아진 후, 2013년부터 본격적으로 사용된 것을 알 수 있다. ADCP뿐만 아니라 FlowTracker 역시 저유속 유량측정을 대체하고 있으며, 2009년 10.9%였던 FlowTraker와 ADCP 측정성과는 2014년 전체 측정성과의 56.2%를 차지하며, 기계식 유속계와 부자 측정성과를 넘어서고 있다. 홍수기(7월~8월) 측정성과를 살펴보면, 2009년 9.3%였던 ADCP 사용률은 2014년 31.8%로 전체 측정성과와 유사한 증가폭을 나타냈으며, 2012년 이후 사용률이 급증하고 있는 것을 알 수 있다. 본 연구에서는 국내 유량측정 사업에 사용률이 급격하게 증가하고 있는 ADCP의 활용 현황 및 문제점 등을 분석하여 향후 ADCP를 이용한 유속 및 유량측정의 체계적인 활용 및 측정기법의 개선에 활용하고자 한다.

  • PDF

Development of Surface Image Velocimetry with Space-Time Image Analysis (시공간 영상 분석을 이용한 영상 유속계의 개발)

  • Yu, Kwon-Kyu;Kim, Nam-Kil;Yoon, Byung-Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.483-487
    • /
    • 2010
  • 하천에서 물이 비교적 빠른 속도로 흘러가면 압력 변동, 하상의 조도, 하천내 구조물 등의 영향에 의해 수면이 끊임없이 변형을 일으키며 수면에 작은 물결(수면 파문)이 생긴다. 이러한 수면 파문은 유수에 의해 유수의 평균 유속으로 이류되며, 이 때문에 인간이 유수의 흐름을 시각적으로 인식할 수 있다. 이러한 표면 파문은 적절한 영상 분석을 하면 표면 유속 측정의 추적자로 이용할 수 있다. 본 연구는 유수 표면을 연속된 영상을 촬영하고, 일련의 영상을 시공간 영상(space-time image)으로 만든 뒤, 휘도 경사법(graylevel gradient method)으로 유속 벡터를 추출하는 새로운 방법을 제시하였다. 이 분석 과정은 기존의 입자 영상 유속계(PIV, Particle Image Velocimetry) 기법을 이용하는 방법보다 훨씬 간단하고 분석 시간도 크게 절약할 수 있다. 또한, 수면 파문의 전파에 따른 중력파의 영향을 시공간 영상의 처리 과정에서 잡음으로 간주하여 처리할 수 있다는 장점을 가지고 있다. 개발된 루틴을 표면 영상 유속계(SIV, Surface Image Velocimtery)에 구현하여 새로운 영상 유속계를 개발하였다. 시공간 영상 분속을 이용하는 새로운 영상 유속계를 실험실 수로의 영상 자료에 적용하여 그 정확도, 적용성, 장단점 등을 분석하였다. 제안된 방법에 의한 평균류 산정 결과는 물리적으로 타당하며, 저속 또는 저휘도에서의 분석 성능이 뛰어난 것으로 밝혀졌다. 다만, 이방향 흐름의 분석에서는 문제가 있는 것이 밝혀졌다.

  • PDF

Structural Safety Evaluation by Analysis of Pressure Variation Characteristics of Small Hydro Power Hydraulic Turbine Blades in Sewage Treatment Plant (하수처리장 소수력 수차 블레이드의 압력변화 특성 분석을 통한 구조안전성 평가)

  • Park, Yoo-Sin;Kim, Ki-Jung;Youn, Byong-Don
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.126-131
    • /
    • 2017
  • Numerical analysis using commercial CFD code was carried out to develop the drag force type vertical axis hydraulic turbine for the improvement of the production efficiency of small hydro energy at low flow velocity condition. Blade pressure changes and internal flows were analyzed according to the presence or absence of the hydraulic turbine blade holes at flow velocity of less than 1.0~3.0 m/s. According to the numerical results, the pressure and flow velocity is severly affected by the flow velocity in turbine blade with no holes, while the influence of flow velocity is comparatively decreased in turbine blade with holes. It is also found that the pressure and flow velocity on the blade surface with holes are evenly distributed with no singular location and it is believed that forming a hole in the blade may be helpful in terms of structural safety.

Application of microwave water surface current meter for measuring agricultural water intake (농업용수 사용량 계측을 위한 전자파 표면유속계의 적용)

  • Baek, Jongseok;Kim, Chiyoung;Lee, Kisung;Kang, Hyunwoong;Song, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.12
    • /
    • pp.1071-1079
    • /
    • 2020
  • For integrated water management, it is essential to secure basic data such as the amount of agricultural water intake. The river water intake through the intake weir is carried out through the agricultural irrigation canal, and a method for measuring the quantity of water intake is required to suit the characteristics of the measuring points. In this study, the accuracy of the calculated flow data was determined by applying a microwave water surface current meter. The microwave water surface current meter is a method of calculating surface velocity using doppler effect, which is mainly used in high-velocities situations such as flood. Surface velocity is difficult to represent the average velocity of the entire section at low dicharges or high wind speeds, it is considered to be low in continuous utilization throughout the year, and it is necessary to verify whether the measurement using an microwave water surface curren meter is appropriate in agricultural irrigation canal. The data measured with an microwave water surface curren meter were compared with the actual flow data to calculate the intake data in agricultural irrigation canal. In agricultural irrigation canal, the low-level discharge calculated using an microwave water surface current meter at a minimum velocity of about 0.3 m/s and a minimum discharge of about 1.0 m3/s or higher was found to have a high tendency and accuracy compared to the standard discharge, especially when the high discharge was high. Although effective results can be obtained in terms of quantity at low discharge, it is deemed that subsequent studies are needed to calculate the average discharge of the cross section at low discharge, given that the trend of data is unstable. Through this study, it is suggested that it is appropriate to calculate the amount of water intake through the microwave water surface current meter in artificial waterways with a certain discharge or higher, so it is expected to be widely distributed as a method for measuring river water intake.

Prediction of Mean Water Level Rise Behind Low-Crested Structures and Outflow Velocity from Openings by Using a Hybrid Method Based on Two Dimensional Model Test and Hydrodynamic Numerical Modeling (단면수리모형 및 해수유동모델링 결합기법에 의한 저마루 구조물 배후의 평균수위 상승 및 개구부 유출유속 예측)

  • Lee, Dal Soo;Lee, Ki-Jae;Yoon, Jae Seon;Oh, Sang-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.6
    • /
    • pp.410-418
    • /
    • 2017
  • The stability of low-crested structure (LCS) and overtopping discharge over a seawall behind the LCS are influenced by the water level behind the structure. Hence, the experimental results can be distorted unless the increase of water level is known when two-dimensional experiment is carried out. In order to estimate increase of the mean water level behind the low-crested structure, this study applied a hybrid technique that combined results of two-dimensional model test and hydrodynamic numerical modeling based on the relationship between the water level and discharge. By using this technique, the mean water level increase and flow field can be obtained almost at the same time, which resolved the above problem considerably. In addition, this method can provide an approximate information about the outflow velocity from the openings of the structure, which is helpful for selecting appropriate planar configuration of the low-crested structure.

합성섬유를 증발매체로한 저농도 방사성액체폐기물 처리

  • 김태국;김길정;이영희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.513-518
    • /
    • 1996
  • 저농도 방사성 액체폐기물의 최종 처리를 목적으로 본 연구에서는 면 35%와 Polyester 65%가 함유된 합성섬유를 증발매체로 하여 자연상태의 공기를 강제 송풍시키는 자연증발처리시설에서 증발에 영향을 미치는 주요 변수에 따라 증발 단위 면적당 Cs-137, Co-60을 함유한 방사성 폐액의 증발량측정 및 제염계수를 조사하였다. 증발효과는 유입공기의 습도가 낮고, 공기의 유속과 공급액의 유량이 증가하고 유입공기 및 폐액의 온도가 높아질수록 증발량이 증가하였다. 실험결과 유입된 공기는 1$0^{\circ}C$ 이상, 습도는 80% 이하, 공급폐액의 유량이 3.4 $\ell$/hr $m^2$ 이상, 공기유속은 1.14~l.47 m/sec 범위가 조업조건이며 이때 제염계수는 5.1 $\times$ $10^3$, 배출공기의 방사능 농도는 4.7$\times$$10^{-13}$ $\mu$Ci/$m\ell$ air로 측정되었다. 공급유량이 4.6$\ell$/hr.$m^2$와 공기유속이 1.47 m,/sec일때 최대 증발조건으로 나타났으며, 이때 증발량은 총 증발면적 11,250$m^2$ 에서 1.2 ㎥/hr로 측정되었으며 대기의 온.습도 및 풍속에 따른 실험을 통하여 달톤형 증발식의 Wind Factor [Eh = (0.0168 + 0.0141V)$\Delta$H]를 도출하였다.

  • PDF